Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38630867

RESUMEN

AIMS: Photoplethysmography- (PPG) based smartphone applications facilitate heart rate and rhythm monitoring in patients with paroxysmal and persistent atrial fibrillation (AF). Despite an endorsement from the European Heart Rhythm Association, validation studies in this setting are lacking. Therefore, we evaluated the accuracy of PPG-derived heart rate and rhythm classification in subjects with an established diagnosis of AF in unsupervised real-world conditions. METHODS AND RESULTS: Fifty consecutive patients were enrolled, 4 weeks before undergoing AF ablation. Patients used a handheld single-lead electrocardiography (ECG) device and a fingertip PPG smartphone application to record 3907 heart rhythm measurements twice daily during 8 weeks. The ECG was performed immediately before and after each PPG recording and was given a diagnosis by the majority of three blinded cardiologists. A consistent ECG diagnosis was exhibited along with PPG data of sufficient quality in 3407 measurements. A single measurement exhibited good quality more often with ECG (93.2%) compared to PPG (89.5%; P < 0.001). However, PPG signal quality improved to 96.6% with repeated measurements. Photoplethysmography-based detection of AF demonstrated excellent sensitivity [98.3%; confidence interval (CI): 96.7-99.9%], specificity (99.9%; CI: 99.8-100.0%), positive predictive value (99.6%; CI: 99.1-100.0%), and negative predictive value (99.6%; CI: 99.0-100.0%). Photoplethysmography underestimated the heart rate in AF with 6.6 b.p.m. (95% CI: 5.8 b.p.m. to 7.4 b.p.m.). Bland-Altman analysis revealed increased underestimation in high heart rates. The root mean square error was 11.8 b.p.m. CONCLUSION: Smartphone applications using PPG can be used to monitor patients with AF in unsupervised real-world conditions. The accuracy of AF detection algorithms in this setting is excellent, but PPG-derived heart rate may tend to underestimate higher heart rates.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Teléfono Inteligente , Fotopletismografía , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Electrocardiografía/métodos , Algoritmos
2.
Sensors (Basel) ; 24(6)2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38544153

RESUMEN

Repeated single-point measurements of thoracic bioimpedance at a single (low) frequency are strongly related to fluid changes during hemodialysis. Extension to semi-continuous measurements may provide longitudinal details in the time pattern of the bioimpedance signal, and multi-frequency measurements may add in-depth information on the distribution between intra- and extracellular fluid. This study aimed to investigate the feasibility of semi-continuous multi-frequency thoracic bioimpedance measurements by a wearable device in hemodialysis patients. Therefore, thoracic bioimpedance was recorded semi-continuously (i.e., every ten minutes) at nine frequencies (8-160 kHz) in 68 patients during two consecutive hemodialysis sessions, complemented by a single-point measurement at home in-between both sessions. On average, the resistance signals increased during both hemodialysis sessions and decreased during the interdialytic interval. The increase during dialysis was larger at 8 kHz (∆ 32.6 Ω during session 1 and ∆ 10 Ω during session 2), compared to 160 kHz (∆ 29.5 Ω during session 1 and ∆ 5.1 Ω during session 2). Whereas the resistance at 8 kHz showed a linear time pattern, the evolution of the resistance at 160 kHz was significantly different (p < 0.0001). Measuring bioimpedance semi-continuously and with a multi-frequency current is a major step forward in the understanding of fluid dynamics in hemodialysis patients. This study paves the road towards remote fluid monitoring.


Asunto(s)
Diálisis Renal , Dispositivos Electrónicos Vestibles , Humanos , Estudios de Factibilidad , Impedancia Eléctrica , Líquido Extracelular
3.
Nutrients ; 16(5)2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38474720

RESUMEN

Increasing research has indicated a strong association between identity functioning and eating disorder (ED) symptomatology. However, a detailed investigation of identity throughout ED treatment is lacking. The present longitudinal study examined identity in inpatients with an ED and explored its simultaneous change with ED symptomatology throughout treatment. A total of 225 female patients completed questionnaires at admission. From these 225 patients participating at admission (Wave 1), 110 also participated in at least one additional measurement wave, with 43.64% (n = 48) participating at admission and during treatment, 16.36% (n = 18) participating at admission and at discharge, and 40% (n = 44) participating at admission, during treatment and at discharge. Questionnaires on identity synthesis, identity confusion, identity processes, and ED symptomatology were completed. Latent growth curve modeling was used to address the research questions. Throughout treatment, a decrease in identity confusion and an increase in identity synthesis and adaptive identity processes were found. Accordingly, increases in identity synthesis and identification with commitment were related to general decreases in the drive for thinness and body dissatisfaction. Similarly, such decreases in ED symptoms were related to general decreases in identity confusion and ruminative exploration. The present study points to an increase in identity functioning throughout treatment, and longitudinal associations between identity functioning and ED symptomatology were found. Helping patients to decrease their ruminative exploration and to increase their identification with previously made life commitments and treating body/weight concerns could both be helpful in ED treatment.


Asunto(s)
Trastornos de Alimentación y de la Ingestión de Alimentos , Humanos , Femenino , Estudios Longitudinales , Encuestas y Cuestionarios , Pacientes Internos
4.
Int J Hyg Environ Health ; 257: 114346, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38447259

RESUMEN

BACKGROUND: Studies on cognitive and neurodevelopmental outcomes have shown inconsistent results regarding the association with prenatal exposure to perfluoroalkyl substance (PFAS) and organochlorines. Assessment of mixture effects of correlated chemical exposures that persist in later life may contribute to the unbiased evaluation and understanding of dose-response associations in real-life exposures. METHODS: For a subset of the 4th Flemish Environment and Health Study (FLEHS), concentrations of four PFAS and six organochlorines were measured in respectively 99 and 153-160 cord plasma samples and 15 years later in adolescents' peripheral serum by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS). Sustained and selective attention were measured at 14-15 years with the Continuous Performance Test (CPT) and Stroop Test as indicators of potential neurodevelopmental deficits. Quantile g-computation was applied to assess the joint associations between prenatal exposure to separate and combined groups of PFAS and organochlorines and performance in the CPT and Stroop Test at adolescence. Subsequently, individual effects of each chemical compound were analyzed in mixed effects models with two sets of covariates. Analytical data at birth and at the time of cognitive assessment allowed for off-setting postnatal exposure. RESULTS: In mixtures analysis, a simultaneous one-quantile increase in the natural log-transformed values of PFAS and organochlorines combined was associated with a decrease in the mean reaction time (RT) and the reaction time variability (RTV) in the CPT (ß = -15.54, 95% CI:-29.64, -1.45, and ß = -7.82, 95% CI: -14.97, -0.67 respectively) and for the mixture of PFAS alone with RT (ß = -11.94, 95% CI: -23.29, -0.60). In the single pollutant models, these results were confirmed for the association between perfluorohexanesulfonate (PFHxS) with RT (ß = -17.95, 95% CI = -33.35, -2.69) and hexachlorobenzene with RTV in the CPT (ß = -5.78, 95% CI: -10.39, -0.76). Furthermore, the participants with prenatal exposure above the limit of quantification for perfluorononanoic acid (PFNA) had a significantly shorter RT and RTV in the CPT (ß = -23.38, 95% CI: -41.55, -5.94, and ß = -9.54, 95% CI: -19.75, -0.43, respectively). CONCLUSION: Higher prenatal exposure to a PFAS mixture and a mixture of PFAS and organochlorines combined was associated with better sustained and selective attention during adolescence. The associations seemed to be driven by PFHxS and were not linked to exposure levels at the time of assessment.


Asunto(s)
Ácidos Alcanesulfónicos , Contaminantes Ambientales , Fluorocarburos , Efectos Tardíos de la Exposición Prenatal , Femenino , Embarazo , Recién Nacido , Humanos , Adolescente , Cromatografía Liquida , Espectrometría de Masas en Tándem , Cognición
5.
Vaccine ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39019657

RESUMEN

BACKGROUND: To overcome supply issues of COVID-19 vaccines, this partially single blind, multi-centric, vaccine trial aimed to evaluate humoral immunogenicity using lower vaccine doses, intradermal vaccination, and heterologous vaccine schedules. Also, the immunity after a booster vaccination was assessed. METHODOLOGY: 566 COVID-19-naïve healthy adults were randomized to 1 of 8 treatment arms consisting of combinations of BNT162b2, mRNA-1273, and ChAdOx1-S. Anti-Receptor-Binding Domain immunoglobulin G (RBD IgG) titers, neutralizing antibody titres, and avidity of the anti-RBD IgGs was assessed up to 1 year after study start. RESULTS: Prolonging the interval between vaccinations from 28 to 84 days and the use of a heterologous BNT162b2 + mRNA-1273 vaccination schedule led to a non-inferior immune response, compared to the reference schedule. A low dose of mRNA-1273 was sufficient to induce non-inferior immunity. Non-inferiority could not be demonstrated for intradermal vaccination. For all adapted vaccination schedules, anti-RBD IgG titres measured after a first booster vaccination were non-inferior to their reference schedule. CONCLUSION: This study suggests that reference vaccine schedules can be adapted without jeopardizing the development of an adequate immune response. Immunity after a booster vaccination did not depend on the dose or brand of the booster vaccine, which is relevant for future booster campaigns. The trial is registered in the European Union Clinical Trials Register (number 2021-001993-52) and on clinicaltrials.gov (NCT06189040).

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda