Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Eur Spine J ; 30(6): 1574-1584, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33635376

RESUMEN

BACKGROUND: C1-C2 injury represents 25-40% of cervical injuries and predominantly occurs in the geriatric population. METHODS: A prospective multicentre study was conducted under the aegis of the french spine surgery society (SFCR) investigating the impact of age, comorbidities, lesion type, and treatment option on mortality, complications, and fusion rates. RESULTS: A total of 417 patients were recruited from 11 participating centres. The mean ± SD age was 66.6 ± 22 years, and there were 228 men (55%); 5.4% presented a neurological deficit at initial presentation. The most frequent traumatic lesion was C2 fracture (n = 308). Overall mortality was 8.4%; it was 2.3% among those aged ≤ 60 years, 5.0% 61-80 years, and 16.0% > 80 years (p < 0.001). Regarding complications, 17.8% of patients ≤ 70 years of age presented with ≥ 1 complication versus 32.3% > 70 years (p = 0.0009). The type of fracture did not condition the onset of complications and/or mortality (p > 0.05). The presence of a comorbidity was associated with a risk factor for both death (p = 0.0001) and general complication (p = 0.008). Age and comorbidities were found to be independently associated with death (p < 0.005). The frequency of pseudoarthrosis ranged from 0 to 12.5% up to 70 years of age and then constantly and progressively increased to reach 58.6% after 90 years of age. CONCLUSIONS: C1-C2 injury represents a serious concern, possibly life-threatening, especially in the elderly. We found a major impact of age and comorbidities on mortality, complications, and pseudarthrosis; injury pattern or treatment option seem to have a minimal effect.


Asunto(s)
Seudoartrosis , Fracturas de la Columna Vertebral , Fusión Vertebral , Adulto , Anciano , Anciano de 80 o más Años , Vértebras Cervicales/lesiones , Femenino , Curación de Fractura , Humanos , Masculino , Persona de Mediana Edad , Cuello , Estudios Prospectivos , Fracturas de la Columna Vertebral/cirugía , Resultado del Tratamiento
2.
Clin Exp Immunol ; 176(1): 49-57, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24298980

RESUMEN

Chronic bone infection is associated with bone resorption. From animal studies, CD3/CD28-activated T cells are known to enhance osteoclastogenesis and bone resorption. Because CD28 is expressed constitutively on T cells and its expression is down-regulated by chronic exposure to the inflammatory environment, we characterized co-stimulatory molecule expression on T cells from chronically infected patients. We used cytofluorometric techniques to phenotypically characterize T cells, its co-stimulatory molecules and perforin secretion from infected and non-infected human bones. Chronic bone infection was defined as infection lasting for more than a month. We show a higher T cell activation [human leucocyte antigen D-related (HLA-DR⁺)] in infected compared to non-infected bones: median being 16 versus 7%, P = 0·009 for CD4 T cells, and 33 versus 15%, P = 0·038 for CD8 T cells, respectively. However, T cell proliferation (Ki67⁺) was lower for CD8 T cells in infected bones: 26 versus 34%, P = 0·045. In contrast, we detected no difference in apoptosis and regulatory T cells. In infected bone, we found higher CD28-negative CD4⁺ T cells compared to non-infected bone: 20 versus 8%, respectively (P = 0·005); this T cell subset had higher CD11b expression and perforin secretion. Chronically infected human bones are characterized by an increase of CD28-negative CD4⁺ T cells, indicating long-term activated cells with cytotoxic ability. Therefore, this alteration of co-stimulatory molecules may modify interactions with osteoclasts and impact bone resorption.


Asunto(s)
Infecciones Bacterianas/inmunología , Linfocitos T CD4-Positivos/inmunología , Proliferación Celular , Osteomielitis/inmunología , Linfocitos T/inmunología , Adulto , Anciano , Infecciones Bacterianas/sangre , Antígenos CD28/inmunología , Antígenos CD28/metabolismo , Linfocitos T CD4-Positivos/metabolismo , Linfocitos T CD8-positivos/inmunología , Linfocitos T CD8-positivos/metabolismo , Enfermedad Crónica , Femenino , Citometría de Flujo , Antígenos HLA-DR/inmunología , Antígenos HLA-DR/metabolismo , Humanos , Activación de Linfocitos/inmunología , Recuento de Linfocitos , Masculino , Persona de Mediana Edad , Osteomielitis/sangre , Perforina/inmunología , Perforina/metabolismo , Linfocitos T/metabolismo , Factores de Tiempo , Adulto Joven
3.
Morphologie ; 97(316): 19-28, 2013 Mar.
Artículo en Francés | MEDLINE | ID: mdl-23375579

RESUMEN

AIM OF THE STUDY: Our knowledge on anatomy of lumbar spine is based on few cadaver's study with old and few subjects. CT-scan is very precise for lumbar facet's morphology. We have analysed 400 subjects. The aim of this study is to measure different distances, angles and circles to better understand the mechanical function of the lumbar facets. PATIENTS AND METHODS: We have analysed 720 CT-scan. We had 217 men and 183 women with 59 years of mean age. We used native slices of 1.25 mm thick from L1 to S1. We created transversal plan and we put different mark point. We took their coordinates and we have calculated different distances, angles and mechanical circles. We have compared different axis of rotation of the facets. RESULTS: From L1 to S1, the facets goes near to the posterior wall and far from themselves. Moreover, the posterior angle between both facets increase down to the sacrum. The radius of the left side circle and the right one are very closed in 50% of the cases but the three radius are close only in 10% of cases. CONCLUSION: This study based on 400 subjects shows that there is not a unique axis of rotation for both lumbar posterior facets. We have had only 50% of symmetry between both sides whatever the level studied.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Articulación Cigapofisaria/anatomía & histología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Antropometría , Artrografía , Fenómenos Biomecánicos , Bases de Datos Factuales , Femenino , Marcadores Fiduciales , Humanos , Vértebras Lumbares/fisiología , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Rotación , Sacro/diagnóstico por imagen , Adulto Joven , Articulación Cigapofisaria/fisiología
4.
J Neuroradiol ; 39(1): 44-50, 2012 Mar.
Artículo en Francés | MEDLINE | ID: mdl-21821290

RESUMEN

Discography test associated with the scanner (discoscanner) is an exam that has been a renewed interest in recent few years. Thanks to the emergence of new interventions such as disc prosthesis, the procedures require confirmation of the disc level to deal with and the origin of discogenic symptoms. The aim of this paper is to describe the techniques, challenges and tips as well as the interpretation of functional and morphological examination.


Asunto(s)
Disco Intervertebral/diagnóstico por imagen , Dolor de la Región Lumbar/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Medios de Contraste , Humanos , Yopamidol/análogos & derivados , Imagen por Resonancia Magnética , Dimensión del Dolor
5.
Hand Surg Rehabil ; 40(1): 69-74, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33137466

RESUMEN

Digital ischemia due to arterial defects need urgent surgical management. The traditional treatment consists of vascular reconstruction using a reversed autologous venous graft as a bypass. Very few studies have described the use of arterial grafts for digital artery reconstruction. This cadaver study characterized the forearm perforator arteries to assess the potential feasibility of using them as donor grafts for digital artery reconstruction. Eleven forearms and twenty hands were dissected from freshly injected cadavers. All clinically significant perforators (>0.5 mm) derived from radial or ulnar arteries and digital arteries were evaluated. The digital palmar arteries were measured at three points: metacarpophalangeal (MCP) joint, proximal interphalangeal (PIP) joint, and distal interphalangeal (PIP) joint. In the 11 forearms analyzed, 5.5 ± 1.3 perforators from radial or ulnar arteries with a diameter of at least 0.5 mm were found per dissection. The mean diameters were 0.9 ± 0.18 mm proximally and 0.8 ± 0.15 mm distally; the mean length was 35.6 ± 11.35 mm. The mean diameters for the dominant and non-dominant arteries were 1.5 and 1.3 mm at the MCP, 1.3 and 1.0 mm at the PIP, 0.8 and 0.7 mm at the DIP, respectively. The forearms are good donor sites as they have large-diameter arteries of suitable length for arterial grafting. These new arterial grafts may be suitable for vascular reconstruction of digital arteries starting from the PIP joint.


Asunto(s)
Mano , Arteria Cubital , Cadáver , Antebrazo , Humanos , Arteria Radial/cirugía , Arteria Cubital/cirugía
6.
Hand Surg Rehabil ; 40(3): 241-249, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33757862

RESUMEN

The forearm is an interesting donor site for non-vascularized nerve grafts, especially hand surgeons. Very few studies have described the use of the lateral and medial antebrachial cutaneous nerves (LABCN and MABCN, respectively) as vascularized nerve grafts (VNGs). The aim of this anatomical study was to analyze the characteristics and vascularization of these nerves to describe new potential donor sites for VNGs. Twelve forearms were dissected from fresh cadavers injected with red latex. The number of terminal branches, lengths, and proximal and distal diameters of both the LABCN and MABCN were studied. An anatomical description of the cutaneous perforator arteries from the radial and ulnar arteries that vascularized the nerve was also recorded: number of perforators, length, type of perforator (septo- or musculocutaneous), and location within the forearm (proximal, middle, and distal third). In over 80% of the specimens, the cutaneous perforator arteries from the radial and ulnar artery vascularized the LABCN and the MABCN, respectively. These arteries, found mostly in the proximal third of the forearm, had diameters >0.5mm. Most of them came from the radial and ulnar arteries (for LABCN and MABCN vascularization, respectively). In over 75% of the specimens, the nutrient arteries of both nerves also vascularized the superficial veins and the skin. We found that these nerves are vascularized by perforators arteries, which also participate in vein and skin vascularization. Altogether, this anatomical study shows that reconstructive surgeons could use new VNGs based on the perforator artery of the forearm.


Asunto(s)
Antebrazo , Arteria Cubital , Cadáver , Humanos , Arteria Radial , Venas
7.
Chir Main ; 28(3): 158-67, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19356963

RESUMEN

BACKGROUND: The "terrible triad" of the elbow is the combination of an elbow dislocation, radial head and a coronoid process fracture. Because of a combined sagittal, frontal and transverse instability, these injuries are notoriously difficult to treat. We report our results with a technique for reconstruction of "terrible triad" injuries with either no facture or a type I fracture of the coronoid process in addition to a non-reparable radial head fracture. The hypothesis of this study was that standard surgical treatment of this lesion using a "deep to superficial" stabilisation by a single lateral approach and radial head replacement enables early and reliable functional results. PATIENTS: From June 2004 to January 2007, 13 patients with an average age of 40 years at the date of trauma (range 18-77) underwent reconstruction of a "terrible triad" injury of the elbow with the same technique. The mean follow-up was 25 months (range 15-48). RESULTS: Eighty-four percent of the patients were very satisfied and satisfied. Average flexion was 131 degrees (110-140). Average extension was -11 degrees (-30-0). Average pronation was 72 degrees (40-80). Average supination was 70 degrees (50-80). The grip strength averaged 75% of that of the non-injured side (50-105). All elbows were stable at review. Eight complications occurred. CONCLUSION: Our results suggest that some terrible triad injuries can be successfully managed with deep to superficial stabilisation by lateral approach, consisting in three-dimensional stabilisation done by anterior capsular reinsertion with absorbable anchors, radial head replacement and lateral collateral ligament repair. This standard management provides enough stability to allow early active rehabilitation, preventing post-operative instability and stiffness. This procedure appears to be reliable and reproducible.


Asunto(s)
Lesiones de Codo , Articulación del Codo/cirugía , Luxaciones Articulares/cirugía , Fracturas del Radio/cirugía , Adolescente , Adulto , Anciano , Ligamentos Colaterales/cirugía , Femenino , Fuerza de la Mano , Humanos , Luxaciones Articulares/diagnóstico por imagen , Prótesis Articulares , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Pronación , Radiografía , Fracturas del Radio/diagnóstico por imagen , Supinación , Anclas para Sutura
8.
J Plast Reconstr Aesthet Surg ; 72(1): 131-136, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30327185

RESUMEN

BACKGROUND: Over the past decade, cosmetic injections of dermal fillers or fat have become a popular procedure in facial rejuvenation in an overconsuming society. However, complications such as arterial embolism and occlusion can occur even with experienced injectors, especially in high-risks zones namely the glabella, the nasal dorsum or the nasolabial fold. The aim of this study was to define the vascular danger zones of the infraorbital area in order to provide guidelines helping avoid them. MATERIALS AND METHODS: The infraorbital artery, its main branches and their anastomoses with neighbouring vessels were studied in 18 fresh cadavers. Mimetic injections of inked hyaluronic acid were performed in the infraorbital area in the interest of analyzing its distribution and to determine potential vascular risks towards the infraorbital artery and its branches. RESULTS: The infraorbital artery and its branches were located in common injection regions and anastomosed to the supratrochlear artery, the dorsal nasal artery and the angular artery through the nasal branch of the infraorbital artery. Two danger zones could be depicted: injections can be risky when performed too superficially in the midcheek area, and likewise risky when performed in a periosteal layer in infraorbital hollow or tear-trough correction, because of an obvious possibility of retrograde embolism. CONCLUSION: The infraorbital artery can be involved in anatomic mechanism of arterial occlusion, further blindness and stroke, among the related neighbouring arteries. Based on the findings of this study, injections to the periosteum layer in tear-trough correction and above the periosteum on the zygomatic arch is not advised.


Asunto(s)
Estética , Arteria Oftálmica/anatomía & histología , Cadáver , Técnicas Cosméticas/efectos adversos , Rellenos Dérmicos/efectos adversos , Cara , Humanos , Ácido Hialurónico/administración & dosificación , Ácido Hialurónico/farmacología , Inyecciones Intraarteriales/efectos adversos , Rejuvenecimiento , Factores de Riesgo
9.
Rev Chir Orthop Reparatrice Appar Mot ; 94(5): 456-63, 2008 Sep.
Artículo en Francés | MEDLINE | ID: mdl-18774020

RESUMEN

PURPOSE OF THE STUDY: The aim of this work was to study the technique of percutaneous osteosynthesis of lumbar and thoracolumbar spine fractures without neurological deficit and to report preliminary results. MATERIAL AND METHODS: This retrospective study included 15 patients with lumbar or thoracolumbar spine fractures who were treated between January 2004 and January 2006 by percutaneous osteosynthesis. There were seven men and eight women, mean age 36 years (range 16-58 years). The Magerl classification (AO) was A1 (n=4), A2 (n=1), A3 (n=9), B2 (n=1). Levels were T12 (n=1), L1 (n=10), L2 (n=2), L3 (n=1), L4 (n=1). A specific instrument set was used to insert a short fixation using two pedicular screws on either side of the fractured vertebra and two prebent 5.5mm rods introduced with an aiming device. The operation was performed under fluoroscopy. Ten patients wore a removable corset. The upright position was allowed if there were no other injuries. Computed-tomography scans were obtained preoperatively, postoperatively and at two years follow-up. Function was assessed with the Oswestry score. RESULTS: Mean operative time was 108 minutes (range 40-180 minutes). None of the patients with an isolated spinal injury required blood transfusion. Mean hospital stay was 12 days (range 4-28). Results were expressed for 13 patients whose operations were exclusively percutaneous. Mean follow-up was 17 months (range 6-30). The visual analog scale (VAS) was 1.6/10. The mean Oswestry score was 16. Three quarters of the patients resumed their occupational activities. None of the patients was dissatisfied. Mean vertebral kyphosis (VK) improved from 16 to 8.1 degrees , corrected regional angle (CRA) from 12 to 2.5 degrees at last follow-up. Loss of correction at last follow-up was 1.1 degrees for VK and 2.5 degrees for CRA. The rate of pedicle screw malposition was 3.8%. There were no cases of disassembly nor material failure. There were no infections. None of the implants had to be removed. DISCUSSION: Percutaneous osteosynthesis of the spine is technically feasible, but requires considerable experience. Functional and subjective results have been good. The loss of correction at last follow-up has been comparable to that observed with conventional open surgery. This technique is an intermediary method between orthopaedic treatment and conventional surgery. Exact indications must be established. CONCLUSION: Percutaneous osteosynthesis of lumbar and thoracolumbar spine fractures is an attractive therapeutic option. Our results are encouraging. Indications and limitations of this technique must be carefully identified.


Asunto(s)
Fijación Interna de Fracturas/métodos , Vértebras Lumbares/lesiones , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/lesiones , Adolescente , Adulto , Tornillos Óseos , Femenino , Fluoroscopía , Estudios de Seguimiento , Fijación Interna de Fracturas/instrumentación , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Postura , Estudios Retrospectivos , Fracturas de la Columna Vertebral/clasificación , Fracturas de la Columna Vertebral/diagnóstico por imagen , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
Orthop Traumatol Surg Res ; 101(3): 387-90, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25817905

RESUMEN

Digital imaging is a daily practice in traumatology. Such photographs should remain confidential. However, there is a need for objectivity concerning the circumstances and clinical follow-up for trauma patients. This paper describes how to conserve these photographs within the picture archiving and communication system (PACS) safely as regards identity and confidentiality. A computer converts the photographs into DICOM files. The DICOM image is associated to a reconciliation layer, validated by the physician in charge, and then included in the hospital PACS. This improves transmission from one medical team to another, both initially and after the accident if an expert medical opinion is required. The literature has demonstrated the value of photographs in modern medicine, but the technical and legal challenges are many. They enhance the computerized medical records. Identification, confidentiality and integration in the PACS are obstacles that we have now overcome.


Asunto(s)
Bases de Datos Factuales , Procesamiento de Imagen Asistido por Computador , Fotograbar , Heridas y Lesiones , Confidencialidad , Curaduría de Datos , Francia , Hospitales de Enseñanza , Humanos
11.
Orthop Traumatol Surg Res ; 99(2): 162-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23453915

RESUMEN

OBJECTIVE: To compare radiation exposure doses and clinical and radiological outcomes between percutaneous pedicular screwing (closed reduction internal fixation [CRIF]) and classical open reduction internal fixation (ORIF) in lumbar spine fracture without neurologic deficit. MATERIALS AND METHODS: Sixty patients (mean age, 42.5 years) were divided into two treatment groups: (Percutaneous) CRIF versus (traditional) ORIF. Screw position and anatomic vertebral reconstruction were checked on routine control X-ray and postoperative CT scan. Study parameters comprised: surgery time, radiation exposure time, radiation dose level for X-ray (DAP) and for CT (DLP),blood loss, length of hospital stay and postoperative pain (VAS). RESULTS: At a mean 25.5 months' follow-up,there were no significant inter-group differences on the epidemiological parameters: age, gender, fracture level, fracture type on the Magerl classification, preoperative local vertebral kyphosis angle, or fracture-to-surgery interval. Effective radiation dose was 3-fold higher in CRIF than in ORIF, but 6-fold lower than for the postoperative CT scan. Postoperative pain on VAS was significantly lower after CRIF, allowing earlier gait resumption and return to work and daily activity. There were no significant differences in length of hospital stay, patient satisfaction, screw malpositioning or postoperative or end-of-follow-up kyphosis angle. CONCLUSION: Percutaneous surgery provided clinical and radiological outcomes strictly comparable to those of open surgery, but with a higher effective radiation exposure dose, including for the medical team and especially for the surgeon. This higher exposure dose, however, is to be relativized by comparison to that of the postoperative CT scan, which involved a much higher exposure dose for the patient. LEVEL OF EVIDENCE: Level IV. Retrospective study.


Asunto(s)
Vértebras Lumbares/lesiones , Procedimientos Ortopédicos/métodos , Fracturas de la Columna Vertebral/cirugía , Adolescente , Adulto , Anciano , Femenino , Humanos , Periodo Intraoperatorio , Tiempo de Internación , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Dolor Postoperatorio/epidemiología , Satisfacción del Paciente , Dosis de Radiación , Adulto Joven
12.
Diagn Interv Imaging ; 93(1): 10-21, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22277706

RESUMEN

Disc arthroplasty is the replacement of a painful pathological intervertebral disc by a prosthesis, which, unlike spinal fixation, has the advantage of retaining vertebral mobility in the segment concerned. The success of the procedure is dictated by the indication. The radiologist must look for radiographic arguments indicating or contraindicating fitting an implant, and particularly for the presence of facet arthritis which will prompt the surgeon to choose an arthrodesis. Moreover, radiological information plays a major part in preparing for a surgical procedure, as far as access to the disc via the anterior approach is concerned and assessment by CT angiography of the risk of vascular complications. After insertion, radiological monitoring using dynamic X-ray images checks that the implant is correctly positioned and that mobility is restored. In the long term, it can detect complications related to the prosthesis and premature wear to other points of support such as adjacent discs and the facet joints.


Asunto(s)
Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/cirugía , Prótesis Articulares , Humanos , Diseño de Prótesis , Radiografía
13.
Orthop Traumatol Surg Res ; 97(6): 662-7, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21943776

RESUMEN

Repeated use of X-rays in orthopedic surgery poses the problem of irradiation of patient and caregivers. Seven common minimally invasive bone trauma surgical procedures requiring image intensifier use were investigated: percutaneous K-wire fixation of the wrist, minimally invasive fixation plating of the wrist, percutaneous intramedullary nailing of the tibia and of the femur, short and long trochanteric nail fixation of trochanteric and sub-trochanteric fracture, and percutaneous fixation of thoracolumbar fracture. The study analyzed three parameters: dose area product (DAP), radiation duration, and skin entrance dose (SED). Data were collected from 15 successive implementations of each procedure. The aim of the study was to establish a database for this kind of bone trauma surgery and a hierarchy of the X-ray doses delivered. Percutaneous spinal osteosynthesis involved the highest dose, followed in decreasing order by long trochanteric nailing, femoral nailing, short trochanteric nailing, tibial nailing, wrist K-wire fixation and frontal wrist plate osteosynthesis. One short trochanteric nail procedure delivered the same DAP as 13 wrist K-wire fixation procedures, and one spinal osteosynthesis was equivalent to 13 short trochanteric nail or 174 wrist K-wire procedures. The anatomic area X-rayed appeared to be the main radiation dose factor. A database was established, but actual patient and staff radiation levels remained unknown.


Asunto(s)
Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Procedimientos Ortopédicos/métodos , Dosis de Radiación , Fluoroscopía , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Prospectivos
14.
Orthop Traumatol Surg Res ; 97(5): 533-40, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21741890

RESUMEN

INTRODUCTION: Total disc replacement (TDR) has existed since 1984 but is not covered by the French national healthcare system (Sécurité Sociale). The present study assessed clinical outcomes, and also pre-, peri- and postoperative treatment costs. HYPOTHESIS: Surgical management of low back pain (LBP) provides medical and economic benefit. MATERIALS AND METHODS: A prospective study recruited 19 patients in the Nice University Hospital Center (France); mean age, 41 years; 15 female. Inclusion criteria were: age less than 60 years; chronic low back pain (LBP) with single-segment discopathy; work related injuries and patients not covered under the General provision of the Sécurité Sociale were excluded. VAS, Oswestry and SF36 scores and return to work capability were analyzed. The local national health insurance branch office (Caisse Primaire d'Assurance Maladie [CPAM]) provided detailed coverage data for a 39-month period around the operation. RESULTS: Revision surgery was required for one instance of vertebral fracture. Preoperative follow-up was 14 months, postoperative FU 21 months and the perioperative period 4 months. LBP and quality of life showed improvement. Seventy-nine percent of patients reported satisfaction, 59% returned to work, and 84% had leisure activity. Total CPAM payout (reimbursement) was €399,082. Daily sickness benefit and disability compensation were the main cost items. Mean TDR cost per patient was €6833. Mean reimbursements were 19% lower post- than preoperatively. Pre- and postoperative clinical results did not correlate, while pre- and postoperative reimbursement costs did, as did cost and postoperative clinical status (r=-0.72). Preoperative cost was a predictive factor for postoperative clinical result. DISCUSSION: TDR achieves favorable medicoeconomic results. LEVEL OF EVIDENCE: III: case-control study.


Asunto(s)
Reeemplazo Total de Disco/economía , Adulto , Bases de Datos Factuales , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reeemplazo Total de Disco/efectos adversos , Resultado del Tratamiento , Adulto Joven
15.
Rev Chir Orthop Reparatrice Appar Mot ; 94(8): 771-6, 2008 Dec.
Artículo en Francés | MEDLINE | ID: mdl-19070721

RESUMEN

SUMMARY: Free-hip movement is necessary for good spinal function. Limitation generally affects extension. The range of hip extension from the standing position can be considered as the hip's "extension reserve". The amplitude of this reserve must be known because any deficit requires a pathological solicitation of the vertebral column. Measurement of the extension reserve of the hip is useful for analyzing spinal disease and for preoperative planning. Physical examination can measure extension, but cannot differentiate movement produced by the hip from that originating in the spine. We have been unable to locate any radiographic method in the literature. The purpose of this study was to evaluate radiographic measurements and to propose a novel method. The study was conducted with 37 patients with spinal disease. Two radiographic methods were compared. Four lateral views, including the lumbar spine, the pelvis and the femur were obtained in each patient: neutral position, retroversion of the pelvis and extension of each hip in lunge position. The X-rays were digitalized for computer processing. The extension reserve of the hip was calculated for each radiographic method. Extension reserve was defined as the difference in the pelvis-femoral angle between the neutral position and extension. There was a positive correlation between the two methods (p<0.0006; p<0.0009). Mean extension using the pelvis retroversion method was 1.8 degrees +/-6.77; with the hip-extension method, it was hip I (side with the superior value): 15.9 degrees +/-6.57; hip II 10.0 degrees +/-7.89. The pelvis-retroversion method gave a lower measurement compared with the lunge position method (p<0.0001). For 13 of 37 subjects (35%), this method gave negative values, that is, failure of the measurement method. The method of hip extension in lunge position was superior to the pelvis-retroversion method, which gave lower measurements that were often incoherent and unable to provide specific information for each hip. The method using the lunge position for hip extension appears to be preferable. We are currently conducting a clinical trial to include extension reserve in the analysis of sagittal balance and for determining curvature corrections. We propose a mathematical formula using extension reserve for determining sagittal correction. Radiographic determination of extension reserve of the hip joint is of major importance for assessing spinal disease in addition to its contribution to the analysis of hip and pelvic disease. The methods presented here enable radiographic measurement of the extension reserve of the hip.


Asunto(s)
Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Rango del Movimiento Articular
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda