Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Rhinology ; 59(3): 292-300, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315021

RESUMEN

BACKGROUND: Chronic rhinosinusitis (CRS) and chronic otitis media (COM) share pathophysiological mechanisms such as bacterial infection, biofilm, and persistence of the obstruction state of ventilation routes. However, only a few studies have investigated the relationship between these two diseases nationwide and in the general population. The purpose of this study was to determine whether the incidence of COM in patients with CRS differed from that of a matched control from the national health screening cohort. METHODS: Data from the Korean Health Insurance Review and Assessment Service-National Patient Samples were collected from 2002 to 2015. Participants who were treated ≥ ≥ ≥2 times and underwent head and neck computed tomography evaluation were selected. A 1:4 matched CRS group (n=8,057) and a control group (n=32,228) were selected. The control group included participants who were never treated with the ICD-10 code J32 from 2002 to 2015. The CRS group included CRS patients with/without nasal polyps. RESULTS: The incidence of COM was significantly higher in the CRS group than in the control group. In a subgroup analysis, the incidence of COM in all age groups and in men and women was significantly higher in the CRS group than in the control group. More, CRS increased the risk of COM. CONCLUSIONS: A significant association was observed between CRS and COM. This indicates that CRS patients have a high risk of developing COM.


Asunto(s)
Pólipos Nasales , Otitis Media , Rinitis , Sinusitis , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Otitis Media/complicaciones , Otitis Media/epidemiología , Rinitis/epidemiología , Sinusitis/epidemiología
2.
Int Endod J ; 49(11): 1020-1029, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26537746

RESUMEN

AIM: To evaluate the neurosensory outcome of management of damaged inferior alveolar nerves caused by endodontic overfilling and to assess the efficacy of delayed surgical intervention. METHODOLOGY: Nine patients who underwent surgical removal of extruded endodontic material were included. All patients were evaluated for neurosensory function using a set of standardized tests. The outcome of surgical intervention was evaluated through patient interview and quantitative statistical analysis. RESULTS: Surgical procedures included foreign body removal, microsurgical external/internal decompression, excision of neuroma followed by nerve repair, and excision of damaged nerve segment with interpositional nerve graft. Seven of the nine patients had significant improvement according to the follow-up neurosensory assessment. Four patients reported significant improvement, three patients reported mild improvement and two patients reported no appreciable improvement in the Visual Analog Scale (VAS). Two patients who reported no appreciable improvement in VAS also did not achieve FSR. In these patients, calcium hydroxide was spread widely along the IAN and a surgical approach was obtained via sagittal spit osteotomy. The mean time to reach FSR was 222.7 (±41.8) days with a range of 106-397 days. In the early repair group who received surgery within 60 days, three out of five patients achieved FSR in a mean time of 198.0 (±76.2) days. The mean time to FSR in all four subjects who received surgical attention over 60 days after injury was 241.3 (±139.8) days with a range of 106-397 days. As all four cases in the late repair group with limited amount of nerve injury achieved FSR, only 3 of 5 early repair cases with wide-spread injury achieved a similar outcome. CONCLUSION: The results of this case series confirmed the notion that surgical management of the inferior alveolar nerve is effective in the treatment of nerve injuries caused by endodontic extrusion of calcium hydroxide paste. Delayed surgical repair of the inferior alveolar nerve can be indicated and helpful for the neurosensory recovery of damaged IAN, however, the surgical management was less effective in case of widespread nerve injuries.


Asunto(s)
Hidróxido de Calcio , Nervio Mandibular/cirugía , Materiales de Obturación del Conducto Radicular/efectos adversos , Obturación del Conducto Radicular/efectos adversos , Traumatismos del Nervio Trigémino/cirugía , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Nervio Mandibular/diagnóstico por imagen , Nervio Mandibular/patología , Persona de Mediana Edad , Parestesia/etiología , Parestesia/cirugía , Radiografía Dental , Umbral Sensorial , Diente no Vital/patología , Traumatismos del Nervio Trigémino/etiología , Adulto Joven
3.
Genet Mol Res ; 14(3): 9667-74, 2015 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-26345899

RESUMEN

Alopecia areata (AA) is a common disease, which causes hair loss in humans. AA has a genetically complex inheritance. This study investigated the possible correlations between single nucleotide polymorphisms (SNPs) in the promoter regions of the chemokine (C-X-C motif) ligand 1 (melanoma growth stimulating activity, alpha) (CXCL1) and chemokine (C-X-C motif) ligand 2 (CXCL2) genes and the development of AA in the Korean population. Two hundred and thirty-five AA patients and 240 control subjects were recruited. The specific SNPs occurring in the promoter regions of the CXCL1 and CXCL2 genes (rs3117604, -429C/T and rs3806792, -264T/C, respectively) were genotyped. All data obtained was evaluated using the SNPStats, SPSS 18.0, and the Haploview v.4.2 software platforms. The Odd's ratios (OR), 95% confidence intervals (CI), and P values were calculated using multiple logistic regression models. Analyses of the genetic sequences obtained revealed a significant correlation between the two SNPs and the development of AA (rs3117604, P = 0.0009 in co-dominant model 1, P = 0.01 in co-dominant model 2, P = 0.004 in the dominant model, P = 0.005 in the log-additive model, P = 0.012 in allele distribution; rs3806792, P = 0.036 in co-dominant model 2, P = 0.0046 in the log-additive model). The TT and CC haplotypes were also observed to show a significant association with increased risk of AA (TT haplotype, P = 0.0018; CC haplotype, P = 0.0349). Our data suggests that the CXCL1 and CXCL2 genes may be associated with AA susceptibility.


Asunto(s)
Alopecia Areata/genética , Quimiocina CXCL1/genética , Quimiocina CXCL2/genética , Predisposición Genética a la Enfermedad , Polimorfismo de Nucleótido Simple , Regiones Promotoras Genéticas , Adolescente , Adulto , Alelos , Alopecia Areata/diagnóstico , Alopecia Areata/epidemiología , Estudios de Casos y Controles , Femenino , Frecuencia de los Genes , Estudios de Asociación Genética , Genotipo , Haplotipos , Humanos , Masculino , Oportunidad Relativa , República de Corea/epidemiología , Riesgo , Adulto Joven
4.
Radiat Prot Dosimetry ; 199(15-16): 1958-1962, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819298

RESUMEN

We present comprehensive Monte Carlo simulations for the neutron response of the multi-element microdosimetric detector based on THick Gas Electron Multiplier (THGEM). Simulations were carried out using the MCNP6.2 code to calculate the deposited energy spectrum in the gaseous sensitive volumes for three different configurations, 7 × 3, 19 × 5, 37 × 7 that occupy a cylindrical volume of 5-cm diameter by 5-cm length. The energy response was computed from 10 keV to 2 MeV. The response variation was investigated between sensitive volumes as well as between layers. The simulated energy response showed a good agreement against the evaluated fluence-to-kerma conversion coefficients in the energy region 10-100 keV, whereas discrepancies were observed in the region above 250 keV. The angular response simulations showed a variation of less than 10%.


Asunto(s)
Electrones , Radiometría , Método de Montecarlo , Neutrones , Simulación por Computador , Gases
5.
Appl Radiat Isot ; 177: 109902, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34481317

RESUMEN

In this article, we present a methodology for performing eye lens dosimetry in CANDU nuclear power plants using an existing and highly accurate Harshaw 4-element TLD-700 dosemeter. This dosemeter, which has been specially designed for Ontario Power Generation (OPG) and Bruce Power (BP), measures the deep and shallow personal dose equivalent quantities Hp(10) and Hp(0.07), respectively. Using these measured personal dose equivalent quantities and applying a beta-ray strength scaling factor to the Hp(0.07) measurement in particular, we have developed an algorithm that can be used to calculate the dose to the lens of the eye in mixed beta-gamma fields. This scaling factor has been developed and is primarily based on results obtained from extensive collaborative study, performed by Ontario Power Generation (OPG), Bruce Power (BP) and McMaster University, through Candu Owners Group (COG) support (Bohra et al., 2021; Laranjeiro et al., 2020). Furthermore, scaling factor F, also includes effects of protective glass eyewear and results from Whole body dosimetry intercomparison exercises. The algorithm to calculate eye lens dose at CANDU power plants has been developed, based on this scaling factor and operational dosimetric quantities Hp(10) and Hp(0.07).


Asunto(s)
Cristalino/efectos de la radiación , Plantas de Energía Nuclear , Exposición Profesional/análisis , Radiometría/métodos , Algoritmos , Canadá , Humanos
6.
Appl Radiat Isot ; 174: 109746, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33930726

RESUMEN

To address the issue of eye lens dosimetry in nuclear industry, we initiated the project to quantify the beta and gamma-ray source term in CANDU power plants and to convert this source term into dosimetric quantities of interest, such as eye lens dose and personal dose equivalents Hp(10), Hp(0.07). This way, the eye lens dose can be compared with dosimetric operational quantities to evaluate whether independent dosimetry is required for eye lens protection, or present dosimetry is adequate.


Asunto(s)
Partículas beta , Rayos gamma , Cristalino/efectos de la radiación , Centrales Eléctricas , Radiometría/métodos , Humanos , Método de Montecarlo , Radiometría/instrumentación , Conteo por Cintilación/métodos , Piel/efectos de la radiación
7.
Physiol Res ; 70(3): 401-412, 2021 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-33982581

RESUMEN

High dependency of arterial blood pressure (ABP) on enhanced sympathetic activity, which maintains vascular tone, leads to hypotension after hemodynamic insults that blunt the sympathetic activity. Therefore, we hypothesized that sympathovagal balance before tourniquet deflation (TD) determines the extent of a reduction in ABP after TD during total knee arthroplasty (TKA). Fifty-four hypertensive female patients undergoing TKA under spinal anesthesia were analyzed. The sympathovagal balance [low-to-high frequency ratio of heart rate variability (LF/HF)] before TD was defined as (LF/HF during 5 min before TD-preanesthetic LF/HF)/preanesthetic LF/HF (%). An increase in its value represents a shift in sympathovagal balance toward sympathetic predominance. The percent change in the mean ABP (MAP) after TD was defined as (minimum MAP during 10 min after TD-averaged MAP during 5 min before TD)/averaged MAP during 5 min before TD (%). Simple linear regression was performed to assess the correlation between the sympathovagal balance before TD and change in MAP after TD. The correlation was also assessed by multiple linear regression controlling for age, duration of tourniquet inflation, and spinal anesthesia-induced hypotension. Thirty-two minutes (on average) after tourniquet inflation, the MAP was decreased by 12.1 (-3.0 to 47.9) % [mean (range)] upon TD (P<0.001). The sympathovagal balance before TD was negatively proportional to the change in MAP after TD in both simple and multiple linear regression models (R2=0.323 and 0.340, P<0.001). A shift in sympathovagal balance toward sympathetic predominance before TD is associated with a decrease in ABP after TD.


Asunto(s)
Presión Arterial , Artroplastia de Reemplazo de Rodilla , Sistema Nervioso Simpático/fisiopatología , Torniquetes , Anciano , Anciano de 80 o más Años , Envejecimiento , Anestesia Raquidea , Femenino , Frecuencia Cardíaca , Humanos , Hipertensión/fisiopatología , Periodo Intraoperatorio , Persona de Mediana Edad , Resultado del Tratamiento , Nervio Vago/fisiopatología
8.
Radiat Prot Dosimetry ; 192(3): 309-320, 2020 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-33320200

RESUMEN

Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers' exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.


Asunto(s)
Cristalino , Plantas de Energía Nuclear , Bromuros , Humanos , Lantano , Método de Montecarlo , Radiometría
9.
Health Phys ; 117(3): 300-305, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31349356

RESUMEN

In a search to optimize neutron long counter design for overall efficiency and flat energy response, Monte Carlo simulations were carried out for a variety of detector design parameters using the Monte Carlo N-Particle Extended code. Based on the standard long counter design by McTaggart, moderator diameter, moderator back length, and longitudinal hole diameter were sequentially varied, and the sensitivity of each parameter to the long counter response was systematically analyzed. For each design, simulations were done in the neutron energy range of 1 keV to 10 MeV. From the simulation results, it turned out that out of the three moderator parameters, the moderator diameter is most sensitive for optimizing the long counter response. As the last design parameter, the effect of the central slow-neutron counter was investigated, which showed a significant difference in the response. The investigation of each design parameter gave clear insight on its effect on the long counter response and enabled one to determine the optimum condition.


Asunto(s)
Simulación por Computador , Método de Montecarlo , Neutrones , Aceleradores de Partículas/instrumentación , Radiometría/instrumentación , Algoritmos , Diseño de Equipo , Humanos , Dosis de Radiación
10.
Oper Dent ; 44(6): 574-580, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30702408

RESUMEN

Two cases of complicated crown fracture of the maxillary incisors were restored using the fragment reattachment technique. Root canal treatment was performed, and the fractured fragment was bonded to the tooth structure using a dentin adhesive system and a flowable composite resin, followed by the insertion of a fiber post using dual-cured resin cement. Reattached fragments have shown reliable prognosis without inflammatory signs around bonded junctions after long-term follow-up.


Asunto(s)
Recubrimiento Dental Adhesivo , Fracturas de los Dientes , Resinas Compuestas , Coronas , Restauración Dental Permanente , Estudios de Seguimiento , Humanos , Cementos de Resina , Corona del Diente
11.
Transplant Proc ; 51(5): 1511-1515, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31155184

RESUMEN

BACKGROUND: The autonomic innervation to a liver graft remains lost up to 1 year after liver transplant. Therefore, we investigated the effects of recipients' autonomic nervous activity on the extent of portal hyperperfusion of a partial liver graft in the absence of the autonomic innervation. METHODS: A total of 31 cirrhotic recipients undergoing right lobe living donor liver transplant were analyzed. Following a 10-minute absence of surgical stimulation after hepatic artery and bile duct reconstruction, the electrocardiogram and blood pressure waveforms were recorded for 5 minutes. Low-frequency (LF) and high-frequency (HF) powers and their ratio (LF/HF) were calculated using fast Fourier transform from the electrocardiogram waveform. A decrease in LF/HF represents a shift in sympathovagal balance toward parasympathetic predominance. Then, portal venous (PVF) and hepatic arterial (HAF) blood flows were measured in mL/min per 100 g of liver weight using spectral Doppler ultrasonography. A decrease in their ratio (PVF/HAF) represents attenuation of portal hyperperfusion. RESULTS: The medians of the PVF and HAF were 349 and 27 mL/min/100 g liver weight with interquartile ranges of 272 to 617 mL/min/100 g liver weight and 22 to 41 mL/min/100 g liver weight, respectively, yielding a median of the PVF/HAF of 13.7 (interquartile range, 8.5-21.3). The median of LF/HF was 0.67 (interquartile range, 0.16-1.45). With a reduction in LF/HF, PVF/HAF decreased according to an S-curve regression model between them (PVF/HAF=e2.743+-0.031LF/HF,adjustedR2=0.129,P=0.027). CONCLUSION: A shift in sympathovagal balance toward parasympathetic predominance is associated with attenuation of portal hyperperfusion in a partial liver graft.


Asunto(s)
Hemodinámica/fisiología , Circulación Hepática , Cirrosis Hepática/cirugía , Trasplante de Hígado , Sistema Nervioso Parasimpático/fisiología , Femenino , Humanos , Circulación Hepática/fisiología , Donadores Vivos , Masculino
12.
Med Phys ; 35(2): 608-16, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18383682

RESUMEN

Magnesium (Mg) is an element essential for many enzymatic reactions in the human body. Various human and animal studies suggest that changes in Mg status are linked to diseases such as cardiac arrhythmia, coronary heart disease, hypertension, premenstrual syndrome, and diabetes mellitus. Thus, knowledge of Mg levels in the human body is needed. A direct measurement of human blood serum, which contains only 0.3% of the total body Mg, is generally used to infer information about the status of Mg in the body. However, in many clinical situations, Mg stored in large levels, for example in bones, muscles, and soft tissues, needs to be monitored either to evaluate the efficacy of a treatment or to study the progression of diseases associated with the deficiency of total body Mg. This work presents a feasibility study of a noninvasive, in vivo neutron activation analysis (IVNAA) technique using the 26Mg (n, gamma) 27Mg reaction to measure Mg levels in human hands. The technique employs the McMaster University high beam current Tandetron accelerator hand irradiation facility and an array of eight NaI (T1) detectors arranged in a 4 pi geometry for delayed counting of the 0.844 and 1.014 MeV gamma rays emitted when 27Mg decays in the irradiated hand. Mg determination in humans using IVNAA of hands has been demonstrated to be feasible, with effective doses as low as one-quarter of those delivered in chest x rays. The overall experimental uncertainty in the measurements is estimated to be approximately 5% (1 sigma). The results are found to be in the range of the in vitro measurements reported for other cortical bones collected from different sites of the human skeleton, which confirms that this technique mainly provides a measure of the amount of Mg in hand bones. The average concentration of Mg determined in human hands is 10.96 +/- 1.25 (+/- 1 SD) mg Mg/g Ca. The coefficient of variation (11%) observed in this study is comparable with or lower than several studies using in vitro measurements reported in the literature and therefore allows for a quantitative intersubject comparison, even if to a limited extent. The features of the developed technique such as its simplicity, rapidity, accuracy, robustness, noninvasive nature, and very effective use of radiation doses, present the technique as a viable diagnostic tool available for trial in a clinical environment.


Asunto(s)
Huesos de la Mano/metabolismo , Magnesio/metabolismo , Análisis de Activación de Neutrones/métodos , Aceleradores de Partículas , Adulto , Anciano , Humanos , Persona de Mediana Edad , Análisis de Activación de Neutrones/instrumentación , Especificidad de Órganos , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular
13.
Phys Med Biol ; 52(6): 1693-703, 2007 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-17455391

RESUMEN

A neutron irradiation cavity for in vivo activation analysis has been characterized to estimate its dosimetric specifications. The cavity is defined to confine irradiation to the hand and modifies the neutron spectrum produced by a low energy accelerator neutron source to optimize activation per dose. Neutron and gamma-ray dose rates were measured with the microdosimetric technique using a tissue-equivalent proportional counter at the hand irradiation site and inside the hand access hole. For the outside of the cavity, a spherical neutron dose equivalent meter and a Farmer dosemeter were employed instead due to the low intensity of the radiation field. The maximum dose equivalent rate at the outside of the cavity was 2.94 microSv/100 microA min, which is lower by a factor of 1/2260 than the dose rate at the hand irradiation position. The local dose contributions from a hand, an arm and the rest of a body to the effective dose rate were estimated to be 1.73, 0.782 and 2.94 microSv/100 microA min, respectively. For the standard irradiation protocol of the in vivo hand activation, 300 microA min, an effective dose of 16.3 microSv would be delivered.


Asunto(s)
Análisis de Activación de Neutrones/métodos , Neutrones , Aceleradores de Partículas , Radiometría/métodos , Rayos gamma , Humanos , Análisis de Activación de Neutrones/instrumentación , Dosis de Radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
14.
Radiat Res ; 187(1): 42-49, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-28001909

RESUMEN

During space missions, astronauts are exposed to a stream of energetic and highly ionizing radiation particles that can suppress immune system function, increase cancer risks and even induce acute radiation syndrome if the exposure is large enough. As human exploration goals shift from missions in low-Earth orbit (LEO) to long-duration interplanetary missions, radiation protection remains one of the key technological issues that must be resolved. In this work, we introduce the NEUtron DOSimetry & Exploration (NEUDOSE) CubeSat mission, which will provide new measurements of dose and space radiation quality factors to improve the accuracy of cancer risk projections for current and future space missions. The primary objective of the NEUDOSE CubeSat is to map the in situ lineal energy spectra produced by charged particles and neutrons in LEO where most of the preparatory activities for future interplanetary missions are currently taking place. To perform these measurements, the NEUDOSE CubeSat is equipped with the Charged & Neutral Particle Tissue Equivalent Proportional Counter (CNP-TEPC), an advanced radiation monitoring instrument that uses active coincidence techniques to separate the interactions of charged particles and neutrons in real time. The NEUDOSE CubeSat, currently under development at McMaster University, provides a modern approach to test the CNP-TEPC instrument directly in the unique environment of outer space while simultaneously collecting new georeferenced lineal energy spectra of the radiation environment in LEO.


Asunto(s)
Planeta Tierra , Neutrones , Monitoreo de Radiación/instrumentación , Vuelo Espacial , Astronautas , Radiación Cósmica/efectos adversos , Diseño de Equipo , Humanos , Neutrones/efectos adversos , Exposición a la Radiación/análisis , Protección Radiológica
15.
Radiat Prot Dosimetry ; 171(4): 421-430, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26464524

RESUMEN

In order to investigate the radiation dose dependence on the incident proton energy, neutron and gamma-ray doses were measured using a tissue-equivalent proportional counter in the proton energy range of 1.95-2.50 MeV for the McMaster 7Li(p,n) neutron facility. Microdosimetric spectra were collected, and absorbed doses were determined at various positions inside the irradiation cavity, along the lateral axis and outside the shield to find out the spatial distributions of neutron and gamma-ray doses for each proton energy. In parallel with the absorbed dose measurements, MCNP Monte Carlo simulations were carried out and neutron fluence spectra were computed at various positions, which enabled determination of the neutron weighting factors. It was found that neutrons make a substantially dominant contribution to the total equivalent dose for most proton energies and positions. The effective dose for a human subject increased from 0.058 to 1.306 µSv µA-1 min-1 with the increase of proton energy from 1.95 to 2.5 MeV. It is expected that the reported data will be useful for 7Li(p,n) accelerator neutron users.


Asunto(s)
Dosis de Radiación , Radiometría/métodos , Algoritmos , Huesos/efectos de la radiación , Simulación por Computador , Humanos , Litio , Método de Montecarlo , Neutrones , Aceleradores de Partículas , Protones , Radiometría/instrumentación , Piel/efectos de la radiación , Distribución Tisular
16.
Physiol Meas ; 37(11): N76-N83, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27710928

RESUMEN

The time-dependent behaviour of sodium and chlorine was studied as a spinoff from a study of aluminum in the hand of subjects suffering from Alzheimer's disease and a control group, involving 15 Alzheimer's and 16 control subjects with an age range of 63-89 years. This was achieved using the in vivo neutron activation analysis system developed at McMaster University for the non-invasive measurement of aluminum, where a subject's hand is placed in a beam of accelerator-based thermalized neutrons, which activates elements by neutron capture. Following irradiation, the subject's hand is placed in a detection system comprising 9 NaI(Tl) detectors arranged in a 4π geometry to measure activated elements. The redistribution half-lives of the activation products 24Na and 38Cl from the hand were determined after correction for the physical half-life, by means of sequential analysis of the residual activity in the hand. The kinetic behaviours of sodium and chlorine were best characterized by an exponential function corresponding to the rapidly exchangeable pool. The mean redistribution half-lives from the hand for sodium and chlorine in the control subjects were 40.5 ± 17.4 min and 24.2 ± 8.5 min, respectively. For Alzheimer's disease subjects the mean redistribution half-lives were 58.2 ± 36.1 min for sodium and 33.6 ± 16.7 min for chlorine. There was no significant difference in chlorine and sodium redistribution half-lives between the Alzheimer's disease and control group subjects. These results are promising, given that the irradiation and counting protocol were optimized for the aluminum study, rendering them suboptimal for analyzing other elements and their rate of change with time. Further improvements include optimizing the irradiation protocol, longer counting times, and measuring the activity in the un-irradiated hand in various time intervals following irradiation.


Asunto(s)
Cloro/metabolismo , Mano , Sodio/metabolismo , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/metabolismo , Femenino , Humanos , Cinética , Masculino , Persona de Mediana Edad , Análisis de Activación de Neutrones
17.
Appl Radiat Isot ; 116: 34-40, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27474904

RESUMEN

An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5µg Al/g Ca) compared to the inverse-variance weighted mean (5.2µg Al/g Ca), rendering both equally applicable to human measurements.


Asunto(s)
Algoritmos , Aluminio/análisis , Interpretación Estadística de Datos , Huesos de la Mano/química , Análisis de Activación de Neutrones/métodos , Análisis Numérico Asistido por Computador , Materiales Biomiméticos/química , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
J Inorg Biochem ; 99(9): 1899-903, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16043224

RESUMEN

A biomarker of aluminium accumulation in the human body can play a valuable role in determining health effects of chronic aluminium exposure, complementing other human and environmental monitoring data. In vivo neutron activation provides such a non-invasive biomarker. To date, the best in vivo neutron activation system used thermalised neutrons from a nuclear reactor at Brookhaven National Laboratory, which suffered only slightly from interference from other elements, primarily phosphorus, and from the disadvantage of restricted accessibility. At McMaster, we use a nuclear reaction on an accelerator to select neutron energy, which eliminates the interferences. Spectral decomposition analysis improved sensitivity. A new 4pi detection system also enhanced sensitivity. Together these improvements yield a minimum detection limit of 0.24 mgAl in a hand, slightly better than at Brookhaven and equivalent to "normal" levels. Further improvements should result from a new irradiation cavity and from using a higher proton current on the accelerator to shorten irradiation times. The system is now ready for pilot human studies.


Asunto(s)
Aluminio/análisis , Huesos/química , Humanos , Análisis de Activación de Neutrones , Sensibilidad y Especificidad
19.
Appl Radiat Isot ; 63(4): 475-9, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15994089

RESUMEN

An existing McMaster University in vivo prompt gamma neutron activation analysis system has been improved in order to reduce the cadmium detection limit in the kidney and liver. The detection limit for the kidney was found to be 1.7 mg, a greater than factor of 2 improvement over the previous results obtained at McMaster. The liver detection limit was determined to be 3.3 ppm. The corresponding skin dose for these measurements was only 0.5 mSv. The effect of kidney position on the detection limit also was examined. Figures of merit were calculated in order to compare the performance of the current system to others.


Asunto(s)
Cadmio/análisis , Rayos gamma , Riñón/química , Hígado/química , Análisis de Activación de Neutrones , Humanos , Sensibilidad y Especificidad
20.
Physiol Meas ; 36(11): 2217-30, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26393663

RESUMEN

Selenium (Se) is an element that, in trace quantities, plays an important role in the normal function of a number of biological processes in humans. Many studies have demonstrated that selenium deficiency in the body may contribute to an increased risk for certain neoplastic, cardiovascular, osseous, and nervous system diseases including retardation of bone formation. However, at higher concentrations Se is cytotoxic. For these reasons it is desirable to have a means of monitoring selenium concentration in humans.This paper presents the outcome of a feasibility study carried out for measuring selenium in humans using in vivo neutron activation analysis (IVNAA). In this technique a small dose of neutrons is delivered to the organ of interest, the neutrons are readily captured by the target nuclei, and the γ-rays given off are detected outside of the body. For the present study, human hand (bone) tissue equivalent phantoms were prepared with varying amounts of Se. These were irradiated by a low energy fast neutron beam produced by the (7)Li(p,n)(7)Be reaction employing the high beam current Tandetron accelerator. The counting data saved using a 4π NaI(TI) detection system were analyzed. The selenium was detected via the neutron capture reaction, (76)Se(n,γ)(77 m)Se, whereas calcium was detected through the (48)Ca(n,γ)(49)Ca reaction for the purpose of normalization of the Se signals to the calcium signals. From the calibration lines drawn between Se/Ca concentrations and Se/Ca counts ratio, the minimum detection limits (MDLs) were computed for two sets of phantoms irradiated under different irradiation parameters.In this study the optimized MDL value was determined to be 81 ng g(-1) (Se/phantom mass) for an equivalent dose of 188 mSv to the phantom. This MDL was found at least 10 times lower than the reported data on Se concentration measured in bone tissues. It was concluded that the NAA technique would be a feasible means of performing in vivo measurements of selenium in humans. Currently the data on in vivo measurement of selenium in humans are limited; the results of the present study would greatly contribute to the present data.


Asunto(s)
Análisis de Activación de Neutrones/métodos , Selenio/análisis , Calcio/análisis , Calibración , Estudios de Factibilidad , Huesos de la Mano , Humanos , Límite de Detección , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda