Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Chromatogr A ; 1533: 127-135, 2018 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-29249537

RESUMEN

We prepared a series of planar titanium microfluidic (µLC) columns, each 100 mm long, with 0.15, 0.3 and 0.5 mm i.d.'s. The microfluidic columns were packed with 1.8 µm C18 sorbent and tested under isocratic and gradient conditions. The efficiency and peak capacity of these devices were monitored using a micro LC instrument with minimal extra column dispersion. Columns with serpentine channels were shown to perform worse than those with straight channels. The loss of efficiency and peak capacity was more prominent for wider i.d. columns, presumably due to on-column band broadening imparted by the so-called "race-track" effect. The loss of chromatographic performance was partially mitigated by tapering the turns (reduction in i.d. through the curved region). While good performance was obtained for 0.15 mm i.d. devices even without turn tapering, the performance of 0.3 mm i.d. columns could be brought on par with capillary LC devices by tapering down to 2/3 of the nominal channel width in the turn regions. The loss of performance was not fully compensated for in 0.5 mm devices even when tapering was employed; 30% loss in efficiency and 10% loss in peak capacity was observed. The experimental data for various devices were compared using the expected theoretical relationship between peak capacity Pc and efficiency N; (Pc-1) = N0.5 × const. While straight µLC columns showed the expected behavior, the devices with serpentine channels did not adhere to the plot. The results suggest that the loss of efficiency due to the turns is more pronounced than the corresponding loss of peak capacity.


Asunto(s)
Técnicas de Química Analítica/instrumentación , Técnicas de Química Analítica/métodos , Cromatografía Liquida/instrumentación , Dispositivos Laboratorio en un Chip/normas , Microfluídica/instrumentación , Titanio/química
2.
Nat Biomed Eng ; 2(3): 151-157, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-31015714

RESUMEN

The advancement of point-of-care diagnostics and the decentralization of healthcare have created a need for the simple, safe, standardized and painless collection of blood specimens. Here, we describe the design and implementation of a capillary blood-collection device that is more convenient and less painful than a fingerstick and venepuncture, and collects 100 µl of blood. The technology integrates into a compact, self-contained device an array of solid microneedles, a high-velocity insertion mechanism, stored vacuum, and a microfluidic system containing lithium heparin anticoagulant. The use of the device requires minimal training, as blood collection is initiated by the single push of a button. In a clinical study involving 144 participants, haemoglobin A1c measurements from device-collected samples and from venous blood samples were equivalent, and the pain associated with the device was significantly less than that associated with venepuncture. The device, which has received premarket clearance by the US Food and Drug Administration, should help improve access to healthcare, and support healthcare decentralization.


Asunto(s)
Recolección de Muestras de Sangre , Agujas , Recolección de Muestras de Sangre/instrumentación , Recolección de Muestras de Sangre/métodos , Diseño de Equipo , Humanos , Sistemas de Atención de Punto
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda