Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 517
Filtrar
1.
BJOG ; 128(11): 1824-1832, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33713380

RESUMEN

OBJECTIVE: To create a personalised machine learning model for prediction of severe adverse neonatal outcomes (SANO) during the second stage of labour. DESIGN: Retrospective Electronic-Medical-Record (EMR) -based study. POPULATION: A cohort of 73 868 singleton, term deliveries that reached the second stage of labour, including 1346 (1.8%) deliveries with SANO. METHODS: A gradient boosting model was created, analysing 21 million data points from antepartum features (e.g. gravidity and parity) gathered at admission to the delivery unit, and intrapartum data (e.g. cervical dilatation and effacement) gathered during the first stage of labour. Deliveries were allocated to high-risk and low-risk groups based on the Youden index to maximise sensitivity and specificity. MAIN OUTCOME MEASURES: SANO was defined as either umbilical cord pH levels ≤7.1 or 1-minute or 5-minute Apgar score ≤7. RESULTS: The model for prediction of SANO yielded an area under the receiver operating curve (AUC) of 0.761 (95% CI 0.748-0.774). A third of the cohort (33.5%, n = 24 721) were allocated to a high-risk group for SANO, which captured up to 72.1% of these cases (odds ratio 5.3, 95% CI 4.7-6.0; high-risk versus low-risk groups). CONCLUSIONS: Data acquired throughout the first stage of labour can be used to predict SANO during the second stage of labour using a machine learning model. Stratifying parturients at the beginning of the second stage of labour in a 'time out' session, can direct a personalised approach to management of this challenging aspect of labour, as well as improve allocation of staff and resources. TWEETABLE ABSTRACT: Personalised prediction score for severe adverse neonatal outcomes in labour using machine learning model.


Asunto(s)
Parto Obstétrico/estadística & datos numéricos , Segundo Periodo del Trabajo de Parto , Aprendizaje Automático , Admisión del Paciente/estadística & datos numéricos , Resultado del Embarazo , Adulto , Femenino , Número de Embarazos , Humanos , Presentación en Trabajo de Parto , Primer Periodo del Trabajo de Parto , Complicaciones del Trabajo de Parto/diagnóstico , Paridad , Valor Predictivo de las Pruebas , Embarazo , Curva ROC , Estudios Retrospectivos
7.
Analyst ; 140(5): 1510-5, 2015 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-25587577

RESUMEN

Materials with core-shell structures have distinct properties that lend themselves to a variety of potential applications. Characterization of small particle core-shell materials presents a unique analytical challenge. Herein, single particles of solid-state materials with core-shell structures were measured using on-line aerosol time-of-flight mass spectrometry (ATOFMS). Laser 'depth profiling' experiments verified the core-shell nature of two known core-shell particle configurations (<2 µm diameter) that possessed inverted, complimentary core-shell compositions (ZrO2@SiO2 versus SiO2@ZrO2). The average peak area ratios of Si and Zr ions were calculated to definitively show their core-shell composition. These ratio curves acted as a calibrant for an uncharacterized sample ­ a metal-organic framework (MOF) material surround by silica (UiO-66(Zr)@SiO2; UiO = University of Oslo). ATOFMS depth profiling was used to show that these particles did indeed exhibit a core-shell architecture. The results presented here show that ATOFMS can provide unique insights into core-shell solid-state materials with particle diameters between 0.2-3 µm.

8.
Ultrasound Obstet Gynecol ; 46(6): 724-9, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25760927

RESUMEN

OBJECTIVES: Correlation of the sonographic appearance of levator ani muscle (LAM) injury soon after delivery with that at long-term follow-up has not been described fully. We aimed to compare results of three-dimensional (3D) transperineal sonographic (TPS) evaluation of the LAM from the period immediately postpartum with long-term follow-up, to determine whether sonographic findings persist over time. METHODS: Primiparous women (n = 210) who had been examined by 3D-TPS in a previous study to determine LAM trauma 24-72 hours after delivery were invited to participate in a follow-up examination 3-21 months postpartum. We included in this study only women who were not pregnant when approached and who had not given birth in the interim. LAM trauma was diagnosed with 3D-TPS when we observed discontinuity and distortion of the most anteromedial part of the pubovisceral muscle in the coronal C-plane or rendered image. Initial and follow-up 3D-TPS results were compared using Cohen's kappa test for inter-rater agreement. RESULTS: Among the 87 women included in this study we found strong correlation between earlier and later sonographic appearance of LAM: 17/21 women with a sonographic finding of LAM injury in the period immediately postpartum were positive in the follow-up examination, and only 2/66 women negative for LAM damage at the first examination were found to have sonographic evidence of LAM defect at follow-up (Cohen's kappa, 0.805 (95% CI, 0.656-0.954), P < 0.001). CONCLUSIONS: Our findings suggest that 3D-TPS of the LAM is a reliable examination. A sonographic finding of LAM defect identified in the period immediately postpartum persists months or years after delivery; therefore, this test may be performed following delivery, or may be delayed without impacting the result. It is likely that this sonographic defect represents real anatomical disruption and is not an imaging artifact.


Asunto(s)
Canal Anal/diagnóstico por imagen , Parto Obstétrico/efectos adversos , Imagenología Tridimensional , Músculo Esquelético/diagnóstico por imagen , Adulto , Canal Anal/lesiones , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Músculo Esquelético/lesiones , Paridad , Diafragma Pélvico/diagnóstico por imagen , Periodo Posparto , Embarazo , Ultrasonografía , Adulto Joven
9.
Ultrasound Obstet Gynecol ; 45(5): 578-83, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24919785

RESUMEN

OBJECTIVES: Examination of the fetal venous system is a necessary part of complete fetal organ scanning to confirm landmark anatomy, such as the ductus venosus and course of the umbilical veins, and, whenever cardiovascular anomalies are identified, to exclude associated anomalous development of the fetal veins. We aimed to develop a protocol for systematic examination of the fetal venous system during midtrimester targeted organ scanning. METHODS: We included low-risk women with a singleton fetus presenting between January 2011 and June 2013 to our center for routine midtrimester (20-24 weeks) targeted organ scanning. Imaging of the venous system was added to the booked scan and comprised two-dimensional color Doppler scanning of the fetal abdomen in three discrete planes, two transverse and one longitudinal. The more caudal plane was obtained in a ventral or lateral transverse abdominal plane to image the umbilical vein, left portal vein, portal sinus, anterior right portal vein, posterior right portal vein, main portal vein and splenic vein and artery. Moving cephalad, a ventral or lateral transverse plane was obtained to image the right, middle and left hepatic veins and inferior vena cava (IVC). Finally, a longitudinal anteroposterior plane showed the umbilical vein, ductus venosus, IVC and left hepatic vein. In some cases the pulsed Doppler waveform of a given target vessel was also examined. Three-dimensional/4D ultrasound was applied as necessary, when anomalous cases were encountered. RESULTS: We examined 1810 women. Their body mass index ranged from 19 to 40 (mean, 24.7). In 38 (2.1%) women, the target anatomy was not visualized satisfactorily owing to maternal body habitus. A T-shaped configuration of the portal system vessels was observed in 63% of cases, an X-shaped configuration in 25% and an H-shaped configuration in 12%. During the study period, 24 congenital anomalies of the precordial venous system were diagnosed: nine cases of persistent right umbilical vein, seven of agenesis of the ductus venosus, five of anomalous portal venous drainage and three of interrupted IVC with azygos continuation. CONCLUSIONS: Examination of the fetal venous system is feasible with the application of three abdominal planes. While a venous system scan is not practicable as part of a screening-level examination, mastery of the normal anatomy is an essential part of the professional knowledge base, in order to provide ready and complete scanning of the system in cases of suspected anomalies or disordered cardiac function.


Asunto(s)
Abdomen/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen , Hígado/diagnóstico por imagen , Vena Porta/patología , Ultrasonografía Prenatal , Venas Umbilicales/diagnóstico por imagen , Abdomen/embriología , Adulto , Enfermedades Cardiovasculares/embriología , Enfermedades Cardiovasculares/patología , Femenino , Desarrollo Fetal , Humanos , Hígado/embriología , Vena Porta/embriología , Embarazo , Segundo Trimestre del Embarazo , Estudios Prospectivos , Venas Umbilicales/embriología
10.
Colorectal Dis ; 17(6): 522-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25537083

RESUMEN

AIM: Preclinical studies have suggested that nitinol-based compression anastomosis might be a viable solution to anastomotic leak following low anterior resection. A prospective multicentre open label study was therefore designed to evaluate the performance of the ColonRing(™) in (low) colorectal anastomosis. METHOD: The primary outcome measure was anastomotic leakage. Patients were recruited at 13 different colorectal surgical units in Europe, the United States and Israel. Institutional review board approval was obtained. RESULTS: Between 21 March 2010 and 3 August 2011, 266 patients completed the study protocol. The overall anastomotic leakage rate was 5.3% for all anastomoses, including a rate of 3.1% for low anastomoses. Septic anastomotic complications occurred in 8.3% of all anastomoses and 8.2% of low anastomoses. CONCLUSION: Nitinol compression anastomosis is safe, effective and easy to use and may offer an advantage for low colorectal anastomosis. A prospective randomized trial comparing ColonRing(™) with conventional stapling is needed.


Asunto(s)
Anastomosis Quirúrgica/instrumentación , Fuga Anastomótica/terapia , Colon/cirugía , Recto/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Aleaciones/uso terapéutico , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Colectomía/métodos , Europa (Continente) , Femenino , Humanos , Israel , Masculino , Persona de Mediana Edad , Vigilancia de Productos Comercializados , Estudios Prospectivos , Sepsis/epidemiología , Sepsis/etiología , Estados Unidos , Adulto Joven
11.
Intern Med J ; 45(10): 1026-31, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26122531

RESUMEN

BACKGROUND: The prevalence of spontaneous bacterial peritonitis (SBP) in hospitalised cirrhotics with ascites is 10-30%. Treatment for refractory ascites includes paracenteses, transjugular intrahepatic portosystemic shunt or drain placement; the latter is discouraged due to a perceived infection risk. AIM: This study aimed to evaluate the risk of bacterial peritonitis (BP) with peritoneal drains in patients with Child-Pugh class B or C cirrhosis and determine their impact on survival. METHODS: We conducted a retrospective review of end-stage liver disease (ESLD) patients with non-malignant, refractory ascites who had peritoneal drains placed for ≥3 days at Loyola University between 1999 and 2009. Cell counts were performed at drain placement and within 72 h. BP was defined as ascitic polymorphonuclear neutrophils >250/mm(3) . Univariate analysis assessed the association between demographics, laboratory markers and development of BP. Kaplan-Meier curve estimates by infection were constructed and survival distributions were compared using log-rank statistic. RESULTS: There were 227 drain placements during the study period. Twenty-two per cent were diagnosed with BP (12% had SBP at drain placement; 10% developed BP within 72 h). There was no association between BP and baseline characteristics. Patients who developed BP within 72 h of drain placement had 50% mortality at 5 months compared with 50 months in those without infection (log-rank P ≤ 0.003). CONCLUSION: In ESLD patients who received an indwelling peritoneal catheter, there was 10% risk of developing BP and significant mortality increase. Though placing drains is not the mainstay of treatment for refractory ascites, we confirm the theoretical adverse risk of peritoneal drains on infection and survival in cirrhotics.


Asunto(s)
Ascitis/cirugía , Infecciones Bacterianas/mortalidad , Catéteres de Permanencia/efectos adversos , Drenaje/efectos adversos , Enfermedad Hepática en Estado Terminal/cirugía , Cirrosis Hepática/complicaciones , Peritonitis/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos
12.
Chem Res Toxicol ; 27(7): 1092-103, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24857813

RESUMEN

The metabolic fate of a compound is determined by numerous factors including its chemical structure. Although the metabolic options for a variety of functional groups are well understood and can often provide a rationale for the comparison of toxicity based on structural analogy, at times quite minor structural variations may have major consequences for metabolic outcomes and toxicity. In this perspective, the effects of structural variations on metabolic outcomes is detailed for a group of related hydroxy- and alkoxy-substituted allyl- and propenylbenzenes. These classes of compounds are naturally occurring constituents of a variety of botanical-based food items. The classes vary from one another by the presence or absence of alkylation of their para-hydroxyl substituents and/or the position of the double bond in the alkyl side chain. We provide an overview of how these subtle structural variations alter the metabolism of these important food-borne compounds, ultimately influencing their toxicity, particularly their DNA reactivity and carcinogenic potential. The data reveal that detailed knowledge of the consequences of subtle structural variations for metabolism is essential for adequate comparison of structurally related chemicals. Taken together, it is concluded that predictions in toxicological risk assessment should not be performed on the basis of structural analogy only but should include an analogy of metabolic pathways across compounds and species.


Asunto(s)
Derivados del Benceno , Carcinógenos , Animales , Derivados del Benceno/química , Derivados del Benceno/farmacocinética , Derivados del Benceno/toxicidad , Biotransformación , Carcinógenos/química , Carcinógenos/farmacocinética , Carcinógenos/toxicidad , Humanos
13.
Inorg Chem ; 53(13): 7014-9, 2014 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-24943327

RESUMEN

A series of geometrically constrained, cross-linked benzene dicarboxylic acid (bdc) derivatives have been synthesized and incorporated into the canonical isoreticular metal-organic framework (IRMOF) lattice. Only certain cross-links, which allow for the proper relative orientation of the bdc subunits, form the desired IRMOF. Design criteria from these cross-linked ligands allowed for the rational design of two oligomeric ligands composed of three bdc monomers tethered together. These oligomeric ligands were also readily incorporated into an IRMOF lattice with a high degree of crystallinity and porosity, providing a new dimension to rational ligand design for metal-organic frameworks.

15.
Ultrasound Obstet Gynecol ; 44(6): 700-3, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24510840

RESUMEN

OBJECTIVES: Correlation of the sonographic finding of levator ani muscle (LAM) injuries with clinical examination in primiparous women following vaginal delivery has not been fully described. We aimed to examine the correlation of three-dimensional transperineal ultrasound (3D-TPS) finding of LAM defects with results of clinical examination of the pelvic floor, at intermediate follow-up. METHODS: Subjects were primiparae 3-21 months following vaginal delivery, who had not become pregnant or delivered in the interim. On 3D-TPS, LAM trauma was diagnosed when discontinuity and distortion were visible in the most anteromedial part of the pubovisceral muscle in the coronal C-plane or rendered image. Clinical examination was performed by a physiotherapist who was blinded to the ultrasound results, and included palpation of the medial and lateral parts of the LAM mass, evaluation of tissue quality and whether there was any palpable gap. Muscle strength was evaluated using the modified Oxford scale. RESULTS: Eighty-seven women were included, 19 (21.8%) of whom were found to have a sonographic LAM injury. Oxford score palpation parameter of asymmetric muscle mass or texture was significantly correlated with the finding of a LAM defect: of 68 women with normal 3D-TPS, 22 (32.4%) were found to have asymmetry of muscle mass or tissue quality on clinical examination vs 12 (63.2%) of 19 women with sonographic evidence of LAM injury (P = 0.016). Muscle strength and endurance parameters did not significantly correlate with the 3D-TPS findings. CONCLUSION: Our findings suggest that persistent 3D-TPS LAM injury after primary vaginal delivery has clinical expression in changes in mass and texture of the LAM, as assessed by palpation.


Asunto(s)
Complicaciones del Trabajo de Parto/diagnóstico por imagen , Diafragma Pélvico/lesiones , Examen Físico , Adulto , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Fuerza Muscular , Complicaciones del Trabajo de Parto/diagnóstico , Complicaciones del Trabajo de Parto/fisiopatología , Paridad , Diafragma Pélvico/diagnóstico por imagen , Diafragma Pélvico/fisiopatología , Perineo/diagnóstico por imagen , Periodo Posparto , Embarazo , Método Simple Ciego , Ultrasonografía
16.
Ultrasound Obstet Gynecol ; 42(2): 182-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23288668

RESUMEN

OBJECTIVES: Fetal tricuspid annular plane systolic excursion (f-TAPSE) is a modified method to measure the vertical movement of the tricuspid valve annulus by M-mode ultrasound, in order to assess the fetal right heart. Evaluation of right heart function is well-recognized in pediatric and adult cardiology, but has not been studied widely in the fetus. We aimed to study f-TAPSE in the second half of gestation in normal fetuses, to establish reference ranges for this measure, to evaluate the usefulness of spatiotemporal image correlation (STIC) M-mode in obtaining it, and to compare conventional M-mode and STIC M-mode-based measures of f-TAPSE. METHODS: We recruited gravidae presenting to our centers from 20 to 38 weeks for targeted organ scans, fetal echocardiography or third-trimester fetal surveillance, with structurally normal singleton fetuses and verified gestational age (GA). Because of the small number of subjects at the lower limit, fetuses at 20 and those at 21 weeks were combined into a single group ('21 weeks'). During the booked scan, in addition to standard biometry, M-mode was applied to the tricuspid annulus, parallel to the ventricular septum, and the amplitude of the resulting wave was measured. To allow comparison with STIC M-mode, a STIC volume was acquired and saved. In post-processing, the volume was rotated to show an apical four-chamber view, and f-TAPSE was investigated in a similar fashion to that used for conventional M-mode. Two to three measures of TAPSE were taken and the results averaged. In thirty women, measurements were performed by two observers and inter- and intraobserver variation were calculated. RESULTS: We examined 341 fetuses at GA 20-39 weeks. Conventional M-mode f-TAPSE values ranged from a mean of 3.6 (± 1.1) mm at 21 weeks to a mean of 8.6 (± 1.5) mm at 39 weeks. In 45 cases we were unable to perform conventional M-mode ultrasound because of fetal lie; in eight cases STIC volumes were found in post-processing to be unsuitable for analysis. STIC f-TAPSE values ranged from a mean of 4.2 (± 1.4) mm at 21 weeks to a mean of 8.3 (± 1.5) mm at 39 weeks. Scatterplots of f-TAPSE measures obtained with conventional M-mode and with STIC M-mode were created vs GA and estimated fetal weight (EFW). For both modalities, f-TAPSE increased linearly with GA and with EFW. Good correlation was found between the two methods (Pearson's R(2) = 0.904). No significant difference was found in mean or variance of the distributions or slopes of the regression equations. Inter- and intraobserver variation (intraclass correlation coefficient) in conventional M-mode and STIC M-mode f-TAPSE measures were 0.94 and 0.97, respectively. CONCLUSION: F-TAPSE in normal fetuses increases over the course of gestation and correlates to EFW. F-TAPSE measurement is easy to perform and available on all ultrasound machines; STIC f-TAPSE is possible on machines with STIC capability and produces similar measures with a greater success rate. We suggest the addition of f-TAPSE measurement to fetal right cardiac function evaluation.


Asunto(s)
Corazón Fetal/fisiología , Válvula Tricúspide/fisiología , Función Ventricular Derecha/fisiología , Adulto , Ecocardiografía , Femenino , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/embriología , Edad Gestacional , Humanos , Edad Materna , Movimiento/fisiología , Variaciones Dependientes del Observador , Embarazo , Estándares de Referencia , Análisis Espacio-Temporal , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/embriología , Ultrasonografía Prenatal/métodos
17.
Ultrasound Obstet Gynecol ; 42(2): 140-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23239522

RESUMEN

OBJECTIVES: To present a systematic approach for evaluating the fetal pharynx and larynx based on two- and three-dimensional ultrasound (2D-US and 3D-US) modalities, describing the sonographic appearance and function of the fetal upper respiratory tract and measuring the anatomical components of the pharynx and larynx. METHODS: Gravidae presenting from the late first trimester to mid-gestation for routine booked examinations with structurally normal singleton fetuses of confirmed gestational age were enrolled. Transabdominal 2D-US was performed for anatomical and functional evaluation of the pharynx and larynx. Color Doppler was used to show fluid motion in the target area. 3D-US (Voluson® E6 with RAB-4-8-D transducer) scans of the fetal neck were acquired during fetal quiescence and in the absence of movements of the pharynx and larynx. Multiplanar reconstruction (MPR) in post-processing allowed adjustment of the volume to obtain the coronal plane. After a learning period to understand the sonographic anatomy of the target area, we measured the pharynx width and height, the upper, middle and lower larynx width and the larynx height. Render mode was applied for spatial evaluation of the target area. We developed a new methodological approach for structured evaluation of the fetal pharynx and larynx based on five spatial planes: posterior and anterior coronal planes and high, mid and low axial planes. RESULTS: We examined 582 fetuses during the second trimester of pregnancy; target anatomy was imaged successfully in 218 patients at 11-24 gestational weeks. Acquisition added approximately 1 min to examination time. Rates of successful visualization and measurements increased significantly as pregnancy progressed, being 23% (46/194) at 11-13 weeks, 29% (69/240) at 14-16 weeks, 35% (18/51) at 17-19 weeks and 88% (85/97) at 20-24 weeks (P < 0.01). Pharynx components identified were: the sphenoid bone, pterygoid processes, constrictor muscles, piriform recesses and uvula. Larynx components identified were: the epiglottis, aryepiglottic folds, corniculate cartilages, arytenoid cartilages, cricoid cartilage, thyroid cartilage and vocal cords. MPR showed the biconcave shape of the uvula, which may explain the 'equals sign' observed on 2D-US. We observed the bilateral mode of movements of the constrictor muscles, aryepiglottic folds and vocal cords, and the bidirectional fluid jet flows through the larynx. Scatterplots of measured structures vs gestational age were created. Pharynx width ranged from 0.11 to 0.93 (mean ± SD, 0.48 ± 0.17) cm; pharynx height ranged from 0.23 to 2.01 (mean ± SD, 0.94 ± 0.34) cm; upper larynx width ranged from 0.04 to 0.37 (mean ± SD, 0.15 ± 0.07) cm; middle larynx width ranged from 0.08 to 0.77 (mean ± SD, 0.34 ± 0.16) cm; lower larynx width ranged from 0.05 to 0.64 (mean ± SD, 0.24 ± 0.11) cm; and larynx height ranged from 0.20 to 1.83 (mean ± SD, 0.71 ± 0.31) cm. All measurements were positively correlated with gestational age. CONCLUSIONS: The fetal larynx and pharynx can be evaluated thoroughly using 2D- and 3D-US modalities. Knowledge of normal anatomy, function and biometry may prove useful in the evaluation of anatomical or functional pathology involving the fetal upper respiratory tract. Recognition of anatomical anomalies may enhance fetal intervention such as balloon placement in cases of diaphragmatic hernia.


Asunto(s)
Laringe/embriología , Faringe/embriología , Desarrollo Fetal/fisiología , Edad Gestacional , Humanos , Imagenología Tridimensional , Enfermedades de la Laringe/diagnóstico por imagen , Laringe/diagnóstico por imagen , Neoplasias Faríngeas/diagnóstico por imagen , Faringe/diagnóstico por imagen , Estudios Prospectivos , Teratoma/ultraestructura , Fístula Traqueoesofágica/diagnóstico por imagen , Ultrasonografía Prenatal/métodos
19.
Ultrasound Obstet Gynecol ; 39(1): 83-90, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21845740

RESUMEN

OBJECTIVE: Three-dimensional transperineal sonography (3D-TPS) performed in women following third- or fourth-degree intrapartum tears repaired with the overlapping technique demonstrates characteristic signs. The aim of this study was to investigate the correlation of these signs with clinical complaints of incontinence. METHODS: This was a prospective observational study. Sixty primiparous women underwent 3D-TPS 3-42 (mean, 10.6) months after surgical repair of third- or fourth-degree postpartum sphincter tears with the overlapping technique and were evaluated for clinical degree of incontinence using the St Mark's Incontinence Score (SMIS) questionnaire. The following signs were assessed on 3D-TPS: interruption of the internal anal sphincter or external anal sphincter, 'half moon' sign, changes in the mucosal folds and thickening of the external anal sphincter in the area of sphincter repair. As a comparison group, 27 primiparous women after normal vaginal delivery, without clinically recognized anal sphincter tears, were evaluated similarly, 3-37 (mean, 9.9) months postpartum. RESULTS: Abnormal sonographic signs were apparent in 35 (58.3%) of 60 women in the study group, and 39 (65%) of 60 had some clinical complaints of incontinence 3-42 months after delivery, most of a mild degree. Higher SMIS results were found in women of the study group than in those of the comparison group (mean (SD) 2.80 (0.481) vs. 1.15 (0.365); P = 0.018). The rates of incontinence were similar between the women in the study group with normal ultrasound findings and the women in the comparison group (9/25 vs. 10/27; relative risk (RR) = 0.97, 95% CI, 0.47-1.97). CONCLUSIONS: Sonographic signs of anal sphincter tear and repair had disappeared at follow-up examination in almost half of the patients, and therefore this examination should be deferred from the early postpartum period. A substantial proportion of women report some complaint of incontinence after sphincter repair, most of a slight degree. Such complaints are associated with abnormal 3D-TPS findings at follow up, while in women with a normal 3D-TPS scan the rate of incontinence complaints is similar to that in women after normal delivery.


Asunto(s)
Canal Anal/diagnóstico por imagen , Endosonografía/métodos , Incontinencia Fecal/diagnóstico por imagen , Imagenología Tridimensional , Laceraciones/diagnóstico por imagen , Complicaciones del Trabajo de Parto/diagnóstico por imagen , Perineo/diagnóstico por imagen , Adulto , Canal Anal/lesiones , Canal Anal/cirugía , Parto Obstétrico/efectos adversos , Incontinencia Fecal/etiología , Incontinencia Fecal/cirugía , Femenino , Humanos , Laceraciones/complicaciones , Laceraciones/cirugía , Complicaciones del Trabajo de Parto/etiología , Complicaciones del Trabajo de Parto/cirugía , Paridad , Perineo/lesiones , Perineo/cirugía , Embarazo , Estudios Prospectivos , Encuestas y Cuestionarios
20.
Ultrasound Obstet Gynecol ; 39(2): 131-44, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21611999

RESUMEN

The purpose of this review is to evaluate the current modalities available for the assessment of fetal cardiac function. The unique anatomy and physiology of the fetal circulation are described, with reference to the difference between in-utero and ex-utero life. M-mode, early/atrial ratio, myocardial performance index, three-dimensional and four-dimensional ultrasound, tissue Doppler including strain and strain rate, speckle tracking, magnetic resonance imaging and venous flow assessment are described. The modalities are analyzed from the perspective of the clinician and certain questions are posed. Does the modality assess systolic function, diastolic function or both? Is it applicable to both ventricles? Does it require extensive post-processing or additional hardware, or does it make use of technology already available to the average practitioner? The reproducibility and reliability of the techniques are evaluated, with reference to their utility in clinical decision-making. Finally, directions for future research are proposed.


Asunto(s)
Ecocardiografía Doppler , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiología , Contracción Miocárdica , Volumen Sistólico , Ecocardiografía Tridimensional , Corazón Fetal/anatomía & histología , Corazón Fetal/patología , Corazón Fetal/fisiopatología , Humanos , Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda