Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Radiol Prot ; 40(2): 381-392, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32045888

RESUMEN

Routine monitoring is an important element of any occupational radiation protection programme to be able to determine how effective this protection is in practice. As well as providing information on normal operational conditions and routine worker dose uptakes, these programmes are also required to be able to detect the occurrence of abnormal or unexpected exposures to radionuclides, where these risks are deemed to be present in the workplace. Various monitoring techniques and methods are available and can be applied to the direct monitoring of workers or of the workplace. For many of the less radio-toxic radionuclides simple monitoring programmes are often more than sufficient to demonstrate compliance with operational and regulatory controls; however, multiple programmes, operated in parallel, are often required for the more radio-toxic radionuclides-e.g. Plutonium and americium-to be able to provide assurance that the potential risks of exposure are reliably and adequately controlled. When a potential exposure event is detected then further investigations are instigated to confirm whether an intake has occurred and to estimate the resultant dose. This paper presents an empirical review of the records of all such investigations over an eighteen-year period at the Harwell site, Oxfordshire, UK. The purposes of this review were to determine the relative effectiveness of different monitoring methods in being able to detect potential exposure events; and how efficient each method was in detecting potential exposures which, following investigation, were confirmed as real intakes. The analyses revealed that routine faecal sampling provided the better performance characteristics in terms of combined effectiveness and efficiency; and that the ability to detect potential exposures (at levels of up to 6 mSv) in the absence of any routine monitoring programme was limited. There was a very low incidence of potential exposures being detected by more than one monitoring technique, which emphasises the importance of operating multiple monitoring methods in order to optimise the probability and confidence of detecting potential exposures.


Asunto(s)
Americio/análisis , Exposición Profesional/análisis , Monitoreo de Radiación/métodos , Contaminación Radiactiva del Aire/análisis , Humanos , Laboratorios , Plutonio , Dosis de Radiación , Protección Radiológica/métodos , Medición de Riesgo/métodos , Reino Unido
2.
Clin Radiol ; 71(8): 722-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27207375

RESUMEN

Computed tomography coronary angiography is increasingly used in imaging departments in the investigation of patients with chest pain and suspected coronary artery disease. Due to the routine use of heart rate controlling medication and the potential for very high radiation doses during these scans, there is a need for guidance on best practice for departments performing this examination, so the patient can be assured of a good quality scan and outcome in a safe environment. This article is a summary of the document on 'Standards of practice of computed tomography coronary angiography (CTCA) in adult patients' published by the Royal College of Radiologists (RCR) in December 2014.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/normas , Seguridad del Paciente/normas , Guías de Práctica Clínica como Asunto , Protección Radiológica/normas , Radiología/normas , Cardiología/normas , Humanos , Exposición a la Radiación/prevención & control , Exposición a la Radiación/normas , Reino Unido
3.
Clin Radiol ; 68(11): e570-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23838086

RESUMEN

AIM: To assess the effect of two iterative reconstruction algorithms (AIDR and AIDR3D) and individualized automatic tube current selection on radiation dose and image quality in computed tomography coronary angiography (CTCA). MATERIALS AND METHODS: In a single-centre cohort study, 942 patients underwent electrocardiogram-gated CTCA using a 320-multidetector CT system. Images from group 1 (n = 228) were reconstructed with a filtered back projection algorithm (Quantum Denoising Software, QDS+). Iterative reconstruction was used for group 2 (AIDR, n = 379) and group 3 (AIDR3D, n = 335). Tube current was selected based on body mass index (BMI) for groups 1 and 2, and selected automatically based on scout image attenuation for group 3. Subjective image quality was graded on a four-point scale (1 = excellent, 4 = non-diagnostic). RESULTS: There were no differences in age (p = 0.975), body mass index (p = 0.435), or heart rate (p = 0.746) between the groups. Image quality improved with iterative reconstruction and automatic tube current selection [1.3 (95% confidence intervals (CI): 1.2-1.4), 1.2 (1.1-1.2) and 1.1 (1-1.2) respectively; p < 0.001] and radiation dose decreased [274 (260-290), 242 (230-253) and 168 (156-180) mGy cm, respectively; p < 0.001]. CONCLUSION: The application of the latest iterative reconstruction algorithm and individualized automatic tube current selection can substantially reduce radiation dose whilst improving image quality in CTCA.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Algoritmos , Estudios de Cohortes , Medios de Contraste , Electrocardiografía/métodos , Femenino , Humanos , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
Clin Radiol ; 66(10): 940-4, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21724182

RESUMEN

AIM: To investigate the use of a weight-based volume of contrast media to optimize portal enhancement in patients undergoing abdominal computed tomography (CT). MATERIALS AND METHODS: Thirty-one patients were assessed to establish whether a relationship existed between their weight and the portal liver enhancement achieved. Three methods of estimating weight were evaluated to establish which was the most appropriate to use in clinical practice. One hundred patients were then examined using 100 ml contrast media and 100 further patients using a weight-based contrast volume as dictated by a look-up table. The enhancement achieved by each technique was assessed. RESULTS: A good correlation was shown between patient weight and contrast enhancement when a fixed volume of contrast media was used (r=-0.825, p<0.0001). Asking the patient was shown to be the most appropriate method for estimating their weight. The mean portal liver enhancement using the fixed dose and weight-adjusted dose were 110 HU (SD=25.1) and 108 HU (SD=11.9), respectively. Weight-adjusted dose brought 37% more patients into the "ideal" enhancement range of 100-125 HU. CONCLUSION: The use of a simple, practical, weight-based look-up table to decide contrast media volumes during portal phase liver CT can greatly reduce inter-patient variability compared to a fixed-volume technique.


Asunto(s)
Peso Corporal , Medios de Contraste/administración & dosificación , Hígado/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Intensificación de Imagen Radiográfica , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Inyecciones Intravenosas , Masculino , Intensificación de Imagen Radiográfica/métodos , Radiografía Abdominal/métodos , Radiografía Abdominal/normas , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
5.
Radiat Prot Dosimetry ; 185(2): 201-207, 2019 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-30668839

RESUMEN

The slow dissolution rate of material deposited in the lung plays a key role in determining the eventual radiation dose received by the lung. It is therefore of great importance to establish a reliable value for this parameter, to incorporate into the latest Mayak Worker Dosimetry System (MWDS-2016). Disparate values have been obtained for the slow dissolution rate of plutonium nitrate. A volunteer study performed by Public Health England (PHE) and an analysis of United States Transuranium and Uranium Registries (USTUR) case 0269 have yielded slow dissolution rates in the region of 10-40 × 10-4 d-1. However, autopsies performed on 20 Mayak workers, exposed predominantly to nitrates, have resulted in estimates of slow dissolution rates of around 2.4 × 10-4 d-1. Three hypotheses have been proposed to explain this discrepancy: (1) a slower dissolution rate in the interstitium, (2) a third exponential component in the dissolution function and (3) a small component of oxide in the aerosol to which Mayak 'nitrate' workers were exposed. This paper describes tests of these competing hypotheses. Bayesian methods have been applied to the following datasets: PHE volunteer data; Beagle dog data; USTUR cases and Mayak worker data. It is concluded that a mixture of oxide and nitrate material, with the oxide forming ~14% of the intake, best describes the Mayak dissolution rate, without introducing values for other parameters which conflict with other studies.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Aorta Torácica/metabolismo , Pulmón/metabolismo , Ganglios Linfáticos/metabolismo , Nitratos/farmacocinética , Exposición Profesional/análisis , Plutonio/farmacocinética , Animales , Aorta Torácica/efectos de la radiación , Teorema de Bayes , Perros , Inglaterra , Humanos , Pulmón/efectos de la radiación , Ganglios Linfáticos/efectos de la radiación , Masculino , Nitratos/análisis , Guerra Nuclear , Especificidad de Órganos , Plutonio/análisis , Dosis de Radiación , Distribución Tisular
6.
Radiat Prot Dosimetry ; 124(3): 274-9, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17725980

RESUMEN

The measurement of air samples may be used to assess risks of internal exposures, either by the use of workplace static air samplers (SAS) or personal air samplers (PAS). These measurements need to incorporate information on the physical and chemical nature of the aerosol, and the relationship between the sampled and potentially breathed aerosol. This paper provides an overview of methods, which are typically used in occupational dosimetry to determine these characteristics. A specific practical example is provided to illustrate how SAS are used to determine that potential personal doses are less than 1 mSv per year, and therefore do not require individual monitoring. The paper also discusses the nature and potential impact of the uncertainties associated with PAS monitoring, and how this is managed in practice.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Monitoreo de Radiación/métodos , Monitoreo del Ambiente/instrumentación , Humanos , Lugar de Trabajo
7.
Radiat Prot Dosimetry ; 127(1-4): 563-8, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17634206

RESUMEN

Intakes and doses arising from exposure to actinides must be reconstructed from historical bioassay data for the purposes of worker compensation and for epidemiology studies. The usual default assumption is that a series of urine activities is the result of a constant chronic intake. In reality, the urine activities will most likely arise from a random sequence of discrete intakes. In order to investigate the accuracy of the constant chronic assumption, we have created virtual urine datasets using Monte Carlo modelling and these were used as input to the code IMBA(1). Comparisons of estimated intakes with those used as input allow the uncertainties in the procedure to be estimated. The effects of incorrect assumptions about the scattering factors, activity median aerodynamic diameter (AMAD) and solubility can also be examined. The results show that the constant chronic assumptions leads to remarkably reliable estimates of intake, even for datasets generated by just a few intakes per year. The estimate of intake is fairly robust against mis-assignment of scattering factor and AMAD. However, as is well-known, the correct assignment of solubility is crucial in obtaining reliable estimates of intake and dose.


Asunto(s)
Elementos de Series Actinoides/farmacocinética , Elementos de Series Actinoides/orina , Bioensayo/métodos , Modelos Biológicos , Material Particulado/análisis , Material Particulado/farmacocinética , Radiometría/métodos , Administración por Inhalación , Administración Oral , Aerosoles/farmacocinética , Simulación por Computador , Interpretación Estadística de Datos , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Radiat Prot Dosimetry ; 121(4): 425-8, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16702238

RESUMEN

A worker provided a routine faecal sample for plutonium and americium analysis. In the course of this analysis 500 mBq of (228)Th was discovered. There seemed no credible occupational route for intake of thorium. Further investigation revealed that the worker consumed approximately 25 g d(-1) of nuts, including Brazil nuts. A sample of these nuts was analysed and found to contain activities of (228)Th in sufficient quantity to account for the faecal activity. However, follow-up urine samples taken from the worker showed 0.6-0.7 mBq of (228)Th. The intake of (228)Th via nuts is insufficient to account for this activity in urine. However, it is likely that the intake of (228)Th was accompanied by similar activity of the parent (228)Ra, and biokinetic calculations show that decay of (228)Ra in vivo would produce sufficient (228)Th to account for the observed urine activity.


Asunto(s)
Bertholletia/química , Ingestión de Alimentos , Heces/química , Contaminación Radiactiva de Alimentos/análisis , Torio/orina , Adulto , Carga Corporal (Radioterapia) , Humanos , Masculino , Tasa de Depuración Metabólica , Efectividad Biológica Relativa , Torio/análisis
9.
Br J Radiol ; 71(850): 1018-20, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10211060

RESUMEN

The aim of this study was to determine the upper limit of the normal main pulmonary artery diameter using a modern CT system. This was measured at the level of the pulmonary artery bifurcation in 100 normal subjects using unenhanced contiguous 10 mm CT slices viewed at fixed mediastinal window settings (400/20). These normal subjects were then compared with similar unenhanced 10 mm images from 12 patients with proven pulmonary arterial hypertension (mean pulmonary artery pressure > 20 mmHg). The main pulmonary artery diameter in normal subjects was 2.72 cm (SD = 0.3). Main pulmonary artery diameter in patients with pulmonary arterial hypertension was significantly greater (p < 0.01) at 3.47 cm (SD = 0.33). A pulmonary artery diameter of 3.32 cm (main pulmonary artery diameter + 2 SD) had a 58% sensitivity and 95% specificity for the presence of pulmonary arterial hypertension. It is concluded that, using unenhanced axial 10 mm CT sections, the upper limit of normal main pulmonary artery diameter is 3.32 cm. Pulmonary arterial hypertension should be considered in patients with values above this level.


Asunto(s)
Hipertensión Pulmonar/diagnóstico por imagen , Arteria Pulmonar/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Análisis por Apareamiento , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad
10.
Br J Radiol ; 71(849): 923-5, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10195005

RESUMEN

Previous studies have suggested that the upper limit of the thinnest portion of the pericardium is 3-4 mm using 10 mm CT slices. However, these studies suffered from small sample sizes, long data acquisition times and unconventional viewing parameters. We have measured the width of the thinnest portion of the normal pericardium using 10 mm (100 patients) and 1 mm (100 patients) high resolution CT (HRCT) slices with modern CT equipment and fixed mediastinal window settings (400/20). The pericardium was identified in all patients and was best seen anterior to the heart. The pericardium is exceptionally well seen using 1 mm HRCT slices and this may be the optimal technique for visualization of the pericardium. The upper limit of the thinnest portion of the normal pericardium (mean value + 2 SD) was 1.2 mm (10 mm CT slices) and 0.7 mm (1 mm HRCT slices). These values are substantially lower than those previously reported and in line with anatomical findings.


Asunto(s)
Pericardio/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardio/anatomía & histología , Valores de Referencia
11.
Br J Radiol ; 73(871): 715-9, 2000 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11089461

RESUMEN

The aim of the study was to determine optimal parameters for demonstrating sublobar bronchi on spiral CT. Measurements were obtained from five parallel polyethylene tubes embedded in foam matrix with similar radiographic characteristics to segmental and subsegmental bronchi and to lung parenchyma, respectively. Collimation widths of 1.5, 2, 3 and 4 mm were used, with a pitch of 1 or 1.5 and a reconstruction interval of 1 mm or 2 mm. Various slice planes were used. Images acquired orthogonally were viewed normally. Images acquired in planes oblique or parallel to the long axes of the tubes were reformatted into a plane orthogonal to the long axes of the tubes to be comparable with the directly acquired orthogonal images. Tube diameters were measured at lung window settings (L, -400; W, 1300) and compared with known true inner and outer tube diameters. Measurements from images acquired orthogonal to the tube long axes were accurate regardless of slice thickness. Images acquired obliquely or parallel only produced accurate measurements at the lowest slice thickness (1.5 mm). Pitch and reconstruction interval had no effect on measurement error in any scan plane. It is concluded that a slice thickness of 1.5 mm or less, with a pitch of 1.5, should be used when acquiring images at angles other than orthogonal to the long axes of experimental tubes equivalent to the segmental and subsegmental bronchi. It is suggested that similar parameters should be used in vivo and that the examination should be targeted to the area of the bronchial tree in question to reduce patient dose and length of breath-hold.


Asunto(s)
Broncografía/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Modelos Anatómicos , Tomografía Computarizada por Rayos X/instrumentación
12.
Radiat Prot Dosimetry ; 105(1-4): 369-73, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14526989

RESUMEN

A worker inhaled 241AmO2 powder. Air sampling showed low activities but a nose blow revealed 92 Bq. Results from faecal sampling and lung and whole-body monitoring indicated an intake of about 200 Bq, but urine sampling, though commencing only 1 d after intake, showed below-threshold activities (< 0.2 mBq). This conflicts with predictions based on the ICRP Publication 67 biokinetic model for americium and the ICRP Publication 66 model for the human respiratory tract, if default lung parameters are used.


Asunto(s)
Americio/análisis , Americio/farmacocinética , Heces/química , Pulmón/metabolismo , Modelos Biológicos , Exposición Profesional/análisis , Radiometría/métodos , Contaminantes Radiactivos del Aire/análisis , Contaminantes Radiactivos del Aire/farmacocinética , Contaminantes Radiactivos del Aire/orina , Americio/orina , Simulación por Computador , Humanos , Exposición por Inhalación/análisis , Mucosa Nasal/metabolismo , Polvos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Radiat Prot Dosimetry ; 162(3): 306-15, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24191121

RESUMEN

In Bayesian inference, the initial knowledge regarding the value of a parameter, before additional data are considered, is represented as a prior probability distribution. This paper describes the derivation of a prior distribution of intake that was used for the Bayesian analysis of plutonium and uranium worker doses in a recent epidemiology study. The chosen distribution is log-normal with a geometric standard deviation of 6 and a median value that is derived for each worker based on the duration of the work history and the number of reported acute intakes. The median value is a function of the work history and a constant related to activity in air concentration, M, which is derived separately for uranium and plutonium. The value of M is based primarily on measurements of plutonium and uranium in air derived from historical personal air sampler (PAS) data. However, there is significant uncertainty on the value of M that results from paucity of PAS data and from extrapolating these measurements to actual intakes. This paper compares posterior and prior distributions of intake and investigates the sensitivity of the Bayesian analyses to the assumed value of M. It is found that varying M by a factor of 10 results in a much smaller factor of 2 variation in mean intake and lung dose for both plutonium and uranium. It is concluded that if a log-normal distribution is considered to adequately represent worker intakes, then the Bayesian posterior distribution of dose is relatively insensitive to the value assumed of M.


Asunto(s)
Teorema de Bayes , Pulmón/efectos de la radiación , Exposición Profesional/análisis , Plutonio/análisis , Uranio/análisis , Estudios de Cohortes , Simulación por Computador , Estudios Epidemiológicos , Humanos , Modelos Biológicos , Modelos Estadísticos , Dosis de Radiación , Urinálisis
15.
Radiat Prot Dosimetry ; 156(2): 131-40, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23528329

RESUMEN

In a recent epidemiological study, Bayesian estimates of lung doses were calculated in order to determine a possible association between lung dose and lung cancer incidence resulting from occupational exposures to uranium. These calculations, which produce probability distributions of doses, used the human respiratory tract model (HRTM) published by the International Commission on Radiological Protection (ICRP) with a revised particle transport clearance model. In addition to the Bayesian analyses, point estimates (PEs) of doses were also provided for that study using the existing HRTM as it is described in ICRP Publication 66. The PEs are to be used in a preliminary analysis of risk. To explain the differences between the PEs and Bayesian analysis, in this paper the methodology was applied to former UK nuclear workers who constituted a subset of the study cohort. The resulting probability distributions of lung doses calculated using the Bayesian methodology were compared with the PEs obtained for each worker. Mean posterior lung doses were on average 8-fold higher than PEs and the uncertainties on doses varied over a wide range, being greater than two orders of magnitude for some lung tissues. It is shown that it is the prior distributions of the parameters describing absorption from the lungs to blood that are responsible for the large difference between posterior mean doses and PEs. Furthermore, it is the large prior uncertainties on these parameters that are mainly responsible for the large uncertainties on lung doses. It is concluded that accurate determination of the chemical form of inhaled uranium, as well as the absorption parameter values for these materials, is important for obtaining unbiased estimates of lung doses from occupational exposures to uranium for epidemiological studies. Finally, it should be noted that the inferences regarding the PEs described here apply only to the assessments of cases provided for the epidemiological study, where central estimates of dose were sought. Approved dosimetry service assessments of exposures are unlikely to yield significant underestimates, as pessimistic assumptions of lung solubility would almost always be used.


Asunto(s)
Teorema de Bayes , Pulmón/efectos de la radiación , Exposición Profesional/efectos adversos , Uranio/efectos adversos , Simulación por Computador , Humanos , Exposición Profesional/análisis , Dosis de Radiación , Radiometría , Incertidumbre , Uranio/administración & dosificación , Uranio/análisis
16.
Radiat Prot Dosimetry ; 151(2): 224-36, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22355169

RESUMEN

Estimating uncertainties on doses from bioassay data is of interest in epidemiology studies that estimate cancer risk from occupational exposures to radionuclides. Bayesian methods provide a logical framework to calculate these uncertainties. However, occupational exposures often consist of many intakes, and this can make the Bayesian calculation computationally intractable. This paper describes a novel strategy for increasing the computational speed of the calculation by simplifying the intake pattern to a single composite intake, termed as complex intake regime (CIR). In order to assess whether this approximation is accurate and fast enough for practical purposes, the method is implemented by the Weighted Likelihood Monte Carlo Sampling (WeLMoS) method and evaluated by comparing its performance with a Markov Chain Monte Carlo (MCMC) method. The MCMC method gives the full solution (all intakes are independent), but is very computationally intensive to apply routinely. Posterior distributions of model parameter values, intakes and doses are calculated for a representative sample of plutonium workers from the United Kingdom Atomic Energy cohort using the WeLMoS method with the CIR and the MCMC method. The distributions are in good agreement: posterior means and Q(0.025) and Q(0.975) quantiles are typically within 20 %. Furthermore, the WeLMoS method using the CIR converges quickly: a typical case history takes around 10-20 min on a fast workstation, whereas the MCMC method took around 12-72 hr. The advantages and disadvantages of the method are discussed.


Asunto(s)
Teorema de Bayes , Pulmón/efectos de la radiación , Método de Montecarlo , Exposición Profesional , Dosis de Radiación , Algoritmos , Simulación por Computador , Humanos , Exposición por Inhalación , Cadenas de Markov , Plutonio/administración & dosificación , Incertidumbre
17.
Radiat Prot Dosimetry ; 144(1-4): 627-31, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21123242

RESUMEN

Lung solubility is the key parameter in determining intakes and doses from inhalation of airborne contamination. However, information on lung solubility can be difficult to acquire, particularly for the historical exposures that are of relevance to lifetime-dose reconstruction. In this study, an empirical approach has been made in which over 200 dose assessments, mainly for Pu and Am, from the period 1986 to 2005 were re-evaluated and the solubility mix required for the best fit to the data was determined. The average of these solubility mixtures for any building or facility can be used as the default solubility for retrospective dose assessments for that facility. Results are presented for a radiochemistry facility, a materials development facility and a waste-storage/handling building at Harwell. The latter two areas are characterised by aerosols that are predominantly insoluble (type S), whereas the radiochemistry facility has a heterogeneous mixture of insoluble and soluble aerosols. The implications of these results for dose reconstruction are discussed in the paper.


Asunto(s)
Pulmón/efectos de la radiación , Exposición Profesional/prevención & control , Monitoreo de Radiación/instrumentación , Protección Radiológica/instrumentación , Aerosoles , Americio/análisis , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Heces , Humanos , Exposición por Inhalación , Plutonio/análisis , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Radioquímica/métodos , Reproducibilidad de los Resultados , Programas Informáticos , Solubilidad , Orina
18.
Arch Dis Child ; 81(2): 172-3, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10490531

RESUMEN

PURPOSE: Comparison of bone age assessed using either the "atlas matching" method of Greulich and Pyle or the "point scoring system" of Tanner and Whitehouse (TW2). MATERIALS AND METHODS: 362 consecutive "bone age" radiographs of the left hand and distal radius performed in a large provincial teaching hospital. Data were analysed using the "method comparison" statistical technique. Ten per cent of the radiographs were re-analysed to assess intra-observer variation. RESULTS: The 95% confidence interval for the difference between the two methods was 2.28 to -1.52 years. Intra-observer variation was greater for the Greulich and Pyle method than for the TW2 method (95% confidence limit, -2.46 to 2.18 v -1.41 to 1.43). CONCLUSION: The two methods of bone age assessment as used in clinical practice do not give equivalent estimates of bone age and we suggest that one method only (preferably the TW2) should be used when performing serial measurements on an individual patient.


Asunto(s)
Determinación de la Edad por el Esqueleto/métodos , Huesos/diagnóstico por imagen , Adolescente , Niño , Preescolar , Intervalos de Confianza , Humanos , Lactante , Variaciones Dependientes del Observador , Sensibilidad y Especificidad
19.
J Physiol ; 411: 63-70, 1989 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-2614738

RESUMEN

1. Changes in heart rate and blood pressure were observed, in nine healthy subjects, during and after voluntary and electrically evoked isometric contractions of the triceps surae under conditions of local circulatory arrest. 2. The progressive increases in heart rate and blood pressure seen during 2 min voluntary and evoked contractions at 30% of maximal voluntary contraction were not significantly different in the two conditions. On cessation of contraction but with circulatory arrest maintained, heart rate fell to control levels while blood pressure fell to a similar though still significantly elevated level in both conditions. Elevated blood pressure was maintained for 2 min until the circulatory occlusion was removed; however it was maintained at a significantly higher level for the last 60-90 s of occlusion following electrically evoked contractions compared to voluntary contraction. 3. Comparison of the responses to voluntary and involuntary electrically evoked contractions suggest that 'central command' is not necessary for the initial increases in heart rate and blood pressure to occur. In addition the removal of central command on cessation of contraction need not account for the return of heart rate to control levels or the drop in blood pressure at that time. Maintained blood pressure elevation during circulatory occlusion would seem to be due to the trapping of chemical substances within the muscle interstitium.


Asunto(s)
Presión Sanguínea , Frecuencia Cardíaca , Contracción Isométrica , Pierna/fisiología , Contracción Muscular , Adulto , Constricción , Femenino , Humanos , Pierna/irrigación sanguínea , Masculino
20.
Ann Occup Hyg ; 34(1): 35-44, 1990 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-2327688

RESUMEN

In order to provide information to assist in the design and planning of workplace air-sampling facilities, we have studied the variations in time and space of aerosol concentrations in a small room containing a glove-box and a heated phantom. Aerosol concentrations are reduced by factors of 10(2)-10(3) between the source and the phantom and walls of the room. Time-series plots of concentration show large departures from mean concentrations and fluctuations measured at the mouth and chest of the phantom are frequently uncorrelated. Both the average concentration around the phantom and the fluctuations in concentration tend to increase when the phantom is heated.


Asunto(s)
Aerosoles/análisis , Contaminantes Ocupacionales del Aire/análisis , Contaminantes Radiactivos del Aire/análisis , Contaminantes Atmosféricos/análisis , Movimientos del Aire , Temperatura Corporal , Humanos , Maniquíes , Procesamiento de Señales Asistido por Computador , Ventilación
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda