Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Phys Rev Lett ; 132(6): 065102, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38394591

RESUMEN

On December 5, 2022, an indirect drive fusion implosion on the National Ignition Facility (NIF) achieved a target gain G_{target} of 1.5. This is the first laboratory demonstration of exceeding "scientific breakeven" (or G_{target}>1) where 2.05 MJ of 351 nm laser light produced 3.1 MJ of total fusion yield, a result which significantly exceeds the Lawson criterion for fusion ignition as reported in a previous NIF implosion [H. Abu-Shawareb et al. (Indirect Drive ICF Collaboration), Phys. Rev. Lett. 129, 075001 (2022)PRLTAO0031-900710.1103/PhysRevLett.129.075001]. This achievement is the culmination of more than five decades of research and gives proof that laboratory fusion, based on fundamental physics principles, is possible. This Letter reports on the target, laser, design, and experimental advancements that led to this result.

2.
Phys Rev Lett ; 129(7): 075001, 2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-36018710

RESUMEN

For more than half a century, researchers around the world have been engaged in attempts to achieve fusion ignition as a proof of principle of various fusion concepts. Following the Lawson criterion, an ignited plasma is one where the fusion heating power is high enough to overcome all the physical processes that cool the fusion plasma, creating a positive thermodynamic feedback loop with rapidly increasing temperature. In inertially confined fusion, ignition is a state where the fusion plasma can begin "burn propagation" into surrounding cold fuel, enabling the possibility of high energy gain. While "scientific breakeven" (i.e., unity target gain) has not yet been achieved (here target gain is 0.72, 1.37 MJ of fusion for 1.92 MJ of laser energy), this Letter reports the first controlled fusion experiment, using laser indirect drive, on the National Ignition Facility to produce capsule gain (here 5.8) and reach ignition by nine different formulations of the Lawson criterion.

3.
Osteoarthritis Cartilage ; 29(5): 687-696, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33610822

RESUMEN

OBJECTIVE: To address the need for early knee osteoarthritis (OA) markers by testing if longitudinal cartilage thickness changes are associated with specific biomechanical and biological measures acquired at a baseline test in asymptomatic aging subjects. DESIGN: Thirty-eight asymptomatic subjects over age 45 years were studied at baseline and at an average of 7-9 year follow-up. Gait mechanics and knee MRI were measured at baseline and MRI was obtained at follow-up to assess cartilage thickness changes. A subset of the subjects (n = 12) also had serum cartilage oligomeric matrix protein measured at baseline in response to a mechanical stimulus (30-min walk) (mCOMP). Baseline measures, including the knee extension (KEM), flexion (KFM), adduction (KAM) moments and mCOMP, were tested for associations with cartilage thickness changes in specific regions of the knee. RESULTS: Cartilage change in the full medial femoral condyle (p = 0.005) and external medial femoral region (p = 0.041) was negatively associated with larger early stance peak KEM. Similarly, cartilage change in the full medial femoral region (p = 0.009) and medial femoral external region (p = 0.043) was negatively associated with larger first peak KAM, while cartilage change in the anterior medial tibia was positively associated with larger first peak KAM (p = 0.003). Cartilage change in the anterior medial tibia was also significantly associated (p = 0.011) with mCOMP levels 5.5-h post-activity (percentage of pre-activity levels). CONCLUSIONS: Interactions found between gait, mechanically-stimulated serum biomarkers, and cartilage thickness in an at-risk aging asymptomatic population suggest the opportunity for early detection of OA with new approaches that bridge across disciplines and scales.


Asunto(s)
Proteína de la Matriz Oligomérica del Cartílago/sangre , Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Envejecimiento/fisiología , Enfermedades Asintomáticas , Biomarcadores/sangre , Fenómenos Biomecánicos/fisiología , Cartílago Articular/fisiopatología , Diagnóstico Precoz , Femenino , Estudios de Seguimiento , Análisis de la Marcha , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/fisiopatología
4.
Osteoarthritis Cartilage ; 25(6): 899-906, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28064033

RESUMEN

OBJECTIVE: To test if sagittal plane gait mechanics parameters and serum inflammation levels differ between healthy asymptomatic subjects and asymptomatic subjects with magnetic resonance imaging (MRI) evidence of cartilage loss. DESIGN: Gait mechanics and resting serum tumor necrosis factor-α (TNFα) concentrations were measured for two groups of asymptomatic subjects recruited for a previous study: Pre-Osteoarthritis (OA) subjects had MRI evidence of partial- or full-thickness knee cartilage loss in at least one compartment (n = 52 (30 female), 1.7 ± 0.1 m, 85.3 ± 18.9 kg, 44 ± 11 years); Control subjects had no MRI features of cartilage loss, osteophytes, bone marrow lesions, nor meniscal pathology in either knee (n = 26 (13 female), 1.7 ± 0.1 m, 74.6 ± 14.9 kg, 34 ± 10 years). Discrete measures of sagittal plane gait kinematics and kinetics were compared between subject groups and adjusted for age and body mass index (BMI) using analysis of covariance (ANCOVA). Serum TNFα concentrations were compared between groups using bootstrap t-test. RESULTS: The Pre-OA group had less extended knees (P = 0.021) and decreased maximum external knee extension moment (P = 0.0062) in terminal stance during gait, as well as increased resting serum TNFα concentration (P = 0.040) as compared to Control subjects. There were no group differences in heel strike flexion angle (P = 0.14), in maximum knee flexion moment (P = 0.91), nor in first peak knee adduction moment (KAM) (post-hoc analysis, P = 0.39). CONCLUSIONS: The finding that asymptomatic subjects with cartilage loss had gait and inflammatory characteristics similar to those previously reported in symptomatic OA patients supports the idea that there are specific mechanical and biological factors that precede the onset of knee pain in the pathogenesis of OA.


Asunto(s)
Enfermedades Asintomáticas , Cartílago Articular/diagnóstico por imagen , Citocinas/inmunología , Marcha/fisiología , Osteoartritis de la Rodilla/inmunología , Factor de Necrosis Tumoral alfa/inmunología , Adulto , Fenómenos Biomecánicos , Estudios de Casos y Controles , Femenino , Humanos , Inflamación , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/fisiopatología , Osteofito/diagnóstico por imagen , Osteofito/inmunología , Adulto Joven
5.
Osteoarthritis Cartilage ; 20(11): 1309-15, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22868052

RESUMEN

OBJECTIVE: To evaluate the hypothesis that a mechanical stimulus (30-min walk) will produce a change in serum concentrations of cartilage oligomeric matrix protein (COMP) that is associated with cartilage thickness changes on magnetic resonance imaging (MRI). METHODS: Serum COMP concentrations were measured by enzyme-linked immunosorbent assay in 17 patients (11 females, age: 59.0±9.2 years) with medial compartment knee osteoarthritis (OA) at study entry immediately before, immediately after, 3.5 h, and 5.5 h after a 30-min walking activity. Cartilage thickness changes in the medial femur and medial tibia were determined from MR images taken at study entry and at 5-year follow-up. Relationships between changes in cartilage thickness and COMP levels, with post-activity concentrations expressed as a percentage of pre-activity levels, were assessed by the calculation of Pearson correlation coefficients and by multiple linear regression analysis, with adjustments for age, sex, and body mass index (BMI). RESULTS: Changes in COMP levels 3.5 h and 5.5 h post-activity were correlated with changes in cartilage thickness in the medial femur and tibia at the 5-year follow-up. The results were strengthened after analyses were adjusted for age, sex, and BMI. Neither baseline pre-activity COMP levels nor changes in COMP levels immediately post-activity were correlated with cartilage thickness changes. CONCLUSIONS: The results of this study support the hypothesis that a change in COMP concentration induced by a mechanical stimulus is associated with cartilage thinning at 5 years. Mechanically-induced changes in mechano-sensitive biomarkers should be further explored in the context of stimulus-response models to improve the ability to assess OA progression.


Asunto(s)
Cartílago Articular/patología , Proteínas de la Matriz Extracelular/sangre , Glicoproteínas/sangre , Mecanotransducción Celular/fisiología , Osteoartritis de la Rodilla/patología , Caminata/fisiología , Fenómenos Biomecánicos , Índice de Masa Corporal , Proteína de la Matriz Oligomérica del Cartílago , Cartílago Articular/metabolismo , Progresión de la Enfermedad , Ejercicio Físico/fisiología , Femenino , Fémur/patología , Historia del Siglo XVII , Humanos , Masculino , Proteínas Matrilinas , Persona de Mediana Edad , Osteoartritis de la Rodilla/sangre , Estrés Mecánico , Tibia/patología
6.
Rev Sci Instrum ; 79(1): 013903, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18248046

RESUMEN

Veloce is a medium-voltage, high-current, compact pulsed power generator developed for isentropic and shock compression experiments. Because of its increased availability and ease of operation, Veloce is well suited for studying isentropic compression experiments (ICE) in much greater detail than previously allowed with larger pulsed power machines such as the Z accelerator. Since the compact pulsed power technology used for dynamic material experiments has not been previously used, it is necessary to examine several key issues to ensure that accurate results are obtained. In the present experiments, issues such as panel and sample preparation, uniformity of loading, and edge effects were extensively examined. In addition, magnetohydrodynamic simulations using the ALEGRA code were performed to interpret the experimental results and to design improved sample/panel configurations. Examples of recent ICE studies on aluminum are presented.

7.
Phys Rev Lett ; 87(22): 225501, 2001 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-11736405

RESUMEN

Using intense magnetic pressure, a method was developed to launch flyer plates to velocities in excess of 20 km/s. This technique was used to perform plate-impact, shock wave experiments on cryogenic liquid deuterium ( L-D(2)) to examine its high-pressure equation of state. Using an impedance matching method, Hugoniot measurements were obtained in the pressure range of 30-70 GPa. The results of these experiments disagree with previously reported Hugoniot measurements of L-D(2) in the pressure range above approximately 40 GPa, but are in good agreement with first principles, ab initio models for hydrogen and its isotopes.

8.
Phys Rev Lett ; 90(3): 035505, 2003 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-12570505

RESUMEN

A novel approach was developed to probe density compression of liquid deuterium (L-D2) along the principal Hugoniot. Relative transit times of shock waves reverberating within the sample are shown to be sensitive to the compression due to the first shock. This technique has proven to be more sensitive than the conventional method of inferring density from the shock and mass velocity, at least in this high-pressure regime. Results in the range of 22-75 GPa indicate an approximately fourfold density compression, and provide data to differentiate between proposed theories for hydrogen and its isotopes.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda