Your browser doesn't support javascript.
loading
Exploring Perfluoroalkyl and Polyfluoroalkyl Substance Presence and Potential Leaching from Reverse Osmosis Membranes: Implications for Drinking Water Treatment.
Sadia, Mohammad; Ter Laak, Thomas L; Cornelissen, Emile R; van Wezel, Annemarie P.
Afiliação
  • Sadia M; Institute for Biodiversity and Ecosystem Dynamics, University of Amsterdam, P.O. Box 94240, Amsterdam, GE 1090, The Netherlands.
  • Ter Laak TL; Institute for Biodiversity and Ecosystem Dynamics, University of Amsterdam, P.O. Box 94240, Amsterdam, GE 1090, The Netherlands.
  • Cornelissen ER; KWR Water Research Institute, P.O. Box 1072, Nieuwegein, BB 3430, The Netherlands.
  • van Wezel AP; KWR Water Research Institute, P.O. Box 1072, Nieuwegein, BB 3430, The Netherlands.
Environ Sci Technol ; 58(35): 15799-15806, 2024 Sep 03.
Article em En | MEDLINE | ID: mdl-39171677
ABSTRACT
Reverse osmosis (RO) is increasingly used in drinking water production to effectively remove micropollutants, such as perfluoroalkyl and polyfluoroalkyl substances (PFAS). However, RO membranes themselves may contain PFAS, which can potentially leach into treated drinking water. Leaching experiments and direct total oxidizable precursor assays revealed the presence and leaching potential of PFOS (branched and linear), PFBA, PFHxA, PFNA, and PFOA in five selected commercial RO membranes. This resulted in the release of tens of milligrams of ΣPFAS per membrane element used in drinking water production. Depending on assumptions made regarding leaching kinetics and volume of produced water per membrane element, predicted concentrations of ΣPFAS in the produced water ranged from less than one up to hundreds of pg/L. These concentrations are two to four orders of magnitude lower than those currently observed in Dutch drinking waters. The origin of PFAS in the membranes remains unclear. Further research is needed to bridge the gap between the laboratory conditions as used in this study and the real-world conditions and for a full understanding of potential leaching scenarios. Such an understanding is critical for water producers using RO technologies to proactively manage and mitigate potential PFAS contamination.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article