RESUMEN
ABSTRACT: Despite trends showing increases in the utilization of outpatient (OP) ambulatory surgery centers (ASCs) and decreases in the utilization of inpatient (IP) facilities for total knee arthroplasty (TKA) and total hip arthroplasty (THA), little is known about opioid prescribing for these procedures between each setting. This study evaluated differences in opioid prescribing and consumption between OP ASC and IP settings for elective TKA and THA surgeries over a 1-year period. Data collection also included pain and satisfaction of pain control postsurgery. In an OP ASC, analysis revealed a significant decrease in pills prescribed (p < .001, p < .001) and consumed (p < .001, p < .001) for TKA and THA, respectively. There was a significant decrease in the morphine equivalence units prescribed (p < .001, p < .001) and consumed (p < .001, p < .001) for TKA and THA, respectively. For TKA, pain was significantly lower (p = .018) and satisfaction of pain control was significantly higher (p = .007). For THA, pain (p = .374) and satisfaction of pain control (p = .173) were similar between the settings. Benefits of performing these surgeries in an OP ASC setting are patients having similar or lower levels of pain and having similar or higher satisfaction of pain control. Patients are also prescribed and consume less opioids. This has important implications for healthcare systems.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Analgésicos Opioides/uso terapéutico , Humanos , Pacientes Internos , Pacientes Ambulatorios , Dolor Postoperatorio/tratamiento farmacológico , Pautas de la Práctica en MedicinaRESUMEN
This study examined long-term survivorship of primary total hip arthroplasty (THA) using cementless Harris-Galante porous femoral and Harris-Galante porous I or II acetabular components. Of 113 hips (101 patients) studied, 60 hips (53 patients) were available for follow-up at a mean of 17.2 years after surgery. A total of 10 hips had documented revision, and 2 hips had failed radiographically. The average Harris hip score was 82. Radiographically, 12 hips demonstrated eccentric wear, 8 had osteolysis, and 1 had a broken tine. The overall survival rate was 87.7%; the mean volumetric wear rate was 74.96 mm(3); and the mean polyethylene linear penetration rate was 0.153 mm/y, similar to that of well-cemented THA in other series. This long-term outcome for an early-generation cementless THA is promising and provides a standard by which to judge the newer generation of cementless implants.
Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Tornillos Óseos , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Incidencia , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Estudios Prospectivos , Radiografía , Reoperación , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Venous thromboembolic events, either deep venous thrombosis or pulmonary embolism, are important complications in patients undergoing knee or hip arthroplasty. The purpose of this study was to evaluate the effectiveness of a mobile compression device (ActiveCare+S.F.T.) with or without aspirin compared with current pharmacological protocols for prophylaxis against venous thromboembolism in patients undergoing elective primary unilateral arthroplasty of a lower-extremity joint. METHODS: A multicenter registry was established to capture the rate of symptomatic venous thromboembolic events following primary knee arthroplasty (1551 patients) or hip arthroplasty (1509 patients) from ten sites. All patients were eighteen years of age or older with no known history of venous thromboembolism, coagulation disorder, or solid tumor. Use of the compression device began perioperatively and continued for a minimum of ten days. Patients with symptoms of deep venous thrombosis or pulmonary embolism underwent duplex ultrasonography and/or spiral computed tomography. All patients were evaluated at three months postoperatively to document any evidence of deep venous thrombosis or pulmonary embolism. RESULTS: Of 3060 patients, twenty-eight (0.92%) had venous thromboembolism (twenty distal deep venous thrombi, three proximal deep venous thrombi, and five pulmonary emboli). One death occurred, with no autopsy performed. Symptomatic venous thromboembolic rates observed in patients who had an arthroplasty of a lower-extremity joint using the mobile compression device were noninferior (not worse than), at a margin of 1.0%, to the rates reported for pharmacological prophylaxis, including warfarin, enoxaparin, rivaroxaban, and dabigatran, except in the knee arthroplasty group, in which the mobile compression device fell short of the rate reported for rivaroxaban by 0.06%. CONCLUSIONS: Use of the mobile compression device with or without aspirin for patients undergoing arthroplasty of a lower-extremity joint provides a noninferior risk for the development of venous thromboembolism compared with current pharmacological protocols.