Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Phys Rev Lett ; 116(24): 241101, 2016 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-27367377

RESUMEN

We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8±0.7(stat)±6.7(syst) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principles calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.

2.
Phys Rev Lett ; 117(19): 192001, 2016 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-27858429

RESUMEN

Ultrahigh energy cosmic ray air showers probe particle physics at energies beyond the reach of accelerators. Here we introduce a new method to test hadronic interaction models without relying on the absolute energy calibration, and apply it to events with primary energy 6-16 EeV (E_{CM}=110-170 TeV), whose longitudinal development and lateral distribution were simultaneously measured by the Pierre Auger Observatory. The average hadronic shower is 1.33±0.16 (1.61±0.21) times larger than predicted using the leading LHC-tuned models EPOS-LHC (QGSJetII-04), with a corresponding excess of muons.

3.
Phys Rev Lett ; 109(6): 062002, 2012 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-23006259

RESUMEN

We report a measurement of the proton-air cross section for particle production at the center-of-mass energy per nucleon of 57 TeV. This is derived from the distribution of the depths of shower maxima observed with the Pierre Auger Observatory: systematic uncertainties are studied in detail. Analyzing the tail of the distribution of the shower maxima, a proton-air cross section of [505±22(stat)(-36)(+28)(syst)] mb is found.

4.
Eur J Paediatr Dent ; 22(2): 144-150, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34238006

RESUMEN

AIM: This study was purposed to evaluate release of nickel and chromium ions and methyl methacrylate (MMA) monomers from functional appliances and their possible health effects. MATERIALS AND METHODS: Study design: Twin-block appliances and Bionators were immersed in artificial saliva and kept in a thermal incubator. Control group was established as artificial saliva without appliances. Artificial saliva was analysed after 7 days, 30 days and 90 days. Inductively coupled plasma mass spectrometry and gas chromatography-mass spectrometry was used for detection of nickel and chromium ions and MMA monomers. MTT assays and cytokine array were performed. STATISTICS: One way ANOVA with Tukey test and Dunnett's T3 for post-hoc analysis was used for evaluation of time-dependent changes and independent t-test was used for evaluation of MTT assay results. RESULTS: The results revealed that metal ions and MMA monomers are released from the appliances. Metal ion detection pattern was irregular and could not be analysed. Twin-block group showed significantly larger amount of MMA release. MTT assay revealed statistically significant but minimally reduced cellular activity on Bionator and twin-block groups compared to control groups. Cytokine array showed no or less inflammatory cytokine release on Bionator and twin-block groups. CONCLUSION: MMA monomer release was confirmed but the cytotoxic effect of functional appliance material release is minimal or negligible. General toxicity of the functional appliance from the MMA monomer release is likely to be minimal or negligible.


Asunto(s)
Níquel , Ortopedia , Cromo/toxicidad , Humanos , Metacrilatos , Metilmetacrilato/toxicidad , Níquel/toxicidad , Aparatos Ortodóncicos
5.
Phys Rev Lett ; 104(9): 091101, 2010 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-20366976

RESUMEN

We describe the measurement of the depth of maximum, X{max}, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10;{18} eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106{-21}{+35}) g/cm{2}/decade below 10{18.24+/-0.05} eV, and (24+/-3) g/cm{2}/decade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm{2}. The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.

6.
Eur Phys J C Part Fields ; 75(6): 269, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26120280

RESUMEN

Energy-dependent patterns in the arrival directions of cosmic rays are searched for using data of the Pierre Auger Observatory. We investigate local regions around the highest-energy cosmic rays with [Formula: see text] eV by analyzing cosmic rays with energies above [Formula: see text] eV arriving within an angular separation of approximately 15[Formula: see text]. We characterize the energy distributions inside these regions by two independent methods, one searching for angular dependence of energy-energy correlations and one searching for collimation of energy along the local system of principal axes of the energy distribution. No significant patterns are found with this analysis. The comparison of these measurements with astrophysical scenarios can therefore be used to obtain constraints on related model parameters such as strength of cosmic-ray deflection and density of point sources.

7.
AJNR Am J Neuroradiol ; 32(4): E58-60, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20299440

RESUMEN

A 52-year-old man presented with subacute thyroiditis and showed an intensely hypermetabolic thyroid lesion on (18)F-FDG PET/CT. The patient also had coexisting chronic lymphocytic thyroiditis. The lesion of subacute thyroiditis revealed an SUV(max) of 9.1 g/mL and was ill-defined, heterogeneous, markedly hypoechoic, and hypovascular on US. Biopsy demonstrated histologic findings of subacute thyroiditis, which should be included in the differential diagnosis of an intensely hypermetabolic thyroid lesion on (18)F-FDG PET/CT.


Asunto(s)
Biopsia con Aguja Fina , Enfermedad de Hashimoto/diagnóstico , Tomografía de Emisión de Positrones , Tiroiditis Supurativa/diagnóstico , Tomografía Computarizada por Rayos X , Diagnóstico Diferencial , Fluorodesoxiglucosa F18 , Enfermedad de Hashimoto/complicaciones , Enfermedad de Hashimoto/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Neoplasias de la Tiroides/diagnóstico , Tiroiditis Supurativa/complicaciones , Tiroiditis Supurativa/metabolismo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda