Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Phys Rev Lett ; 112(2): 028301, 2014 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-24484045

RESUMEN

A bimolecular synthetic reaction (imine synthesis) was performed compartmentalized in micrometer-diameter emulsion droplets. The apparent equilibrium constant (Keq) and apparent forward rate constant (k1) were both inversely proportional to the droplet radius. The results are explained by a noncatalytic reaction-adsorption model in which reactants adsorb to the droplet interface with relatively low binding energies of a few kBT, react and diffuse back to the bulk. Reaction thermodynamics is therefore modified by compartmentalization at the mesoscale--without confinement on the molecular scale--leading to a universal mechanism for improving unfavorable reactions.


Asunto(s)
Química Orgánica/métodos , Iminas/síntesis química , Modelos Químicos , Adsorción , Aldehídos/química , Aminas/química , Química Orgánica/instrumentación , Difusión , Iminas/química , Cinética , Propiedades de Superficie , Termodinámica
2.
Sci Rep ; 13(1): 10162, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37349342

RESUMEN

A miniaturized V-band leaky-wave antenna (LWA) with circular polarization and backward-broadside-forward radiation based on a modified half-mode substrate integrated waveguide (M-HMSIW) is presented. The proposed M-HMSIW structure employs broadside coupled complementary split ring resonators to replace metallic vias, resulting in low-cost and fully-planar fabrication advantages over conventional HMSIWs. Each unit cell of the proposed LWA consists of an M-HMSIW in combination with two horizontal stubs and a cross-shaped complementary electric LC slot to provide a proper circular polarization with a composite right/left-handed property. Using this structure, the balanced condition can be obtained for the unit cell; hence a continuous backward-to-forward scanning, including broadside, is achieved. As a result, the proposed LWA with a radiator length of only 3.8 λ0 provides wide-angle beam scanning from - 53° to + 54° over the frequency range of 61.2 GHz to 73.4 GHz, while maintaining an excellent circular polarization between - 25° and 25°. The maximum gain of the LWA is 11.1 dB which is satisfactory, considering its compactness. The antenna's performance is experimentally verified, and close agreement between the simulations and measurements is observed.


Asunto(s)
Electricidad , Mano , Refracción Ocular
3.
Cureus ; 15(6): e40195, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37325689

RESUMEN

BACKGROUND: Reherniation rates following lumbar discectomy are low for most patients; however, patients with a large defect in the annulus fibrosis have a significantly higher risk of recurrence. Previous results from a randomized controlled trial (RCT) demonstrated that the implantation of a bone-anchored annular closure device (ACD) during discectomy surgery lowered the risk of symptomatic reherniation and reoperation over one year with fewer serious adverse events (SAEs) compared to discectomy alone. OBJECTIVE: The objective of this prospective, post-market, historically controlled study was to evaluate the use of an ACD during discectomy, and to confirm the results of the RCT that was used to establish regulatory approval in the United States. METHODS: In this post-market study, all patients (N = 55) received discectomy surgery with a bone-anchored ACD. The comparison population was patients enrolled in the RCT study who had discectomy with an ACD (N = 262) or discectomy alone (N = 272). All other eligibility criteria, surgical technique, device characteristics, and follow-up methodology were comparable between studies. Endpoints included rate of symptomatic reherniation or reoperation, SAEs, and patient-reported measures of disability, pain, and quality of life. RESULTS: Fifty-five patients received ACD implants at 12 sites between May 2020 and February 2021. In the previous RCT, 272 control patients had discectomy surgery alone (RCT-Control), and 262 patients had discectomy surgery with an ACD implant (RCT-ACD). Baseline characteristics across groups were typical of the overall population undergoing lumbar discectomy. The proportion of patients who experienced reherniation and/or reoperation was significantly lower in the ACD group compared to RCT-ACD and RCT-Control groups (p < 0.05). In the ACD study, the one-year rate of symptomatic reherniation was 3.7%, compared to 8.5% in the RCT-ACD group and 17.0% in the RCT-Control group. In the ACD group, the risk of reoperation was 5.5%, compared to 6.5% in the RCT-ACD group and 12.5% in the RCT-Control group. There were no device-related SAEs or device integrity failures in the ACD, and there were clinically meaningful improvements in patient-reported measures of disability, pain, and quality of life. CONCLUSION: In this post-market study of bone-anchored ACD in patients with large annular defects, rates of symptomatic reherniation, reoperation, and SAEs were all low. Compared to the RCT, the post-market ACD study demonstrated lower rates of reherniation and/or reoperation and measures of back pain one-year post-surgery.

4.
Int J Spine Surg ; 16(1): 168-175, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35217586

RESUMEN

BACKGROUND: This report documents 1-year results of 250 patients enrolled in a prospective, multicenter study of a minimally invasive (MI) sacroiliac joint fusion (SIJF) system that uses decortication, graft placement, and joint fixation. METHODS: The cohort includes all patients enrolled in the EVoluSIon (EVSI) clinical study who had MI SIJF surgery and completed 1-year follow-up. Average age at baseline was 60.5 years, and 70.8% were female. Sacroiliac (SI) joint-related pain duration was ≥2 years in 56% of patients. Visual analog scale (VAS) SI joint pain, Oswestry Disability Index (ODI), quality of life, and opioid use were assessed preoperatively and at 1 year. RESULTS: At 1 year, the mean VAS pain demonstrated a significant reduction of more than 43 points, from 76.4 at baseline to 33.0 (P < 0.0001), with 72.2% of patients attaining the minimal clinically important difference (MCID, ≥20-point improvement). Mean ODI scores also significantly improved from 54.4 at baseline to 30.5 at 1 year (P < 0.0001), with 62.5% of patients achieving the MCID (≥15-point improvement). Prior to surgery, 62.7% (126/201) of patients were taking opioids or other narcotics, but by 1 year postsurgery, only 26.9% (54/201) of patients reported using these medications, representing a significant 57.1% decrease in narcotic/opioid use (P < 0.0001). Fusion of the SI joint was seen in 68.7% of patients. Few procedural complications were reported. In all, there were 8 (8/250) serious procedure-related events, including 1 device malposition observed on the day of surgery that required replacing the superior screw with a shorter screw. CONCLUSIONS: Analysis of patients treated with MI SIJF in the EVSI study demonstrated that the procedure can be performed safely and results in significant improvements in pain, quality of life, and opioid use at 1 year as well as causing fusion in the majority of patients. CLINICAL RELEVANCE: MI SIJF differs from most procedures currently being performed in that it applies true orthopedic principles with decorticating, bone grafting, fusion, and placement of implants perpendicular to the joint for greatest stability. The 12-month data show improvement in functionality, reduction in pain, and, most notably, a reduction in narcotic usage, which is important considering the ongoing opioid epidemic.

5.
Sci Rep ; 12(1): 11234, 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35787647

RESUMEN

A hybrid technique is proposed to manipulate the field distribution in a substrate integrated waveguide (SIW) H-plane horn to enhance its radiation characteristics. The technique comprises two cascaded steps to govern the guided waves in the structure. The first step is to correct the phase of fields and form a quasi-uniform distribution in the flare section so that the gain increases and side-lobe-level (SLL) decreases. This is obtained by loading the structure with a novel modulated metal-via lens. Field expansion on the radiating aperture of the SIW H-plane horn generates backward surface waves on both broad walls which increases the backlobe. In the second step, these backward surface waves are recycled and directed forward with the aid of holography theory. This is achieved by adding a couple of dielectric slabs with holographic-based patterns of metallic strips on both broad walls. With this step, the backlobe is reduced and the endfire gain is further increased. Using the proposed technique, the structure is designed and fabricated to operate at [Formula: see text] GHz which simultaneously improves the measured values of gain to 11.65 dBi, H-plane SLL to [Formula: see text] dB, and front-to-back ratio to 17.02 dB.

6.
Biol Cell ; 103(1): 1-19, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20964627

RESUMEN

BACKGROUND INFORMATION: CtBPs [C-terminal (of E1A) binding protein] have roles in the nucleus as transcriptional co-repressors, and in the cytoplasm in the maintenance of vesicular membranes. CtBPs are expressed from two genes, CTBP1 and CTBP2, mRNA products of which are alternatively spliced at their 5'-ends to generate distinct protein isoforms. Extensive molecular and cellular analyses have identified CtBPs as regulators of pathways critical for tumour initiation, progression and response to therapy. However, little is known of the expression or regulation of CtBP isoforms in human cancer, nor of the relative contributions of CTBP1 and CTBP2 to the tumour cell phenotype. RESULTS: Expression of CtBP proteins and CTBP1 and CTBP2 mRNA splice forms in breast cancer cell lines and tumour tissue was examined. CtBP1 proteins are identifiable as a single band on Western blots and are ubiquitously detectable in breast tumour samples, by both Western blotting and immunohistochemistry. CtBP1 is present in six of six breast cancer cell lines, although it is barely detectable in SKBr3 cells due to reduced CTBP1 mRNA expression. In the cell lines, the predominant CTBP1 mRNA splice form encodes CtBP1-S protein; in tumours, both major CTBP1 mRNA splice forms are variably expressed. CtBP2 proteins are ubiquitously expressed in all lines and tumour samples. The predominant CTBP2 mRNA encodes CtBP2-L, although an alternatively spliced form that encodes CtBP2-S, previously unidentified in humans, is expressed at low abundance. Both CtBP2-L and CtBP2-S are readily detectable as two distinct bands on Western blots; here we show that the CTBP2-L mRNA is translated from two AUG codons to generate both CtBP2-L and CtBP2-S. We have also identified an autoregulatory feedback mechanism whereby CtBP protein abundance is maintained in proliferating breast cancer cells through the post-transcriptional regulation of CtBP2. This feedback is disrupted by UV-C radiation or exposure to cisplatin. Finally, we demonstrate that CtBP1 and CtBP2 both have p53-dependent and -independent roles in suppressing the sensitivity of breast cancer cells to mechanistically diverse cancer chemotherapeutic agents. CONCLUSIONS: These studies support recent evidence that CtBP family proteins represent potential targets for therapeutic strategies for the treatment of cancer in general, and breast cancer in particular.


Asunto(s)
Oxidorreductasas de Alcohol/metabolismo , Neoplasias de la Mama/genética , Proteínas de Unión al ADN/metabolismo , Resistencia a Antineoplásicos , Regulación Neoplásica de la Expresión Génica , Proteínas del Tejido Nervioso/metabolismo , Oxidorreductasas de Alcohol/genética , Antineoplásicos/farmacología , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/metabolismo , Línea Celular Tumoral , Proteínas Co-Represoras , Proteínas de Unión al ADN/genética , Femenino , Humanos , Proteínas del Tejido Nervioso/genética , Empalme del ARN
7.
Acta Neurochir (Wien) ; 153(3): 589-96, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21153669

RESUMEN

BACKGROUND: Minimally invasive percutaneous pedicle screw instrumentation methods may increase the need for intraoperative fluoroscopy, resulting in excessive radiation exposure for the patient, surgeon, and support staff. Electromagnetic field (EMF)-based navigation may aid more accurate placement of percutaneous pedicle screws while reducing fluoroscopic exposure. We compared the accuracy, time of insertion, and radiation exposure of EMF with traditional fluoroscopic percutaneous pedicle screw placement. METHODS: Minimally invasive pedicle screw placement in T8 to S1 pedicles of eight fresh-frozen human cadaveric torsos was guided with EMF or standard fluoroscopy. Set-up, insertion, and fluoroscopic times and radiation exposure and accuracy (measured with post-procedural computed tomography) were analyzed in each group. RESULTS: Sixty-two pedicle screws were placed under fluoroscopic guidance and 60 under EMF guidance. Ideal trajectories were achieved more frequently with EMF over all segments (62.7% vs. 40%; p = 0.01). Greatest EMF accuracy was achieved in the lumbar spine, with significant improvements in both ideal trajectory and reduction of pedicle breaches over fluoroscopically guided placement (64.9% vs. 40%, p = 0.03, and 16.2% vs. 42.5%, p = 0.01, respectively). Fluoroscopy time was reduced 77% with the use of EMF (22 s vs. 5 s per level; p < 0.0001) over all spinal segments. Radiation exposure at the hand and body was reduced 60% (p = 0.058) and 32% (p = 0.073), respectively. Time for insertion did not vary between the two techniques. CONCLUSIONS: Minimally invasive pedicle screw placement with the aid of EMF image guidance reduces fluoroscopy time and increases placement accuracy when compared with traditional fluoroscopic guidance while adding no additional time to the procedure.


Asunto(s)
Tornillos Óseos , Campos Electromagnéticos , Fluoroscopía/instrumentación , Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Neuronavegación/instrumentación , Dosis de Radiación , Fusión Vertebral/instrumentación , Vértebras Torácicas/cirugía , Diseño de Equipo , Fluoroscopía/efectos adversos , Humanos , Evaluación de Procesos y Resultados en Atención de Salud , Estudios de Tiempo y Movimiento
8.
Int J Spine Surg ; 15(s2): S10-S20, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34607916

RESUMEN

Image guidance (IG) and robotic-assisted (RA) surgery are modern technological advancements that have provided novel ways to perform precise and accurate spinal surgery. These innovations supply real-time, three-dimensional imaging information to aid in instrumentation, decompression, and implant placement. Although nothing can replace the knowledge and expertise of an experienced spine surgeon, these platforms do have the potential to supplement the individual surgeon's capabilities. Specific advantages include more precise pedicle screw placement, minimally invasive surgery with less reliance on intraoperative fluoroscopy, and lower radiation exposure to the surgeon and staff. As these technologies have become more widely adopted over the years, novel uses such as tumor resection have been explored. Disadvantages include the cost of implementing IG and robotics platforms, the initial learning curve for both the surgeon and the staff, and increased patient radiation exposure in scoliosis surgery. Also, given the relatively recent transition of many procedures from inpatient settings to ambulatory surgery centers, access to current devices may be cost prohibitive and not as readily available at some centers. Regarding patient-related outcomes, much further research is warranted. The short-term benefits of minimally invasive surgery often bolster the perioperative and early postoperative outcomes in many retrospective studies on IG and RA surgery. Randomized controlled trials limiting such confounding factors are warranted to definitively show potential independent improvements in patient-related outcomes specifically attributable to IG and RA alone. Nonetheless, irrespective of these current unknowns, it is clear that these technologies have changed the field and the practice of spine surgery. Surgeons should be familiar with the potential benefits and tradeoffs of these platforms when considering adopting IG and robotics in their practices.

9.
Neurosurgery ; 88(3): 497-505, 2021 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-33372218

RESUMEN

BACKGROUND: Short- and mid-term studies have shown the effectiveness of cervical disc arthroplasty (CDA) to treat cervical disc degeneration. OBJECTIVE: To report the 10-yr outcomes of a multicenter experience with cervical arthroplasty for 1- and 2-level pathology. METHODS: This was a prospective study of patients treated with CDA at 1 or 2 contiguous levels using the Mobi-C® Cervical Disc (Zimmer Biomet). Following completion of the 7-yr Food and Drug Administration postapproval study, follow-up continued to 10 yr for consenting patients at 9 high-enrolling centers. Clinical and radiographic endpoints were collected out to 10 yr. RESULTS: At 10 yr, patients continued to have significant improvement over baseline Neck Disability Index (NDI), neck and arm pain, neurologic function, and segmental range of motion (ROM). NDI and pain outcomes at 10 yr were significantly improved from 7 yr. Segmental and global ROM and sagittal alignment also were maintained from 7 to 10 yr. Clinically relevant adjacent segment pathology was not significantly different between 7 and 10 yr. The incidence of motion restricting heterotopic ossification at 10 yr was not significantly different from 7 yr for 1-level (30.7% vs 29.6%) or 2-level (41.7% vs 39.2%) patients. Only 2 subsequent surgeries were reported after 7 yr. CONCLUSION: Our results through 10 yr were comparable to 7-yr outcomes, demonstrating that CDA with Mobi-C continues to be a safe and effective surgical treatment for patients with 1- or 2-level cervical degenerative disc disease.


Asunto(s)
Artroplastia/tendencias , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/cirugía , Adulto , Artroplastia/métodos , Femenino , Estudios de Seguimiento , Humanos , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/cirugía , Masculino , Persona de Mediana Edad , Dolor de Cuello/diagnóstico por imagen , Dolor de Cuello/cirugía , Estudios Prospectivos , Rango del Movimiento Articular/fisiología , Factores de Tiempo , Reeemplazo Total de Disco/métodos , Reeemplazo Total de Disco/tendencias , Resultado del Tratamiento
10.
Cureus ; 13(12): e20274, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35018268

RESUMEN

Background Patients with large defects in the annulus fibrosus following lumbar discectomy have high rates of symptomatic reherniation and reoperation. An FDA randomized controlled trial (RCT) with a bone-anchored device (Barricaid, Intrinsic Therapeutics, Woburn, MA) that occludes the annular defect reported significantly lower risk of symptomatic reherniation and reoperation compared to patients receiving discectomy only. However, results of the Barricaid device in real-world use remain limited.  Methods This was a post-market study to determine the real-world outcomes of the Barricaid device when used in addition to primary lumbar discectomy in patients with large annular defects. Main outcomes included leg pain severity, Oswestry Disability Index (ODI), adverse events, symptomatic reherniation, and reoperation. Imaging studies were read by an independent imaging core laboratory. This paper reports the initial three-month primary endpoint results from the trial; one-year patient follow-up is ongoing. Results Among 55 patients (mean age 41±13 years, 60% male), the mean percent reduction in leg pain severity was 92%, and the mean percent reduction in ODI score was 79%. The three-month rate of symptomatic reherniation was 3.6% and the rate of reoperation was 1.8%. The serious adverse event rate was 5.5%; no device migrations or fractures were observed.  Conclusion Among patients with large annular defects following lumbar discectomy treated with the Barricaid device in real-world conditions, early results demonstrated clinically meaningful improvements in patient symptoms and low rates of symptomatic reherniation, reoperation, and complications, which were comparable to those observed with the device in an FDA-regulated trial.

11.
Int J Spine Surg ; 14(6): 860-895, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33560247

RESUMEN

The index 2014 International Society for the Advancement of Spine Surgery Policy Statement-Minimally Invasive Surgical Sacroiliac Joint Fusion-was generated out of necessity to provide an International Classification of Diseases, Ninth Revision (ICD-9)-based background and emphasize tools to ensure correct diagnosis. A timely ICD-10-based 2016 update provided a granular threshold selection with improved level of evidence and a more robust and relevant database (Appendix Table A1). As procedures and treatment options have evolved, this 2020 update reviews and analyzes the expanding evidence base and provides guidance relating to differences between the lateral and dorsal surgical procedures for minimally invasive surgical sacroiliac joint fusion.

12.
Global Spine J ; 10(3): 332-345, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32313799

RESUMEN

STUDY DESIGN: Systematic review. OBJECTIVES: Superiority claims for medical devices are commonly derived from noninferiority trials, but interpretation of such claims can be challenging. This study aimed to (a) establish the prevalence of noninferiority and superiority designs among spinal device trials, (b) assess the frequency of post hoc superiority claims from noninferiority studies, and (c) critically evaluate the risk of bias in claims that could translate to misleading conclusions. METHODS: Study bias was assessed using the Cochrane Risk of Bias Tool. The risk of bias for the superiority claim was established based on post hoc hypothesis specification, analysis of the intention-to-treat population, post hoc modification of a priori primary outcomes, and sensitivity analyses. RESULTS: Forty-one studies were identified from 1895 records. Nineteen (46%) were noninferiority trials. Fifteen more (37%) were noninferiority trials with a secondary superiority hypothesis specified a priori. Seven (17%) were superiority trials. Of the 34 noninferiority trials, 14 (41%) made superiority claims. A medium or high risk of bias was related to the superiority claim in 9 of those trials (64%), which was due to the analyzed population, lacking sensitivity analyses, claims not being robust during sensitivity analyses, post hoc hypotheses, or modified endpoints. Only 4 of the 14 (29%) noninferiority studies provided low bias in the superiority claim, compared with 3 of the 5 (60%) superiority trials. CONCLUSIONS: Health care decision makers should carefully evaluate the risk of bias in each superiority claim and weigh their conclusions appropriately.

13.
Int J Spine Surg ; 14(1): 1-17, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32128297

RESUMEN

Lumbar disc herniation (LDH) is a frequent cause of low back pain and radiculopathy, disability, and diminution in quality of life. While nonsurgical care remains the mainstay of initial treatment, symptoms that persist for prolonged periods of time are well treated with discectomy surgery. A large body of evidence shows that, in patients with unremitting symptoms despite a reasonable period of nonsurgical treatment, discectomy surgery is safe and efficacious. In patients with symptoms lasting greater than 6 weeks, various forms of discectomy (open, microtubular, and endoscopic) are superior to continued nonsurgical treatment. The small but significant proportion of patients with recurrent disc herniation experience less improvement overall than patients who do not experience reherniation after primary discectomy. Lumbar discectomy patients with large annular defects (≥6 mm wide) are at a higher risk for recurrent herniation and revision surgery. Annular closure via a bone-anchored device has been shown to decrease the rate of recurrent disc herniation and associated reoperation in these high-risk patients. After a detailed review of the literature, current clinical evidence supports discectomy (open, microtubular, or endoscopic discectomy) as a medically necessary procedure for the treatment of LDH with radiculopathy in indicated patients. Furthermore, there is new scientific evidence that supports the use of bone-anchored annular closure in patients with large annular defects, who are at greater risk for recurrent disc herniation.

14.
Caspian J Intern Med ; 11(2): 143-149, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32509241

RESUMEN

BACKGROUND: To investigate the possibility that the eradication of H pylori infection is associated with a reduction in the risk of glaucoma. METHODS: Sixty-five successive patients with elevated intraocular pressure (IOP) or glaucoma were included in the study. Serum samples from all subjects were analyzed for the presence of H pylori- antibodies using ELISA. Forty patients with positive serologic test were included. Half of the patients enrolled into intervention group and the other half registered as control. Intervention arm was referred to the Gastroenterology Clinic for eradication of H pylori and evaluated for the effect of H pylori regimen eradication on IOP and glaucoma over 2 months of follow-up. The age-matched controls did not receive treatment. Urea breath test was applied to confirm eradication. RESULTS: There was a significant (p=0.005) reduction in IOP after complete eradication in the intervention group. This value was not significant in control patients (p=0.08). The mean IOP before treatment of glaucoma in the control group was 23.60±2.37 mmHg and after treatment with anti-glaucoma drugs was 14.25±1.48 mmHg on the onset of study, and 13.55±2.01 mmHg after follow up. The mean IOP before treatment of glaucoma in the intervention group was 24.55±3.6 mmHg and after treatment with anti-glaucoma drugs was 15.15±1.8 mmHg, and 14.3±1.6 mmHg after the eradication of H pylori with a drug regimen. However, after the treatment of glaucoma in all patients, the overall comparison of mean IOP differences showed no statistical difference (P=0.65). CONCLUSION: H pylori eradication therapy may have a positive effect on the management of glaucoma.

15.
Lab Chip ; 9(20): 2902-8, 2009 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-19789742

RESUMEN

Microdroplets in water-in-oil emulsions can be used as microreactors with volumes 10(3) to 10(9) times smaller than the smallest working volumes in a microtitre plate well (1-2 microL). However, many reactions and assays require multiple steps where new reagents are added at defined times, to start, modify or terminate a reaction. The most flexible way to add new reagents to pre-formed droplets is by controlled, pairwise droplet fusion. We describe a droplet-based microfluidic system capable of performing multiple operations, including pairwise droplet fusion, to analyze complex and sequential multi-step reactions. It is exemplified by performing a series of six on-chip and two off-chip operations which enable the coupled in vitro transcription and translation of cotA laccase genes in droplets and, after performing a controlled fusion with droplets containing laccase assay reagents, the end-point and kinetic analysis of the catalytic activity of the translated protein. In vitro translation and the laccase assay must be performed sequentially as the conditions for the laccase assay are not compatible with in vitro translation. Droplet fusion was performed by electrocoalescence at a rate of approximately 3000 fusion events per second and nearly 90% of droplets were fused one-to-one (one droplet containing in vitro translated laccase fused to one droplet containing the reagents for the laccase assay). The ability to uncouple the enzymatic assay from in vitro translation greatly extends the range of activities of in vitro translated proteins that can potentially be screened in droplet-based microfluidic systems. Furthermore, the system also opens up the possibility of performing a wide range of other new (bio)chemical reactions in droplets.


Asunto(s)
Bacillus subtilis/enzimología , Lacasa/metabolismo , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Expresión Génica , Cinética , Lacasa/genética , Tamaño de la Muestra
16.
Am J Physiol Renal Physiol ; 297(5): F1324-9, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19726543

RESUMEN

To understand how rapid changes in blood pressure can regulate Na-K-ATPase in the kidney cortex, we tested the hypothesis that a short-term (5 min) decrease in renal perfusion pressure will increase the amount of Na-K-ATPase in the plasma membranes by an angiotensin II-dependent mechanism. The abdominal aorta of anesthetized Sprague-Dawley rats was constricted with a ligature between the renal arteries, and pressure was monitored on either side during acute constriction. Left renal perfusion pressure was reduced to 70 +/- 1 mmHg (n = 6), whereas right renal perfusion pressure was 112 +/- 4 mmHg. In control (nonconstricted) rats (n = 5), pressure to both kidneys was similar at 119 +/- 6 mmHg. After 5 min of reduced perfusion, femoral venous samples were taken for plasma renin activity (PRA) and the kidneys excised. The cortex was dissected, minced, sieved, and biotinylated. Lower perfusion left kidneys showed a 41% increase (P < 0.003) in the amount of Na-K-ATPase in the plasma membrane compared with right kidneys. In controls, there was no difference in cell surface Na-K-ATPase between left and right kidneys (P = 0.47). PRA was 57% higher in experimental animals compared with controls. To test the role of angiotensin II in mediating the increase in Na-K-ATPase, we repeated the experiments (n = 6) in rats treated with ramiprilat. When angiotensin-converting enzyme was inhibited, the cell surface Na-K-ATPase of the two kidneys was equal (P =0.46). These results confirm our hypothesis: rapid changes in blood pressure regulate trafficking of Na-K-ATPase in the kidney cortex.


Asunto(s)
Angiotensina II/fisiología , Membrana Celular/enzimología , Corteza Renal/irrigación sanguínea , Corteza Renal/enzimología , Circulación Renal/fisiología , ATPasa Intercambiadora de Sodio-Potasio/metabolismo , Angiotensina II/biosíntesis , Inhibidores de la Enzima Convertidora de Angiotensina/farmacología , Animales , Biotina/metabolismo , Presión Sanguínea/fisiología , Técnicas In Vitro , Masculino , Microsomas/enzimología , Ramipril/análogos & derivados , Ramipril/farmacología , Ratas , Ratas Sprague-Dawley , Flujo Sanguíneo Regional/efectos de los fármacos , Renina/sangre , Renina/fisiología
17.
Anal Chem ; 81(12): 4813-21, 2009 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19518143

RESUMEN

We have developed a method for high-throughput isothermal amplification of single DNA molecules in a droplet-based microfluidic system. DNA amplification in droplets was analyzed using an intercalating fluorochrome, allowing fast and accurate "digital" quantification of the template DNA based on the Poisson distribution of DNA molecules in droplets. The clonal amplified DNA in each 2 pL droplet was further analyzed by measuring the enzymatic activity of the encoded proteins after fusion with a 15 pL droplet containing an in vitro translation system.


Asunto(s)
ADN/análisis , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas de Amplificación de Ácido Nucleico/métodos , Sustancias Intercalantes/química , Técnicas Analíticas Microfluídicas/métodos , Temperatura
18.
Int J Spine Surg ; 12(5): 582-586, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30364829

RESUMEN

BACKGROUND: Performing an adequate transforaminal lumbar interbody fusion (TLIF) discectomy requires numerous instrument passes, increasing surgical time and the risk of complications. The purpose of this study was to evaluate the efficacy and efficiency of discectomy and endplate preparation during TLIF using traditional manual instrumentation versus a novel suction discectomy curette. The direct economic benefit with use of the suction discectomy curette is calculated. METHODS: Three experienced, spine-fellowship-trained surgeons performed TLIF discectomies on 3 cadaveric specimens from T12 to S1 using either traditional manual discectomy instruments or CONCORD Clear (Xtool) devices supplemented with manual discectomy instruments. For each level in which a discectomy was performed, the following were measured: elapsed time, number of instrument passes and the number of instrument exchanges, and estimated tissue volume. RESULTS: Transforaminal lumbar interbody fusion discectomy times improved on average 11:32 minutes per level, which equates to an estimated procedural time savings of 15:85 minutes, using 1.4 levels per TLIF, the average number of levels in a large series. Usage of the CONCORD Clear significantly reduced instrument passes compared to traditional, with a mean of 62.0 for traditional versus 7.1 for CONCORD Clear, an 8.7-fold improvement. Instrument exchanges showed a 5.9-fold improvement, with means of 26.8 and 4.6, respectively. Wet discectomy tissue volume was measured for each discectomy, with a mean of 5.4 cc for traditional versus 12.9 cc for CONCORD Clear, a 2.4-fold improvement. CONCLUSIONS: This study estimates that, in a typical TLIF procedure, over 15 minutes should be saved by using the CONCORD Clear l device (a quarter of the time of a traditional discectomy), and by considering the direct cost-benefit associated with this time savings as well as reduced sterilization costs, it is estimated that a hospital could save approximately $1300 in operating room time and sterilization cost with the use of the CONCORD Clear device in a typical 1-level TLIF procedure.

19.
Open Orthop J ; 11: 1440-1448, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29387289

RESUMEN

PURPOSE: This report documents six-month results of the first 50 patients treated in a prospective, multi-center study of a minimally invasive (MI) sacroiliac (SI) joint fusion system. PATIENTS AND METHODS: This cohort includes 50 patients who had MI SI joint fusion surgery and completed 6 month follow-up. Average age at baseline was 61.5, 58% were female, and SI joint-related pain duration was ≥2yrs in 54.0% of patients. Visual Analog Scale (VAS) SI joint pain, Oswestry Disability Index (ODI), quality of life and opioid use were assessed preoperatively and at 6 months. RESULTS: At 6 months, mean VAS pain demonstrated a significant reduction from 76.2 at baseline to 35.1 (54% reduction, p<0.0001), with 72% of patients attaining the minimal clinically important difference (MCID, ≥20 point improvement). Mean ODI improved from 55.5 to 35.3 at 6 months (p < 0.001), with 56% of patients achieving the MCID (≥15 point improvement). Prior to surgery 33/50 (66%) of patients were taking opioids, but by 6 months the number of patients taking opioids had decreased by 55% to 15/50 (30%). Few procedural complications were reported. Two procedure-related events required hospitalization: a revision procedure (2%) for nerve impingement and one case of ongoing low back pain. CONCLUSION: Analysis of patients treated with MI SI joint fusion using the SImmetry System demonstrated that the procedure can be performed safely and results in significant improvements in pain, disability, and opioid use at 6 months. Longer term follow-up in this study will determine whether these improvements are durable, as well as the associated radiographic fusion rates.

20.
Crit Care ; 10(2): R64, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16630359

RESUMEN

INTRODUCTION: Blood pressure measurements frequently guide management in critical care. Direct readings, commonly from a major artery, are considered to be the gold standard. Because arterial cannulation is associated with risks, alternative noninvasive blood pressure (NIBP) measurements are routinely used. However, the accuracy of NIBP determinations in overweight patients in the outpatient setting is variable, and little is known about critically ill patients. This prospective, observational study was performed to compare direct intra-arterial blood pressure (IABP) with NIBP measurements obtained using auscultatory and oscillometric methods in overweight patients admitted to our medical intensive care unit. METHOD: Adult critically ill patients with a body mass index (BMI) of 25 kg/m2 or greater and a functional arterial line (assessed using the rapid flush test) were enrolled in the study. IABP measurements were compared with those obtained noninvasively. A calibrated aneroid manometer (auscultatory technique) with arm cuffs compatible with arm sizes and a NIBP monitor (oscillometric technique) were used for NIBP measurements. Agreement between methods was assessed using Bland-Altman analysis. RESULTS: Fifty-four patients (23 males) with a mean (+/- standard error) age of 57 +/- 3 years were studied. The mean BMI was 34.0 +/- 1.4 kg/m2. Mean arm circumference was 32 +/- 0.6 cm. IABP readings were obtained from the radial artery in all patients. Only eight patients were receiving vasoactive medications. Mean overall biases for the auscultatory and oscillometric techniques were 4.1 +/- 1.9 and -8.0 +/- 1.7 mmHg, respectively (P < 0.0001), with wide limits of agreement. The overestimation of blood pressure using the auscultatory technique was more important in patients with a BMI of 30 kg/m2 or greater. In hypertensive patients both NIBP methods underestimated blood pressure as determined using direct IABP measurement. CONCLUSION: Oscillometric blood pressure measurements underestimated IABP readings regardless of patient BMI. Auscultatory measurements were also inaccurate, tending to underestimate systolic blood pressure and overestimate mean arterial and diastolic blood pressure. NIBP can be inaccurate among overweight critically ill patients and lead to erroneous interpretations of blood pressure.


Asunto(s)
Presión Sanguínea/fisiología , Enfermedad Crítica , Sobrepeso/fisiología , Determinación de la Presión Sanguínea/métodos , Monitores de Presión Sanguínea , Índice de Masa Corporal , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda