Your browser doesn't support javascript.
loading
Proton spot dose estimation based on positron activity distributions with neural network.
Zhang, Ruilin; Mu, Dengyun; Ma, Qiuhui; Wan, Lin; Xiao, Peng; Qi, Pengyuan; Liu, Gang; Zhang, Sheng; Yang, Kunyu; Yang, Zhiyong; Xie, Qingguo.
Afiliação
  • Zhang R; Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Mu D; Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Ma Q; School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China.
  • Wan L; School of Software Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Xiao P; Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Qi P; Wuhan National Laboratory of Optoelectronics, Wuhan, China.
  • Liu G; Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China.
  • Zhang S; Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Yang K; Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China.
  • Yang Z; Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Xie Q; Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Med Phys ; 2024 Jul 10.
Article em En | MEDLINE | ID: mdl-38984805
ABSTRACT

BACKGROUND:

Positron emission tomography (PET) has been investigated for its ability to reconstruct proton-induced positron activity distributions in proton therapy. This technique holds potential for range verification in clinical practice. Recently, deep learning-based dose estimation from positron activity distributions shows promise for in vivo proton dose monitoring and guided proton therapy.

PURPOSE:

This study evaluates the effectiveness of three classical neural network models, recurrent neural network (RNN), U-Net, and Transformer, for proton dose estimating. It also investigates the characteristics of these models, providing valuable insights for selecting the appropriate model in clinical practice.

METHODS:

Proton dose calculations for spot beams were simulated using Geant4. Computed tomography (CT) images from four head cases were utilized, with three for training neural networks and the remaining one for testing. The neural networks were trained with one-dimensional (1D) positron activity distributions as inputs and generated 1D dose distributions as outputs. The impact of the number of training samples on the networks was examined, and their dose prediction performance in both homogeneous brain and heterogeneous nasopharynx sites was evaluated. Additionally, the effect of positron activity distribution uncertainty on dose prediction performance was investigated. To quantitatively evaluate the models, mean relative error (MRE) and absolute range error (ARE) were used as evaluation metrics.

RESULTS:

The U-Net exhibited a notable advantage in range verification with a smaller number of training samples, achieving approximately 75% of AREs below 0.5 mm using only 500 training samples. The networks performed better in the homogeneous brain site compared to the heterogeneous nasopharyngeal site. In the homogeneous brain site, all networks exhibited small AREs, with approximately 90% of the AREs below 0.5 mm. The Transformer exhibited the best overall dose distribution prediction, with approximately 92% of MREs below 3%. In the heterogeneous nasopharyngeal site, all networks demonstrated acceptable AREs, with approximately 88% of AREs below 3 mm. The Transformer maintained the best overall dose distribution prediction, with approximately 85% of MREs below 5%. The performance of all three networks in dose prediction declined as the uncertainty of positron activity distribution increased, and the Transformer consistently outperformed the other networks in all cases.

CONCLUSIONS:

Both the U-Net and the Transformer have certain advantages in the proton dose estimation task. The U-Net proves well suited for range verification with a small training sample size, while the Transformer outperforms others at dose-guided proton therapy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article