Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Heart Lung Circ ; 26(3): 235-239, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27475261

RESUMEN

BACKGROUND: The New Zealand Cardiac Implanted Device Registry (Device) has recently been developed under the auspices of the New Zealand Branch of the Cardiac Society of Australia and New Zealand. This study describes the initial Device registry cohort of patients receiving a new pacemaker, their indications for pacing and their perioperative complications. METHODS: The Device Registry was used to audit patients receiving a first pacemaker between 1st January 2014 and 1st June 2015. RESULTS: We examined 1611 patients undergoing first pacemaker implantation. Patients were predominantly male (59%), and had a median age of 70 years. The most common symptom for pacemaker implantation was syncope (39%), followed by dizziness (30%) and dyspnoea (12%). The most common aetiology for a pacemaker was a conduction tissue disorder (35%), followed by sinus node dysfunction (22%). Atrioventricular (AV) block was the most common ECG abnormality, present in 44%. Dual chamber pacemakers were most common (62%), followed by single chamber ventricular pacemakers (34%), and cardiac resynchronisation therapy - pacemakers (CRT-P) (2%). Complications within 24hours of the implant procedure were reported in 64 patients (3.9%), none of which were fatal. The most common complication was the need for reoperation to manipulate a lead, occurring in 23 patients (1.4%). CONCLUSION: This is the first description of data entered into the Device registry. Patients receiving a pacemaker were younger than in European registries, and there was a low use of CRT-P devices compared to international rates. Complications rates were low and compare favourably to available international data.


Asunto(s)
Terapia de Resincronización Cardíaca , Electrocardiografía , Marcapaso Artificial , Complicaciones Posoperatorias , Sistema de Registros , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Nueva Zelanda/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/terapia , Factores de Tiempo
2.
Heart Lung Circ ; 24(10): e162-3, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26256565

RESUMEN

INTRODUCTION: The cardiac effects of many illegal substances (cocaine, methadone) have previously been well described [1,2]. However the association between synthetic cannabis and cardiac arrest is less well documented. Here we describe an out-of-hospital cardiac arrest in a previously healthy 16-year-old female associated with the use of inhaled synthetic cannabis. METHODS: An electronic systematic search of online databases PubMed and Embase was performed using keywords, "synthetic cannabis death" and "cardiac arrest". RESULTS: In this case study a previously healthy 16-year-old had a cardiac arrest after synthetic cannabis use. Despite extensive investigations no other cause for her arrest was found. To the best of our knowledge there has been one previous case report of cardiac arrest following synthetic cannabis use in a 56-year-old man [3]. CONCLUSIONS: This case report augments the relationship between synthetic cannabis and cardiac arrest in the medical community. More awareness surrounding the risk of synthetic cannabinoids is warranted.


Asunto(s)
Cannabinoides/efectos adversos , Drogas de Diseño/efectos adversos , Paro Cardíaco Extrahospitalario/inducido químicamente , Trastornos Relacionados con Sustancias/complicaciones , Adolescente , Femenino , Humanos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda