1.
Ann Surg ; 272(3): e257-e262, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32541232

RESUMEN

OBJECTIVE: The aim of the study was to provide a rapid synthesis of available data to identify the risk posed by utilizing surgical energy devices intraoperatively due to the generation of surgical smoke, an aerosol. Secondarily it aims to summarize methods to minimize potential risk to operating room staff. SUMMARY BACKGROUND DATA: Continuing operative practice during the coronavirus disease-19 (COVID-19) pandemic places the health of operating theatre staff at potential risk. SARS-CoV2 is transmitted through inhaled droplets and aerosol particles, thus posing an inhalation threat even at considerable distance. Surgical energy devices generate an aerosol of biological particular matter during use. The risk to healthcare staff through use of surgical energy devices is unknown. METHODS: This review was conducted utilizing a rapid review methodology to enable efficient generation and dissemination of information useful for concurrent clinical practice. RESULTS: There are conflicting stances on the use of energy devices and laparoscopy by different surgical governing bodies and societies. There is no definitive evidence that aerosol generated by energy devices may carry active SARS-CoV2 virus. However, investigations of other viruses have demonstrated aerosolization through energy devise use. Measures to reduce potential transmission include appropriate personal protective equipment, evacuation and filtration of surgical plume, limiting energy device use if appropriate, and adjusting endoscopic and laparoscopic practice (low CO2 pressures, evacuation through ultrafiltration systems). CONCLUSIONS: The risk of transmission of SARS-CoV2 through aerosolized surgical smoke associated with energy device use is not fully understood, however transmission is biologically plausible. Caution and appropriate measures to reduce risk to healthcare staff should be implemented when considering intraoperative use of energy devices.


Asunto(s)
COVID-19/prevención & control , COVID-19/transmisión , Diatermia/instrumentación , Electrocoagulación/instrumentación , Control de Infecciones/organización & administración , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , COVID-19/epidemiología , Humanos
3.
Int J Surg ; 82: 149-155, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32846224

RESUMEN

BACKGROUND: Eye tracking technology may provide the basis of a novel, objective technical skill assessment in surgery. Past research has showed differences in the gaze patterns between expert and novice surgeons. The aim of this study was to investigate the relationship between gaze behaviors and technical skill during laparoscopic cholecystectomy as determined by objective assessment scores. METHODS: Gaze behaviors of surgeons performing laparoscopic cholecystectomies were mapped using wearable eye tracking apparatus. Two impartial surgeons retrospectively analyzed video footage of the procedure to perform Objective Structured Assessment of Technical Skill (OSATS) assessments. Primary endpoints were correlation between gaze behaviours (dwell time (%) and fixation frequency (count/s)) and OSATS scores. Dwell time was defined as the percentage of time spent fixating on particular visual areas of interest (AOI). Pearson's correlation coefficient was used to estimate the relationship between primary endpoints and AOIs. Statistical significance was set at p < 0.05. RESULTS: 13 procedures were analyzed. Throughout all operative segments, a negative correlation was present between operating theatre dwell time and OSATS scores (p < 0.05). During dissection of Calot's triangle, there was a strong positive correlation between laparoscopic screen dwell time and OSATS scoring [r = 0.655, p < 0.05]. Scrub nurse dwell time during dissection of Calot's triangle showed a strong negative correlation with OSATS scoring [r = -0.619, p < 0.05]. During dissection of gallbladder fossa, operating theatre fixation frequency negatively correlated against OSATS scores [r = -0.566, p < 0.05]. CONCLUSION: The results suggest a greater focus on significant visual stimuli alongside a lack of attention to non-essential stimuli during critical stages of the operative period is associated with greater technical skill. This aids the validation of eye tracking as an adjunct high-stakes technical skill assessment.


Asunto(s)
Colecistectomía Laparoscópica/normas , Competencia Clínica , Movimientos Oculares , Cirujanos/psicología , Femenino , Humanos , Masculino , Estudios Prospectivos , Estudios Retrospectivos
4.
Interact Cardiovasc Thorac Surg ; 19(4): 716-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24997185

RESUMEN

Cardiac tamponade is defined as compression of the heart due to accumulation of fluid in the pericardial sac, leading to raised pericardial pressures with haemodynamic compromise. We describe the case of a 76-year old female patient who underwent a routine off-pump coronary artery bypass graft operation and within 48 h developed classic signs of cardiac tamponade. The perioperative echocardiogram and operative findings at re-exploration revealed no clots or fluid collection. A giant hiatus hernia was found to be responsible for the tamponade through extrinsic compression. After insertion of a nasogastric tube and decompression of the stomach, there was a rapid improvement of the clinical picture. The remaining postoperative course was uneventful and the patient was discharged 5 days later, with referral to the general surgeon for further management. We conclude that, in cases of tamponade post-cardiac surgery, extrapericardial pathologies should be considered.


Asunto(s)
Taponamiento Cardíaco/etiología , Puente de Arteria Coronaria Off-Pump/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Hernia Hiatal/complicaciones , Hernia Hiatal/terapia , Anciano , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/fisiopatología , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Descompresión/métodos , Ecocardiografía Transesofágica , Femenino , Hemodinámica , Hernia Hiatal/diagnóstico , Hernia Hiatal/fisiopatología , Humanos , Intubación Gastrointestinal , Valor Predictivo de las Pruebas , Factores de Riesgo , Succión , Resultado del Tratamiento