Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Mult Scler ; 30(1): 44-54, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38018502

RESUMEN

BACKGROUND: Whether the degree of inflammation (and its resolution) and neurodegeneration after treatment initiation predicts disease progression in multiple sclerosis (MS) remains unclear. OBJECTIVES: To assess the predictive value of magnetic resonance imaging (MRI)-derived brain and lesion volume (LV) changes in years 1 and 2 of treatment for disease progression. METHODS: Patients receiving early interferon beta-1a treatment in REFLEX/REFLEXION (N = 262) were included. Predictive regression models included new/enlarging LV (positive activity), disappearing/shrinking LV (negative activity), and global/central atrophy during years 1 and 2. RESULTS: Faster global atrophy and/or pseudo-atrophy and positive lesion activity in years 1 and 2 related to an increased probability and faster conversion to clinically definite multiple sclerosis (CDMS). Negative lesion activity in year 1 and slower central atrophy in year 2 were predictive of confirmed disability progression (9-Hole Peg Test). Positive lesion activity in year 2 was predictive of faster global atrophy, while positive lesion activity in years 1 and 2 was predictive of faster central atrophy. CONCLUSIONS: A higher degree of global atrophy and/or pseudo-atrophy in year 1 was predictive of CDMS. Positive lesion activity in any year was related to CDMS and neurodegeneration. Disability was related to negative lesion activity in year 1 and slower central atrophy in year 2.


Asunto(s)
Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/tratamiento farmacológico , Esclerosis Múltiple/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Interferón beta-1a , Progresión de la Enfermedad , Atrofia/patología , Imagen por Resonancia Magnética/métodos
2.
Eur J Nucl Med Mol Imaging ; 50(8): 2409-2419, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36976303

RESUMEN

PURPOSE: Tau pathology is associated with concurrent atrophy and decreased cerebral blood flow (CBF) in Alzheimer's disease (AD), but less is known about their temporal relationships. Our aim was therefore to investigate the association of concurrent and longitudinal tau PET with longitudinal changes in atrophy and relative CBF. METHODS: We included 61 individuals from the Amsterdam Dementia Cohort (mean age 65.1 ± 7.5 years, 44% female, 57% amyloid-ß positive [Aß +], 26 cognitively impaired [CI]) who underwent dynamic [18F]flortaucipir PET and structural MRI at baseline and 25 ± 5 months follow-up. In addition, we included 86 individuals (68 CI) who only underwent baseline dynamic [18F]flortaucipir PET and MRI scans to increase power in our statistical models. We obtained [18F]flortaucipir PET binding potential (BPND) and R1 values reflecting tau load and relative CBF, respectively, and computed cortical thickness from the structural MRI scans using FreeSurfer. We assessed the regional associations between i) baseline and ii) annual change in tau PET BPND in Braak I, III/IV, and V/VI regions and cortical thickness or R1 in cortical gray matter regions (spanning the whole brain) over time using linear mixed models with random intercepts adjusted for age, sex, time between baseline and follow-up assessments, and baseline BPND in case of analyses with annual change as determinant. All analyses were performed in Aß- cognitively normal (CN) individuals and Aß+ (CN and CI) individuals separately. RESULTS: In Aß+ individuals, greater baseline Braak III/IV and V/VI tau PET binding was associated with faster cortical thinning in primarily frontotemporal regions. Annual changes in tau PET were not associated with cortical thinning over time in either Aß+ or Aß- individuals. Baseline tau PET was not associated with longitudinal changes in relative CBF, but increases in Braak III/IV tau PET over time were associated with increases in parietal relative CBF over time in Aß + individuals. CONCLUSION: We showed that higher tau load was related to accelerated cortical thinning, but not to decreases in relative CBF. Moreover, tau PET load at baseline was a stronger predictor of cortical thinning than change of tau PET signal.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Proteínas tau/metabolismo , Adelgazamiento de la Corteza Cerebral , Tomografía de Emisión de Positrones , Enfermedad de Alzheimer/metabolismo , Péptidos beta-Amiloides/metabolismo , Atrofia/diagnóstico por imagen , Circulación Cerebrovascular , Disfunción Cognitiva/metabolismo
3.
Neuroradiology ; 65(10): 1459-1472, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37526657

RESUMEN

PURPOSE: Volume measurement using MRI is important to assess brain atrophy in multiple sclerosis (MS). However, differences between scanners, acquisition protocols, and analysis software introduce unwanted variability of volumes. To quantify theses effects, we compared within-scanner repeatability and between-scanner reproducibility of three different MR scanners for six brain segmentation methods. METHODS: Twenty-one people with MS underwent scanning and rescanning on three 3 T MR scanners (GE MR750, Philips Ingenuity, Toshiba Vantage Titan) to obtain 3D T1-weighted images. FreeSurfer, FSL, SAMSEG, FastSurfer, CAT-12, and SynthSeg were used to quantify brain, white matter and (deep) gray matter volumes both from lesion-filled and non-lesion-filled 3D T1-weighted images. We used intra-class correlation coefficient (ICC) to quantify agreement; repeated-measures ANOVA to analyze systematic differences; and variance component analysis to quantify the standard error of measurement (SEM) and smallest detectable change (SDC). RESULTS: For all six software, both between-scanner agreement (ICCs ranging 0.4-1) and within-scanner agreement (ICC range: 0.6-1) were typically good, and good to excellent (ICC > 0.7) for large structures. No clear differences were found between filled and non-filled images. However, gray and white matter volumes did differ systematically between scanners for all software (p < 0.05). Variance component analysis yielded within-scanner SDC ranging from 1.02% (SAMSEG, whole-brain) to 14.55% (FreeSurfer, CSF); and between-scanner SDC ranging from 4.83% (SynthSeg, thalamus) to 29.25% (CAT12, thalamus). CONCLUSION: Volume measurements of brain, GM and WM showed high repeatability, and high reproducibility despite substantial differences between scanners. Smallest detectable change was high, especially between different scanners, which hampers the clinical implementation of atrophy measurements.


Asunto(s)
Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Sustancia Gris/patología , Estudios Transversales , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Atrofia/patología , Programas Informáticos
4.
Artículo en Inglés | MEDLINE | ID: mdl-35649699

RESUMEN

BACKGROUND: The predictive value of serum neurofilament light chain (sNfL) on long-term prognosis in multiple sclerosis (MS) is still unclear. OBJECTIVE: Investigate the relation between sNfL levels over a 2-year period in patients with relapsing-remitting MS, and clinical disability and grey matter (GM) atrophy after 10 years. METHODS: 85 patients, originally enrolled in a multicentre, randomised trial of ω-3 fatty acids, participated in a 10-year follow-up visit. sNfL levels were measured by Simoa quarterly until month 12, and then at month 24. The appearance of new gadolinium-enhancing (Gd+) lesions was assessed monthly between baseline and month 9, and then at months 12 and 24. At the 10-year follow-up visit, brain atrophy measures were obtained using FreeSurfer. RESULTS: Higher mean sNfL levels during early periods of active inflammation (Gd+ lesions present or recently present) predicted lower total (ß=-0.399, p=0.040) and deep (ß=-0.556, p=0.010) GM volume, lower mean cortical thickness (ß=-0.581, p=0.010) and higher T2 lesion count (ß=0.498, p=0.018). Of the clinical outcomes, higher inflammatory sNfL levels were associated with higher disability measured by the dominant hand Nine-Hole Peg Test (ß=0.593, p=0.004). Mean sNfL levels during periods of remission (no Gd+ lesions present or recently present) did not predict GM atrophy or disability progression. CONCLUSION: Higher sNfL levels during periods of active inflammation predicted more GM atrophy and specific aspects of clinical disability 10 years later. The findings suggest that subsequent long-term GM atrophy is mainly due to neuroaxonal degradation within new lesions.

5.
Eur Radiol ; 32(5): 3576-3587, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34978580

RESUMEN

OBJECTIVE: To determine whether reliable brain atrophy measures can be obtained from post-contrast 3D T1-weighted images in patients with multiple sclerosis (MS) using FreeSurfer. METHODS: Twenty-two patients with MS were included, in which 3D T1-weighted MR images were obtained during the same scanner visit, with the same acquisition protocol, before and after administration of gadolinium-based contrast agents (GBCAs). Two FreeSurfer versions (v.6.0.1 and v.7.1.1.) were applied to calculate grey matter (GM) and white matter (WM) volumes and global and regional cortical thickness. The consistency between measures obtained in pre- and post-contrast images was assessed by intra-class correlation coefficient (ICC), the difference was investigated by paired t-tests, and the mean percentage increase or decrease was calculated for total WM and GM matter volume, total deep GM and thalamus volume, and mean cortical thickness. RESULTS: Good to excellent reliability was found between all investigated measures, with ICC ranging from 0.926 to 0.996, all p values < 0.001. GM volumes and cortical thickness measurements were significantly higher in post-contrast images by 3.1 to 17.4%, while total WM volume decreased significantly by 1.7% (all p values < 0.001). CONCLUSION: The consistency between values obtained from pre- and post-contrast images was excellent, suggesting it may be possible to extract reliable brain atrophy measurements from T1-weighted images acquired after administration of GBCAs, using FreeSurfer. However, absolute values were systematically different between pre- and post-contrast images, meaning that such images should not be compared directly. Potential systematic effects, possibly dependent on GBCA dose or the delay time after contrast injection, should be investigated. TRIAL REGISTRATION: Clinical trials.gov. identifier: NCT00360906. KEY POINTS: • The influence of gadolinium-based contrast agents (GBCAs) on atrophy measurements is still largely unknown and challenges the use of a considerable source of historical and prospective real-world data. • In 22 patients with multiple sclerosis, the consistency between brain atrophy measurements obtained from pre- and post-contrast images was excellent, suggesting it may be possible to extract reliable atrophy measurements in T1-weighted images acquired after administration of GBCAs, using FreeSurfer. • Absolute values were systematically different between pre- and post-contrast images, meaning that such images should not be compared directly, and measurements extracted from certain regions (e.g., the temporal pole) should be interpreted with caution.


Asunto(s)
Enfermedades del Sistema Nervioso Central , Esclerosis Múltiple , Enfermedades Neurodegenerativas , Atrofia/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Medios de Contraste , Gadolinio , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/patología , Humanos , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Enfermedades Neurodegenerativas/patología , Estudios Prospectivos , Reproducibilidad de los Resultados
6.
J Neurol ; 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39008036

RESUMEN

BACKGROUND: Digital monitoring of people with multiple sclerosis (PwMS) using smartphone-based monitoring tools is a promising method to assess disease activity and progression. OBJECTIVE: To study cross-sectional and longitudinal associations between active and passive digital monitoring parameters and MRI volume measures in PwMS. METHODS: In this prospective study, 92 PwMS were included. Clinical tests [Expanded Disability Status Scale (EDSS), Timed 25 Foot Walk test (T25FW), 9-Hole Peg Test (NHPT), and Symbol Digit Modalities Test (SDMT)] and structural MRI scans were performed at baseline (M0) and 12-month follow-up (M12). Active monitoring included the smartphone-based Symbol Digit Modalities Test (sSDMT) and 2 Minute Walk Test (s2MWT), while passive monitoring was based on smartphone keystroke dynamics (KD). Linear regression analyses were used to determine cross-sectional and longitudinal relations between digital and clinical outcomes and brain volumes, with age, disease duration and sex as covariates. RESULTS: In PwMS, both sSDMT and SDMT were associated with thalamic volumes and lesion volumes. KD were related to brain, ventricular, thalamic and lesion volumes. No relations were found between s2MWT and MRI volumes. NHPT scores were associated with lesion volumes only, while EDSS and T25FW were not related to MRI. No longitudinal associations were found for any of the outcome measures between M0 and M12. CONCLUSION: Our results show clear cross-sectional correlations between digital biomarkers and brain volumes in PwMS, which were not all present for conventional clinical outcomes, supporting the potential added value of digital monitoring tools.

7.
Neuroimage Clin ; 38: 103397, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37086648

RESUMEN

BACKGROUND: White matter (WM) lesions and brain atrophy are present early in multiple sclerosis (MS). However, their spatio-temporal relationship remains unclear. METHODS: Yearly magnetic resonance images were analysed in 387 patients with a first clinical demyelinating event (FCDE) from the 5-year REFLEXION study. Patients received early (from baseline; N = 258; ET) or delayed treatment (from month-24; N = 129; DT) with subcutaneous interferon beta-1a. FSL-SIENA/VIENA were used to provide yearly percentage volume change of brain (PBVC) and ventricles (PVVC). Yearly total lesion volume change (TLVC) was determined by a semi-automated method. Using linear mixed models and voxel-wise analyses, we firstly investigated the overall relationship between TLVC and PBVC and between TLVC and PVVC in the same follow-up period. Analyses were then separately performed for: the untreated period of DT patients (first two years), the first year of treatment (year 1 for ET and year 3 for DT), and a period where patients had received at least 1 year of treatment (stable treatment; ET: years 2, 3, 4, and 5; DT: years 4 and 5). RESULTS: Whole brain: across the whole study period, lower TLVC was related to faster atrophy (PBVC: B = 0.046, SE = 0.013, p < 0.001; PVVC: B = -0.466, SE = 0.118, p < 0.001). Within the untreated period of DT patients, lower TLVC was related to faster atrophy (PBVC: B = 0.072, SE = 0.029, p = 0.013; PVVC: B = -0.917, SE = 0.306, p = 0.003). A similar relationship was found within the first year of treatment of ET patients (PBVC: B = 0.081, SE = 0.027, p = 0.003; PVVC: B = -1.08, SE = 0.284, p < 0.001), consistent with resolving oedema and pseudo-atrophy. Voxel-wise: overall, higher TLVC was related to faster ventricular enlargement. Lower TLVC was related to faster widespread atrophy in year 1 in both ET (first year of treatment) and DT (untreated) patients. In the second untreated year of DT patients and within the stable treatment period of ET patients (year 4), faster periventricular and occipital lobe atrophy was associated with higher TLVC. CONCLUSIONS: WM lesion changes and atrophy occurred simultaneously in early MS. Spatio-temporal correspondence of these two processes involved mostly the periventricular area. Within the first year of the study, in both treatment groups, faster atrophy was linked to lower lesion volume changes, consistent with higher shrinking and disappearing lesion activity. This might reflect the pseudo-atrophy phenomenon that is probably related to the therapy driven (only in ET patients, as they received treatment from baseline) and "natural" (both ET and DT patients entered the study after a FCDE) resolution of oedema. In an untreated period and later on during stable treatment, (real) atrophy was related to higher lesion volume changes, consistent with increased new and enlarging lesion activity.


Asunto(s)
Esclerosis Múltiple , Humanos , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/tratamiento farmacológico , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Interferón beta-1a/uso terapéutico , Imagen por Resonancia Magnética/métodos , Atrofia/patología , Progresión de la Enfermedad
8.
Mult Scler Relat Disord ; 60: 103713, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35272146

RESUMEN

BACKGROUND: Upper cervical cord atrophy and lesions have been shown to be associated with disease and disability progression already in early relapsing-remitting multiple sclerosis (RRMS). However, their longitudinal relationship remains unclear. OBJECTIVE: To investigate the cross-sectional and longitudinal relation between focal T2 cervical cord lesion volume (CCLV) and regional and global mean upper cervical cord area (UCCA), and their relations with disability. METHODS: Over a two-year interval, subjects with RRMS (n = 36) and healthy controls (HC, n = 16) underwent annual clinical and MRI examinations. UCCA and CCLV were obtained from C1 through C4 level. Linear mixed model analysis was performed to investigate the relation between UCCA, CCLV, and disability over time. RESULTS: UCCA at baseline was significantly lower in RRMS subjects compared to HCs (p = 0.003), but did not decrease faster over time (p ≥ 0.144). UCCA and CCLV were independent of each other at any of the time points or cervical levels, and over time. Lower baseline UCCA, but not CCLV, was related to worsening of both upper and lower extremities function over time. CONCLUSION: UCCA and CCLV are independent from each other, both cross-sectionally and longitudinally, in early MS. Lower UCCA, but not CCLV, was related to increasing disability over time.


Asunto(s)
Médula Cervical , Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Atrofia/patología , Médula Cervical/diagnóstico por imagen , Médula Cervical/patología , Estudios Transversales , Evaluación de la Discapacidad , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/patología , Médula Espinal/patología
9.
Artículo en Inglés | MEDLINE | ID: mdl-35738901

RESUMEN

BACKGROUND AND OBJECTIVES: The relationship between smoking, long-term brain atrophy, and clinical disability in patients with multiple sclerosis (MS) is unclear. Here, we assessed long-term effects of smoking by evaluating MRI and clinical outcome measures after 10 years in smoking and nonsmoking patients with relapsing-remitting MS (RRMS). METHODS: We included 85 treatment-naive patients with RRMS with recent inflammatory disease activity who participated in a 10-year follow-up visit after a multicenter clinical trial of 24 months. Smoking status was decided for each patient by 2 separate definitions: by serum cotinine levels measured regularly for the first 2 years of the follow-up (during the clinical trial) and by retrospective patient self-reporting. At the 10-year follow-up visit, clinical tests were repeated, and brain atrophy measures were obtained from MRI using FreeSurfer. Differences in clinical and MRI measurements at the 10-year follow-up between smokers and nonsmokers were investigated by 2-sample t tests or Mann-Whitney tests and linear mixed-effect regression models. All analyses were conducted separately for each definition of smoking status. RESULTS: After 10 years, smoking (defined by serum cotinine levels) was associated with lower total white matter volume (ß = -21.74, p = 0.039) and higher logT2 lesion volume (ß = 0.22, p = 0.011). When defining smoking status by patient self-reporting, the repeated analyses found an additional association with lower deep gray matter volume (ß = -2.35, p = 0.049), and smoking was also associated with a higher score (higher walking impairment) on the log timed 25-foot walk test (ß = 0.050, p = 0.039) after 10 years and a larger decrease in paced auditory serial addition test (attention) scores (ß = -3.58, p = 0.029). DISCUSSION: Smoking was associated with brain atrophy and disability progression 10 years later in patients with RRMS. The findings imply that patients should be advised and offered aid in smoking cessation shortly after diagnosis, to prevent long-term disability progression.


Asunto(s)
Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Atrofia/patología , Cotinina , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/patología , Humanos , Esclerosis Múltiple/patología , Esclerosis Múltiple Recurrente-Remitente/patología , Estudios Retrospectivos , Fumar/efectos adversos
10.
Neuroimage Clin ; 36: 103220, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36274376

RESUMEN

BACKGROUND: White matter lesions and brain atrophy are both present early in multiple sclerosis. However, the spatio-temporal relationship between atrophy and lesion processes remains unclear. METHODS: Yearly magnetic resonance images were analyzed in 392 patients with clinically isolated syndrome from the 5-year REFLEX/REFLEXION studies. Patients received early treatment (from baseline; N = 262) or delayed treatment (from month-24; N = 130) with subcutaneous interferon beta-1a. Global and central atrophy were assessed using FSL-SIENA to provide yearly percentage volume change of brain and ventricles, respectively. Yearly total lesion volume change was calculated by subtracting the sum of the negative lesion volume change (disappearing + shrinking) from the positive lesion volume change (new + enlarging) for each yearly interval, as determined by an in-house developed semi-automated method. Using linear mixed models, during the period where patients had received ≥1 year of treatment, we investigated whether total lesion volume change was associated with percentage brain volume change or percentage ventricular volume change in the next year, and vice versa. RESULTS: Higher total lesion volume change was related to significantly faster global atrophy (percentage brain volume change) in the next year (B = - 0.113, SE = 0.022, p < 0.001). In patients receiving early treatment only, total lesion volume change was also associated with percentage ventricular volume change in the next year (B = 1.348, SE = 0.181, p < 0.001). Voxel-wise analyses showed that in patients receiving early treatment, higher total lesion volume change in years 2, 3, and 4 was related to faster atrophy in the next year, and in year 4 this relationship was stronger in patients receiving delayed treatment. Interestingly, faster atrophy was related to higher total lesion volume change in the next year (percentage brain volume change: B = - 0.136, SE = 0.062, p = 0.028; percentage ventricular volume change: B = 0.028, SE = 0.008, p < 0.001). CONCLUSIONS: Higher lesion volume changes were associated with faster atrophy in the next year. Interestingly, there was also an association between faster atrophy and higher lesion volume changes in the next year.


Asunto(s)
Enfermedades Desmielinizantes , Esclerosis Múltiple , Enfermedades Neurodegenerativas , Sustancia Blanca , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología , Progresión de la Enfermedad , Atrofia/patología , Enfermedades Desmielinizantes/patología , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Enfermedades Neurodegenerativas/patología
11.
Front Neurol ; 12: 693333, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34421797

RESUMEN

Background: Considerable spinal cord (SC) atrophy occurs in multiple sclerosis (MS). While MRI-based techniques for SC cross-sectional area (CSA) quantification have improved over time, there is no common agreement on whether to measure at single vertebral levels or across larger regions and whether upper SC CSA can be reliably measured from brain images. Aim: To compare in a multicenter setting three CSA measurement methods in terms of repeatability at different anatomical levels. To analyze the agreement between measurements performed on the cervical cord and on brain MRI. Method: One healthy volunteer was scanned three times on the same day in six sites (three scanner vendors) using a 3T MRI protocol including sagittal 3D T1-weighted imaging of the brain (covering the upper cervical cord) and of the SC. Images were analyzed using two semiautomated methods [NeuroQLab (NQL) and the Active Surface Model (ASM)] and the fully automated Spinal Cord Toolbox (SCT) on different vertebral levels (C1-C2; C2/3) on SC and brain images and the entire cervical cord (C1-C7) on SC images only. Results: CSA estimates were significantly smaller using SCT compared to NQL and ASM (p < 0.001), regardless of the cord level. Inter-scanner repeatability was best in C1-C7: coefficients of variation for NQL, ASM, and SCT: 0.4, 0.6, and 1.0%, respectively. CSAs estimated in brain MRI were slightly lower than in SC MRI (all p ≤ 0.006 at the C1-C2 level). Despite protocol harmonization between the centers with regard to image resolution and use of high-contrast 3D T1-weighted sequences, the variability of CSA was partly scanner dependent probably due to differences in scanner geometry, coil design, and details of the MRI parameter settings. Conclusion: For CSA quantification, dedicated isotropic SC MRI should be acquired, which yielded best repeatability in the entire cervical cord. In the upper part of the cervical cord, use of brain MRI scans entailed only a minor loss of CSA repeatability compared to SC MRI. Due to systematic differences between scanners and the CSA quantification software, both should be kept constant within a study. The MRI dataset of this study is available publicly to test new analysis approaches.

12.
Neuroimage Clin ; 29: 102550, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33418173

RESUMEN

BACKGROUND: As disease progression remains poorly understood in multiple sclerosis (MS), we aim to investigate the sequence in which different disease milestones occur using a novel data-driven approach. METHODS: We analysed a cohort of 295 relapse-onset MS patients and 96 healthy controls, and considered 28 features, capturing information on T2-lesion load, regional brain and spinal cord volumes, resting-state functional centrality ("hubness"), microstructural tissue integrity of major white matter (WM) tracts and performance on multiple cognitive tests. We used a discriminative event-based model to estimate the sequence of biomarker abnormality in MS progression in general, as well as specific models for worsening physical disability and cognitive impairment. RESULTS: We demonstrated that grey matter (GM) atrophy of the cerebellum, thalamus, and changes in corticospinal tracts are early events in MS pathology, whereas other WM tracts as well as the cognitive domains of working memory, attention, and executive function are consistently late events. The models for disability and cognition show early functional changes of the default-mode network and earlier changes in spinal cord volume compared to the general MS population. Overall, GM atrophy seems crucial due to its early involvement in the disease course, whereas WM tract integrity appears to be affected relatively late despite the early onset of WM lesions. CONCLUSION: Data-driven modelling revealed the relative occurrence of both imaging and non-imaging events as MS progresses, providing insights into disease propagation mechanisms, and allowing fine-grained staging of patients for monitoring purposes.


Asunto(s)
Esclerosis Múltiple , Sustancia Blanca , Atrofia/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Cognición , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/patología , Humanos , Imagen por Resonancia Magnética , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
13.
Neuroimage Clin ; 29: 102549, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33401136

RESUMEN

BACKGROUND AND RATIONALE: Thalamus atrophy has been linked to cognitive decline in multiple sclerosis (MS) using various segmentation methods. We investigated the consistency of the association between thalamus volume and cognition in MS for two common automated segmentation approaches, as well as fully manual outlining. METHODS: Standardized neuropsychological assessment and 3-Tesla 3D-T1-weighted brain MRI were collected (multi-center) from 57 MS patients and 17 healthy controls. Thalamus segmentations were generated manually and using five automated methods. Agreement between the algorithms and manual outlines was assessed with Bland-Altman plots; linear regression assessed the presence of proportional bias. The effect of segmentation method on the separation of cognitively impaired (CI) and preserved (CP) patients was investigated through Generalized Estimating Equations; associations with cognitive measures were investigated using linear mixed models, for each method and vendor. RESULTS: In smaller thalami, automated methods systematically overestimated volumes compared to manual segmentations [ρ=(-0.42)-(-0.76); p-values < 0.001). All methods significantly distinguished CI from CP MS patients, except manual outlines of the left thalamus (p = 0.23). Poorer global neuropsychological test performance was significantly associated with smaller thalamus volumes bilaterally using all methods. Vendor significantly affected the findings. CONCLUSION: Automated and manual thalamus segmentation consistently demonstrated an association between thalamus atrophy and cognitive impairment in MS. However, a proportional bias in smaller thalami and choice of MRI acquisition system might impact the effect size of these findings.


Asunto(s)
Esclerosis Múltiple , Atrofia , Cognición , Humanos , Imagen por Resonancia Magnética , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/diagnóstico por imagen , Tálamo/diagnóstico por imagen
14.
Front Neurol ; 11: 575611, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33281710

RESUMEN

Background: In early multiple sclerosis (MS), thalamus atrophy and decreased integrity of the thalamocortical white matter (WM) tracts have been observed. Objective: To investigate the temporal association between thalamus volume and WM damage in the thalamocortical tract in subjects with early MS. Methods: At two time points, 72 subjects with early MS underwent T1, FLAIR and diffusion tensor imaging. Thalamocortical tracts were identified with probabilistic tractography using left and right thalamus as seed regions. Regression analysis was performed to identify predictors of annual percentage change in both thalamus volumes and integrity of the connected tracts. Results: Significant atrophy was seen in left and right thalamus (p < 0.001) over the follow-up period (13.7 ± 4.8 months), whereas fractional anisotropy (FA) and mean diffusivity (MD) changes of the left and right thalamus tracts were not significant, although large inter-subject variability was seen. Annual percentage change in left thalamus volume was significantly predicted by baseline FA of the left thalamus tracts F (1.71) = 4.284, p = 0.042; while no such relation was found for the right thalamus. Annual percentage change in FA or MD of the thalamus tracts was not predicted by thalamus volume or any of the demographic parameters. Conclusion: Over a short follow-up time, thalamus atrophy could be predicted by decreased integrity of the thalamic tracts, but changes in the integrity of the thalamic tracts could not be predicted by thalamus volume. This is the first study showing directionality in the association between thalamus atrophy and connected WM tract damage. These results need to be verified over longer follow-up periods.

15.
J Neurol ; 267(12): 3541-3554, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32621103

RESUMEN

BACKGROUND: Deep grey matter (DGM) atrophy in multiple sclerosis (MS) and its relation to cognitive and clinical decline requires accurate measurements. MS pathology may deteriorate the performance of automated segmentation methods. Accuracy of DGM segmentation methods is compared between MS and controls, and the relation of performance with lesions and atrophy is studied. METHODS: On images of 21 MS subjects and 11 controls, three raters manually outlined caudate nucleus, putamen and thalamus; outlines were combined by majority voting. FSL-FIRST, FreeSurfer, Geodesic Information Flow and volBrain were evaluated. Performance was evaluated volumetrically (intra-class correlation coefficient (ICC)) and spatially (Dice similarity coefficient (DSC)). Spearman's correlations of DSC with global and local lesion volume, structure of interest volume (ROIV), and normalized brain volume (NBV) were assessed. RESULTS: ICC with manual volumes was mostly good and spatial agreement was high. MS exhibited significantly lower DSC than controls for thalamus and putamen. For some combinations of structure and method, DSC correlated negatively with lesion volume or positively with NBV or ROIV. Lesion-filling did not substantially change segmentations. CONCLUSIONS: Automated methods have impaired performance in patients. Performance generally deteriorated with higher lesion volume and lower NBV and ROIV, suggesting that these may contribute to the impaired performance.


Asunto(s)
Esclerosis Múltiple , Atrofia/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/patología , Humanos , Imagen por Resonancia Magnética , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología
16.
Neuroimage Clin ; 21: 101667, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30665101

RESUMEN

Brain volume loss, or atrophy, has been proven to be an important characteristic of neurological diseases such as Alzheimer's disease and multiple sclerosis. To use atrophy rate as a reliable clinical biomarker and to increase statistical power in clinical treatment trials, measurement variability needs to be minimized. Among other sources, systematic differences between different MR scanners are suspected to contribute to this variability. In this study we developed and performed initial validation tests of an MR-compatible phantom and analysis software for robust and reliable evaluation of the brain volume loss. The phantom contained three inflatable models of brain structures, i.e. cerebral hemisphere, putamen, and caudate nucleus. Software to reliably quantify volumes form the phantom images was also developed. To validate the method, the phantom was imaged using 3D T1-weighted protocols at three clinical 3T MR scanners from different vendors. Calculated volume change from MRI was compared with the known applied volume change using ICC and mean absolute difference. As assessed by the ICC, the agreement between our developed software and the applied volume change for different structures ranged from 0.999-1 for hemisphere, 0.976-0.998 for putamen, and 0.985-0.999 for caudate nucleus. The mean absolute differences between measured and applied volume change were 109-332 µL for hemisphere, 2.9-11.9 µL for putamen, and 2.2-10.1 µL for caudate nucleus. This method offers a reliable and robust measurement of volume change using MR images and could potentially be used to standardize clinical measurement of atrophy rates.


Asunto(s)
Atrofia/patología , Encéfalo/patología , Interpretación de Imagen Asistida por Computador , Fantasmas de Imagen , Enfermedad de Alzheimer/patología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/patología , Reproducibilidad de los Resultados , Programas Informáticos
17.
Stud Health Technol Inform ; 125: 361-6, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17377304

RESUMEN

A virtual reality surgical simulator ideally allows seamless transition between the real and virtual world. In that respect, all of a surgeon's motions and tools must be simulated. Until now researchers have been limited to using a pen-like tool in six degrees-of-freedom. This paper presents the addition of haptically enabled scissors to the end effector of a 6-DOF haptic device, the Freedom 6S. The scissors are capable of pinching a maximum torque of 460 mN.m with low inertia and low back-drive friction. The device is a balanced design so that the user feels like they are holding no more than actual scissors, although with some added inertia on the load end. The system is interchangeable between the 6-DOF and 7-DOF configurations to allow switching tools quickly.


Asunto(s)
Retroalimentación , Cirugía General/instrumentación , Tacto , Interfaz Usuario-Computador , Canadá , Simulación por Computador
18.
PLoS One ; 8(3): e58246, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23516452

RESUMEN

Plants are able to sense the magnitude and direction of gravity. This capacity is thought to reside in selected cell types within the plant body that are equipped with specialized organelles called statoliths. However, most plant cells do not possess statoliths, yet they respond to changes in gravitational acceleration. To understand the effect of gravity on the metabolism and cellular functioning of non-specialized plant cells, we investigated a rapidly growing plant cell devoid of known statoliths and without gravitropic behavior, the pollen tube. The effects of hyper-gravity and omnidirectional exposure to gravity on intracellular trafficking and on cell wall assembly were assessed in Camellia pollen tubes, a model system with highly reproducible growth behavior in vitro. Using an epi-fluorescence microscope mounted on the Large Diameter Centrifuge at the European Space Agency, we were able to demonstrate that vesicular trafficking is reduced under hyper-gravity conditions. Immuno-cytochemistry confirmed that both in hyper and omnidirectional gravity conditions, the characteristic spatial profiles of cellulose and callose distribution in the pollen tube wall were altered, in accordance with a dose-dependent effect on pollen tube diameter. Our findings suggest that in response to gravity induced stress, the pollen tube responds by modifying cell wall assembly to compensate for the altered mechanical load. The effect was reversible within few minutes demonstrating that the pollen tube is able to quickly adapt to changing stress conditions.


Asunto(s)
Pared Celular/metabolismo , Gravitación , Células Vegetales/metabolismo , Transporte Biológico , Celulosa/metabolismo , Vesículas Citoplasmáticas/metabolismo , Germinación , Glucanos/metabolismo , Espacio Intracelular , Tubo Polínico/citología , Tubo Polínico/crecimiento & desarrollo , Tubo Polínico/metabolismo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda