Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Cancer Res Ther ; 14(6): 1389-1396, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30488861

RESUMEN

AIM: Dosimetric comparison of three different techniques in female lymphoma patients who had radiotherapy (RT) to the neck and mediastinum. SETTING AND DESIGN: Retrospective clinical study. MATERIALS AND METHODS: Computerized tomography-simulator images of eight patients were obtained retrospectively. Using 6 MV-X photon energy, RT plans were formed with three different techniques (anterior posterior-posterior anterior 2-field three-dimensional conformal RT [AP-PA 2-field 3D-CRT], 4-field 3D-CRT and "forward" plan intensity modulated RT [FPIMRT]). Comparisons were in terms of homogeneity index (HI), conformity index (CI), and inhomogeneity coefficient for planning target volume (PTV); mean lung dose, V5Gy, V10Gy, V20Gy, V30Gy for lung; Dmean, V7.5Gy, V15Gy, V25Gy for heart; Dmean, V3.5Gy, V10Gy, V20Gy for breast; Dmax for spine; Dmean, V10Gy, V18Gy, V25Gy, V30Gy for thyroid. STATISTICAL ANALYSIS USED: Since nonparametric tests had to be used due to the study population being < 30, Friedman and Wilcoxon signed-rank tests were implemented in trilateral and bilateral comparison of techniques, respectively. For statistical significance, P value was required to be <0.05. RESULTS: When FPIMRT was compared with AP-PA and 4-field techniques with respect to, HI (AP-PA/FPIMRT P: 0.017; 4-field/FPIMRT P: 0.03) and CI (AP-PA/FPIMRT P: 0.018; 4-field/FPIMRT P: 0.042), FPIMRT was more advantageous. In addition, FPIMRT was found more useful in terms of Dmax (AP-PA/FPIMRT P: 0.012; 4-Field/FPIMRT P: 0.012) for spinal cord and Dmean (AP-PA/FPIMRT P: 0.012; 4-field/FPIMRT P: 0.012) for thyroid. CONCLUSION: FPIMRT was superior in terms of PTV homogeneity and conformity. However, it was observed that for normal tissues, FPIMRT was advantageous only for spinal cord and thyroid; but it was not the most advantageous technique for some of the dose-volume parameters of the breast, lung, and heart.


Asunto(s)
Linfoma/radioterapia , Mediastino/efectos de la radiación , Cuello/efectos de la radiación , Radiometría/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos , Mama/efectos de la radiación , Femenino , Corazón/efectos de la radiación , Humanos , Pulmón/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Glándula Tiroides/efectos de la radiación
2.
Carbohydr Polym ; 181: 404-411, 2018 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-29253989

RESUMEN

In order to analyze the bending mechanism of the electroactive​ chitosan-based actuator, different amounts of poly(diallyldimethylammonium chloride) (PDAD) were incorporated in chitosan solution. The effects of PDAD concentration on electromechanical performance of chitosan actuator were investigated under various excitation voltages. With the incorporation of PDAD into chitosan solution, crosslinked chitosan film acts as an actuator showing a considerable displacement behavior. However it can be noted that higher incorporation of PDAD into chitosan solution decreased the performance of the actuators. Thermal, viscoelastic, and crystallographic properties of the chitosan films were examined by thermogravimetric analysis, dynamic mechanical analysis, and X-ray diffraction analysis, respectively. The effect of incorporation of PDAD in chitosan-based film on morphological properties of chitosan film was determined by scanning electron microscopy. It was observed that the films involving PDAD have larger pore size than the PDAD free film.