Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Clin Lab ; 68(2)2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35142176

RESUMEN

BACKGROUND: In this study, our purpose was to evaluate the analytical performances of the STA R Max and CN-3000, and compare the results of both for PT, aPTT, fibrinogen, D-dimer, and factor VIII, and also to show the influence of hemolysis on PT, aPTT, and fibrinogen assays. METHODS: Three hundred ninety-five randomly-selected blood samples from residual material from Istanbul Faculty of Medicine, Central Laboratory workflow comprised the study group. PT, aPTT, fibrinogen, D-dimer, and factor VIII activity were done using both analyzers. Analytical performances were determined through precision, linearity, and comparability studies. Artificial hemolysis was performed through freezing-thawing and mechanical-sheer methods. RESULTS: Intra-assay and between-day CVs% of PT and aPTT were lower than 5% for STA R Max and CN-3000. Only the within-run and between-day CVs% of fibrinogen and the between-day CVs% of D-dimer were higher than 5%, but in acceptable targets. Intra-assay and between-day CVs% of FVIII on the CN-3000 were 3.5% and 12.3% at the low and 2.5% and 5.3% at high level, and 1.8% and 3.7% at the low and 6.3% and 5.9% at high level on the STA R Max. The comparison results of PT, aPTT, fibrinogen, and D-dimer were good (r > 0.91), also good correlations were obtained for FVIII activity > 40 IU/dL and FVIII between 5 - 40 IU/dL (r = 0.89). The results of the hemolysis study were within acceptable limits of the recommended criteria of Fraser and the manufacturer. CONCLUSIONS: CN-3000 and STA R Max coagulation analyzers are accurate and highly precise systems for safe use in clinical diagnostic applications. The interferences obtained for both analyzers were found to be within accepted targets.


Asunto(s)
Coagulación Sanguínea , Hemólisis , Pruebas de Coagulación Sanguínea , Humanos , Laboratorios , Tiempo de Tromboplastina Parcial
2.
J Pediatr Hematol Oncol ; 43(1): e99-e102, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-31764516

RESUMEN

Coagulation factor XIII (FXIII) is a fibrin-stabilizing factor with additional roles in wound healing and interactions between the decidua and fetus. Congenital FXIII deficiency is rare bleeding disorder. Inhibitor development against FXIII in inherited FXIII deficency is also uncommon, but may cause severe, life-threatening bleeding. FXIII is the last step in the coagulation cascade with normal coagulation paramaters (PT, aPTT), the detection of inhibitor to FXIII is quite difficult. The treatment of inhibitor-positive congenital FXIII deficiency is challenging due to the lack of a role of by-pass agents such as FVII. The best known ways of treatment in these cases are the use of high-dose FXIII concentrates and immunosuppression. Herein, we report the management of postoperative bleeding diathesis in a patient with FXIII deficiency who developed inhibitors, and to follow the clinical course of the disease with FXIII concentrate and immunosuppression.


Asunto(s)
Anticuerpos Neutralizantes/inmunología , Inhibidores de Factor de Coagulación Sanguínea/sangre , Deficiencia del Factor XIII/complicaciones , Factor XIII/antagonistas & inhibidores , Trastornos Hemorrágicos/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Isoanticuerpos/sangre , Inhibidores de Factor de Coagulación Sanguínea/inmunología , Niño , Factor XIII/inmunología , Trastornos Hemorrágicos/etiología , Trastornos Hemorrágicos/patología , Humanos , Masculino , Pronóstico
3.
Scand J Clin Lab Invest ; 81(4): 255-263, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34032527

RESUMEN

Coronaviruses belonging to the Coronaviridae family are single-stranded RNA viruses. The entry of SARS-CoV-2 is accomplished via ACE-2 receptors. SARS-CoV-2 infection coactivates both innate and adaptive immune responses. Although SARS-CoV-2 stimulates antibody production with a typical pattern of IgM/IgG, cellular immunity is also impaired. In severe cases, low CD4 + and CD8 + T cell counts are associated with impaired immune functions, and high neutrophil/lymphocyte ratios accompanying low lymphocyte subsets have been demonstrated. Recently, high IFN -α/γ ratios with impaired T cell responses, and increased IL-1, IL-6, TNF-α, MCP-1, IP-10, IL-4, IL-10 have been reported in COVID-19 infection. Increased proinflammatory cytokines and chemokines in patients with severe COVID-19 may cause the suppression of CD4 + and CD8 + T cells and regulatory T cells, causing excessive inflammatory responses and fatal cytokine storm with tissue and organ damage. Consequently, novel therapeutics to be developed against host immune system, including blockade of cytokines (IL-6, IL-1, IFN) themselves, their receptors or signaling pathways- JAK inhibitors- could be effective as potential therapeutics.


Asunto(s)
Antivirales/farmacología , Tratamiento Farmacológico de COVID-19 , COVID-19/inmunología , COVID-19/fisiopatología , Corticoesteroides/uso terapéutico , Animales , Antivirales/uso terapéutico , Síndrome de Liberación de Citoquinas/tratamiento farmacológico , Síndrome de Liberación de Citoquinas/etiología , Síndrome de Liberación de Citoquinas/virología , Citocinas/antagonistas & inhibidores , Citocinas/metabolismo , Glucocorticoides/uso terapéutico , Humanos , Hidroxicloroquina/uso terapéutico , Inmunoterapia/métodos , Macrófagos/inmunología , Macrófagos/patología , Macrófagos/virología
4.
Clin Lab ; 66(10)2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33073956

RESUMEN

BACKGROUND: Congenital factor VIII (FVIII) deficiency causes hemophilia A due to different types of defects in the FVIII gene. Although the chromogenic measurement is the reference method and shows less variability, a one-stage assay is the most commonly preferred method for measurement of FVIII. In this study, we aimed to evaluate the analytical performances of chromogenic and one-stage assays, and compare the results prior to introduction of newly developed extended half-life recombinant FVIII products. METHODS: Sixty-six blood samples from residual material of Istanbul Faculty of Medicine, Central Laboratory workflow comprised the study group. Samples were classified; plasma FVIII > 40 IU and FVIII < 40 IU. FVIII activities were measured using one-stage clotting and chromogenic assays on a CS-2500 analyzer. Analytical performances were determined through precision, linearity, carryover, and comparability studies. RESULTS: The within-run CV% of the one-stage assay on the CS-2500 had 1.6%, 2.6%, the between day CV% were 8.5%, 4.9 % for low and high controls, respectively. The within-run CV% of chromogenic method had 1.2% and 0.9%. Both methods demonstrated good linearity (R2 > 0.998), and the comparisons of both assays exhibited good agreement with minor bias for FVIII activity > 40 IU. However, a significant bias was obtained for FVIII activity < 40 IU. CONCLUSIONS: We obtained higher results using the one-stage assay compared with the chromogenic assay, and a significant bias was found for the samples lower than 40 IU. The discrepancy can explained by the presence of a weak agreement for samples lower than 10 IU due to the lower detection limit of the chromogenic assay used in this study (1.5%).


Asunto(s)
Factor VIII , Hemofilia A , Coagulación Sanguínea , Pruebas de Coagulación Sanguínea , Compuestos Cromogénicos , Hemofilia A/diagnóstico , Humanos
5.
Catheter Cardiovasc Interv ; 88(4): 618-624, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26909784

RESUMEN

BACKGROUND: This study sought to compare various outcomes among a new specifically designed transcatheter paravalvular leak closure (TPVLC) device and the devices that are being utilized off-label. METHODS: Between April 2012 and January 2015, in a prospective two-center study, 52 patients who needed surgical reintervention due to a hemodynamically significant prosthetic paravalvular leak were studied. This study population was divided into two groups. Group I was composed of 32 patients who underwent paravalvular leak (PVL) closure with the currently available devices that are being utilized off-label, while group II consisted of 20 patients who were treated with the new specifically designed Occlutech PVL device. RESULTS: Demographic and clinical variables indicated a higher rate of atrial fibrillation (P = 0.027) and chronic obstructive airway disease (P = 0.009) in group II. The apical approach was the most commonly used intervention route used for group II (P = 0.019). The procedural success rate was 100% (29 of 29 leaks) in group II while the rate was 92% (39 of 42 leaks) in group I. However, more secondary events were observed in group I, but they did not reach statistical significance (8 vs. 1, P = 0.064). CONCLUSIONS: With its high procedural success rate and encouraging outcome results, the Occlutech device seems to satisfy the expectations of a specifically designed PVL closure device. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Insuficiencia Cardíaca/terapia , Enfermedades de las Válvulas Cardíacas/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Válvulas Cardíacas , Hemólisis , Falla de Prótesis , Adulto , Anciano , Cateterismo Cardíaco/métodos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvulas Cardíacas/diagnóstico por imagen , Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Etiquetado de Productos , Estudios Prospectivos , Diseño de Prótesis , Retratamiento , Factores de Tiempo , Resultado del Tratamiento , Turquía
6.
Pacing Clin Electrophysiol ; 39(10): 1132-1140, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27418419

RESUMEN

BACKGROUND: The purpose of this study is to assess the electrocardiographic and electrophysiological parameters of conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI) due to severe aortic valve stenosis. METHODS: The study included 55 patients who underwent TAVI using either the Boston Scientific Lotus (n:25) (Boston Scientific, Natick, MA, USA) or Edwards Sapien XT (n:30) (Edwards Lifesciences, Irvine, CA, USA) prostheses. An electrophysiological study (EPS) was performed in the catheterization room immediately before the initial balloon valvuloplasty and immediately after prosthesis implantation. RESULTS: QRS duration and His-bundle to His-ventricle (HV) intervals, which were similar between the two groups before the procedure, were found to be significantly higher in the Lotus valve group postprocedure. Permanent pacemakers (PPMs) were required more frequently in the Lotus group than in the Sapien XT group at discharge (24.0% vs 6.7%, P = 0.07). With the exception of a higher prevalence of paravalvular leakage (P < 0.001) in patients undergoing Sapien XT implantation, other clinical outcomes were similar between the two groups. Multiple regression analysis revealed that baseline atrioventricular (AV) conduction disorders and HV intervals after the procedure were independently associated with PPM implantation after TAVI. CONCLUSION: In this first study comparing the findings of EPS and electrocardiography, the impact of the Lotus valve on AV conduction systems was greater than that of the Sapien XT. However, the need for PPM was higher in the Lotus valve than in the Sapien XT. PPM requirement is related to valve design; it may decrease with reduced frame height and metal burden in novel valve systems.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Sistema de Conducción Cardíaco/fisiopatología , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Bloqueo Atrioventricular/etiología , Electrocardiografía , Electrofisiología , Femenino , Humanos , Masculino , Marcapaso Artificial , Análisis de Regresión
7.
Ann Noninvasive Electrocardiol ; 20(2): 148-57, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25041063

RESUMEN

OBJECTIVES: Fragmented QRS (fQRS) has been found to be associated with high mortality and arrhythmic events in acute coronary syndromes. Regional systolic function using wall motion score index (WMSI) is an alternative to left ventricular ejection fraction (LVEF) for the assessment of left ventricular systolic function. The aim of this study was to investigate the relation between the presence of fQRS on admission electrocardiogram (ECG) and WMSI in ST elevation myocardial infarction (STEMI) underwent primary coronary intervention (PCI). The in-hospital and long-term prognostic significance of persistent fQRS was also evaluated. METHODS: In this retrospective study, 542 patients with a diagnose of STEMI underwent primary PCI were included. Study patients were divided into two groups according to the presence (n = 153) or absence (n = 389) of a fQRS on admission ECG. RESULTS: WMSI was found to be significantly higher in fQRS(+) group compared to the fQRS(-) group (P < 0.001). In multivariete analysis, WMSI was found to be an independent predictor of fQRS, and fQRS was inversely associated with LVEF. The in-hospital reinfarction (P = 0.003), MACE (P = 0.024), intraaortic balloon pump use (P = 0.014), and advanced heart failure (P < 0.001) were found to be significantly more frequent in the fQRS(+) group. The presence of fQRS on admission was found to be associated with an increase in long-term cardiovascular mortality (P = 0.028), and long-term all-cause mortality (P = 0.022). CONCLUSION: WMSI was significantly related with the presence of the fQRS, which reflects the linking between impairment of regional left ventricular systolic function and the presence of severe myocardial injury in STEMI.


Asunto(s)
Electrocardiografía/métodos , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Función Ventricular Izquierda/fisiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo
8.
Heart Surg Forum ; 18(2): E053-5, 2015 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-25924031

RESUMEN

Transcatheter valve implantation is a novel interventional technique, which was developed as an  alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/diagnóstico , Terapia Combinada/instrumentación , Terapia Combinada/métodos , Análisis de Falla de Equipo , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
9.
Vasa ; 44(4): 297-304, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26314362

RESUMEN

BACKGROUND: The aim of this study was to assess the periprocedural and one-year outcomes of two different cerebral protection systems used during carotid artery stenting (CAS). PATIENTS AND METHODS: We enrolled 90 consecutive patients with carotid artery stenosis who underwent CAS with a proximal flow blockage protection system (mean age 69.7 ± 8) or distal protection with a filter (mean age 70.8 ± 7). RESULTS: CAS was performed successively on 89 patients (99 %). Adverse events were defined as major stroke, minor stroke, transient ischemic attack (TIA), myocardial infarction, and death. Two strokes, one TIA, one death, and one myocardial infarction were observed in-hospital. There were no significant differences in safety or benefits between the proximal flow blockage embolic protection system (n = 45) and the distal filter protection system (n = 45) in terms of clinically apparent cerebral embolism, TIA, death, or myocardial infarction during the periprocedural stage or during the one-year follow-up period. CONCLUSIONS: Although it has been shown that the proximal flow blockage cerebral protection system decreases the risk of silent cerebral embolism, it has no advantage over the distal filter protection system in terms of adverse cerebrovascular or cardiac events during the periprocedural stage or during the long-term follow-up period.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Arteria Carótida Común/cirugía , Estenosis Carotídea/cirugía , Dispositivos de Protección Embólica , Cuidados Preoperatorios/instrumentación , Accidente Cerebrovascular/prevención & control , Anciano , Implantación de Prótesis Vascular/métodos , Imagen de Difusión por Resonancia Magnética , Femenino , Estudios de Seguimiento , Humanos , Masculino , Stents , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
10.
Med Sci Monit ; 20: 2020-6, 2014 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-25338525

RESUMEN

BACKGROUND: Elevated mean platelet volume may reflect presence of active large platelets, which lead to fatal or non-fatal cardiovascular events. In recent studies, lack of nocturnal blood pressure fall was presented as an independent predictor of poor prognosis in essential hypertension. The relation of raised MPV with left ventricular hypertrophy has also been reported in hypertension. The aim of this study was to investigate the relation between MPV, non-dipping blood pressure pattern, and left ventricular mass index (LVMI) in sustained hypertension. MATERIAL AND METHODS: A total of 2500 patients, whose ambulatory blood pressure (ABP) records had been evaluated retrospectively between January 2010 and December 2012, were included. Patients were divided into 3 groups according to their ABP values: non-dipper hypertensive (n=289), dipper hypertensive (n=255), and normotensive (n=306). The MPV levels and biochemical analyses were recorded from patient files and, LVMI were automatically calculated using a regression equation. RESULTS: The non-dipper and dipper hypertensive groups had significantly higher MPV levels than normotensives (8.4±1 fL, 8.3±1 fL, and 8.1±0.6 fL, respectively, p<0.001). However, there was no difference among the non-dipper and dipper groups in terms of MPV level (p=0.675). Although LVMI was significantly different between non-dipper, dipper, and normotensive groups (p=0.009), no correlation was found between MPV level and LVMI in dipper and non-dipper hypertensive patients (r=-0.080, p=0.142). There was a weak correlation between MPV level and ambulatory 24-h diastolic and systolic blood pressure (r=0.076, p=0.027, and r=0.073, p=0.033, respectively). CONCLUSIONS: We demonstrated that there was no correlation between MPV level, non-dipping pattern of blood pressure, and LVMI in sustained hypertension.


Asunto(s)
Plaquetas , Presión Sanguínea , Ventrículos Cardíacos/anatomía & histología , Hipertensión/sangre , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
11.
Blood Press ; 23(6): 349-55, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24919782

RESUMEN

OBJECTIVE: Left ventricular (LV) hypertrophy (LVH) predicts increased mortality in part due to an elevated incidence of sudden cardiac death in hypertension. The aim of the present study was to investigate the relation of microvolt T-wave alternans (MTWA) with different LV geometric patterns in patient with sustained hypertension. METHODS: This study consisted of 311 consecutive patients with sustained hypertension who were divided into four groups according to LV geometrical patterns. 90 patients were in the normal geometry group (NGG) [mean age 49.6 ± 7.8 years; 60 males (66.7%)], 99 patients were in the concentric remodeling group (CRG) [mean age 50.9 ± 6.6 years; 50 males (50.6%)], 63 patients were in the concentric hypertrophy group (CHG) [mean age 51.6 ± 7.3 years; 32 males (50.7%)] and 58 patients were in the eccentric hypertrophy group (EHG) [mean age 51.6 ± 9.0 years; 30 males (51.7%)]. Physical examination, laboratory work-up, office blood pressure measurement, transthoracic echocardiography and MTWA measurements were performed on all participants. RESULTS: MTWA positivity was significantly higher in EHG and CHG as compared to CRG and NGG (p < 0.001). Left ventricle mass index (LVMI), LV end-diastolic diameter (LVEDD), LV end-systolic diameter (LVESD), interventricular septum diameter (IVSd), posterior wall diameter (PWd) and office systolic blood pressure (SBP) were found to be significantly positively correlated with MTWA (all p-values < 0.05). CONCLUSION: We demonstrated that increased LVMI is associated with an elevated MTWA positivity in sustained hypertensives. Moreover, clinically significant LV geometric patterns including both concentric and eccentric hypertrophy are related with a raised MTWA positivity, which may lead to particular predilection to life-threatening ventricular arrhythmias and sudden cardiac death in sustained hypertension.


Asunto(s)
Hipertensión/fisiopatología , Hipertrofia Ventricular Izquierda/patología , Hipertrofia Ventricular Izquierda/fisiopatología , Adulto , Presión Sanguínea , Estudios Transversales , Ecocardiografía , Prueba de Esfuerzo , Femenino , Humanos , Hipertensión/patología , Masculino , Persona de Mediana Edad
12.
Arch Pharm (Weinheim) ; 347(6): 449-55, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24623369

RESUMEN

A series of new 1,2,4-triazole-3-one derivatives bearing the salicyl moiety were synthesized by using microwave irradiation, and their chemical structures were identified by IR, (1) H NMR, (13) C NMR, elemental analysis, and LC-MS. The anticonvulsant activities of the compounds 4a-c, 4e, and 5a-e were evaluated by the Anticonvulsant Screening Program of the National Institute of Health, USA. The compounds had moderate anticonvulsant activities in the maximum electroshock-induced seizure and minimal clonic seizure models in mice, without any neurotoxic effects.


Asunto(s)
Anticonvulsivantes/síntesis química , Anticonvulsivantes/farmacología , Salicilatos/síntesis química , Salicilatos/farmacología , Convulsiones/prevención & control , Triazoles/síntesis química , Triazoles/farmacología , Animales , Anticonvulsivantes/toxicidad , Modelos Animales de Enfermedad , Diseño de Fármacos , Electrochoque , Ratones , Estructura Molecular , Salicilatos/toxicidad , Convulsiones/etiología , Relación Estructura-Actividad , Factores de Tiempo , Triazoles/toxicidad
13.
J Clin Med ; 13(16)2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39200973

RESUMEN

Objectives: We aimed to evaluate the predictive importance of various clinical and laboratory parameters in the differential diagnosis of Acute Coronary Syndrome (ACS). Understanding these predictors is critical for improving diagnostic accuracy, guiding therapeutic decisions, and ultimately enhancing patient outcomes. Methods: The study included a total of 427 patients diagnosed with ACS, comprising 142 with unstable angina, 142 with non-ST elevation myocardial infarction (NSTEMI), and 143 with ST elevation myocardial infarction (STEMI). The data were collected from medical records of patients treated at a tertiary care hospital between January 2020 and December 2024. In addition to other biochemical parameters, triglyceride/HDL ratio (THR), triglyceride-glucose index (TGI), and Pan-Immune-Inflammation Value (PIV) were calculated and compared. Results: THR, TGI, PIV, and mortality rate were statistically higher in the STEMI group (p = 0.034, p = 0.031, p = 0.022, p = 0.045, respectively). The risk factors were found to be significantly associated with STEMI in the multiple logistic regression analysis and included age, total cholesterol, triglycerides, diabetes mellitus, smoking, cTnI, LVEF, THR, TGI, and PIV. High THR increases the risk of STEMI (AUC = 0.67, 95% CI: 0.62-0.72, p = 0.020). High THR increases the risk of mortality in ACS patients (AUC = 0.70, 95% CI: 0.65-0.75, p = 0.004). THRs above 3.5 are associated with higher risk. Sensitivity is 75% and specificity is 60%. High TGI increases the risk of mortality in ACS patients (AUC = 0.73, 95% CI: 0.68-0.78, p = 0.007). TGIs above 8.5 are associated with higher risk. Sensitivity is 78% and specificity is 63%. High PIVs increase the risk of mortality in ACS patients (AUC = 0.75, 95% CI: 0.70-0.80, p = 0.009). PIVs above 370 are associated with higher risk. Sensitivity is 80% and specificity is 65%. The combination of TGI, THR, PIV, and cTnI has the highest predictive capability over individual parameters for STEMI and mortality. Conclusions: We found that age, total cholesterol, triglycerides, cTnI, THR, TGI, and PIV increase, low LVEF, presence of diabetes mellitus, and smoking have predictive values for STEMI and mortality in patients with ACS. Unlike the studies in the literature, this is the first study in which cTnI, THR, TGI, and PIV values were evaluated together in ACS and mortality prediction.

14.
Clin Exp Hypertens ; 35(6): 396-400, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23148442

RESUMEN

Aortic stiffness is increased in patients with sustained hypertension (SH). The aim of this study was to investigate the relationship between aortic elastic properties and masked hypertension (MH). We evaluated aortic elastic properties in 35 individuals with MH, 35 patients with SH, and 35 normotensive healthy volunteers using transthoracic Doppler echocardiography. All aortic distensibility values were carried out at the same time or immediately after the blood pressure (BP) measurement. Baseline clinical and demographic characteristics of the patients were similar in all three groups. Aortic stiffness index and elastic modulus values were higher in MH group compared to SH group and control group (8.9 ± 6.3 vs. 5.4 ± 2.2 vs. 4.2 ± 2.5, P < .001 and 9.0 ± 6.3 vs. 6.4 ± 2.5 vs. 4.1 ± 2.4, P < .001, respectively). Aortic strain values were lower in MH group compared to SH group and control group (7.4 ± 5.3 vs. 9.5 ± 4.1 vs. 14.6 ± 7.1, P < .001, respectively). Aortic distensibility values were lower in MH and SH groups compared to controls (3.1 ± 1.9 vs. 3.7 ± 1.6 vs. 6.4 ± 3.4, P < .001, respectively). Furthermore, diastolic aortic diameter, left ventricular mass index, interventricular septum, and posterior wall thickness were higher in MH and SH groups when compared to controls. This study shows that masked hypertensive patients are at higher risk of "aortic" stiffness, a risk factor for cardiovascular morbidity and mortality, than normotensive and sustained hypertensive patients.


Asunto(s)
Aorta/fisiopatología , Hipertensión Enmascarada/fisiopatología , Rigidez Vascular/fisiología , Adulto , Aorta/diagnóstico por imagen , Presión Sanguínea , Estudios de Casos y Controles , Ecocardiografía Doppler , Elasticidad/fisiología , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertensión/diagnóstico por imagen , Hipertensión/fisiopatología , Masculino , Hipertensión Enmascarada/diagnóstico por imagen , Persona de Mediana Edad , Factores de Riesgo
15.
J Pak Med Assoc ; 63(9): 1186-8, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24601203

RESUMEN

Cardiac events due to lightning strike and their severity vary according to the strength of the electric current and the duration of exposure. The electrophysiological effects of lightning on the heart can result in ventricular fibrillation, asystole, QT prolongation, supraventricular tachycardia, and non-specific ST-T wave changes. In this report, a case of a patient who suffered myocardial infarction due to lightning strike is presented, which is a rare complication.


Asunto(s)
Traumatismos por Acción del Rayo/complicaciones , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/etiología , Adulto , Electrocardiografía , Resultado Fatal , Humanos , Masculino
16.
J Thromb Thrombolysis ; 33(4): 343-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22139027

RESUMEN

Heart failure (HF) is one of the most common and leading cause of death worldwide. Clinical trials provide evidence that the development of atrial fibrillation (AF) is a marker of poor prognosis in patients with HF. Furthermore, elevated D-dimer level is associated with increased cardiovascular mortality independent of AF in HF patients. We investigated whether plasma D-dimer levels in patients with hospitalized systolic HF could predict development of AF. A total of 150 consecutive patients with sinus rhythm who admitted to the emergency department with hospitalized systolic HF were evaluated. All hospitalized patients were obtained D-dimer levels within the first 24 h following admission. Atrial fibrillation developed in 31 (20.7%) patients during follow-up period of 6.3 ± 5 months. Patients who developed atrial fibrillation had significantly increased levels of D-dimer [608 (339-1,022) ng/ml versus 1,100 (608-2,599) ng/ml, P = 0.001]. Optimal cut-off level of D-dimer to predict development of AF was found to be >792 ng/ml. D-dimer >792 ng/ml, right ventricular dilatation, age, systolic pulmonary pressure, left atrium size, moderate to severe tricuspid regurgitation, and beta blocker usage were found to have prognostic significance in univariate analysis. In multivariate Cox proportional-hazards model, D-dimer levels >792 ng/ml (HR = 3.019, P = 0.006), and right ventricular dilatation (HR = 8.676, P = 0.003) were associated with an increased risk of new-onset AF. In conclusion, D-dimer could predict development of AF in patients with hospitalized systolic HF.


Asunto(s)
Fibrilación Atrial/sangre , Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Insuficiencia Cardíaca Sistólica/sangre , Factores de Edad , Anciano , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca Sistólica/complicaciones , Insuficiencia Cardíaca Sistólica/terapia , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
17.
Blood Press ; 21(5): 286-92, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22339477

RESUMEN

BACKGROUND: Sarcoidosis is an inflammatory granulomatous disease of unknown etiology that involves multiple organ systems. Many studies have shown a strong relationship between inflammation and atherosclerosis. The aim of this study is to investigate the relationship between elastic properties of the aorta and the duration of the disease in patients with sarcoidosis. METHOD: The study population included 52 patients with sarcoidosis (22 men, mean age = 42.7 ± 10.7 years, and mean disease duration = 38.8 ± 10.8 months) and 50 healthy control subjects (18 men, and mean age = 42.0 ± 8.0 years). Aortic stiffness (ß) index, aortic strain (AoS) and aortic distensibility (AoD) were calculated from the aortic diameters measured by transthoracic echocardiography and blood pressure obtained by sphygmomanometer. Cardiac functions were determined by using routine echocardiographic evaluation consist of standard two-dimensional and conventional Doppler and tissue Doppler imaging. RESULTS: The conventional echocardiographic parameters were similar between patients and controls. There were significant differences between the control and the patient groups in ß index (1.63 ± 0.55 vs 2.44 ± 1.54, p = 0.001), AoS (15.61 ± 5.69 vs 10.93 ± 4.11%, p < 0.001) and AoD (6.35 ± 2.64 vs 4.66 ± 1.98, 10 (-6) cm(2)/dyn, p = 0.001). There were statistically significant negative correlations between the disease duration and AoD (r = -0.46, p = 0.01) and AoS (r= -0.44, p = 0.002), whereas there was a positive correlation between the disease duration and ß index (r = 0.37, p = 0.01). In multivariate analysis, disease duration was significantly related with AoD, AoS and ß index (respectively, RR = 3.28, p = 0.002; RR = 3.03, p = 0.004; RR = 2.39, p = 0.02). CONCLUSION: We observed that elastic properties of the aorta alter in patients with sarcoidosis. We also have demonstrated a statistically significant correlation between aortic elastic properties and the disease duration.


Asunto(s)
Aorta/diagnóstico por imagen , Sarcoidosis/diagnóstico por imagen , Sarcoidosis/fisiopatología , Rigidez Vascular/fisiología , Adulto , Aorta/fisiopatología , Ecocardiografía/métodos , Ecocardiografía Doppler/métodos , Elasticidad , Femenino , Humanos , Masculino
18.
Lab Med ; 53(6): 590-595, 2022 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-35762784

RESUMEN

OBJECTIVE: To examine the immunoglobulin G-receptor-binding domain (IgG-RBD) response and changes in fibrinogen and D-dimer concentrations in individuals with a past coronavirus infection and followed by CoronaVac. METHODS: The study consisted of a total of 116 participants. Blood samples were drawn from subjects 21-25 days after they received first and second doses of CoronaVac as well as from individuals with a past infection. Fibrinogen, D-dimer, and IgG-RBD concentrations were measured. RESULTS: The IgG concentrations of the vaccinated subjects were significantly higher (P < .001), fibrinogen levels were lower (P < .001), and D-dimer levels increased following the second vaccination compared with the first vaccination (P = .083). No difference was obtained in IgG-RBD between vaccinated and previously infected individuals (P = .063). The differences in fibrinogen and D-dimer were statistically nonsignificant between both groups. CONCLUSION: The CoronaVac vaccine appears to be safe and effective. It is essential for individuals to take personal protective measures, such as using masks and distancing.


Asunto(s)
COVID-19 , Vacunas Virales , Humanos , Vacunas contra la COVID-19/efectos adversos , Fibrinógeno , Receptores de IgG , COVID-19/prevención & control , SARS-CoV-2 , Inmunoglobulina G
19.
Turk Kardiyol Dern Ars ; 39(6): 474-8, 2011 Sep.
Artículo en Turco | MEDLINE | ID: mdl-21918317

RESUMEN

OBJECTIVES: Although intracardiac echocardiography (ICE) has long been used for various cardiologic interventions, its utilization has been quite limited in Turkey. We assessed our experience with the use of ICE during transcatheter closure of secundum atrial septal defects (ASD). STUDY DESIGN: Fourteen patients (8 females, 6 males; mean age 34 years; range 15 to 62 years) underwent transcatheter device closure of ASD with ICE guidance. Before the procedure, 13 patients were examined by transesophageal echocardiography (TEE). Intracardiac echocardiography was used to evaluate the interatrial septum, defect size, the relationship of the septal occluder with neighboring structures before its release, and residual shunts after device release. RESULTS: Using short- and long-axis ICE images, the anteroposterior and superoinferior rims of the ASD, coronary sinus, and pulmonary vein openings were successfully visualized in all the patients. Defect diameters measured by ICE were closely correlated with those measured by TEE (97%) and balloon sizing (95%). The defects were closed successfully in 13 patients; the procedure was terminated in one patient due to the prolapse of both discs into the left atrium. There was no procedural complication. One patient experienced gastrointestinal hemorrhage that required blood transfusion two days after the procedure. No residual shunts were observed on follow-up transthoracic echocardiographic examinations one and six months after the procedure. CONCLUSION: Having high image quality and color Doppler features, ICE is quite functional in determining defect size, position of the septal occluder and its relationship with neighboring structures; thus, it is a reliable alternative to TEE which is used routinely in transcatheter closure of ASDs.


Asunto(s)
Cateterismo Cardíaco/métodos , Embolización Terapéutica , Defectos del Tabique Interatrial/terapia , Ultrasonografía Intervencional , Adolescente , Adulto , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Embolización Terapéutica/instrumentación , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Resultado del Tratamiento , Turquía/epidemiología , Adulto Joven
20.
Turk Kardiyol Dern Ars ; 39(4): 276-82, 2011 Jun.
Artículo en Turco | MEDLINE | ID: mdl-21646828

RESUMEN

OBJECTIVES: We investigated the effect of chronic kidney disease (CKD) on in-hospital results in patients undergoing primary percutaneous angioplasty for ST-segment elevation myocardial infarction (STEMI). STUDY DESIGN: The study included 2,486 patients (2,070 men, 416 women) who were treated with primary angioplasty for STEMI. Of these, 273 patients (11%) were found to have CKD (glomerular filtration rate <60 ml/min/1.73 m2) before the procedure. Patients with and without CKD were evaluated with respect to demographic and clinical features, primary angioplasty findings, and in-hospital clinical results. RESULTS: Patients with CKD exhibited a higher mean age, Killip class, and higher frequencies of female gender, diabetes, hypertension, anemia, and previous myocardial infarction (p<0.05). Angioplasty showed higher rates of right coronary artery lesion, multivessel disease, contrast nephropathy, unsuccessful procedure, and increased stenosis rate and stent length in CKD patients (p<0.05). Cardiovascular mortality occurred in 11.7% and 1.4% of patients with and without CKD, respectively (p<0.001). Patients with CKD had significantly higher incidences of target vessel revascularization, major cardiac events, stroke, cardiopulmonary resuscitation, hemodialysis, ventricular tachycardia/fibrillation, severe heart failure, cardiogenic shock, and significant hemorrhage (p<0.05). Multivariate analysis showed that CKD was an independent predictor of mortality (OR=4.1, 95% CI 1.83-9.17; p=0.001). CONCLUSION: Our findings show that CKD patients undergoing primary angioplasty for STEMI have an increased risk profile and poorer in-hospital results, and that CKD represents an independent risk factor for mortality.


Asunto(s)
Infarto del Miocardio/mortalidad , Infarto del Miocardio/terapia , Insuficiencia Renal Crónica/complicaciones , Angioplastia Coronaria con Balón , Arritmias Cardíacas/complicaciones , Comorbilidad , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Factores de Riesgo , Factores Sexuales , Resultado del Tratamiento , Turquía/epidemiología
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda