Local risk factors for one-year dental implant loss and late loss in 287 failed implants caused by peri-implantitis or infection after prosthesis loading: a retrospective study.
Zhai, Qin-Kai; Gao, Cao; Shen, Mo-Lun; Shui, Yu-Hao; Tang, Ting; Liu, Kun.
Afiliação
  • Zhai QK; Department of Oral and Maxillofacial Surgery, Hefei Stomatology Hospital, Hefei Stomatology Clinical College of Anhui Medical University, Hefei 230001, Anhui Province, China. Electronic address: zhaiqinkai@163.com.
  • Gao C; Department of Oral and Maxillofacial Surgery, Hefei Stomatology Hospital, Hefei Stomatology Clinical College of Anhui Medical University, Hefei 230001, Anhui Province, China.
  • Shen ML; Department of Oral and Maxillofacial Surgery, Hefei Stomatology Hospital, Hefei Stomatology Clinical College of Anhui Medical University, Hefei 230001, Anhui Province, China.
  • Shui YH; Department of Oral Implantology, Hefei Stomatology Hospital, Hefei Stomatology Clinical College of Anhui Medical University, Hefei 230001, Anhui Province, China.
  • Tang T; Department of Oral Implantology, Hefei Stomatology Hospital, Hefei Stomatology Clinical College of Anhui Medical University, Hefei 230001, Anhui Province, China.
  • Liu K; Department of Oral Implantology, Hefei Stomatology Hospital, Hefei Stomatology Clinical College of Anhui Medical University, Hefei 230001, Anhui Province, China.
Br J Oral Maxillofac Surg ; 62(6): 545-550, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38796330
ABSTRACT
The purpose of this paper was to retrospectively assess the local factors that are likely to be associated with the risks for one-year dental implant loss.A retrospective study was designed and implemented. The sample consisted of patients who underwent an implant loss or removal caused by peri-implantitis or infection after prosthesis loading. The chi-squared test and generalised estimating equations (GEE) were used to explore the potential risk factors for one-year implant loss. A total of 279 patients with 287 failed implants were enrolled in this study. Immediate implant placement exhibited a 3.373 (95% CI 1.652 to 6.886) significantly increased risk to experience one-year implant loss than early and late implant placement (p = 0.001). In addition, implants loaded during a healing period fewer than two months after implant placement were at 18.139 (95% CI 8.925 to 36.866) significantly higher risk of one-year implant loss when compared with those that loaded within more than two months after implant placement (p < 0.001). Smokers were 1.866 (OR = 1.866,95% CI 0.993 to 3.510) times as high risk for one-year implant loss as non-smokers, but there were no significant statistical differences (p = 0.053). Immediate implant placement and early implant loading were considered risk factors for one-year implant loss.