Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Ter Arkh ; 75(5): 9-12, 2003.
Artículo en Ruso | MEDLINE | ID: mdl-12847890

RESUMEN

AIM: To study effectiveness and tolerance of monoclonal antibodies to tumor necrosis factor (the drug remicade) in patients with rheumatoid arthritis (RA). MATERIAL AND METHODS: Remicade treatment results are considered for 25 RA patients receiving methotrexate the activity of which was inadequate for these patients. Remicade was infused intravenously in a dose 200 mg 4 times for 22 weeks. RESULTS: Remicade produced positive clinical and laboratory effects as early as the first infusion. The response was observed during 22 weeks of the treatment in 17 of 25 patients. Remicade tolerance was good. One patient failed the treatment because of development of collapse. CONCLUSION: Pilot results of remicade trial point to its high therapeutic potential and perspectives in rheumatology.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Antirreumáticos/uso terapéutico , Artritis Reumatoide/tratamiento farmacológico , Adulto , Anticuerpos Monoclonales/administración & dosificación , Antirreumáticos/administración & dosificación , Artritis Reumatoide/diagnóstico , Interpretación Estadística de Datos , Femenino , Humanos , Infliximab , Infusiones Intravenosas , Masculino , Metotrexato/uso terapéutico , Persona de Mediana Edad , Proyectos Piloto , Factores de Tiempo
2.
Electrophoresis ; 14(5-6): 509-14, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8354236

RESUMEN

This paper compares high performance capillary electrophoresis (HPCE) and conventional slab electrophoresis in mapping of four closely related plasmids with three different restriction enzymes. The plasmids express full length and truncated forms of a growth factor receptor oncogene product and were digested with HpaII, HaeIII and RsaI. The resulting oligonucleotide fragments were under 2000 base pairs in length, a size well suited to separation by HPCE with linear polyacrylamide as a sieving matrix. Plasmid mapping is an essential tool in biotechnology both for the design of an expression system and for monitoring the stability of the expression system during fermentation. HPCE can yield much higher resolution of oligonucleotides than attainable in conventional agarose gel electrophoretic procedures for plasmid mapping. In the examples described here, the HpaII digests provided the surest identification of individual plasmids in the HPCE analysis and could discriminate among all four plasmids. In conventional slab electrophoresis, however, the RsaI digests provided the best discrimination, although two of the plasmids in this system yielded essentially identical electrophoretic patterns. Hence the optimal restriction enzyme for plasmid mapping applications with HPCE may differ from that selected on the basis of conventional slab gel analysis, and the former technique can provide higher discrimination among related plasmids. The advantages of the HPCE format with respect to speed, low sample consumption and resolution are described.


Asunto(s)
Electroforesis en Gel de Poliacrilamida , Plásmidos/genética , Mapeo Restrictivo , Electroforesis en Gel de Agar
3.
Anal Chem ; 65(22): 3219-26, 1993 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-8291673

RESUMEN

This paper presents the principles of an instrument designed for DNA sequencing using the standard four-dye-labeled primer approach. The method is based on capillary electrophoresis with laser-induced fluorescence and an intensified diode array detector. An important goal of the instrument design has been a detection system that possesses high sensitivity and high spectral resolution. Based on an analysis of the spectral characteristics of the four standard dye-labeled primers, FAM, JOE, ROX, and TAMRA, the strategy has been to use a two-laser-two-window approach, in which a 488-nm argon ion laser illuminates one window, followed by a 543-nm helium-neon laser illuminating the second window. The two-window approach has no moving parts and permits continuous illumination. Spectral resolution is provided by a grating spectrograph and a cooled intensified diode array. The estimated limit of detection for the standard four dye-labeled primers was found to be in the sample concentration range of 1 x 10(-12) M. To achieve these low levels, complete free-radical polymerization of polyacrylamide has been found to be necessary in order to reduce background noise. In addition, reduction in background noise was accomplished by continual purging of the anodic reservoir in order to prevent electrolysis products from entering the capillary. Separation of DNA sequencing reaction products is demonstrated on a 9% T linear polyacrylamide column.


Asunto(s)
ADN/química , Electroforesis/métodos , Análisis de Secuencia de ADN/instrumentación , Secuencia de Bases , Rayos Láser , Datos de Secuencia Molecular , Polímeros , Análisis de Secuencia de ADN/métodos
4.
Nucleic Acids Res ; 22(3): 364-9, 1994 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-8127674

RESUMEN

Using a zone of constant temperature and denaturant concentration in capillary electrophoresis, we have devised a simple, rapid, and reproducible system for separating mutant from wild type DNA sequences with high resolution. Important to the success of this method, which we call Constant Denaturant Capillary Electrophoresis (CDCE), has been the use of linear polyacrylamide at viscosity levels that permit facile replacement of the matrix after each run. For a typical 100 bp fragment, point mutation-containing heteroduplexes are separated from wild type homoduplexes in less than 30 minutes. Using laser-induced fluorescence to detect fluorescent-tagged DNA, the system has an absolute limit of detection of 3 x 10(4) molecules with a linear dynamic range of six orders of magnitude. The relative limit of detection at present is 3 x 10(-4), i.e. 10(5) mutant sequences are recognized among 3 x 10(8) wild type sequences. The new approach should be applicable to the identification of low frequency mutations, to mutational spectrometry and to genetic screening of pooled samples for detection of rare variants.


Asunto(s)
Análisis Mutacional de ADN/métodos , Electroforesis en Gel de Poliacrilamida/instrumentación , Secuencia de Bases , Cartilla de ADN/química , Humanos , Datos de Secuencia Molecular , Desnaturalización de Ácido Nucleico
5.
Anal Chem ; 65(20): 2851-8, 1993 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-8250265

RESUMEN

Replaceable linear polyacrylamide (LPA) has been utilized as a sieving matrix for DNA sequencing by capillary electrophoresis (CE). Difficulties associated with cross-linked polyacrylamide gel stability have been overcome for the routine application of CE to DNA sequencing. A simple laser-induced fluorescence (LIF) detection system based on a single laser and two photomultipliers (PMT) has been adopted for this work. Sequencing information for four bases has been obtained from two fluorescent dyes and two peak height ratios, detected in two optical channels. FAM- and JOE-labeled M13 (-21) primers have been chosen because both dyes are efficiently excited with a low-power argon ion laser, can be optically separated, and exhibit minimal dye-based shifts in DNA fragment mobilities. Addition of denaturants to the electrophoresis running buffer (1 x TBE, 3.5 M urea, 30% formamide) and column operation at 32 degrees C permitted the resolution of difficult compressed sites in the sequence of phage M13mp18. Careful examination of the polymerization reaction of LPA has led to methodology that has proven to be reproducible for obtaining DNA sequencing information of M13mp18 phage for 350 nucleotides in close to 30 min.


Asunto(s)
Electroforesis en Gel de Poliacrilamida/métodos , Análisis de Secuencia de ADN , Espectrometría de Fluorescencia/métodos , Resinas Acrílicas/química , Secuencia de Bases , ADN , Rayos Láser , Datos de Secuencia Molecular , Programas Informáticos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda