Deep Learning-Assisted Quantitative Measurement of Thoracolumbar Fracture Features on Lateral Radiographs.
Yuh, Woon Tak; Khil, Eun Kyung; Yoon, Yu Sung; Kim, Burnyoung; Yoon, Hongjun; Lim, Jihe; Lee, Kyoung Yeon; Yoo, Yeong Seo; An, Kyeong Deuk.
Afiliação
  • Yuh WT; Department of Neurosurgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.
  • Khil EK; Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.
  • Yoon YS; Department of Radiology, Fastbone Orthopedic Hospital, Hwaseong, Korea.
  • Kim B; Department of Radiology, Kyungpook National University Hospital, School of Medicine, Kyungpook National University, Daegu, Korea.
  • Yoon H; DEEPNOID Inc., Seoul, Korea.
  • Lim J; DEEPNOID Inc., Seoul, Korea.
  • Lee KY; Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.
  • Yoo YS; Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.
  • An KD; Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.
Neurospine ; 21(1): 30-43, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38569629
ABSTRACT

OBJECTIVE:

This study aimed to develop and validate a deep learning (DL) algorithm for the quantitative measurement of thoracolumbar (TL) fracture features, and to evaluate its efficacy across varying levels of clinical expertise.

METHODS:

Using the pretrained Mask Region-Based Convolutional Neural Networks model, originally developed for vertebral body segmentation and fracture detection, we fine-tuned the model and added a new module for measuring fracture metrics-compression rate (CR), Cobb angle (CA), Gardner angle (GA), and sagittal index (SI)-from lumbar spine lateral radiographs. These metrics were derived from six-point labeling by 3 radiologists, forming the ground truth (GT). Training utilized 1,000 nonfractured and 318 fractured radiographs, while validations employed 213 internal and 200 external fractured radiographs. The accuracy of the DL algorithm in quantifying fracture features was evaluated against GT using the intraclass correlation coefficient. Additionally, 4 readers with varying expertise levels, including trainees and an attending spine surgeon, performed measurements with and without DL assistance, and their results were compared to GT and the DL model.

RESULTS:

The DL algorithm demonstrated good to excellent agreement with GT for CR, CA, GA, and SI in both internal (0.860, 0.944, 0.932, and 0.779, respectively) and external (0.836, 0.940, 0.916, and 0.815, respectively) validations. DL-assisted measurements significantly improved most measurement values, particularly for trainees.

CONCLUSION:

The DL algorithm was validated as an accurate tool for quantifying TL fracture features using radiographs. DL-assisted measurement is expected to expedite the diagnostic process and enhance reliability, particularly benefiting less experienced clinicians.