Your browser doesn't support javascript.
loading
Development of a two-dimensional LC-MS/MS system for the determination of proline and 4-hydroxyproline enantiomers in biological and food samples.
Ishii, Chiharu; Tojo, Yosuke; Iwasaki, Komei; Fujii, Akira; Akita, Takeyuki; Nagano, Masanobu; Mita, Masashi; Ide, Tomomi; Hamase, Kenji.
Afiliação
  • Ishii C; Graduate School of Pharmaceutical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Tojo Y; MIRAI Technology Institute, Shiseido Co., Ltd., 1-2-11 Takashima, Nishi-ku, Yokohama, 220-0011, Japan.
  • Iwasaki K; Graduate School of Pharmaceutical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Fujii A; Sakamoto Kurozu, Inc., 21-15 Uenosono-cho, Kagoshima, 890-0052, Japan.
  • Akita T; Graduate School of Pharmaceutical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Nagano M; Sakamoto Kurozu, Inc., 21-15 Uenosono-cho, Kagoshima, 890-0052, Japan.
  • Mita M; KAGAMI, Inc., 7-7-15, Saito-asagi, Ibaraki, Osaka, 567-0085, Japan.
  • Ide T; Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Hamase K; Graduate School of Pharmaceutical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. hamase@phar.kyushu-u.ac.jp.
Anal Sci ; 40(5): 881-889, 2024 May.
Article em En | MEDLINE | ID: mdl-38598049
ABSTRACT
A two-dimensional LC-MS/MS system has been developed for the enantioselective determination of proline (Pro), cis-4-hydroxyproline (cis-4-Hyp) and trans-4-hydroxyproline (trans-4-Hyp) in a variety of biological samples. The amino acids were pre-column derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), and the NBD-derivatives were separated by a reversed-phase column (Singularity RP18) as their D plus L mixtures in the first dimension. The collected target fractions were then introduced into the second dimension where the enantiomers were separated by a Pirkle-type enantioselective column (Singularity CSP-001S) and determined by a tandem mass spectrometer (Triple Quad™ 5500). The method was validated by the standard amino acids and also by human plasma, and sufficient results were obtained for the calibration, precision and accuracy. The method was applied to human plasma and urine, bivalve tissues and fermented food/beverages. D-Pro was widely found in the human physiological fluids, bivalves and several fermented products. Although trans-4-D-Hyp was not found in all the tested samples, cis-4-D-Hyp was present in human urine and tissues of the ark shell, and further studies focusing on the origin and physiological significance of these D-enantiomers are expected.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article