Endogenous monoclonal immunoglobulins analyzed using the EXENT® solution and LC-MS.
Barnidge, David; Troske, Derek; North, Simon; Wallis, Gregg; Perkins, Mark; Harding, Stephen.
Afiliação
  • Barnidge D; The Binding Site, Part of ThermoFisher Scientific Research and Development Laboratory, 3777 40th Ave NW, Rochester, MN 55906, United States.
  • Troske D; The Binding Site, Part of ThermoFisher Scientific Research and Development Laboratory, 3777 40th Ave NW, Rochester, MN 55906, United States.
  • North S; The Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
  • Wallis G; The Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
  • Perkins M; The Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
  • Harding S; The Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
J Mass Spectrom Adv Clin Lab ; 32: 31-40, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38405412
ABSTRACT

Introduction:

The EXENT® Solution, a fully automated system, is a recent advancement for identifying and quantifying monoclonal immunoglobulins in serum. It combines immunoprecipitation with MALDI-TOF mass spectrometry. Compared to gel-based methods, like SPEP and IFE, it has demonstrated the ability to detect monoclonal immunoglobulins in serum at lower levels. In this study, samples that tested negative using EXENT® were reflexed to LC-MS to determine if the more sensitive LC-MS method could identify monoclonal immunoglobulins missed by EXENT®.

Objectives:

To assess whether monoclonal immunoglobulins that are not detected by EXENT® can be detected by LC-MS using a low flow LC system coupled to a Q-TOF mass spectrometer.

Methods:

Samples obtained from patients confirmed to have multiple myeloma (MM) were diluted with pooled polyclonal human serum and analyzed using EXENT®. If a specific monoclonal immunoglobulin was not detected by EXENT®, the sample was then subjected to analysis by LC-MS. For the LC-MS analysis, the sample eluate, obtained after the MALDI-TOF MS spotting step, was collected and transferred to an autosampler tray for subsequent analysis using LC-MS.

Conclusion:

LC-MS has the capability to detect monoclonal immunoglobulins that are no longer detected by EXENT®. Reflexing samples to LC-MS for analysis does not involve additional sample handling, allowing for a faster time-to-result compared to current approaches, such as Next-Generation Sequencing, Next-Generation Flow, and clonotypic peptide methods. Notably, LC-MS offers equivalent sensitivity in detecting these specific monoclonal immunoglobulins.