Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 201
Filtrar
1.
J Esthet Restor Dent ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38923112

RESUMEN

OBJECTIVE: The present clinical report describes a long-term temporary restorative approach using injectable composite to reshape a canine into a central incisor, within the context of an ongoing orthodontic treatment. This treatment protocol describes a fully-digital workflow, incorporating digital designed and 3D printed diagnostic wax up, reduction guides and resin-injection index. CLINICAL CONSIDERATIONS: Effective planning is important when aiming to deliver a comprehensive and multidisciplinary workflow, and digital tools serve as invaluable aids. CONCLUSION: The use of a fully digital workflow in a comprehensive dental treatment resulted in a predictable and successful outcome for a restoration of a canine that was transformed into a central incisor. CLINICAL SIGNIFICANCE: This approach highlights the efficacy of digital technology in achieving precise and successful dental restorations, emphasizing its significance in modern dental practice.

2.
J Esthet Restor Dent ; 36(4): 620-631, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37950565

RESUMEN

OBJECTIVE: Obtaining strong resin bonds to computer-aided design and computer-aided manufacturing (CAD-CAM) resin-based composites with dispersed fillers (CCRBCs) poses a challenge. Therefore, this study aimed to assess the effect of three universal adhesives and a two-component silane coupling agent on the shear bond strength to three (CCRBCs). MATERIALS AND METHODS: Eight hundred and sixty-four specimens of Brilliant Crios, Lava Ultimate, and Tetric CAD were polished or grit blasted, bonded with Adhese Universal DC, One Coat 7 Universal (OC7), and Scotchbond Universal Plus Adhesive (SBU) with or without a silane primer. Shear bond strength was measured after 24 h and 10,000 thermocycles. Linear regressions were performed (α = 0.05). RESULTS: After thermocycling, bond strengths were similar for the universal adhesives on polished Brilliant Crios and Lava Ultimate (p ≥ 0.408). Grit blasted Tetric CAD showed no significant differences (p ≥ 0.096). The silane primer had minimal impact on grit blasted Tetric CAD (p ≥ 0.384). The silane primer increased the bond strength of OC7 to Brilliant Crios (p = 0.001) but decreased the adhesion of SBU to Brilliant Crios and Lava Ultimate (p ≤ 0.018). CONCLUSIONS: Bond strength of universal adhesives varied with CCRBC type. The two-component silane coupling agent showed mixed effects on adhesive performance. CLINICAL SIGNIFICANCE: Selecting universal adhesives from the same CCRBC product line does not always guarantee superior bond strength. The efficacy of silane coupling agents differs based on the bonding substrate.


Asunto(s)
Recubrimiento Dental Adhesivo , Silanos , Silanos/química , Cementos Dentales , Propiedades de Superficie , Materiales Dentales , Cementos de Resina/química , Diseño Asistido por Computadora , Ensayo de Materiales
3.
J Esthet Restor Dent ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39165048

RESUMEN

OBJECTIVE: To analyze and compare the impact of acidic media on the surface characteristics of highly filled flowable resin-based composites. MATERIALS AND METHODS: Two hundred fifty-six specimens were divided into four groups: GUF (G-aenial Universal Flo), GUI (G-aenial Universal Injectable), TEF (Tetric EvoFlow), and FSF (Filtek Supreme Flowable Restorative). Surface characteristics were analyzed before (T0) and after specimens immersion in different media, such as gastric juice (GJ), fizzy drink (FD), citric juice (CJ), or artificial saliva (AS), for 9 h (T1) and 18 h (T2). The analyses included surface roughness (SR) measurements, where average roughness (Ra) was obtained, scanning electron microscopy (SEM) analysis, and surface hardness (SH) evaluation, with Vickers numbers (HV) reported. The differences in values among groups/subgroups within the same stage were assessed using two-way ANOVA and Tukey's post hoc test, whereas repeated measures ANOVA with Bonferroni post hoc test was performed to compare the changes in values through the stages. Data were presented as mean ± standard deviation (SD). RESULTS: At T0, GUI and GUF revealed lower Ra values (p < 0.05), more evenness in SEM micrographs, and higher HV values (p < 0.05) than FSF and TEF. At T1 and T2, specimens of all groups/subgroups demonstrated an increase in Ra and a decrease in HV compared with T0 (p < 0.05), as well as the changes in surface morphology on SEM micrographs. The lowest Ra and highest HV values were observed in GUI group, in contrast to FSF group, and in specimens immersed in GJ. CONCLUSIONS: GUI revealed lower SR and higher SH compared to GUF and FSF both before and after exposure to acidic media. The presence of acidic media, especially GJ, significantly increases SR and decreases SH of tested materials. CLINICAL SIGNIFICANCE: Information on the changes in the surface characteristics of highly filled resin-based composites after exposure to acidic media may be essential for the longevity of restorations like composite veneers fabricated from these materials.

4.
J Esthet Restor Dent ; 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39093128

RESUMEN

OBJECTIVE: This article puts forward consensus recommendations from PROSEC North America regarding single indirect restorations made from ceramic and nonmetallic biomaterials in posterior teeth. OVERVIEW: The consensus process involved a multidisciplinary panel and three consensus workshops. A systematic literature review was conducted across five databases to gather evidence. The recommendations, informed by findings from systematic reviews and formulated based on a two-phase e-Delphi survey, emphasize a comprehensive treatment strategy that includes noninvasive measures alongside restorative interventions for managing dental caries and tooth wear. The recommendations advocate for selecting between direct and indirect restorations on a case-by-case basis, favoring inlays and onlays over crowns to align with minimally invasive dentistry principles. The recommendations highlight the critical role of selecting restorative biomaterials based on clinical performance, esthetic properties, and adherence to manufacturer guidelines. They emphasize the importance of precision in restorative procedures, including tooth preparation, impression taking, contamination control, and luting. Regular follow-up and maintenance tailored to individual patient needs are crucial for the longevity of ceramic and nonmetallic restorations. CONCLUSIONS: These PROSEC recommendations provide a framework for dental practitioners to deliver high-quality restorative care, advocating for personalized treatment planning and minimally invasive approaches to optimize oral health outcomes. CLINICAL SIGNIFICANCE: The PROSEC North America recommendations highlight the importance of minimally invasive techniques in posterior tooth restorations using ceramic and non-metallic biomaterials. These principles prioritize tooth structure conservation and personalized treatment planning, essential for enhancing clinical outcomes and long-term oral health.

5.
J Prosthet Dent ; 131(3): 475.e1-475.e7, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38182453

RESUMEN

STATEMENT OF PROBLEM: Intraoral digital scan techniques have been widely used and sufficient evidence supports this technique in partially edentulous patients. However, the evidence supporting the use of intraoral scanners (IOSs) for edentulous patients is limited. PURPOSE: The purpose of this in vitro study was to measure and compare the accuracy of complete arch conventional pick-up implant impressions with open and closed trays, complete arch digital implant scans with IOSs, and 3-dimensional (3D) printed casts from complete arch digital implant scans. MATERIAL AND METHODS: Six implants were placed in a mandibular model. Scannable pick-up impression copings were inserted in the implants, scanned with a reference scanner, and exported in standard tessellation language (STL) format (Group Control). Splinted open-tray pick-up impressions (Group OT, n=5) and closed-tray pick-up impressions (Group CT, n=5) were made, and stone casts were fabricated. Digital scans (Group DS, n=5) were made with an IOS, and the STL files were exported to fabricate 3D printed casts (Group STL, n=5). Scannable pick-up impression copings were inserted in the dental implant analogs in Groups OT, CT, and STL and scanned with the reference scanner. Using a 3D inspection software program, the recording techniques were compared with the control. Root mean square (RMS) values were calculated from the control, and superimposed digitized casts from different recording techniques. Analysis of variance was used to determine differences in RMS values, and theTukey post hoc test was used to determine difference between different groups. RESULTS: Group CT had the lowest mean dimensional difference when superimposed with Group Control, followed by Groups DS, OT, and STL. Significant differences were found in RMS values between Control and digitized casts fabricated with different techniques (P<.05). The post hoc Tukey test revealed that Group DS (P<.05) was significantly different from the other groups, while no significant difference was found among Groups CT, OT, and STL (P>.05). CONCLUSIONS: Based on the findings of the present study, 3D printed casts from digital scans have the same accuracy as stone casts from conventional impressions in complete arch implant cases. Intraoral scans had the highest accuracy. Complete arch pick-up impression techniques using dual-functioning scannable pick-up impression copings are as accurate as splinted complete arch pick-up impressions.


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Habilidades de Afrontamiento , Mandíbula , Proyectos de Investigación
6.
J Prosthodont ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39073711

RESUMEN

PURPOSE: To determine the effect of restorations with long contact areas for the management of interdental papilla deficiencies, in smile attractiveness among laypersons and dentists. MATERIAL AND METHODS: A full-portrait image was used to create a set of digitally modified images, simulating the management of various levels of interdental papilla loss. In a total of 48 modified images, single as well as multiple loss of interdental papilla among the anterior teeth, treated with a single or multiple restorations were simulated for unilateral and bilateral situations. Through a digital monitor 160 laypeople and dentists were asked to assess the attractiveness of each displayed image utilizing a visual-analog-scale. Multiple Wilcoxon-signed-rank tests followed by Mann-Whitney U tests were performed considering a significance level of 0.05. RESULTS: The management of an open gingival embrasure due to interdental papilla loss, by simulating the restoration of both central incisors led to a significantly higher mean smile attractiveness compared to the restoration of a single central incisor. Among the investigated regions, the management of open gingival embrasure in the area of central incisors using a restorative approach was perceived as the least esthetic (p < 0.05). CONCLUSIONS: Despite the restorative management of interdental papilla loss, with the establishment of longer contact areas for the reduction of open gingival embrasures, as the level of the interdental papilla loss is increased, facial esthetics are compromised. When a longer contact area is accomplished through a single restoration, asymmetry among the teeth can be induced, especially in the region of the central incisors.

7.
Clin Oral Investig ; 27(6): 2691-2703, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36622446

RESUMEN

OBJECTIVES: To assess the impact of the age of resin-based composite (RBC) restorations used for deep margin elevation (DME) on the marginal quality and fracture resistance of inlays. MATERIALS AND METHODS: Permanent human molars with direct RBC restorations, involving the mesial, occlusal, and distal surface (MOD), were allocated to four groups (each n = 12). Half of the teeth underwent thermomechanical loading including 240,000 occlusal load cycles and 534 thermal cycles (TML, 5 °C/55 °C; 49 N, 1.7 Hz). With RBC left in one proximal box as DME, all teeth received MOD inlays, made from lithium disilicate (LDS) or a polymer-infiltrated ceramic network material (PICN). The restored teeth underwent TML including 1.2 million occlusal cyclic loadings and 2673 thermal cycles. The marginal quality was assessed at baseline and after both runs of TML. Load-to-fracture tests were performed. The statistical analysis comprised multiple linear regressions (α = 0.05). RESULTS: Simulated aging of RBC restorations had no significant effect on the marginal quality at the interface between the RBC and the tooth and the RBC and the inlay (p ≥ 0.247). Across time points, higher percentages of non-continuous margin were observed between the inlay and the tooth than between the tooth and the RBC (p ≤ 0.039). The age of the DME did not significantly affect the fracture resistance (p ≥ 0.052). CONCLUSIONS: Artificial aging of RBC restorations used for DME had no detrimental effect on the marginal quality and fracture resistance of LDS and PICN inlays. CLINICAL RELEVANCE: This laboratory study suggests that-in select cases-intact, direct RBC restorations not placed immediately before the delivery of an indirect restoration may be used for DME.


Asunto(s)
Resinas Compuestas , Incrustaciones , Humanos , Anciano , Materiales Dentales , Porcelana Dental , Cerámica , Diseño Asistido por Computadora , Ensayo de Materiales , Análisis del Estrés Dental
8.
J Esthet Restor Dent ; 35(1): 148-157, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36628558

RESUMEN

OBJECTIVE: This article describes an updated step-by-step protocol for transmucosal abutment selection and treatment sequencing after immediate implant placement in the esthetic zone. CLINICAL CONSIDERATIONS: Current surgical and prosthetic concepts strive to preserve hard and soft-tissues to provide optimal esthetics at the implant-abutment interface. Consequently, restoring implants in the esthetic zone with transmucosal abutments presents a great challenge and must take into consideration implant depth, angulation, and bucco-lingual position as well as transmucosal height and space for an optimized emergence profile of the restoration and the dimensions of the anterior tooth to be restored. The proper selection of the type, shape, and dimensions of implant components and connections, determined by the product portfolio offered by the implant manufacturer, play a critical role in the ability to adequately address these challenges. This article provides an update on surgical and prosthetic workflows for single implant restorations in the esthetic zone. CONCLUSIONS: Following esthetic, mechanical, and biologic principles, the long-term success of implant-supported restorations in the esthetic zone is directly correlated to proper execution and sequencing of surgical and prosthetic treatment steps, especially after immediate implant placement. These steps must be critically assessed based on the current scientific evidence to achieve the desired clinical outcomes on a predictable and consistent basis. CLINICAL SIGNIFICANCE: Selection of surgical and prosthetic treatment protocols to achieve ideal esthetic outcomes and emergence profiles in implant dentistry is often a great challenge, not only determined by technical and clinical skills of the provider but also by the type and dimensions of implant components and connections offered by the manufacturer. Following certain decision-making principles and workflows are key for clinical success with implant-supported restorations after immediate implant placement the esthetic zone.


Asunto(s)
Pilares Dentales , Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Estética Dental , Carga Inmediata del Implante Dental/métodos
9.
J Esthet Restor Dent ; 35(4): 657-676, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36789480

RESUMEN

OBJECTIVES: To conduct a scoping review on color stability of bulk-fill compared to conventional resin-based composites exposed to colored beverages. MATERIALS AND METHODS: In vitro studies, investigating bulk-fill resin-based composites color stability submitted to artificial staining by colored beverages were included. Studies investigating color change induced by smoke and whitening treatments as well as papers not written in English language were excluded. A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) was performed on four databases (Embase, Medline, Scopus, Web of Science) for articles published until October 01st 2022. The study selection was then performed by two authors who screened the abstracts independently and followed the JBI approach. RESULTS: Of 717 screened abstracts, 59 were selected for full-text analysis. Finally, 19 studies were included in this review. They investigated 19 different bulk-fill composites and different artificial-staining-by-liquids-protocols including coffee, red wine, tea, coke, and others. Seven papers reported higher color change in the investigated bulk fill materials than in conventional resin-based composites, while nine studies reported the opposite. SonicFill showed the highest color stability for most of the papers. CONCLUSIONS: The available evidence suggests that bulk-fill materials show variability in color stability. This behavior can be attributed to the heterogeneity of composition and staining procedures in the selected studies. CLINICAL SIGNIFICANCE: Clinicians should keep in mind that bulk-fill materials may change color when exposed to colorant drinks or food.


Asunto(s)
Café , Materiales Dentales , Ensayo de Materiales , Coloración y Etiquetado
10.
J Esthet Restor Dent ; 35(1): 26-47, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36602272

RESUMEN

OBJECTIVE: Deep margin elevation (DME) is a treatment approach to relocate the cervical margin of teeth with subgingival defects to a supragingival position with a direct restoration to facilitate rubber dam isolation, impression taking, and bonding of indirect restorations. This article provides an overview of the current scientific evidence on DME and future directions for research. OVERVIEW: The review included 38 studies on DME, most conducted in vitro. These studies indicate that DME has no detrimental effect on the fracture resistance of restored teeth. Evidence on the impact of DME on marginal quality is conflicting, but most in vitro studies observed no negative effect. Clinical studies, most comprising small patient cohorts, demonstrated favorable restorative outcomes and suggest that DME restorations made with scrupulous care are compatible with periodontal health. Bleeding on probing may occur more frequently at sites with DME, though evidence on this is not unequivocal. CONCLUSIONS: Current evidence, based largely on laboratory studies and limited clinical data, supports DME as a viable approach to restore teeth with localized subgingival defects. However, further clinical studies with long-term follow-ups are required to provide corroborative evidence. CLINICAL SIGNIFICANCE: Current evidence suggests that DME is a viable approach to restore teeth with localized subgingival defects as a possible alternative to surgical crown lengthening. Proper working field isolation, meticulous care in the bonding and buildup procedure, and biofilm removal through patient-performed oral hygiene and professional maintenance care are crucial. As scant clinical trial-based evidence is available today, further research is needed to evaluate the long-term performance of DME restorations and their impact on periodontal health.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Adaptación Marginal Dental , Coronas
11.
J Esthet Restor Dent ; 35(7): 1098-1102, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37017291

RESUMEN

OBJECTIVE: This article provides an overview of the implications of ChatGPT and other large language models (LLMs) for dental medicine. OVERVIEW: ChatGPT, a LLM trained on massive amounts of textual data, is adept at fulfilling various language-related tasks. Despite its impressive capabilities, ChatGPT has serious limitations, such as occasionally giving incorrect answers, producing nonsensical content, and presenting misinformation as fact. Dental practitioners, assistants, and hygienists are not likely to be significantly impacted by LLMs. However, LLMs could affect the work of administrative personnel and the provision of dental telemedicine. LLMs offer potential for clinical decision support, text summarization, efficient writing, and multilingual communication. As more people seek health information from LLMs, it is crucial to safeguard against inaccurate, outdated, and biased responses to health-related queries. LLMs pose challenges for patient data confidentiality and cybersecurity that must be tackled. In dental education, LLMs present fewer challenges than in other academic fields. LLMs can enhance academic writing fluency, but acceptable usage boundaries in science need to be established. CONCLUSIONS: While LLMs such as ChatGPT may have various useful applications in dental medicine, they come with risks of malicious use and serious limitations, including the potential for misinformation. CLINICAL SIGNIFICANCE: Along with the potential benefits of using LLMs as an additional tool in dental medicine, it is crucial to carefully consider the limitations and potential risks inherent in such artificial intelligence technologies.


Asunto(s)
Inteligencia Artificial , Odontólogos , Humanos , Rol Profesional , Lenguaje , Fenbendazol
12.
J Esthet Restor Dent ; 35(7): 1050-1057, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37026815

RESUMEN

OBJECTIVE: This clinical case describes a completely digital workflow using current digital technologies for a full-mouth adhesive rehabilitation with ultra-translucent multilayer zirconia restorations. CLINICAL CONSIDERATIONS: A healthy 60-year-old man with abfractions on all upper and lower molars and severe tooth wear underwent a full-mouth rehabilitation with laminate veneers and partial adhesive restorations. A proper zirconia bonding protocol was realized to provide a durable bond between the ultra-translucent zirconia and the resin cement. Furthermore, the implementation of a digital workflow enables the clinician to have an effective communication during treatment planning and simplify the clinical and laboratory procedures, providing the patient with long-term esthetic treatment and functional results. CONCLUSION: The implementation of a completely digital workflow and the use of ultra-translucent multilayer zirconia for indirect adhesive restorations can be an alternative with simplified and predictable procedures for patients with dental wear and teeth discolorations. CLINICAL SIGNIFICANCE: The digital workflow described is intended to facilitate the planning and execution of a full-mouth adhesive rehabilitation and demonstrates to clinicians a reliable zirconia bonding concept for minimally invasive anterior and posterior restorations.


Asunto(s)
Cementos Dentales , Rehabilitación Bucal , Masculino , Humanos , Persona de Mediana Edad , Flujo de Trabajo , Circonio
13.
J Esthet Restor Dent ; 35(1): 48-55, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36325593

RESUMEN

OBJECTIVE: To evaluate the effect of rubber dam isolation on shear bond strength of two different adhesive systems to enamel. MATERIALS AND METHODS: The mesial, distal, lingual, and vestibular enamel surfaces of thirty human third molars were prepared (total n = 120). A custom splint was made to fit a volunteer's maxilla, holding the specimens in place in the oral cavity. Four composite resin cylinders were bonded to each tooth with one of two bonding agents (OptiBond FL and Prime&Bond active) with or without rubber dam isolation. Shear bond strength was tested in a universal testing machine and failure modes were assessed. Significance level for statistical analyses was set at 5%. RESULTS: All pairwise comparisons revealed statistical differences (p < 0.05). The highest mean shear bond strength values were obtained in rubber dam experimental groups, regardless of the adhesive system. Group OptiBond FL with rubber dam presented the highest mean bond strength values. Fracture modes for specimens bonded without rubber dam isolation were adhesive and cohesive within enamel, while rubber dam experimental groups revealed only cohesive fractures. CONCLUSIONS: Absolute isolation with rubber dam increases bond strength to enamel, independent of the adhesive system. The three-step total-etch system OptiBond FL provided significantly higher bond strength values than Prime&Bond active under both experimental conditions. CLINICAL SIGNIFICANCE: Rubber dam isolation has a significant effect on bond strengths to enamel, independent of the adhesive system. Its application is, therefore, advised whenever adhesive procedures are performed. A filled three-step etch-and-rinse adhesive performed superiorly, with or without rubber dam isolation, when bonding to enamel compared to an isopropanol-based universal adhesive.


Asunto(s)
Recubrimiento Dental Adhesivo , Humanos , Dique de Goma , Cementos de Resina/química , Resinas Compuestas/química , Esmalte Dental , Ensayo de Materiales , Recubrimientos Dentinarios/química
14.
J Oral Implantol ; 49(5): 465-472, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349661

RESUMEN

Vertical and horizontal reconstruction of the alveolar ridge, especially in the anterior maxilla, is considered a clinical challenge for dentists. There is still a lack of a standard technique to address the hurdles in 3-dimensional bone regeneration in the anterior maxilla. In this clinical feasibility study, we aimed to modify Khoury's technique by combining the conventional guided bone regeneration standards with the principles of this technique. The autogenous bone blocks were harvested from the retromolar area and grafted into the deficient anterior maxillae by mini-screws, and the gap was filled with xenogenic bone particles. The grafted site was covered with multilayered resorbable collagen membranes. Cone-beam computerized tomographic scans were obtained at the 6-month follow-ups, and the changes in ridge width and height were measured. Five subjects with multiple missing teeth at the anterior maxilla were included. The radiographic outcomes of the 6-month follow-ups revealed 1.2 mm of height and 3.5 mm of width gain. Between the 4- and 6-month visits, approximately 2 mm resorption in height and 0.3 mm in width occurred. No complications occurred. The proposed modification for Khoury's technique can serve as a feasible method in the 3-dimensional reconstruction of the anterior maxilla without additional autogenous bone particles.


Asunto(s)
Aumento de la Cresta Alveolar , Humanos , Estudios de Factibilidad , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Estudios Prospectivos , Proceso Alveolar
15.
Int J Comput Dent ; 26(1): 75-88, 2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36825568

RESUMEN

Digital dentistry has contributed to the evolution and simplification of dental implantology over the last decade. The incorporation of intraoral scanners, CBCT, 3D implant-planning software, and CAD/CAM systems makes prosthetically driven implantology a straightforward process. Such digital resources for treatment planning and execution, following evidence-based concepts, have the ability to improve the long-term esthetics and function of implant-supported restorations as well the long-term survival of dental implants. Dental implants are frequently considered as the first treatment option for replacing failing or missing teeth. However, their use in the esthetic zone remains a challenge for many clinicians. The present article provides clinical guidelines for ideal implant positioning employing computer-guided surgery and chairside CAD/CAM-fabricated provisional and definitive restorations with titanium (Ti)-bases for successful prosthetic outcomes, optimizing gingival architecture, and decreasing overall treatment duration. (Int J Comput Dent 2023;26(1):75-0; doi: 10.3290/j.ijcd.b3818287).


Asunto(s)
Implantes Dentales , Humanos , Titanio , Estética Dental , Diseño Asistido por Computadora , Implantación Dental Endoósea , Prótesis Dental de Soporte Implantado
16.
J Prosthodont ; 32(8): 689-696, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36883776

RESUMEN

PURPOSE: This prospective clinical study evaluated and compared the marginal and internal fit of crowns fabricated with an analog workflow and three different computer-aided design and computer-aided manufacturing (CAD-CAM) systems. MATERIALS AND METHODS: Twenty-five participants in need of a single complete-coverage molar or premolar crown were recruited in the study. Twenty-two completed the study, and three participants dropped out. Teeth were prepared according to a standardized protocol by one operator. For each participant, one final impression was made with polyether material (PP) and three intraoral scanners: CEREC Omnicam (C), Planmeca Planscan (PM), and True Definition (TR). For the PP group, crowns were fabricated with a pressable lithium disilicate ceramic, whereas for the other three groups (C, PM, and TR), crowns were designed and milled with dedicated CAD-CAM systems and materials. Marginal (vertical and horizontal) and internal discrepancies between the crowns and tooth preparation were measured at various locations with digital superimposition software. Data was analyzed for normality with Kolmogorov-Smirnov and Shapiro-Wilk tests and then compared with one-way ANOVA and Kruskal-Wallis tests. RESULTS: Mean vertical marginal gap values were 92.18 ± 141.41 µm (PP), 150.12 ± 138.06 µm (C), 129.07 ± 109.96 µm (PM), and 135.09 ± 112.03 µm (TR). PP group had statistically significantly smaller vertical marginal discrepancy (p = 0.001) than all other groups, whereas no significant difference was detected among the three CAD-CAM systems (C, PM, and TR). Horizontal marginal discrepancies were 104.93 ± 111.96 µm (PP), 89.49 ± 119.66 µm (C), 113.36 ± 128.49 µm (PM), and 136.39 ± 142.52 µm (TR). A significant difference was detected only between C and TR (p < 0.0001). Values for the internal fit were 128.40 ± 49.31µm (PP), 190.70 ± 69.79µm (C), 146.30 ± 57.70 µm (PM), and 168.20 ± 86.67 µm (TR). The PP group had a statistically significant smaller internal discrepancy than C (p < 0.0001) and TR groups (p = 0.001), whereas no significant difference was found compared to the PM group. CONCLUSION: Posterior crowns fabricated with CAD-CAM systems showed vertical margin discrepancy greater than 120 µm. Only crowns fabricated with the conventional methodology had vertical margins below 100 µm. Horizontal marginal discrepancy was different among all groups, and only CEREC CAD-CAM was below 100 µm. Internal discrepancy was less for crowns fabricated with an analog workflow.


Asunto(s)
Coronas , Porcelana Dental , Humanos , Flujo de Trabajo , Estudios Prospectivos , Cerámica , Diseño Asistido por Computadora , Diente Molar , Diseño de Prótesis Dental/métodos , Adaptación Marginal Dental
17.
J Esthet Restor Dent ; 34(1): 117-135, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35072329

RESUMEN

OBJECTIVES: Several systematic literature reviews have assessed the scientific evidence on resin bonding protocols to conventional 3 mol% ytrria-stabilized zirconia (3Y-TZP) ceramics. It has been widely discussed, however, that the differing composition and physical properties of new high-translucent zirconia generations (4Y-TZP and 5Y-TZP) may require alternative bonding materials and procedures. This paper reviewed in vitro studies on the success and durability of bonding protocols to high-translucent zirconia. MATERIAL AND METHODS: A systematic search of PubMed and Cochrane Library for in vitro studies on bonding to new zirconia generations published until November 2020 was conducted and complemented by a manual search. Studies selected for review fulfilled the applied inclusion and exclusion criteria. The quality of the included studies was assessed with the Cochrane risk-of-bias tool for randomized trials. RESULTS: Of 629 screened articles, 18 were included in this review. They investigated different surface pretreatment methods, primers, resin cements, aging procedures, and bond strength test protocols. The limited number of the identified studies and the heterogeneity of the extracted data did not allow to conduct a meta-analysis. CONCLUSIONS: The available evidence suggests that resin bonding protocols successfully applied to conventional zirconia are also the most successful for high-translucent zirconia. Airborne particle abrasion and special phosphate monomer-containing primers or composite resin cements provide long-term durable resin bonds. CLINICAL SIGNIFICANCE: Durable bonds can be established between high-translucent zirconia and resin cements. The bonding materials and procedures applied do not compromise their physical properties.


Asunto(s)
Recubrimiento Dental Adhesivo , Cerámica/química , Análisis del Estrés Dental , Ensayo de Materiales , Cementos de Resina/química , Propiedades de Superficie , Circonio/química
18.
J Esthet Restor Dent ; 34(1): 252-258, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35076981

RESUMEN

OBJECTIVE: This clinical report describes and illustrates step-by-step protocols for interdisciplinary esthetic treatment with current digital and microscopic tools. CLINICAL CONSIDERATIONS: Digital dentistry is no longer limited to impression making and restoration fabrication but starts already in the diagnostic and treatment planning phase. In particular, digital smile design tools have significantly improved clinical and laboratory workflows, allowing for natural and facially driven smiles, based on the patient's specific needs and preferences. Digital technologies also facilitate high precision and accuracy in the laboratory, which are interconnected with the quality of the clinical care. Precision and minimally invasive dentistry require visual magnification aids through high-power loupes or, even better, surgical microscopes. For optimal clinical success, however, these tools must be integrated into efficient workflows and made part of a comprehensive clinical and laboratory concept. CONCLUSIONS: Digital and high-magnification tools in clinics and dental laboratories facilitate highly esthetic and precise outcomes when integrated into a comprehensive treatment concept. CLINICAL SIGNIFICANCE: While a plethora of new tools and technologies is available for the dental laboratory and clinical practice, they can be daunting. Clear step-by-step workflows and protocols must be followed to apply them in a most efficient and effective manner for optimal outcomes.


Asunto(s)
Estética Dental , Diente , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Humanos , Sonrisa , Flujo de Trabajo
19.
J Esthet Restor Dent ; 34(8): 1213-1220, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35934807

RESUMEN

OBJECTIVE: To evaluate and compare the clinical performance of two nano-hybrid giomer restorative composite materials after 5 years. MATERIALS AND METHODS: Forty-four pairs of restorations (total n = 88) of a flowable giomer (Beautifil Flow Plus F00; Shofu Inc., Kyoto, Japan) and a conventional nano-hybrid giomer restorative material (Beautifil II; Shofu Inc.) were placed in Class I cavities after the application of a dentin adhesive (FL-Bond II; Shofu Inc.) and a flowable liner (Beautifil Flow Plus F03; Shofu Inc). After 5 years, 32 pairs of restorations were assessed using the modified United States Public Health Service criteria. Both tested materials were compared using Fisher's exact test and each tested clinical criterion for each material was analyzed separately with respect to different follow-up periods using Friedman's test (a = 0.05). RESULTS: None of the restorations showed complete retention loss, post-operative sensitivity, secondary caries or color change. There were no significant changes to any of the clinical criteria for each material during the 5-year evaluation period (p > 0.05) and no significant differences between the two materials in all clinical parameters after 5 years (p > 0.05). CONCLUSIONS: Five-year clinical performance of both two nano-hybrid giomer restorative materials was comparably acceptable and not significantly different for any of the parameters evaluated. CLINICAL SIGNIFICANCE: Nano-hybrid giomer-based materials are clinically acceptable for the restoration of occlusal cavities as they demonstrate excellent performance after 5 years.


Asunto(s)
Caries Dental , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Fluoruros , Bisfenol A Glicidil Metacrilato/química , Resinas Compuestas/química , Recubrimiento de la Cavidad Dental , Caries Dental/terapia , Estudios de Seguimiento
20.
J Esthet Restor Dent ; 34(5): 763-768, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35138026

RESUMEN

OBJECTIVE: The aim of this case report is to present the CAD/Press technique; a workflow that combines digital design, milled, or 3D printed burnout molds, and a new pressable ceramic material for the treatment of extensive noncarious lesions with minimal invasive indirect ceramic restorations. CLINICAL CONSIDERATIONS: Clinical decisions from material selection, preparation design, manufacturing techniques to adhesive protocols will be discussed, as they are important factors for achieving long-term clinical success while preserving healthy tooth structure. CLINICAL SIGNIFICANCE: The presented workflow aims to ease clinical decisions when restoring extensive cases with indirect restorations and show clinicians a workflow combining several techniques.


Asunto(s)
Porcelana Dental , Diseño de Prótesis Dental , Cerámica/química , Diseño Asistido por Computadora , Coronas , Porcelana Dental/química , Diseño de Prótesis Dental/métodos , Humanos , Ensayo de Materiales , Circonio
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda