Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Magn Reson Med ; 77(5): 1831-1840, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27170060

RESUMEN

PURPOSE: To develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. METHODS: A disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding was performed by tilting the disks with a golden angle. The sharpness was first calculated at different T2* values. Then, the sharpness was measured on phantom using variable undersampling ratios. Finally, the sampling method was validated by whole brain time-of-flight angiography and ultrasmall superparamagnetic iron oxide (USPIO) enhanced free-breathing liver angiography on mouse. RESULTS: The in vitro results demonstrated the robustness of the method for short T2* and high undersampling ratios. In vivo experiments showed the ability to properly detect small vessels in the brain with an acquisition time shorter than 1 min. Free-breathing mice liver angiography showed the insensitivity of this protocol toward motions and flow artifacts, and enabled the visualization of liver motion during breathing. CONCLUSIONS: The method implemented here allowed fast 3D k-space sampling with a high undersampling ratio. Combining the advantages of center-out spirals with the flexibility of the golden angle approach could have major implications for real-time imaging. Magn Reson Med 77:1831-1840, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Angiografía , Animales , Artefactos , Compuestos Férricos/química , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Hígado/patología , Magnetismo , Ratones , Ratones Endogámicos C57BL , Movimiento (Física) , Fantasmas de Imagen
2.
J Magn Reson Imaging ; 44(2): 355-65, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26778077

RESUMEN

PURPOSE: To develop and assess a 3D-cine self-gated method for cardiac imaging of murine models. MATERIALS AND METHODS: A 3D stack-of-stars (SOS) short echo time (STE) sequence with a navigator echo was performed at 7T on healthy mice (n = 4) and mice with acute myocardial infarction (MI) (n = 4) injected with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. In all, 402 spokes were acquired per stack with the incremental or the golden angle method using an angle increment of (360/402)° or 222.48°, respectively. A cylindrical k-space was filled and repeated with a maximum number of repetitions (NR) of 10. 3D cine cardiac images at 156 µm resolution were reconstructed retrospectively and compared for the two methods in terms of contrast-to-noise ratio (CNR). The golden angle images were also reconstructed with NR = 10, 6, and 3, to assess cardiac functional parameters (ejection fraction, EF) on both animal models. RESULTS: The combination of 3D SOS-STE and USPIO injection allowed us to optimize the identification of cardiac peaks on navigator signal and generate high CNR between blood and myocardium (15.3 ± 1.0). The golden angle method resulted in a more homogeneous distribution of the spokes inside a stack (P < 0.05), enabling reducing the acquisition time to 15 minutes. EF was significantly different between healthy and MI mice (P < 0.05). CONCLUSION: The method proposed here showed that 3D-cine images could be obtained without electrocardiogram or respiratory gating in mice. It allows precise measurement of cardiac functional parameters even on MI mice. J. Magn. Reson. Imaging 2016;44:355-365.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Dextranos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Nanopartículas de Magnetita , Infarto del Miocardio/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Animales , Medios de Contraste , Aumento de la Imagen/métodos , Ratones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
NMR Biomed ; 28(7): 881-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25989986

RESUMEN

Mapping longitudinal relaxation times in 3D is a promising quantitative and non-invasive imaging tool to assess cardiac remodeling. Few methods are proposed in the literature allowing us to perform 3D T1 mapping. These methods often require long scan times and use a low number of 3D images to calculate T1 . In this project, a fast 3D T1 mapping method using a stack-of-spirals sampling scheme and regular RF pulse excitation at 7 T is presented. This sequence, combined with a newly developed fitting procedure, allowed us to quantify T1 of the whole mouse heart with a high spatial resolution of 208 × 208 × 315 µm(3) in 10-12 min acquisition time. The sensitivity of this method for measuring T1 variations was demonstrated on mouse hearts after several injections of manganese chloride (doses from 25 to 150 µmol kg(-1) ). T1 values were measured in vivo in both pre- and post-contrast experiments. This protocol was also validated on ischemic mice to demonstrate its efficiency to visualize tissue damage induced by a myocardial infarction. This study showed that combining spiral gradient shape and steady RF excitation enabled fast and robust 3D T1 mapping of the entire heart with a high spatial resolution.


Asunto(s)
Algoritmos , Ventrículos Cardíacos/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Cloruro de Magnesio , Infarto del Miocardio/patología , Animales , Medios de Contraste , Aumento de la Imagen/métodos , Ratones , Ratones Endogámicos C57BL , Dosis de Radiación , Ondas de Radio , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Sci Rep ; 6: 39449, 2016 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-27995976

RESUMEN

Although MEMRI (Manganese Enhanced MRI) informations were obtained on primary tumors in small animals, MEMRI data on metastases are lacking. Thus, our goal was to determine if 3D Look-Locker T1 mapping was an efficient method to evaluate Mn ions transport in brain metastases in vivo. The high spatial resolution in 3D (156 × 156 × 218 µm) of the sequence enabled to detect metastases of 0.3 mm3. In parallel, the T1 quantitation enabled to distinguish three populations of MDA-MB-231 derived brain metastases after MnCl2 intravenous injection: one with a healthy blood-tumor barrier that did not internalize Mn2+ ions, and two others, which T1 shortened drastically by 54.2% or 24%. Subsequent scans of the mice, enabled by the fast acquisition (23 min), demonstrated that these T1 reached back their pre-injection values in 24 h. Contrarily to metastases, the T1 of U87-MG glioma remained 26.2% shorter for one week. In vitro results supported the involvement of the Transient Receptor Potential channels and the Calcium-Sensing Receptor in the uptake and efflux of Mn2+ ions, respectively. This study highlights the ability of the 3D Look-Locker T1 mapping sequence to study heterogeneities (i) amongst brain metastases and (ii) between metastases and glioma regarding Mn transport.


Asunto(s)
Neoplasias Encefálicas/patología , Imagen por Resonancia Magnética/métodos , Animales , Neoplasias Encefálicas/metabolismo , Línea Celular Tumoral , Cloruros/metabolismo , Medios de Contraste/metabolismo , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Manganeso/metabolismo , Compuestos de Manganeso/metabolismo , Ratones , Ratones Desnudos , Reproducibilidad de los Resultados
5.
Clin Exp Metastasis ; 33(2): 167-78, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26541711

RESUMEN

The goal of this study was to develop a 3D diffusion weighted sequence for free breathing liver imaging in small animals at high magnetic field. Hepatic metastases were detected and the apparent diffusion coefficients (ADC) were measured. A 3D SE-EPI sequence was developed by (i) inserting a water-selective excitation radiofrequency pulse to suppress adipose tissue signal and (ii) bipolar diffusion gradients to decrease the sensitivity to respiration motion. Mice with hepatic metastases were imaged at 7T by applying b values from 200 to 1100 s/mm(2). 3D images with high spatial resolution (182 × 156 × 125 µm) were obtained in only 8 min 32 s. The modified DW-SE-EPI sequence allowed to obtain 3D abdominal images of healthy mice with fat SNR 2.5 times lower than without any fat suppression method and sharpness 2.8 times higher than on respiration-triggered images. Due to the high spatial resolution, the core and the periphery of disseminated hepatic metastases were differentiated at high b-values only, demonstrating the presence of edema and proliferating cells (with ADC of 2.65 × 10(-3) and 1.55 × 10(-3) mm(2)/s, respectively). Furthermore, these metastases were accurately distinguished from proliferating ones within the same animal at high b-values (mean ADC of 0.38 × 10(-3) mm(2)/s). Metastases of less than 1.7 mm(3) diameter were detected. The new 3D SE-EPI sequence enabled to obtain diffusion information within liver metastases. In addition of intra-metastasis heterogeneity, differences in diffusion were measured between metastases within an animal. This sequence could be used to obtain diffusion information at high magnetic field.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundario , Animales , Ratones , Ratones Endogámicos C57BL , Respiración
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda