Your browser doesn't support javascript.
loading
Motion intention recognition of the affected hand based on the sEMG and improved DenseNet network.
Niu, Qunfeng; Shi, Lei; Niu, Yang; Jia, Kunming; Fan, Guangxiao; Gui, Ranran; Wang, Li.
Afiliação
  • Niu Q; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
  • Shi L; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
  • Niu Y; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
  • Jia K; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
  • Fan G; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
  • Gui R; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
  • Wang L; College of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Heliyon ; 10(5): e26763, 2024 Mar 15.
Article em En | MEDLINE | ID: mdl-38444500
ABSTRACT
The key to sEMG (surface electromyography)-based control of robotic hands is the utilization of sEMG signals from the affected hand of amputees to infer their motion intentions. With the advancements in deep learning, researchers have successfully developed viable solutions for CNN (Convolutional Neural Network)-based gesture recognition. However, most studies have primarily concentrated on utilizing sEMG data from the hands of healthy subjects, often relying on high-dimensional feature vectors obtained from a substantial number of electrodes. This approach has yielded high-performing sEMG recognition systems but has failed to consider the considerable inconvenience that the abundance of electrodes poses to the daily lives and work of patients. In this paper, we focused on transradial amputees and used sEMG data from the Ninapro DB3 database as our dataset. Firstly, we introduce a STFT (Short-Time Fourier Transform)-based time-frequency feature fusion map for sEMG. This map includes both time-frequency features and the time-frequency localization of sEMG signals. Secondly, we propose an Improved DenseNet (Dense Convolutional Network) model for recognizing motion intentions in the affected hand of amputees based on their sEMG signals. Finally, addressing the issue of optimizing the number of electrodes carried by amputees, we introduce the PCMIRR (Pearson Correlation and Motion Intention Recognition Rate) algorithm. This algorithm optimizes the number of channels by considering the Pearson correlation between the sEMG channels of amputees and the recognition rate of motion intentions in the affected hand based on single-channel sEMG data. The experimental results reveal that the recognition accuracy, recall, and F1 score achieved by the Improved DenseNet model were 93.82%, 93.61%, and 93.65%, respectively. When the number of electrodes was optimized to 8, the recognition accuracy reached 94.50%. In summary, this paper ultimately attained precise recognition of motion intentions in amputees' affected hands while utilizing the minimum number of sEMG channels. This method offers a novel approach to sEMG-based control of bionic robotic hands.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article