Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Clin Exp Allergy ; 49(4): 526-536, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30672059

RESUMEN

BACKGROUND: Peach is a common elicitor of food allergic reactions. Peach-induced immediate reactions may occur as benign pollen-food syndromes, usually due to birch pollen-related PR-10 cross-reactivity in temperate climates, and as potentially severe primary food allergies, predominantly related to nsLTP Pru p 3 in Mediterranean regions. The newly described peach allergen Pru p 7 has gained recent attention as a potential peach allergy severity marker. Sensitization to Pru p 7 and its allergenic homologues of the gibberellin-regulated protein family occurs in areas with high Cupressaceae tree pollen exposure. OBJECTIVE: We sought to investigate the distribution, clinical characteristics and molecular associations of Pru p 7 sensitization among subjects with suspected peach allergy in different regions of France. METHODS: Subjects with suspected peach allergy (n = 316) were included. Diagnostic work-up was performed according to current guidelines, including open food challenge when required. IgE antibody measurements and competition experiments were performed using the ImmunoCAP assay platform. RESULTS: Sensitization to Pru p 7 was present in 171 (54%) of all subjects in the study and in 123 of 198 (62%) diagnosed as peach allergic, more than half of whom were sensitized to no other peach allergen. Frequency and magnitude of Pru p 7 sensitization were associated with the presence of peach allergy, the clinical severity of peach-induced allergic reactions and the level of cypress pollen exposure. Cypress pollen extract completely outcompeted IgE binding to Pru p 7. Pru p 7 was extremely potent in basophil activation tests. CONCLUSION AND CLINICAL RELEVANCE: A subtype of Cupressaceae pollinosis, characterized by Pru p 7 sensitization, can be an underlying cause of severe peach allergy.


Asunto(s)
Antígenos de Plantas/inmunología , Reacciones Cruzadas/inmunología , Cupressus/inmunología , Hipersensibilidad a los Alimentos/diagnóstico , Hipersensibilidad a los Alimentos/inmunología , Polen/inmunología , Prunus persica/efectos adversos , Adolescente , Adulto , Anciano , Alérgenos/inmunología , Basófilos/inmunología , Basófilos/metabolismo , Niño , Preescolar , Susceptibilidad a Enfermedades , Femenino , Hipersensibilidad a los Alimentos/epidemiología , Humanos , Inmunización , Inmunoglobulina E/inmunología , Lactante , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Adulto Joven
2.
Contact Dermatitis ; 79(2): 76-80, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29635853

RESUMEN

BACKGROUND: The frequency of allergic contact dermatitis caused by (meth)acrylates is increasing worldwide, and isobornyl acrylate (IBOA) has been identified as a culprit sensitizer in FreeStyle Libre, a medical device used by diabetic patients. OBJECTIVES: To report on 4 patients sensitized to IBOA contained in OmniPod, a new, tubeless insulin pump, and to describe the clinical and chemical analytical work-up. METHOD: Four patients with eczematous skin eruptions after using OmniPod, including 2 with previous adverse skin reactions to FreeStyle Libre, were patch tested with a baseline series and additional (meth)acrylates, including IBOA in several concentrations and/or vehicles. Gas chromatography-mass spectrometry (GC-MS) was used to identify the presence of IBOA in OmniPod. RESULTS: All patients were shown to be sensitized to IBOA. GC-MS identified IBOA in OmniPod, with the highest concentrations being found in the unit itself and not in the adhesive patch. CONCLUSIONS: The OmniPod tubeless insulin pump is another source of IBOA, and its use may lead to primary sensitization to this acrylate, or may provoke elicitation of allergic contact dermatitis in previously sensitized patients. Our cases highlight the need to obtain satisfactory cooperation from pharmaceutical companies involved in the manufacture of these widely used medical devices.


Asunto(s)
Acrilatos/efectos adversos , Adhesivos/efectos adversos , Canfanos/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Sistemas de Infusión de Insulina/efectos adversos , Adolescente , Adulto , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Humanos , Persona de Mediana Edad , Pruebas del Parche
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda