Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Int Orthop ; 46(10): 2229-2235, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35729351

RESUMEN

INTRODUCTION: The continuing high demand for revision total hip arthroplasty (RTHA) requires not only additional economic costs, but also the search for new, effective methods to manage the reconstruction of acetabular bone loss. This study focuses on the assessment of the clinical and radiographic outcomes after RTHA using custom-made augments (CMA) in the short-term follow-up period. MATERIALS AND METHODS: We retrospectively analyzed the results of using CMAs in 19 patients (20 hips). The average follow-up period was 41.3 months. All surgery was performed on defect types III and IV as per the Gross and Saleh classification. RESULTS: There was a statistically significant difference when comparing the Oxford Hip Score before RTHA of 15.0 (Std. deviation-5.9) and after RTHA of 36.3 (Std. deviation-6.3) (p = 0.01). All implants were radiologically stable. CMA has demonstrated a good ability to restore position of hip centre of rotation (HCOR). In the postoperative period, two patients (2 hips) had dislocations. Only one of two patients underwent re-revision due to dislocation. CONCLUSION: Treatment of uncontained loss of bone stock in RTHA using CMA shows promising clinical and radiographic results at short-term follow-up period; however, dislocation rate is 10% in this study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Enfermedades de Transmisión Sexual , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Humanos , Reoperación/métodos , Estudios Retrospectivos
2.
Khirurgiia (Mosk) ; (5): 52-56, 2019.
Artículo en Ruso | MEDLINE | ID: mdl-31169819

RESUMEN

AIM: Experimental analysis of the strength properties of integration of muscle tissue, tendons and ligaments, bone tissue into titanium highly porous materials prepared by using of additive technologies. MATERIAL AND METHODS: The study included 9 mature rabbits of the Chinchilla breed. Both posterior paws and latissimus dorsi muscles (36 specimens) were used. Titanium models (Ti-6-Al-4-V, 'Rematitan', Germany) were made by additive technologies with preliminary prototyping, the prototypes had a highly porous mesh structure. RESULTS: It was developed experimental model of functional bone defect involving points of attachment of the muscle and ligaments. Strength of attachment of muscles to highly porous implants was 145 H vs. 31 H for standard models. Tensile strength for fixation to bone tissue was 84 H vs. 152 H in the main group. CONCLUSION: It was found integration of soft tissues and bones into highly porous titanium implants prepared with additive technologies. Fixation strength significantly exceeds that for standard models.


Asunto(s)
Huesos/cirugía , Sistema Musculoesquelético/fisiopatología , Oseointegración/fisiología , Prótesis e Implantes , Cicatrización de Heridas/fisiología , Animales , Materiales Biocompatibles , Huesos/lesiones , Huesos/fisiopatología , Ligamentos/fisiopatología , Ligamentos/cirugía , Modelos Animales , Músculo Esquelético/fisiopatología , Músculo Esquelético/cirugía , Porosidad , Diseño de Prótesis , Implantación de Prótesis , Conejos , Recuperación de la Función , Reoperación , Mallas Quirúrgicas , Tendones/fisiopatología , Tendones/cirugía , Titanio
3.
Vestn Khir Im I I Grek ; 175(4): 46-52, 2016.
Artículo en Inglés, Ruso | MEDLINE | ID: mdl-30457264

RESUMEN

The article presents the authors' experience. Medical visualization is applied in orthopedics on all stages such as diagnostics, treatment planning and control of the results. Modern approaches in instrumental diagnostics and specialized application-dependent software allowed a new qualitative level of orthopedics and medical care in different areas of medicine. Modern technologies gave a lot of opportunities to doctors in order to improve diagnostics at higher level, make an individual planning of operations and built individual implants, when it wasn't possible to use standard constructions.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Articulación de la Cadera , Imagenología Tridimensional/métodos , Complicaciones Posoperatorias/prevención & control , Tomografía Computarizada por Rayos X/métodos , Adulto , Artrometría Articular/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Luxación de la Cadera/diagnóstico , Luxación de la Cadera/cirugía , Articulación de la Cadera/irrigación sanguínea , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Planificación de Atención al Paciente , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda