Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
1.
Ear Hear ; 45(1): 62-71, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37415270

RESUMEN

OBJECTIVES: Early hearing detection and intervention (EHDI) is a newborn hearing screening system created to detect infants with hearing loss (HL) and intervene to reduce language and communication impairment. Early hearing detection (EHD) consists of three sequential stages: identification, screening, and diagnostic testing. This study longitudinally reviews each stage of EHD in each state and proposes a framework to improve utilization of EHD data. DESIGN: A retrospective public database review was conducted, accessing publicly available data from the Centers for Disease Control and Prevention. Summary descriptive statistics were utilized to generate a descriptive study of EHDI programs in each U.S. state from 2007 to 2016. RESULTS: Data over 10 years from 50 states as well as Washington, DC were included in this analysis, creating up to 510 data points per analysis. Hundred percent (85 to 105) (median [min to max]) of newborns were identified by and entered EHDI programs. Ninety-eight percent (51 to 100) of identified infants completed screening. Of the infants who screened positive for HL, the proportion that received diagnostic testing was 55% (1 to 100). The overall proportion of infants who failed to complete EHD was 3% (1 to 51). Of the infants who fail to complete EHD 70% (0 to 100) are from missed screenings, 24% (0 to 95) are from missed diagnostic testing, and 0% (0 to 93) are from missed identification. Although there are more infants missed at screening, it was estimated, with limitations, that there is an order of magnitude more infants with HL among those who did not complete diagnostic testing compared with those who did not complete screening. CONCLUSIONS: Analysis demonstrates high completion rates at both identification and screening stages, whereas the diagnostic testing stage demonstrates low and highly variable completion rates. The low completion rates at diagnostic testing create a bottleneck in the EHD process and the large variability impedes the comparison of HL outcomes across states. Analysis also demonstrates that among all stages of EHD, whereas the largest number of infants are missed at screening, the largest number of children with HL are likely missed at diagnostic testing. Therefore, a focus by individual EHDI programs on addressing causes of low diagnostic testing completion rates would yield the greatest increase in the identification of children with HL. Potential causes of low diagnostic testing completion rates are further discussed. Finally, a new vocabulary framework is proposed to facilitate further study of EHD outcomes.


Asunto(s)
Sordera , Pérdida Auditiva , Lactante , Niño , Recién Nacido , Humanos , Estudios Retrospectivos , Tamizaje Neonatal , Pérdida Auditiva/diagnóstico , Sordera/diagnóstico , Pruebas Auditivas , Audición
2.
Ear Hear ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880958

RESUMEN

OBJECTIVES: Modern cochlear implants (CIs) use varying-length electrode arrays inserted at varying insertion angles within variably sized cochleae. Thus, there exists an opportunity to enhance CI performance, particularly in postlinguistic adults, by optimizing the frequency-to-place allocation for electrical stimulation, thereby minimizing the need for central adaptation and plasticity. There has been interest in applying Greenwood or Stakhovskaya et al. function (describing the tonotopic map) to postoperative imaging of electrodes to improve frequency allocation and place coding. Acoustically-evoked electrocochleography (ECochG) allows for electrophysiologic best-frequency (BF) determination of CI electrodes and the potential for creating a personalized frequency allocation function. The objective of this study was to investigate the correlation between early speech-perception performance and frequency-to-place mismatch. DESIGN: This retrospective study included 50 patients who received a slim perimodiolar electrode array. Following electrode insertion, five acoustic pure-tone stimuli ranging from 0.25 to 2 kHz were presented, and electrophysiological measurements were collected across all 22 electrode contacts. Cochlear microphonic tuning curves were subsequently generated for each stimulus frequency to ascertain the BF electrode or the location corresponding to the maximum response amplitude. Subsequently, we calculated the difference between the stimulus frequency and the patient's CI map's actual frequency allocation at each BF electrode, reflecting the frequency-to-place mismatch. BF electrocochleography-total response (BF-ECochG-TR), a measure of cochlear health, was also evaluated for each subject to control for the known impact of this measure on performance. RESULTS: Our findings showed a moderate correlation (r = 0.51; 95% confidence interval: 0.23 to 0.76) between the cumulative frequency-to-place mismatch, as determined using the ECochG-derived BF map (utilizing 500, 1000, and 2000 Hz), and 3-month performance on consonant-nucleus-consonant words (N = 38). Larger positive mismatches, shifted basal from the BF map, led to enhanced speech perception. Incorporating BF-ECochG-TR, total mismatch, and their interaction in a multivariate model explained 62% of the variance in consonant-nucleus-consonant word scores at 3 months. BF-ECochG-TR as a standalone predictor tended to overestimate performance for subjects with larger negative total mismatches and underestimated the performance for those with larger positive total mismatches. Neither cochlear diameter, number of cochlear turns, nor apical insertion angle accounted for the variability in total mismatch. CONCLUSIONS: Comparison of ECochG-BF derived tonotopic electrode maps to the frequency allocation tables reveals substantial mismatch, explaining 26.0% of the variability in CI performance in quiet. Closer examination of the mismatch shows that basally shifted maps at high frequencies demonstrate superior performance at 3 months compared with those with apically shifted maps (toward Greenwood and Stakhovskaya et al.). The implications of these results suggest that electrophysiological-based frequency reallocation might lead to enhanced speech-perception performance, especially when compared with conventional manufacturer maps or anatomic-based mapping strategies. Future research, exploring the prospective use of ECochG-based mapping techniques for frequency allocation is underway.

3.
Ear Hear ; 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39233326

RESUMEN

OBJECTIVES: Due to the challenges of direct in vivo measurements in humans, previous studies of cochlear tonotopy primarily utilized human cadavers and animal models. This study uses cochlear implant electrodes as a tool for intracochlear recordings of acoustically evoked responses to achieve two primary goals: (1) to map the in vivo tonotopy of the human cochlea, and (2) to assess the impact of sound intensity and the creation of an artificial "third window" on this tonotopic map. DESIGN: Fifty patients with hearing loss received cochlear implant electrode arrays. Postimplantation, pure-tone acoustic stimuli (0.25 to 4 kHz) were delivered, and electrophysiological responses were recorded from all 22 electrode contacts. The analysis included fast Fourier transformation to determine the amplitude of the first harmonic, indicative of predominantly outer hair cell activity, and tuning curves to identify the best frequency (BF) electrode. These measures, coupled with postoperative imaging for precise electrode localization, facilitated the construction of an in vivo frequency-position function. The study included a specific examination of 2 patients with auditory neuropathy spectrum disorder (ANSD), with preserved cochlear function as assessed by present distortion-product otoacoustic emissions, to determine the impact of sound intensity on the frequency-position map. In addition, the electrophysiological map was recorded in a patient undergoing a translabyrinthine craniotomy for vestibular schwannoma removal, before and after creating an artificial third window, to explore whether an experimental artifact conducted in cadaveric experiments, as was performed in von Békésy landmark experiments, would produce a shift in the frequency-position map. RESULTS: A significant deviation from the Greenwood model was observed in the electrophysiological frequency-position function, particularly at high-intensity stimulations. In subjects with hearing loss, frequency tuning, and BF location remained consistent across sound intensities. In contrast, ANSD patients exhibited Greenwood-like place coding at low intensities (~40 dB SPL) and a basal shift in BF location at higher intensities (~70 dB SPL or greater). Notably, creating an artificial "third-window" did not alter the frequency-position map. CONCLUSIONS: This study successfully maps in vivo tonotopy of human cochleae with hearing loss, demonstrating a near-octave shift from traditional frequency-position maps. In patients with ANSD, representing more typical cochlear function, intermediate intensity levels (~70 to 80 dB SPL) produced results similar to high-intensity stimulation. These findings highlight the influence of stimulus intensity on the cochlear operational point in subjects with hearing loss. This knowledge could enhance cochlear implant programming and improve auditory rehabilitation by more accurately aligning electrode stimulation with natural cochlear responses.

4.
Ear Hear ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38915137

RESUMEN

OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39287816

RESUMEN

PURPOSE: In cochlear implantation (CI) surgery, there are a wide variety of intraoperative tests available. However, no clear guide exists on which tests must be performed as the minimum intraoperative testing battery. Toward this end, we studied the usage patterns, recommendations, and attitudes of practitioners toward intraoperative testing. METHODS: This study is a multicentric international survey of tertiary referral CI centers. A survey was developed and administered to a group of CI practitioners (n = 34) including otologists, audiologists and biomedical engineers. Thirty six participants were invited to participate in this study based on a their scientific outputs to the literature on the intraoperative testing in CI field and based on their high load of CI surgeries. Thirty four, from 15 countries have accepted the invitation to participate. The participants were asked to indicate the usage trends, perceived value, influence on decision making and duration of each intraoperative test. They were also asked to indicate which tests they believe should be included in a minimum test battery for routine cases. RESULTS: Thirty-two (94%) experts provided responses. The most frequently recommended tests for a minimum battery were facial nerve monitoring, electrode impedance measurements, and measurements of electrically evoked compound action potentials (ECAPs). The perceived value and influence on surgical decision-making also varied, with high-resolution CT being rated the highest on both measures. CONCLUSION: Facial nerve monitoring, electrode impedance measurements, and ECAP measurements are currently the core tests of the intraoperative test battery for CI surgery.

6.
Ear Hear ; 42(4): 941-948, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33369942

RESUMEN

OBJECTIVES: Electrocochleography (ECochG), obtained before the insertion of a cochlear implant (CI) array, provides a measure of residual cochlear function that accounts for a substantial portion of variability in postoperative speech perception outcomes in adults. It is postulated that subsequent surgical factors represent independent sources of variance in outcomes. Prior work has demonstrated a positive correlation between angular insertion depth (AID) of straight arrays and speech perception under the CI-alone condition, with an inverse relationship observed for precurved arrays. The purpose of the present study was to determine the combined effects of ECochG, AID, and array design on speech perception outcomes. DESIGN: Participants were 50 postlingually deafened adult CI recipients who received one of three straight arrays (MED-EL Flex24, MED-EL Flex28, and MED-EL Standard) and two precurved arrays (Cochlear Contour Advance and Advanced Bionics HiFocus Mid-Scala). Residual cochlear function was determined by the intraoperative ECochG total response (TR) measured before array insertion, which is the sum of magnitudes of spectral components in response to tones of different stimulus frequencies across the speech spectrum. The AID was then determined with postoperative imaging. Multiple linear regression was used to predict consonant-nucleus-consonant (CNC) word recognition in the CI-alone condition at 6 months postactivation based on AID, TR, and array design. RESULTS: Forty-one participants received a straight array and nine received a precurved array. The AID of the most apical electrode contact ranged from 341° to 696°. The TR measured by ECochG accounted for 43% of variance in speech perception outcomes (p < 0.001). A regression model predicting CNC word scores with the TR tended to underestimate the performance for precurved arrays and deeply inserted straight arrays, and to overestimate the performance for straight arrays with shallower insertions. When combined in a multivariate linear regression, the TR, AID, and array design accounted for 72% of variability in speech perception outcomes (p < 0.001). CONCLUSIONS: A model of speech perception outcomes that incorporates TR, AID, and array design represents an improvement over a model based on TR alone. The success of this model shows that peripheral factors including cochlear health and electrode placement may play a predominant role in speech perception with CIs.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Audiometría de Respuesta Evocada , Cóclea/cirugía , Humanos
7.
Ear Hear ; 40(4): 833-848, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30335669

RESUMEN

OBJECTIVES: Electrocochleography (ECochG) obtained through a cochlear implant (CI) is increasingly being tested as an intraoperative monitor during implantation with the goal of reducing surgical trauma. Reducing trauma should aid in preserving residual hearing and improve speech perception overall. The purpose of this study was to characterize intracochlear ECochG responses throughout insertion in a range of array types and, when applicable, relate these measures to hearing preservation. The ECochG signal in cochlear implant subjects is complex, consisting of hair cell and neural generators with differing distributions depending on the etiology and history of hearing loss. Consequently, a focus was to observe and characterize response changes as an electrode advances. DESIGN: In 36 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then through the apical contact of the CI as the array advanced into the cochlea. The specific setup used a sterile clip in the surgical field, attached to the ground of the implant with a software-controlled short to the apical contact. The end of the clip was then connected to standard audiometric recording equipment. The stimuli were 500 Hz tone bursts at 90 dB nHL. Audiometry for cases with intended hearing preservation (12/36 subjects) was correlated with intraoperative recordings. RESULTS: Successful intracochlear recordings were obtained in 28 subjects. For the eight unsuccessful cases, the clip introduced excessive line noise, which saturated the amplifier. Among the successful subjects, the initial intracochlear response was a median 5.8 dB larger than the response at the RW. Throughout insertion, modiolar arrays showed median response drops after stylet removal while in lateral wall arrays the maximal median response magnitude was typically at the deepest insertion depth. Four main patterns of response magnitude were seen: increases > 5 dB (12/28), steady responses within 5 dB (4/28), drops > 5 dB (from the initial response) at shallow insertion depths (< 15 mm deep, 7/28), or drops > 5 dB occurring at deeper depths (5/28). Hearing preservation, defined as < 80 dB threshold at 250 Hz, was successful in 9/12 subjects. In these subjects, an intracochlear loss of response magnitude afforded a prediction model with poor sensitivity and specificity, which improved when phase, latency, and proportion of neural components was considered. The change in hearing thresholds across cases was significantly correlated with various measures of the absolute magnitudes of response, including RW response, starting response, maximal response, and final responses (p's < 0.05, minimum of 0.0001 for the maximal response, r's > 0.57, maximum of 0.80 for the maximal response). CONCLUSIONS: Monitoring the cochlea with intracochlear ECochG during cochlear implantation is feasible, and patterns of response vary by device type. Changes in magnitude alone did not account for hearing preservation rates, but considerations of phase, latency, and neural contribution can help to interpret the changes seen and improve sensitivity and specificity. The correlation between the absolute magnitude obtained either before or during insertion of the ECochG and the hearing threshold changes suggest that cochlear health, which varies by subject, plays an important role.


Asunto(s)
Audiometría de Respuesta Evocada/métodos , Cóclea/fisiopatología , Implantación Coclear/métodos , Pérdida Auditiva Sensorineural/rehabilitación , Monitoreo Intraoperatorio/métodos , Percepción del Habla , Adolescente , Adulto , Anciano , Niño , Preescolar , Cóclea/cirugía , Implantes Cocleares , Femenino , Audición , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Lactante , Masculino , Persona de Mediana Edad , Ventana Redonda , Adulto Joven
8.
Ear Hear ; 40(4): 1001-1008, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30531261

RESUMEN

OBJECTIVES: To (1) identify the etiologies and risk factors of the patient cohort and determine the degree to which they reflected the incidence for children with hearing loss and (2) quantify practice management patterns in three catchment areas of the United States with available centers of excellence in pediatric hearing loss. DESIGN: Medical information for 307 children with bilateral, mild-to-severe hearing loss was examined retrospectively. Children were participants in the Outcomes of Children with Hearing Loss (OCHL) study, a 5-year longitudinal study that recruited subjects at three different sites. Children aged 6 months to 7 years at time of OCHL enrollment were participants in this study. Children with cochlear implants, children with severe or profound hearing loss, and children with significant cognitive or motor delays were excluded from the OCHL study and, by extension, from this analysis. Medical information was gathered using medical records and participant intake forms, the latter reflecting a caregiver's report. A comparison group included 134 children with normal hearing. A Chi-square test on two-way tables was used to assess for differences in referral patterns by site for the children who are hard of hearing (CHH). Linear regression was performed on gestational age and birth weight as continuous variables. Risk factors were assessed using t tests. The alpha value was set at p < 0.05. RESULTS: Neonatal intensive care unit stay, mechanical ventilation, oxygen requirement, aminoglycoside exposure, and family history were correlated with hearing loss. For this study cohort, congenital cytomegalovirus, strep positivity, bacterial meningitis, extracorporeal membrane oxygenation, and loop diuretic exposure were not associated with hearing loss. Less than 50% of children underwent imaging, although 34.2% of those scanned had abnormalities identified. No single imaging modality was preferred. Differences in referral rates were apparent for neurology, radiology, genetics, and ophthalmology. CONCLUSIONS: The OCHL cohort reflects known etiologies of CHH. Despite available guidelines, centers of excellence, and high-yield rates for imaging, the medical workup for children with hearing loss remains inconsistently implemented and widely variable. There remains limited awareness as to what constitutes appropriate medical assessment for CHH.


Asunto(s)
Aminoglicósidos/uso terapéutico , Pérdida Auditiva Bilateral/epidemiología , Hospitalización/estadística & datos numéricos , Derivación y Consulta , Respiración Artificial/estadística & datos numéricos , Estudios de Casos y Controles , Áreas de Influencia de Salud , Niño , Preescolar , Femenino , Genética Médica , Pérdida Auditiva Bilateral/etiología , Humanos , Lactante , Unidades de Cuidado Intensivo Neonatal , Masculino , Anamnesis , Neurología , Oftalmología , Terapia por Inhalación de Oxígeno/estadística & datos numéricos , Radiología , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Estados Unidos/epidemiología
9.
Ear Hear ; 40(3): 577-591, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30169463

RESUMEN

OBJECTIVES: Variability in speech perception outcomes with cochlear implants remains largely unexplained. Recently, electrocochleography, or measurements of cochlear potentials in response to sound, has been used to assess residual cochlear function at the time of implantation. Our objective was to characterize the potentials recorded preimplantation in subjects of all ages, and evaluate the relationship between the responses, including a subjective estimate of neural activity, and speech perception outcomes. DESIGN: Electrocochleography was recorded in a prospective cohort of 284 candidates for cochlear implant at University of North Carolina (10 months to 88 years of ages). Measurement of residual cochlear function called the "total response" (TR), which is the sum of magnitudes of spectral components in response to tones of different stimulus frequencies, was obtained for each subject. The TR was then related to results on age-appropriate monosyllabic word score tests presented in quiet. In addition to the TR, the electrocochleography results were also assessed for neural activity in the forms of the compound action potential and auditory nerve neurophonic. RESULTS: The TR magnitude ranged from a barely detectable response of about 0.02 µV to more than 100 µV. In adults (18 to 79 years old), the TR accounted for 46% of variability in speech perception outcome by linear regression (r = 0.46; p < 0.001). In children between 6 and 17 years old, the variability accounted for was 36% (p < 0.001). In younger children, the TR accounted for less of the variability, 15% (p = 0.012). Subjects over 80 years old tended to perform worse for a given TR than younger adults at the 6-month testing interval. The subjectively assessed neural activity did not increase the information compared with the TR alone, which is primarily composed of the cochlear microphonic produced by hair cells. CONCLUSIONS: The status of the auditory periphery, particularly of hair cells rather than neural activity, accounts for a large fraction of variability in speech perception outcomes in adults and older children. In younger children, the relationship is weaker, and the elderly differ from other adults. This simple measurement can be applied with high throughput so that peripheral status can be assessed to help manage patient expectations, create individually-tailored treatment plans, and identify subjects performing below expectations based on residual cochlear function.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Sensorineural/rehabilitación , Percepción del Habla , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Audiometría de Respuesta Evocada , Niño , Preescolar , Implantes Cocleares , Estudios de Cohortes , Femenino , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
10.
Ear Hear ; 39(2): 326-336, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29023243

RESUMEN

OBJECTIVES: The objectives of this study were to demonstrate the safety of auditory brainstem implant (ABI) surgery and document the subsequent development of auditory and spoken language skills in children without neurofibromatosis type II (NFII). DESIGN: A prospective, single-subject observational study of ABI in children without NFII was undertaken at the University of North Carolina at Chapel Hill. Five children were enrolled under an investigational device exemption sponsored by the investigators. Over 3 years, patient demographics, medical/surgical findings, complications, device mapping, electrophysiologic measures, audiologic outcomes, and speech and language measures were collected. RESULTS: Five children without NFII have received ABIs to date without permanent medical sequelae, although 2 children required treatment after surgery for temporary complications. All children wear their device daily, and the benefits of sound awareness have developed slowly. Intra-and postoperative electrophysiologic measures augmented surgical placement and device programming. The slow development of audition skills precipitated limited changes in speech production but had little impact on growth in spoken language. CONCLUSIONS: ABI surgery is safe in young children without NFII. Benefits from device use develop slowly and include sound awareness and the use of pattern and timing aspects of sound. These skills may augment progress in speech production but progress in language development is dependent upon visual communication. Further monitoring of this cohort is needed to better delineate the benefits of this intervention in this patient population.


Asunto(s)
Implantación Auditiva en el Tronco Encefálico , Implantes Auditivos de Tronco Encefálico , Sordera/cirugía , Desarrollo del Lenguaje , Implantación Auditiva en el Tronco Encefálico/efectos adversos , Encéfalo/diagnóstico por imagen , Preescolar , Sordera/fisiopatología , Sordera/rehabilitación , Electrofisiología , Potenciales Evocados Auditivos , Femenino , Humanos , Lactante , Trastornos del Desarrollo del Lenguaje , Masculino , Monitoreo Intraoperatorio , Estudios Prospectivos , Percepción del Habla , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda