1.
Ann Ig ; 31(6): 576-581, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31616901

RESUMEN

The WHO Global Action Plan on physical activity underlines the binomial "diet and physical activity" for the maintenance of well-being state. The adequate nutritional intake is required for sport and can be achieved by a well-adjusted diet without adding artificial food supplements, whose abuse can even represent a risk and appear as an antechamber of doping. Within a national doping prevention project, a peer education tool was realized in the form of a book and e-book, based on the principle of the Mediterranean Diet as an effective nutritional support in sport and physical activity. This health-literacy book contains recipes from all Italian regions revised for their capability to satisfy sport nutritional needs.


Asunto(s)
Atletas , Dieta Mediterránea , Ejercicio Físico/fisiología , Educación en Salud/métodos , Libros , Libros de Cocina como Asunto , Dieta , Suplementos Dietéticos , Doping en los Deportes/prevención & control , Humanos , Italia , Grupo Paritario
2.
Anaesthesia ; 73(8): 972-979, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29492954

RESUMEN

Spirometric monitoring provides precise measurement and delivery of tidal volumes within a narrow range, which is essential for lung-protective strategies that aim to reduce morbidity and mortality in mechanically-ventilated patients. Conventional anaesthesia ventilators include inbuilt spirometry to monitor inspiratory and expiratory tidal volumes. The GE Aisys CS2 anaesthesia ventilator allows additional near-patient spirometry via a sensor interposed between the proximal end of the tracheal tube and the respiratory tubing. Near-patient and inbuilt spirometry of two different GE Aisys CS2 anaesthesia ventilators were compared in an in-vitro study. Assessments were made of accuracy and variability in inspiratory and expiratory tidal volume measurements during ventilation of six simulated paediatric lung models using the ASL 5000 test lung. A total of 9240 breaths were recorded and analysed. Differences between inspiratory tidal volumes measured with near-patient and inbuilt spirometry were most significant in the newborn setting (p < 0.001), and became less significant with increasing age and weight. During expiration, tidal volume measurements with near-patient spirometry were consistently more accurate than with inbuilt spirometry for all lung models (p < 0.001). Overall, the variability in measured tidal volumes decreased with increasing tidal volumes, and was smaller with near-patient than with inbuilt spirometry. The variability in measured tidal volumes was higher during expiration, especially with inbuilt spirometry. In conclusion, the present in-vitro study shows that measurements with near-patient spirometry are more accurate and less variable than with inbuilt spirometry. Differences between measurement methods were most significant in the smallest patients. We therefore recommend near-patient spirometry, especially for neonatal and paediatric patients.


Asunto(s)
Pulmón/fisiología , Espirometría/métodos , Volumen de Ventilación Pulmonar/fisiología , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Modelos Biológicos , Monitoreo Fisiológico , Respiración Artificial , Ventiladores Mecánicos
3.
Anaesthesia ; 61(10): 978-83, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16978314

RESUMEN

Cuff volume-pressure curves and cuff pressure-tracheal wall pressure relationships were investigated in eight brands of currently available cuffed, paediatric tracheal tubes with internal diameters of 5.0 mm. Cuff volume-pressure curves were measured with the cuff unrestricted and with the cuff placed within a tracheal model with wall pressure measurements. With the tracheal tube cuffs, unrestricted cuff compliance at 20 cmH(2)O cuff pressure varied between 0.06 and 0.3 ml x cmH(2)O(-1). With the cuff restricted within the model trachea, all tracheal tube cuffs became considerably less compliant (0.01-0.09 ml x cmH(2)O(-1)). We found tracheal wall pressure was similar to the cuff pressure as long as the resulting cuff diameter was sufficiently large freely to drape the inner tracheal wall. We found that, regardless of whether a higher or lower compliant tube cuff was used, cuff hyperinflation uniformly resulted in potentially compromised tracheal mucosal blood flow; cuff pressure monitoring using cuff pressure limitation is therefore strongly recommended.


Asunto(s)
Intubación Intratraqueal/instrumentación , Tráquea/fisiología , Niño , Adaptabilidad , Humanos , Intubación Intratraqueal/métodos , Modelos Anatómicos , Presión , Flujo Sanguíneo Regional , Tráquea/irrigación sanguínea
4.
J Autom Methods Manag Chem ; 24(2): 41-7, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-18924742

RESUMEN

The paper describes an integrated luminometer able to perform fluorescence (FL), room temperature phosphorescence (RTP) and chemiluminescence (CL) measurements on seawater samples. The technical details of the instrumentation are presented together with flow injection (FI) manifolds for the determination of cadmium and zinc (by FL), lead (RTP) and cobalt (CL). The analytical figures of merit are given for each manifold and results are presented for the determination of the four trace metals in seawater reference materials (NASS-5, SLEW-2) and Scheldt estuarine water samples.