Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Clin Microbiol ; 51(8): 2556-63, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23720792

RESUMEN

Cryptosporidium is a protozoan parasite responsible for gastroenteritis, especially in immunocompromised patients. Laboratory diagnosis of cryptosporidiosis relies on microscopy, antigen detection, and nucleic acid detection and analysis. Among the numerous molecular targets available, the 18S rRNA gene displays the best sensitivity and sequence variations between species and can be used for molecular typing assays. This paper presents a new real-time PCR assay for the detection and quantification of all Cryptosporidium species associated with the identification of Cryptosporidium hominis and Cryptosporidium parvum. The sensitivity and specificity of this new PCR assay were assessed on a multicentric basis, using well-characterized Cryptosporidium-positive and -negative human stool samples, and the efficiencies of nine extraction methods were comparatively assessed using Cryptosporidium-seeded stool samples and phosphate-buffered saline samples. A comparison of extraction yields showed that the most efficient extraction method was the Boom technique in association with mechanical grinding, and column extraction showed higher binding capacity than extraction methods based on magnetic silica. Our PCR assay was able to quantify at least 300 oocysts per gram of stool. Satisfactory reproducibility between laboratories was observed. The two main species causing human disease, Cryptosporidium hominis and Cryptosporidium parvum, were identified using a duplex real-time PCR assay with specific TaqMan minor-groove-binding ligand (MGB) probes for the same amplicon. To conclude, this one-step quantitative PCR is well suited to the routine diagnosis of cryptosporidiosis since practical conditions, including DNA extraction, quantification using well-defined standards, and identification of the two main species infecting humans, have been positively assessed.


Asunto(s)
Criptosporidiosis/diagnóstico , Criptosporidiosis/parasitología , Cryptosporidium/clasificación , Cryptosporidium/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Carga de Parásitos/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Humanos , Sensibilidad y Especificidad
2.
medRxiv ; 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37162985

RESUMEN

Background: Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. Methods/Findings: In our ongoing USA feasibility/efficacy clinical trial, data collated with other ongoing and earlier published results proved high performance of an Immunochromatographic-test(ICT) that enables accurate, rapid diagnosis/treatment, establishing new paradigms for care. Overall results from patient blood and/or serum samples tested with ICT compared with gold-standard-predicate-test results found ICT performance for 4606 sera/1876 blood, 99.3%/97.5% sensitive and 98.9%/99.7% specific. However, in the clinical trial the FDA-cleared-predicate test initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO ASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. Conclusions/Significance: This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. Author's Summary: Toxoplasmosis is a major health burden for developed and developing countries, causing damage to eyes and brain, loss of life and substantial societal costs. Prompt diagnosis in gestational screening programs enables treatment, thereby relieving suffering, and leading to > 14-fold cost savings for care. Herein, we demonstrate that using an ICT that meets WHO ASSURED-criteria identifying persons with/without antibody to Toxoplasma gondii in sera and whole blood with high sensitivity and specificity, is feasible to use in USA clinical practice. We find this new approach can help to obviate the problem of detection of false positive anti- T.gondii IgM results for those without IgG antibodies to T.gondii when this occurs in present, standard of care, predicate USA FDA cleared available assays. Thus, this accurate test facilitates gestational screening programs and a global initiative to diagnose and thereby prevent and treat T.gondii infection. This minimizes likelihood of false positives (IgG and/or IgM) while maintaining maximum sensitivity. When isolated IgM antibodies are detected, it is necessary to confirm and when indicated continue follow up testing in ∼2 weeks to establish seroconversion. Presence of a positive ICT makes it likely that IgM is truly positive and a negative ICT makes it likely that IgM will be a false positive without infection. These results create a new, enthusiastically-accepted, precise paradigm for rapid diagnosis and validation of results with a second-line test. This helps eliminate alarm and anxiety about false-positive results, while expediting needed treatment for true positive results and providing back up distinguishing false positive tests.

3.
Scand J Immunol ; 62(6): 528-38, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16316420

RESUMEN

Contagious bovine pleuropneumonia, caused by Mycoplasma mycoides ssp. mycoides biotype small colony (MmmSC), is one of the most serious cattle diseases in Africa. Several observations suggested that MmmSC had evolved an efficient way to escape the bovine immune responses by triggering host-cell cytotoxicity. This study was implemented to determine whether the cytotoxic effect was due to apoptotic cell death. To that end, bovine blood cells were cultured for up to 3 days in the presence of viable or heat-killed MmmSC compared to unstimulated cultures. The findings provided evidence for a viable MmmSC-induced, time-dependent apoptosis in bovine blood leucocytes, whereas heat-killed MmmSC had no effect. Morphological and physiological changes (evidenced by TUNEL and annexin V staining) typical of apoptosis were observed in response to viable MmmSC. All the lymphocyte subsets as well as the monocyte/granulocyte subset exhibited extensive apoptosis after exposure to viable MmmSC. Our results demonstrated a potential role for MmmSC-secreted components as pathogenic factors able to induce programmed cell death in bovine blood leucocytes.


Asunto(s)
Apoptosis/fisiología , Leucocitos Mononucleares/inmunología , Leucocitos Mononucleares/metabolismo , Mycoplasma mycoides/inmunología , Animales , Anexina A5/metabolismo , Bovinos , Células Cultivadas , Inmunofenotipificación , Leucocitos Mononucleares/citología , Leucocitos Mononucleares/microbiología , Mycoplasma mycoides/citología , Mycoplasma mycoides/patogenicidad , Virulencia
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda