Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Eur Heart J ; 35(37): 2530-40, 2014 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-24682843

RESUMEN

AIM: The aim of this study was to evaluate whether coronary artery disease (CAD) severity exerts a gradient of risk in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: A total of 445 patients with severe AS undergoing TAVI were included into a prospective registry between 2007 and 2012. The preoperative SYNTAX score (SS) was determined from baseline coronary angiograms. In case of revascularization prior to TAVI, residual SS (rSS) was also determined. Clinical outcomes were compared between patients without CAD (n = 158), patients with low SS (0-22, n = 207), and patients with high SS (SS > 22, n = 80). The pre-specified primary endpoint was the composite of cardiovascular death, stroke, or myocardial infarction (MI). At 1 year, CAD severity was associated with higher rates of the primary endpoint (no CAD: 12.5%, low SS: 16.1%, high SS: 29.6%; P = 0.016). This was driven by differences in cardiovascular mortality (no CAD: 8.6%, low SS: 13.6%, high SS: 20.4%; P = 0.029), whereas the risk of stroke (no CAD: 5.1%, low SS: 3.3%, high SS: 6.7%; P = 0.79) and MI (no CAD: 1.5%, low SS: 1.1%, high SS: 4.0%; P = 0.54) was similar across the three groups. Patients with high SS received less complete revascularization as indicated by a higher rSS (21.2 ± 12.0 vs. 4.0 ± 4.4, P < 0.001) compared with patients with low SS. High rSS tertile (> 14) was associated with higher rates of the primary endpoint at 1 year (no CAD:12.5%, low rSS: 16.5%, high rSS: 26.3%, P = 0.043). CONCLUSIONS: Severity of CAD appears to be associated with impaired clinical outcomes at 1 year after TAVI. Patients with SS > 22 receive less complete revascularization and have a higher risk of cardiovascular death, stroke, or MI than patients without CAD or low SS.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/patología , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/patología , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Infarto del Miocardio/etiología , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 83(7): 1135-43, 2014 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-22815250

RESUMEN

OBJECTIVE: The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS: A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS: At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION: This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.


Asunto(s)
Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Foramen Oval Permeable/cirugía , Dispositivo Oclusor Septal , Stents , Adolescente , Adulto , Anciano , Ecocardiografía , Femenino , Estudios de Seguimiento , Foramen Oval Permeable/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento , Adulto Joven
3.
Eur Heart J ; 34(44): 3437-50, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24096324

RESUMEN

AIMS: Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS: Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG: 2006 ± 586 vs. LEF-LG: 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG: 6.9 ± 1.9 vs. LEF-LG: 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG: 71.7% vs. LEF-LG: 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION: TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Análisis de Varianza , Válvula Aórtica , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Hipertensión Pulmonar/fisiopatología , Masculino , Falla de Prótesis , Estudios Retrospectivos , Volumen Sistólico/fisiología , Resultado del Tratamiento , Disfunción Ventricular Izquierda
4.
Eur Heart J ; 31(8): 984-91, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20038513

RESUMEN

AIMS: The purpose of the present analysis was to identify predictors of procedural success of percutaneous transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We prospectively assessed in-hospital outcome of patients undergoing TAVI at two institutions. We analysed clinical, morphological, and procedural parameters using univariate and multivariate regression models. Between 2005 and 2008, a total of 168 consecutive patients with symptomatic aortic valve stenosis underwent TAVI using the self-expanding CoreValve Revalving prosthesis. Patients (93%) were highly symptomatic with a New York Heart Association grade III/IV and a mean aortic valve area of 0.66 +/- 0.21 cm(2). Acute and in-hospital procedural success rates were 90.5 and 83.9%, respectively, with an in-hospital mortality, myocardial infarction, and stroke rate of 11.9, 1.8, and 3.6%, respectively. Predictors of in-hospital procedural success were type of access (OR 0.33, 95% CI 0.13-0.82, P = 0.017), prior coronary intervention (OR 5.3, 95% CI 1.20-23.41, P = 0.028) and pre-procedural Karnofsky index using univariate regression. Pre-procedural Karnofsky index emerged as the only independent predictor (OR 1.04, 95% CI 1.00-1.08, P = 0.032) in the multivariate analysis. CONCLUSION: Pre-procedural functional performance status predicts the in-hospital outcome after TAVI. Patients with a good functional status are likely to benefit more from TAVI than previously reported high-risk patients.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Stents , Resultado del Tratamiento , Adulto Joven
5.
Catheter Cardiovasc Interv ; 76(3): 431-9, 2010 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-20506410

RESUMEN

BACKGROUND: After trans-catheter aortic valve implantation (TAVI), the need for postinterventional pacemaker (PM) implantation can occur in as many as 10-50% of cases, but it is not yet clear, how this need can be predicted. The aim of this study was to assess the possible predictive factors of post TAVI PM implantation based on Computed Tomography (CT) measured aortic valve calcification and its distribution. METHODS: We prospectively analyzed 81 consecutive symptomatic patients with severe AS scheduled for TAVI using the CoreValve prosthesis (Medtronic, Minneapolis, USA). In all patients, a native and contrast-enhanced multislice cardiac CT was performed preinterventionally, estimating calcification load of the native valve cusps and of the adjacent outflow tract (so called "device landing zone", DLZ) by the Agatston Score (AgS). Objective, computer-evaluated, preprocedural ECG-analysis was performed with regards to pre-existing conduction abnormalities. Transthoracic echocardiography was performed pre and post TAVI. RESULTS: TAVI was successful in all cases. PM implantation was deemed necessary in altogether 32 patients, out of 67 without a PM pre-TAVI (32/67, 47%). Various parameters were tested as predictors of post TAVI PM in a multivariate logistic regression analysis model. Female sex (P = 0,005) and depressed EF (P = 0,023) showed a significant correlation. PM implantation correlated also to the DLZ calcification, as assessed by CT (P = 0,004). This model leads to an AUC (area under the ROC-receiver operator characteristics-curve) of 0.83. CONCLUSION: Calcium amount in the CoreValve DLZ in combination with clinical data could predict the need for post TAVI PM implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Arritmias Cardíacas/terapia , Calcinosis/diagnóstico por imagen , Cateterismo Cardíaco/instrumentación , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Calcinosis/complicaciones , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Electrocardiografía , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Modelos Logísticos , Masculino , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Volumen Sistólico
6.
Herz ; 34(2): 124-9, 2009 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-19370328

RESUMEN

Percutaneous aortic valve replacement is presently on its way to revolutionize the current treatment practice for patients with degenerative aortic valve stenosis. Two different techniques are available: the balloon-expandable Edwards valve prosthesis and the self-expanding CoreValve ReValving prosthesis. After an initial learning curve as well as device modifications, use of the current generations has a > 95% success rate with a low peri- and post-interventional complication rate. In this article, an overview on the current status of this technique will be provided.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Medición de Riesgo , Factores de Riesgo , Evaluación de la Tecnología Biomédica
7.
Circulation ; 116(7): 745-54, 2007 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-17664375

RESUMEN

BACKGROUND: The need for prolonged aspirin and thienopyridine therapy and the risk of stent thrombosis (ST) remain as drawbacks associated with drug-eluting stents. METHODS AND RESULTS: A prospective observational cohort study was conducted between June 2002 and January 2004 on 3021 patients consecutively and successfully treated in 5389 lesions with drug-eluting stents. Detailed patient information was collected on antiplatelet therapy. We analyzed the incidence of ST throughout the 18-month follow-up period and its relationship with thienopyridine therapy. ST occurred in 58 patients (1.9%) at 18 months. Forty-two patients (1.4%) experienced the event within 6 months of stent implantation. Acute myocardial infarction (fatal or nonfatal) occurred in 46 patients (79%) and death in 23 patients (39%) with ST. The median interval from discontinuation of thienopyridine therapy to ST was 13.5 days (interquartile range 5.2 to 25.7 days) for the first 6 months and 90 days (interquartile range 30 to 365 days) between 6 and 18 months. On multivariable analysis, the strongest predictor for ST within 6 months of stenting was discontinuation of thienopyridine therapy (hazard ratio, 13.74; 95% CI, 4.04 to 46.68; P<0.001). Thienopyridine discontinuation after 6 months did not predict the occurrence of ST (hazard ratio, 0.94; 95% CI, 0.30 to 2.98; P=0.92). CONCLUSIONS: Discontinuation of thienopyridine therapy was the major determinant of ST within the first 6 months, but insufficient information is available to determine whether there is benefit in continuing a thienopyridine beyond 6 months.


Asunto(s)
Inhibidores de Agregación Plaquetaria/uso terapéutico , Piridinas/uso terapéutico , Stents/efectos adversos , Trombosis/epidemiología , Anciano , Aspirina/uso terapéutico , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Paclitaxel/administración & dosificación , Paclitaxel/uso terapéutico , Sirolimus/administración & dosificación , Sirolimus/uso terapéutico , Trombosis/diagnóstico , Trombosis/etiología , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 71(5): 579-84, 2008 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-18360844

RESUMEN

OBJECTIVES AND BACKGROUND: Percutaneous aortic valve replacement is a new less-invasive alternative for high-risk surgical candidates with aortic stenosis. However, the clinical experience is still limited, and the currently available 'first-generation devices' revealed technical shortcomings, such as lack of repositionability and presence of paravalvular leakages. We report the first-in-man experience with the new self-expanding Lotus Valve prosthesis composed of a nitinol frame with implemented bovine pericardial leaflets which is designed to address these issues, being repositionable and covered by a flexible membrane to seal paravalvular gaps. We implanted this prosthesis in a 93-year old patient presenting with severe symptomatic aortic stenosis (valve area: 0.6 cm(2)). Surgical valve replacement had been declined due to comorbidities. METHODS AND RESULTS: We used a retrograde approach for insertion of the 21-French Lotus catheter loaded with the valve prosthesis via surgical cut-down to the external iliac artery. Positioning of the valve was guided by transesophageal echo and supra-aortic angiograms. The prosthesis was successfully inserted and deployed within the calcified native valve. Echocardiography immediately after device deployment showed a significant reduction of the transaortic mean pressure gradient (32 to 9 mmHg; final valve area 1.7 cm(2)) without evidence of residual aortic regurgitation. The postprocedural clinical status improved from NYHA-IV to NYHA-II. These results remained unchanged up to the 3 month follow-up. CONCLUSIONS: Successful percutaneous aortic valve replacement can be performed using the new self-expanding and repositionable Lotus valve for treatment of high-risk patients with aortic valve stenosis. Further studies are mandatory to assess device safety and efficacy in larger patient populations.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Pericardio/trasplante , Anciano de 80 o más Años , Aleaciones , Animales , Estenosis de la Válvula Aórtica/patología , Aortografía , Bovinos , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Proyectos Piloto , Diseño de Prótesis , Radiografía Intervencional , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
9.
Int J Med Sci ; 5(2): 50-61, 2008 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-18345283

RESUMEN

BACKGROUND: Resting electrocardiogram (ECG) shows limited sensitivity and specificity for the detection of coronary artery disease (CAD), where patients with a history of coronary revascularization may pose special challenges. Several methods exist to enhance sensitivity and specificity of resting ECG for diagnosis of CAD, but such methods are not better than a specialist's judgement. We compared a new computer-enhanced, resting ECG analysis device, 3DMP, to coronary angiography to evaluate the device's accuracy in detecting hemodynamically relevant CAD. METHODS: A convenience sample of 172 patients with a history of coronary revascularization scheduled for coronary angiography was evaluated with 3DMP before coronary angiography. 3DMP's sensitivity and specificity in detecting hemodynamically relevant coronary stenosis as diagnosed with coronary angiography were calculated as well as odds ratios for the 3DMP severity score and coronary artery disease risk factors. RESULTS: The 3DMP system accurately identified 50 of 55 patients as having hemodynamically relevant stenosis (sensitivity 90.9%, specificity 88.0%). Positive and negative predictive values for the identification of coronary stenosis as diagnosed in coronary angiograms were 62.7% and 97.8% respectively. Risk and demographic factors in a logistic regression model had a markedly lower predictive power for the presence of coronary stenosis in these patients than did 3DMP severity score (odds ratio 2.04 [0.74-5.62] vs. 73.57 [25.10-215.68]). A logistic regression combining severity score with risk and demographic factors did not add significantly to the prediction quality (odds ratio 80.00 [27.03-236.79]). CONCLUSIONS: 3DMP's computer-based, mathematically derived analysis of resting two-lead ECG data provides detection of hemodynamically relevant CAD in patients with a history of coronary revascularization with high sensitivity and specificity that appears to be at least as good as those reported for other resting and/or stress ECG methods currently used in clinical practice.


Asunto(s)
Angiografía Coronaria/normas , Puente de Arteria Coronaria/métodos , Estenosis Coronaria/diagnóstico , Diagnóstico por Computador , Electrocardiografía/métodos , Anciano , Área Bajo la Curva , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Estenosis Coronaria/patología , Femenino , Hemodinámica , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Valor Predictivo de las Pruebas , Curva ROC , Factores de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Procesamiento de Señales Asistido por Computador
10.
Circulation ; 114(15): 1616-24, 2006 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-17015786

RESUMEN

BACKGROUND: The morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve). METHODS AND RESULTS: Symptomatic high-risk patients with an aortic valve area <1 cm2 were considered for enrollment. CoreValve implantation was performed under general anesthesia with extracorporeal support using the retrograde approach. Clinical follow-up and transthoracic echocardiography were performed after the procedure and at days 15 and 30 after device implantation to evaluate short-term patient and device outcomes. A total of 25 patients with symptomatic aortic valve stenosis (mean gradient before implantation, 44.2+/-10.8 mm Hg) and multiple comorbidities (median logistic EuroScore, 11.0%) were enrolled. Device success and procedural success were achieved in 22 (88%) and 21 (84%) patients, respectively. Successful device implantation resulted in a marked reduction in the aortic valve gradients (mean gradient after implantation, 12.4+/-3.0 mm Hg; P<0.0001). The mean aortic regurgitation grade was unchanged. Major in-hospital cardiovascular and cerebral events occurred in 8 patients (32%), including mortality in 5 patients (20%). Among 18 patients with device success surviving to discharge, no adverse events occurred within 30 days after leaving the hospital. CONCLUSIONS: Percutaneous implantation of the self-expanding CoreValve aortic valve prosthesis in high-risk patients with aortic stenosis with or without aortic regurgitation is feasible and, when successful, results in marked hemodynamic and clinical improvement.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/fisiopatología , Clopidogrel , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica/fisiología , Humanos , Masculino , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Factores de Riesgo , Stents , Trombocitopenia/tratamiento farmacológico , Trombocitopenia/etiología , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico , Resultado del Tratamiento
11.
Am J Cardiol ; 99(12): 1691-7, 2007 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-17560877

RESUMEN

Percutaneous intervention for coronary bifurcation lesions has been associated with increased clinical complication rates compared with nonbifurcation lesions, primarily as a result of restenosis. Therefore, there is a need for new techniques. The purpose of this study was to evaluate a new drug-eluting stent and implantation technique for the treatment of de novo coronary bifurcation lesions. The Axxess Plus trial was a prospective multicenter single-arm study that enrolled 139 patients. Each patient received a self-expanding, conically shaped nickel-titanium Axxess Plus biolimus A9-eluting stent at the level of the carina. Depending on the lesion anatomy, additional nonstudy stents were placed distally if necessary. Clinical and angiographic follow-up were scheduled at 6 months after the procedure. The overall rate of target lesion revascularization was 7.5% at 6 months. A mean of 2.4 stents were implanted per patient; 51.2% of patients received a stent to the side branch, 29.4% received balloon angioplasty only, and 20.6% of side branches were not treated. In-stent late loss in the Axxess stents was 0.09 mm. Incidences of angiographic in-stent restenosis were 7.1% in the parent vessel stents and 9.2% in the group receiving stents in the side branch (7.9% excluding bare metal stents placed distal to the Axxess stent), compared with 25% for balloon angioplasty treatment and 12% for no treatment. Late stent thrombosis was observed in 3 cases, 2 of which were associated with confirmed premature cessation of antiplatelet therapy. In conclusion, the Axxess Plus conical stent effectively treats bifurcation lesions alone or in conjunction with other drug-eluting stents.


Asunto(s)
Antibióticos Antineoplásicos/uso terapéutico , Implantación de Prótesis Vascular/instrumentación , Vasos Coronarios/cirugía , Sirolimus/análogos & derivados , Stents , Anciano , Angiografía Coronaria , Estenosis Coronaria/cirugía , Vasos Coronarios/anatomía & histología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sirolimus/uso terapéutico
13.
Interact Cardiovasc Thorac Surg ; 25(2): 198-205, 2017 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-28486661

RESUMEN

OBJECTIVES: We report validation of OsiriX® -an image processing freeware-to measure multi-slice computed tomography-derived annulus diameters for preprocedural transcatheter aortic valve implantation planning. METHODS: A total of 137 patients (82 ± 6.5 years, 42.3% male, logistic EuroSCORE 24.1 ± 14.2%) with severe aortic stenosis at high surgical risk underwent transcatheter aortic valve implantation assessment: transoesophageal echocardiography, angiography and multi-slice computed tomography. Retrospectively, 3D multi-slice computed tomography reconstructions were generated using OsiriX and the reliability evaluated regarding inter- and intraobserver variability, intermodality correlation and estimation of the clinical impact on transcatheter aortic valve implantation sizing. RESULTS: Reliability of the novel OsiriX software was high with an interobserver mean difference of 0.6 ± 1.4 mm and intraclass correlation of absolute agreement of 0.84 (95% confidence interval 0.74-0.90). The intermodality accuracy between OsiriX measurements and conventional 2D computed tomography reconstructions, transoesophageal echocardiography and angiography revealed significantly larger sizing with OsiriX, with a mean difference to 2D computed tomography of 0.4 ± 2.2 mm, which would have changed valve sizing in 38% of patients. In 28%, a larger size would have been chosen, and this correlated highly with the occurrence of postoperative severe aortic regurgitation (P < 0.001). CONCLUSIONS: While OsiriX measurements are an accurate and reproducible assessment of the aortic annulus, there are distinct and clinically relevant differences in aortic annulus dimensions between OsiriX measurements and previously standard imaging modalities. Sizing with OsiriX resulted in a larger perimeter compared with conventional 2D imaging. Careful assessment of valve size will take into account multiple imaging modalities.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Imagenología Tridimensional/métodos , Tomografía Computarizada Multidetector/métodos , Programas Informáticos , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Periodo Preoperatorio , Curva ROC , Estudios Retrospectivos
14.
Expert Rev Med Devices ; 3(6): 731-41, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17280537

RESUMEN

Drug-eluting stent technology consisting of a bare metal stent, carrier coating, bioactive drug and delivery system, offers an almost infinite range of possible device configurations. A growing understanding of the mechanisms of restenosis allows for the design of synergistic functions within these components, thus providing a basis for new and improved products. The BioMatrix stent (Biosensors Interventional Technologies Pte Ltd., Singapore) elutes the new sirolimus derivative Biolimus A9 from a biodegradable polylactic acid polymer. Biolimus A9 possesses enhanced anti-inflammatory and antiproliferative activity with an improved pharmacokinetic profile. Permanent polymer-carrier-based platforms may be associated with inflammation, late thrombosis and restenosis. The BioMatrix, with its asymmetric and abluminal coating, releases Biolimus A9 into the vessel wall while the polylactic acid polymer is resorbed by surrounding tissues. Clinical studies have demonstrated the BioMatrix to be well tolerated and effective, and it has now become the subject of an aggressive clinical program.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/prevención & control , Portadores de Fármacos/administración & dosificación , Sistemas de Liberación de Medicamentos , Sirolimus/análogos & derivados , Stents , Animales , Materiales Biocompatibles Revestidos/química , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Ácido Láctico/química , Poliésteres , Polímeros/química , Ensayos Clínicos Controlados Aleatorios como Asunto , Sirolimus/administración & dosificación
15.
Circulation ; 107(1): 38-42, 2003 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-12515740

RESUMEN

BACKGROUND: The TAXUS NIRx stent (Boston Scientific Corp) provides local delivery of paclitaxel via a slow-release polymer coating. The TAXUS I trial was the first in-human experience evaluating safety and feasibility of the TAXUS NIRx stent system compared with bare NIR stents (control) (Boston Scientific Corp) for treatment of coronary lesions. METHODS AND RESULTS: The TAXUS I trial was a prospective, double-blind, three-center study randomizing 61 patients with de novo or restenotic lesions (< or =12 mm) to receive a TAXUS (n=31) versus control (n=30) stent (diameter 3.0 or 3.5 mm). Demographics, lesion characteristics, clinical outcomes were comparable between the groups. The 30-day major adverse cardiac event (MACE) rate was 0% in both groups (P=NS). No stent thromboses were reported at 1, 6, 9, or 12 months. At 12 months, the MACE rate was 3% (1 event) in the TAXUS group and 10% (4 events in 3 patients) in the control group (P=NS). Six-month angiographic restenosis rates were 0% for TAXUS versus 10% for control (P=NS) patients. There were significant improvements in minimal lumen diameter (2.60+/-0.49 versus 2.19+/-0.65 mm), diameter stenosis (13.56+/-11.77 versus 27.23+/-16.69), and late lumen loss (0.36+/-0.48 versus 0.71+/-0.48 mm) in the TAXUS group (all P<0.01). No evidence of edge restenosis was seen in either group. Intravascular ultrasound analysis showed significant improvements in normalized neointimal hyperplasia in the TAXUS (14.8 mm3) group compared with the control group (21.6 mm3) (P<0.05). CONCLUSIONS: In this feasibility trial, the TAXUS slow-release stent was well tolerated and showed promise for treatment of coronary lesions, with significant reductions in angiographic and intravascular ultrasound measures of restenosis.


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Reestenosis Coronaria/prevención & control , Paclitaxel/administración & dosificación , Stents , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/epidemiología , Trombosis Coronaria/epidemiología , Vasos Coronarios/diagnóstico por imagen , Demografía , Método Doble Ciego , Implantes de Medicamentos , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Paclitaxel/uso terapéutico , Stents/efectos adversos , Ultrasonografía
16.
Am J Cardiol ; 96(1): 79-82, 2005 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15979439

RESUMEN

Early results with polymer-based paclitaxel-eluting stents have shown significant improvements in the clinical and angiographic parameters of restenosis, as well as excellent safety outcomes. However, the duration of these beneficial effects is unknown. Therefore, the clinical outcomes of the TAXUS I study population were evaluated at 2- and 3-year follow-up. In TAXUS I, 61 patients with single, focal coronary lesions were randomly assigned to receive either a paclitaxel-eluting TAXUS stent (n = 31) or a bare metal control stent (n = 30). Low rates of composite major adverse cardiac events (MACEs) reported at 1-year follow-up (3.2% TAXUS vs 10.0% control) were maintained at 2 and 3 years, with no additional MACEs in either treatment group 1 year after implantation. The single target vessel revascularization in the TAXUS group was remote from the target lesion in contrast to 3 target lesion revascularizations in the control group.


Asunto(s)
Antineoplásicos Fitogénicos/administración & dosificación , Antineoplásicos Fitogénicos/uso terapéutico , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/terapia , Paclitaxel/administración & dosificación , Paclitaxel/uso terapéutico , Stents , Anciano , Antineoplásicos Fitogénicos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Polímeros/química , Resultado del Tratamiento
17.
Am J Cardiol ; 116(10): 1560-5, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26428025

RESUMEN

B-type natriuretic peptide (BNP) levels are elevated in patients with aortic stenosis (AS) and decrease acutely after replacement of the stenotic valve. The long-term prognostic value of BNP after transcatheter aortic valve implantation (TAVI) and the relative prognostic utility of single versus serial peri-interventional measurements of BNP and N-terminal prohormone BNP (NT-pro-BNP) are unknown. This study sought to determine the impact of BNP levels on long-term outcomes after TAVI and to compare the utility of BNP versus NT-pro-BNP measured before and after intervention. We analyzed 340 patients with severe AS and baseline pre-TAVI assessment of BNP. In 219 patients, BNP and NT-pro-BNP were measured serially before and after intervention. Clinical outcomes over 2 years were recorded. Patients with high baseline BNP (higher tertile ≥591 pg/ml) had increased risk of all-cause mortality (adjusted hazard ratio 3.16, 95% confidence interval 1.84 to 5.42; p <0.001) and cardiovascular death at 2 years (adjusted hazard ratio 3.37, 95% confidence interval 1.78 to 6.39; p <0.001). Outcomes were most unfavorable in patients with persistently high BNP before and after intervention. Comparing the 2 biomarkers, NT-pro-BNP levels measured after TAVI showed the highest prognostic discrimination for 2-year mortality (area under the curve 0.75; p <0.01). Baseline-to-discharge reduction, but not baseline levels of BNP, was related to New York Heart Association functional improvement. In conclusion, high preintervention BNP independently predicts 2-year outcomes after TAVI, particularly when elevated levels persist after the intervention. BNP and NT-pro-BNP and their serial periprocedural changes provide complementary prognostic information for symptomatic improvement and survival.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico , Biomarcadores/sangre , Femenino , Estudios de Seguimiento , Humanos , Masculino , Pronóstico , Precursores de Proteínas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo
18.
Heart ; 101(1): 30-6, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25163691

RESUMEN

OBJECTIVE: To assess long-term clinical outcomes of consecutive high-risk patients with severe aortic stenosis according to treatment allocation to transcatheter aortic valve implantation (TAVI), surgical aortic valve replacement (SAVR) or medical treatment (MT). METHODS: Patients with severe aortic stenosis were consecutively enrolled into a prospective single centre registry. RESULTS: Among 442 patients (median age 83 years, median STS-score 4.7) allocated to MT (n=78), SAVR (n=107), or TAVI (n=257) all-cause mortality amounted to 81%, 37% and 43% after a median duration of follow-up of 3.9 years (p<0.001). Rates of major adverse cerebro-cardiovascular events were lower in patients undergoing SAVR or TAVI as compared with MT (SAVR vs MT: HR 0.31, 95% CI 0.21 to 0.46) (TAVI vs MT: HR 0.34, 95% CI 0.25 to 0.46), with no significant difference between SAVR and TAVI (HR 0.88, 95% CI 0.62 to 1.25). Whereas SAVR (HR 0.39, 95% CI 0.24 to 0.61), TAVI (HR 0.37, 95% CI 0.26 to 0.52), and female gender (HR 0.72, 95% CI 0.53 to 0.99) were associated with improved survival, body mass index ≤20 kg/m(2) (HR 1.60, 95% CI 1.04 to 2.47), diabetes (HR 1.48, 95% CI 1.03 to 2.12), peripheral vascular disease (HR 2.01, 95% CI 1.44 to 2.81), atrial fibrillation (HR 1.74, 95% CI 1.28 to 2.37) and pulmonary hypertension (HR 1.43, 95% CI 1.03 to 2.00) were identified as independent predictors of mortality. CONCLUSIONS: Among high-risk patients with severe aortic stenosis, long-term clinical outcome through 5 years was comparable between patients allocated to SAVR or TAVI. In contrast, patients with MT had a dismal prognosis.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Fármacos Cardiovasculares/uso terapéutico , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Fármacos Cardiovasculares/efectos adversos , Trastornos Cerebrovasculares/etiología , Comorbilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Suiza , Factores de Tiempo , Resultado del Tratamiento
19.
Circ Cardiovasc Interv ; 8(2): e001895, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25657315

RESUMEN

BACKGROUND: Up to 1 in 6 patients undergoing transcatheter aortic valve implantation (TAVI) present with low-ejection fraction, low-gradient (LEF-LG) severe aortic stenosis and concomitant relevant mitral regurgitation (MR) is present in 30% to 55% of these patients. The effect of MR on clinical outcomes of LEF-LG patients undergoing TAVI is unknown. METHODS AND RESULTS: Of 606 consecutive patients undergoing TAVI, 113 (18.7%) patients with LEF-LG severe aortic stenosis (mean gradient ≤40 mm Hg, aortic valve area <1.0 cm(2), left ventricular ejection fraction <50%) were analyzed. LEF-LG patients were dichotomized into ≤mild MR (n=52) and ≥moderate MR (n=61). Primary end point was all-cause mortality at 1 year. No differences in mortality were observed at 30 days (P=0.76). At 1 year, LEF-LG patients with ≥moderate MR had an adjusted 3-fold higher rate of all-cause mortality (11.5% versus 38.1%; adjusted hazard ratio, 3.27 [95% confidence interval, 1.31-8.15]; P=0.011), as compared with LEF-LG patients with ≤mild MR. Mortality was mainly driven by cardiac death (adjusted hazard ratio, 4.62; P=0.005). As compared with LEF-LG patients with ≥moderate MR assigned to medical therapy, LEF-LG patients with ≥moderate MR undergoing TAVI had significantly lower all-cause mortality (hazard ratio, 0.38; 95% confidence interval, 0.019-0.75) at 1 year. CONCLUSIONS: Moderate or severe MR is a strong independent predictor of late mortality in LEF-LG patients undergoing TAVI. However, LEF-LG patients assigned to medical therapy have a dismal prognosis independent of MR severity suggesting that TAVI should not be withheld from symptomatic patients with LEF-LG severe aortic stenosis even in the presence of moderate or severe MR.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/complicaciones , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/terapia , Selección de Paciente , Modelos de Riesgos Proporcionales , Medición de Riesgo , Factores de Riesgo , Suiza , Factores de Tiempo , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 8(5): 704-17, 2015 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-25946444

RESUMEN

OBJECTIVES: This study compared clinical outcomes and revascularization strategies among patients presenting with low ejection fraction, low-gradient (LEF-LG) severe aortic stenosis (AS) according to the assigned treatment modality. BACKGROUND: The optimal treatment modality for patients with LEF-LG severe AS and concomitant coronary artery disease (CAD) requiring revascularization is unknown. METHODS: Of 1,551 patients, 204 with LEF-LG severe AS (aortic valve area <1.0 cm(2), ejection fraction <50%, and mean gradient <40 mm Hg) were allocated to medical therapy (MT) (n = 44), surgical aortic valve replacement (SAVR) (n = 52), or transcatheter aortic valve replacement (TAVR) (n = 108). CAD complexity was assessed using the SYNTAX score (SS) in 187 of 204 patients (92%). The primary endpoint was mortality at 1 year. RESULTS: LEF-LG severe AS patients undergoing SAVR were more likely to undergo complete revascularization (17 of 52, 35%) compared with TAVR (8 of 108, 8%) and MT (0 of 44, 0%) patients (p < 0.001). Compared with MT, both SAVR (adjusted hazard ratio [adj HR]: 0.16; 95% confidence interval [CI]: 0.07 to 0.38; p < 0.001) and TAVR (adj HR: 0.30; 95% CI: 0.18 to 0.52; p < 0.001) improved survival at 1 year. In TAVR and SAVR patients, CAD severity was associated with higher rates of cardiovascular death (no CAD: 12.2% vs. low SS [0 to 22], 15.3% vs. high SS [>22], 31.5%; p = 0.037) at 1 year. Compared with no CAD/complete revascularization, TAVR and SAVR patients undergoing incomplete revascularization had significantly higher 1-year cardiovascular death rates (adj HR: 2.80; 95% CI: 1.07 to 7.36; p = 0.037). CONCLUSIONS: Among LEF-LG severe AS patients, SAVR and TAVR improved survival compared with MT. CAD severity was associated with worse outcomes and incomplete revascularization predicted 1-year cardiovascular mortality among TAVR and SAVR patients.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Enfermedad de la Arteria Coronaria/terapia , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Revascularización Miocárdica/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Revascularización Miocárdica/efectos adversos , Revascularización Miocárdica/mortalidad , Modelos de Riesgos Proporcionales , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Suiza , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda