Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Heart J ; 43(26): 2469-2478, 2022 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-34435642

RESUMEN

AIMS: Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified 'non-MR conditional' due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads. METHODS AND RESULTS: Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1-8.3). CONCLUSIONS: There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Electrónica , Humanos , Imagen por Resonancia Magnética/efectos adversos , Espectroscopía de Resonancia Magnética
2.
J Am Coll Cardiol ; 84(6): 540-557, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39084829

RESUMEN

BACKGROUND: Type 2 diabetes (T2D) is characterized by insulin resistance (IR) and dysregulated insulin secretion. Glucagon-like peptide-1 receptor agonist liraglutide promotes insulin secretion, whereas thiazolidinedione-pioglitazone decreases IR. OBJECTIVES: This study aimed to compare the efficacies of increasing insulin secretion vs decreasing IR strategies for improving myocardial perfusion, energetics, and function in T2D via an open-label randomized crossover trial. METHODS: Forty-one patients with T2D (age 63 years [95% CI: 59-68 years], 27 [66%] male, body mass index 27.8 kg/m2) [95% CI: 26.1-29.5 kg/m2)]) without cardiovascular disease were randomized to liraglutide or pioglitazone for a 16-week treatment followed by an 8-week washout and a further 16-week treatment with the second trial drug. Participants underwent rest and dobutamine stress 31phosphorus magnetic resonance spectroscopy and cardiovascular magnetic resonance for measuring the myocardial energetics index phosphocreatine to adenosine triphosphate ratio, myocardial perfusion (rest, dobutamine stress myocardial blood flow, and myocardial perfusion reserve), left ventricular (LV) volumes, systolic and diastolic function (mitral in-flow E/A ratio), before and after treatment. The 6-minute walk-test was used for functional assessments. RESULTS: Pioglitazone treatment resulted in significant increases in LV mass (96 g [95% CI: 68-105 g] to 105 g [95% CI: 74-115 g]; P = 0.003) and mitral-inflow E/A ratio (1.04 [95% CI: 0.62-1.21] to 1.34 [95% CI: 0.70-1.54]; P = 0.008), and a significant reduction in LV concentricity index (0.79 mg/mL [95% CI: 0.61-0.85 mg/mL] to 0.73 mg/mL [95% CI: 0.56-0.79 mg/mL]; P = 0.04). Liraglutide treatment increased stress myocardial blood flow (1.62 mL/g/min [95% CI: 1.19-1.75 mL/g/min] to 2.08 mL/g/min [95% CI: 1.57-2.24 mL/g/min]; P = 0.01) and myocardial perfusion reserve (2.40 [95% CI: 1.55-2.68] to 2.90 [95% CI: 1.83-3.18]; P = 0.01). Liraglutide treatment also significantly increased the rest (1.47 [95% CI: 1.17-1.58] to 1.94 [95% CI: 1.52-2.08]; P =0.00002) and stress phosphocreatine to adenosine triphosphate ratio (1.32 [95% CI: 1.05-1.42] to 1.58 [95% CI: 1.19-1.71]; P = 0.004) and 6-minute walk distance (488 m [95% CI: 458-518 m] to 521 m [95% CI: 481-561 m]; P = 0.009). CONCLUSIONS: Liraglutide treatment resulted in improved myocardial perfusion, energetics, and 6-minute walk distance in patients with T2D, whereas pioglitazone showed no effect on these parameters (Lean-DM [Targeting Beta-cell Failure in Lean Patients With Type 2 Diabetes]; NCT04657939).


Asunto(s)
Estudios Cruzados , Diabetes Mellitus Tipo 2 , Tolerancia al Ejercicio , Hipoglucemiantes , Liraglutida , Pioglitazona , Humanos , Masculino , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/fisiopatología , Diabetes Mellitus Tipo 2/metabolismo , Persona de Mediana Edad , Liraglutida/uso terapéutico , Liraglutida/farmacología , Femenino , Anciano , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/farmacología , Tolerancia al Ejercicio/efectos de los fármacos , Tolerancia al Ejercicio/fisiología , Pioglitazona/uso terapéutico , Circulación Coronaria/efectos de los fármacos , Circulación Coronaria/fisiología , Resistencia a la Insulina/fisiología
3.
Eur Heart J Cardiovasc Imaging ; 23(8): 1117-1126, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-34331054

RESUMEN

AIMS: Differentiating exudative from transudative effusions is clinically important and is currently performed via biochemical analysis of invasively obtained samples using Light's criteria. Diagnostic performance is however limited. Biochemical composition can be measured with T1 mapping using cardiovascular magnetic resonance (CMR) and hence may offer diagnostic utility for assessment of effusions. METHODS AND RESULTS: A phantom consisting of serially diluted human albumin solutions (25-200 g/L) was constructed and scanned at 1.5 T to derive the relationship between fluid T1 values and fluid albumin concentration. Native T1 values of pleural and pericardial effusions from 86 patients undergoing clinical CMR studies retrospectively analysed at four tertiary centres. Effusions were classified using Light's criteria where biochemical data was available (n = 55) or clinically in decompensated heart failure patients with presumed transudative effusions (n = 31). Fluid T1 and protein values were inversely correlated both in the phantom (r = -0.992) and clinical samples (r = -0.663, P < 0.0001). T1 values were lower in exudative compared to transudative pleural (3252 ± 207 ms vs. 3596 ± 213 ms, P < 0.0001) and pericardial (2749 ± 373 ms vs. 3337 ± 245 ms, P < 0.0001) effusions. The diagnostic accuracy of T1 mapping for detecting transudates was very good for pleural and excellent for pericardial effusions, respectively [area under the curve 0.88, (95% CI 0.764-0.996), P = 0.001, 79% sensitivity, 89% specificity, and 0.93, (95% CI 0.855-1.000), P < 0.0001, 95% sensitivity; 81% specificity]. CONCLUSION: Native T1 values of effusions measured using CMR correlate well with protein concentrations and may be helpful for discriminating between transudates and exudates. This may help focus the requirement for invasive diagnostic sampling, avoiding unnecessary intervention in patients with unequivocal transudative effusions.


Asunto(s)
Derrame Pericárdico , Derrame Pleural , Exudados y Transudados/diagnóstico por imagen , Exudados y Transudados/metabolismo , Humanos , Imagen por Resonancia Magnética , Derrame Pericárdico/diagnóstico por imagen , Derrame Pleural/diagnóstico por imagen , Estudios Retrospectivos
4.
BMJ Qual Saf ; 28(10): 853-858, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30760606

RESUMEN

BACKGROUND: Patients with cardiac pacemakers and defibrillators are disadvantaged because of poor access to MRI scans, leading to late and misdiagnosis particularly for cancer and neurological disease. New technology allied to tested protocols now allows safe MRI scanning of such patients; however, logistical barriers persist. AIM: To deliver a streamlined sustainable service that provides timely MRI scans to patients with cardiac implantable electronic devices (CIEDs). METHODS: Patients requested a 'one-stop' service for MRI, whereby devices could be reprogrammed and scans acquired at a single location and visit. To provide this 'one-stop' service, we trained a team including administrators, physicians, cardiac physiologists and radiographers. A standard protocol was used to prevent unnecessary request refusals and delays to scheduling. Service volume, waiting time and safety were analysed 6 months before and 2 years after service redesign. Waiting times for internal and external inpatient referrals plus time to treatment for patients on a cancer pathway were analysed. RESULTS: 215 MRI scans were performed over 2 years. After service redesign, MRI provision increased six-fold to 20 times the national average with reduced waiting time from 60 to 15 days and no adverse events. Departmental throughput was maintained. 85 (40%) referrals were external. 41 (19%) inpatients were scanned, reducing bed-stay by 3 days for internal referrals. 24 (11%) scans were for suspected cancer, 83% allowed treatment within the national standard of 62 days. There was no preintervention service for either inpatients or suspected cancer investigation. CONCLUSION: Implementation of a 'one-stop' service model to provide MRI for patients with CIEDs is safe, streamlined, scalable and has reduced delays making economic and clinical sense. Protocols and checklists are available at mrimypacemaker.com.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética/métodos , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico por imagen , Seguridad del Paciente , Mejoramiento de la Calidad , Accidente Cerebrovascular/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda