Your browser doesn't support javascript.
loading
Utilizing symmetrical tetramethyl cucurbit[6]uril-based supramolecular fluorescence probe for detection of paraquat in water.
Wang, Cheng-Hui; Zhang, Xiao-Wen; Chen, Dan-Tong; Li, Yuan-Xia; Huang, Ying; Xiao, Xin.
Afiliação
  • Wang CH; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China.
  • Zhang XW; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China.
  • Chen DT; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China.
  • Li YX; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China.
  • Huang Y; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China.
  • Xiao X; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Institute of Applied Chemistry, Guizhou University, Guiyang 550025, China. Electronic address: gyhxxiaoxin@163.com.
Spectrochim Acta A Mol Biomol Spectrosc ; 310: 123845, 2024 Apr 05.
Article em En | MEDLINE | ID: mdl-38219611
ABSTRACT
A supramolecular fluorescence probe has been developed using a symmetrical tetramethyl cucurbit[6]uril (TMeQ[6]) and a styryl derivative (SPy) with a host-guest ratio of 21. The introduction of paraquat (PQ) competes with SPy for the TMeQ[6] cavity, resulting in fluorescent quenching. The addition of 17 common herbicides and ions had negligible effects on the fluorescence quenching, indicating that the 2TMeQ[6]/SPy complex exhibits excellent selectivity in detecting PQ. The detection limit was found to be 4.62 × 10-7 M. More importantly, the probe was engineered to detect paraquat in river water by examining post-treatment samples and noting alterations in fluorescence color. The red to blue (R/B) intensity ratio is subsequently calculated to ascertain the PQ concentration. Experimental trials conducted on river water samples yielded recovery rates between 98.21 % and 108 %, with a relative standard deviation of less than 5 %. By pairing this with a smartphone-based colorimetric analysis application, we can facilitate portable PQ detection, enabling efficient and convenient monitoring across various locations.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2024 Tipo de documento: Article