1.
Artif Organs ; 39(8): 670-80, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26234448

RESUMEN

Severe cardiac failure patients require a total artificial heart (TAH) to save life. To realize a TAH that can fit a body of small stature and has high performance, high durability, good anatomical fitting, good blood compatibility, and physiological control, we have been developing the helical flow TAH (HFTAH) with two helical flow pumps with hydrodynamic levitation impeller. Animal experiments of the HFTAH were conducted to perform in vivo studies. The HFTAH was implanted in 13 adult female goats weighing 45.0-64.0 kg. After surgery, neither anti-coagulant nor anti-platelet medication was given systemically. The HFTAH was usually driven with a quasi-pulsatile mode. The 1/R control or ΔP control was applied to control the circulation. The ΔP control is a new method using simplified equation of the 1/R control. The HFTAH could be implanted in all goats with good anatomical fitting. Two goats survived for a long time (100 and 68 days). Major causes of termination were device failure and surgical complications. In the device failure, trouble with hydrodynamic bearing was conspicuous. In the two long-term survived goats, experiments were terminated with bearing instability that was probably caused by the suction effect. In these goats, hemolysis occurred on postoperative day 88 and 44, which was considered to be relevant to the bearing trouble. Thrombus was found at the broken right bearing of the 100-day survived goat. However, antithrombogenicity of the pump is expected to be good unless bearing trouble occurs. In two long-term survived goats, the 1/R control or ΔP control worked appropriately to prevent the elevation of right atrial pressure. In both goats, hemodynamic parameters changed with the condition of the animals, liver and kidney functions remained almost normal except when recovering from surgery and during hemolysis, and total protein recovered 2 weeks after surgery. Although instability of the hydrodynamic bearing should be improved, performance of the HFTAH with physiological control could be demonstrated.


Asunto(s)
Corazón Artificial , Hemodinámica , Animales , Femenino , Cabras , Hemólisis , Ensayo de Materiales , Modelos Animales , Diseño de Prótesis , Falla de Prótesis , Flujo Pulsátil , Factores de Tiempo
2.
J Artif Organs ; 18(3): 206-12, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25784463

RESUMEN

The helical flow pump (HFP) was invented to be an ideal pump for developing the TAH and the helical flow TAH (HFTAH) using two HFPs has been developed. However, since the HFP is quite a new pump, hydrodynamic characteristics inside the pump are not clarified. To analyze hydrodynamic characteristics of the HFP, flow visualization study using the particle image velocimetry and computational fluid dynamics analysis were performed. The experimental and computational models were developed to simulate the left HFP of the HFTAH and distributions of flow velocity vectors, shear stress and pressure inside the pump were examined. In distribution of flow velocity vectors, the vortexes in the vane were observed, which indicated that the HFP has a novel and quite unique working principle in which centrifugal force rotates the fluid in the helical volutes and the fluid is transferred from the inlet to the outlet helical volutes according to the helical structure. In distribution of shear stress, the highest shear stress that was considered to be occurred by the shunt flow across the impeller was found around the entrance of the inlet helical volute. However, it was not so high to cause hemolysis. This shunt flow is thought to be improved by redesigning the inlet and outlet helical volutes. In distribution of pressure, negative pressure was found near the entrance of the inlet helical volute. However, it was not high. Negative pressure is thought to be reduced with an improvement in the design of the impeller or the vane shape.


Asunto(s)
Circulación Asistida/instrumentación , Corazón Artificial , Simulación por Computador , Diseño de Equipo , Hemorreología , Humanos , Modelos Cardiovasculares , Reología , Estrés Mecánico
3.
Artículo en Inglés | MEDLINE | ID: mdl-24109776

RESUMEN

The present control method used in our helical flow total artificial heart (HFTAH) would only need four parameters. Nowadays, gauge pressure sensors are being used to obtain the pressure needed for control parameters. Nevertheless, there are also many following problems such as calibration, maintenance, offset drift and infection due to the skin-penetrative lines for the usage of gauge pressure sensor. Therefore, it is preferable to find another substitutional way instead of the gauge sensor to measure the pressure. In addition, with an eye to completing an implantable HFTAH, we would like to do without any lines through the experiment animal. Therefore, it was confirmed in this study that whether there is a relation between the left atrial pressure (LAP) and its pulse pressure (amplitude). Subsequently the mean value of LAP and its amplitude were quantified. There are two methods used in this study to process the data. Method one, frequency spectrum analysis, is to quantify the signals by getting the absolute value of amplitude for a fixed heartbeat analysis. Method two, by using the synchronous detection method, it is postulated to be more applicable to variant heartbeat data with 1/R control. By the relation of LAP and the pulse pressure acquired in the above two methods, as long as the amplitude of LAP is known by the absolute pressure sensor, it's able to obtain the mean value of LAP (for it suggests a linear relation). Therefore the characteristic could substitute one of the control parameter (that is the LAP), and the other three parameters will be acquired by estimation thus it doesn't need to measure them additionally. Consequently, it is expected that acquiring LAP by absolute pressure sensor for one of the control parameters could attain to an implantable HFTAH.


Asunto(s)
Corazón Artificial , Animales , Presión Atrial , Presión Sanguínea , Retroalimentación , Frecuencia Cardíaca , Humanos , Modelos Cardiovasculares
4.
Artículo en Inglés | MEDLINE | ID: mdl-24110289

RESUMEN

To realize a total artificial heart (TAH) with high performance, high durability, good anatomical fitting, and good blood compatibility, the helical flow TAH (HFTAH) has been developed with two helical flow pumps having hydrodynamic levitation impeller. The HFTAH was implanted in goats to investigate its anatomical fitting, blood compatibility, mechanical stability, control stability, and so on. The size of the HFTAH was designed to be 80 mm in diameter and 84 mm wide. The maximum output was 19 L/min against 100 mmHg of pressure head. Eight adult female goats weighting from 45 to 56.3 kg (average 49.7 kg) were used. Under the extracorporeal circulation, natural heart was removed at the atrioventricular groove and the HFTAH was implanted. The HFTAH was driven with a pulsatile mode. The 1/R control was applied when the right atrial pressure recovered. The HFTAH could be implanted with good anatomical fitting in all goats. Two goats survived for more than a week. One goat is ongoing. Other goats did not survive for more than two days with various reasons. In the goats that survived for more than a week, the hydrodynamic bearing was worn and broken, which indicated that the bearing touched to the shaft. The cause was supposed to be the influence of the sucking effect. The potential of the HFTAH could be demonstrated with this study. The stability of the hydrodynamic bearing in a living body, especially the influence of the sucking effect, was considered to be very important and a further study should be necessary.


Asunto(s)
Corazón Artificial , Hemorreología/fisiología , Diseño de Prótesis , Implantación de Prótesis , Animales , Presión Sanguínea , Femenino , Cabras
5.
Artículo en Inglés | MEDLINE | ID: mdl-24110290

RESUMEN

The helical flow pump (HFP) is newly developed blood pomp for total artificial heart (TAH). HFP can work with lower rotational speed than axial and centrifugal blood pump. It can be seen reasonable feature to generate pulsatile flow because high response performance can be realized. In this article, pulsatility of HFP was evaluated using mock circulation loop. Pulsatile flow was generated by modulating the rotational speed in various amplitude and heart rate. In the experiment, relationship between Pump flow, pump head, rotational speed amplitude, heart rate and power consumption is evaluated. As the result, complete pulsatile flow with mean flow rate of 5 L/min and mean pressure head of 100 mmHg can be obtained at ± 500 rpm with mean rotational speed of 1378 to 1398 rpm in hart rate from 60 to 120. Flow profiles which are non-pulsatile, quasi-pulsatile or complete flow can be adjusted arbitrarily. Therefore, HFP has excellent pulsatility and control flexibility of flow profile.


Asunto(s)
Corazón Auxiliar , Hemorreología , Diseño de Prótesis , Flujo Pulsátil/fisiología , Frecuencia Cardíaca/fisiología , Hidrodinámica , Rotación
6.
Artículo en Inglés | MEDLINE | ID: mdl-24111039

RESUMEN

Development have been achieved of a new blood pump for next generation Percutaneous Cardio-Pulmonary Support (PCPS) system and a novel surface coating method for silicone membrane hollow fiber by physical adsorption using a copolymer composed of a 2-Methacryloyloxyethyl phosphorylcholine (MPC) unit and a hydrophobic unit. The new blood pump, named the Troidal Convolution Pump (TCP), is based on the principle of a cascade pump and perfused 5 L/min and 350 mmHg at 2450 rpm. The novel copolymer composed of 30% MPC unit and 3-(methacryloyloxy) propyltris (trimethylsiloxy) silane (MPTSSi) unit (PMMSi30) was the most suitable molecular design on a silicone surface. The PMMSi30 coated surface adsorbed 7.2 % as much protein a non-coated surface adsorbed.


Asunto(s)
Máquina Corazón-Pulmón , Sistemas de Manutención de la Vida/instrumentación , Materiales Biocompatibles Revestidos , Humanos , Cuidados para Prolongación de la Vida , Oxigenadores de Membrana