Your browser doesn't support javascript.
loading
Determination of Refractive Error Using Direct Ophthalmoscopy in Children.
Vijendran, Sruthi; Kamath, Yogish S; Alok, Yash; Kuzhuppilly, Neetha I R.
Afiliação
  • Vijendran S; Department of Ophthalmology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Kamath YS; Department of Ophthalmology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Alok Y; Department of Community Medicine, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Kuzhuppilly NIR; Department of Ophthalmology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
Clin Ophthalmol ; 18: 989-996, 2024.
Article em En | MEDLINE | ID: mdl-38584720
ABSTRACT

Purpose:

Refractive error is a major cause of visual impairment in children and its early detection can prevent ocular morbidity such as amblyopia and strabismus. Brückner test is a comprehensive test which can be easily administered in children using a direct ophthalmoscope. We aimed to determine refractive error in children by analysis of the red reflex using modified Brückner test. Patients and

Methods:

This prospective observational study was conducted on 683 undilated eyes of 683 children aged four to 10 years. They were evaluated with a direct ophthalmoscope from one meter in a dimly lit room. The characteristics of the red reflex and crescent obtained were compared with photoscreener refraction value and analyzed.

Results:

The presence of superior crescent was associated with hypermetropia (Chi square 37.11, p < 0.001, kappa = 0.15) and inferior crescent with myopia (Chi square 157.29, p < 0.001, kappa = 0.477). Superior crescent was 98.4% sensitive in detecting hypermetropia. Hypermetropia greater than +1.5D, was associated with larger superior crescent crossing horizontal midline of pupil (Chi square = 5.29, p = 0.021).

Conclusion:

The modified Brückner test is useful in detection and quantification of refractive error in children. It is easy, simple, quick and can be employed in the community as a screening test to detect potentially amblyogenic refractive errors.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article