Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Clin Chem ; 70(3): 497-505, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38102065

RESUMEN

BACKGROUND: Cardiac troponin measurements are indispensable for the diagnosis of myocardial infarction and provide useful information for long-term risk prediction of cardiovascular disease. Accelerated diagnostic pathways prevent unnecessary hospital admission, but require reporting cardiac troponin concentrations at low concentrations that are sometimes below the limit of quantification. Whether analytical imprecision at these concentrations contributes to misclassification of patients is debated. CONTENT: The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) provides evidence-based educational statements on analytical and clinical aspects of cardiac biomarkers. This mini-review discusses how the reporting of low concentrations of cardiac troponins impacts on whether or not assays are classified as high-sensitivity and how analytical performance at low concentrations influences the utility of troponins in accelerated diagnostic pathways. Practical suggestions are made for laboratories regarding analytical quality assessment of cardiac troponin results at low cutoffs, with a particular focus on accelerated diagnostic pathways. The review also discusses how future use of cardiac troponins for long-term prediction or management of cardiovascular disease may require improvements in analytical quality. SUMMARY: Clinical guidelines recommend using cardiac troponin concentrations as low as the limit of detection of the assay to guide patient care. Laboratories, manufacturers, researchers, and external quality assessment providers should extend analytical performance monitoring of cardiac troponin assays to include the concentration ranges applicable in these pathways.


Asunto(s)
Bioensayo , Infarto del Miocardio , Humanos , Química Clínica , Hospitalización , Infarto del Miocardio/diagnóstico , Troponina
2.
Eur Heart J ; 44(30): 2846-2858, 2023 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-37350492

RESUMEN

AIMS: Whether a single cardiac troponin measurement can safely rule out myocardial infarction in patients presenting within a few hours of symptom onset is uncertain. The study aim was to assess the performance of troponin in early presenters. METHODS AND RESULTS: In patients with possible myocardial infarction, the diagnostic performance of a single measurement of high-sensitivity cardiac troponin I at presentation was evaluated and externally validated in those tested ≤3, 4-12, and >12 h from symptom onset. The limit-of-detection (2 ng/L), rule-out (5 ng/L), and sex-specific 99th centile (16 ng/L in women; 34 ng/L in men) thresholds were compared. In 41 103 consecutive patients [60 (17) years, 46% women], 12 595 (31%) presented within 3 h, and 3728 (9%) had myocardial infarction. In those presenting ≤3 h, a threshold of 2 ng/L had greater sensitivity and negative predictive value [99.4% (95% confidence interval 99.2%-99.5%) and 99.7% (99.6%-99.8%)] compared with 5 ng/L [96.5% (96.2%-96.8%) and 99.3% (99.1%-99.4%)]. In those presenting ≥3 h, the sensitivity and negative predictive value were similar for both thresholds. The sensitivity of the 99th centile was low in early and late presenters at 71.4% (70.6%-72.2%) and 92.5% (92.0%-93.0%), respectively. Findings were consistent in an external validation cohort of 7088 patients. CONCLUSION: In early presenters, a single measurement of high-sensitivity cardiac troponin I below the limit of detection may facilitate the safe rule out of myocardial infarction. The 99th centile should not be used to rule out myocardial infarction at presentation even in those presenting later following symptom onset.


Asunto(s)
Infarto del Miocardio , Troponina I , Masculino , Humanos , Femenino , Biomarcadores , Infarto del Miocardio/diagnóstico , Valor Predictivo de las Pruebas , Troponina T , Servicio de Urgencia en Hospital
3.
Circulation ; 146(7): 569-581, 2022 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-35775423

RESUMEN

The 2021 American Heart Association/American College of Cardiology/American Society of Echocardiography/American College of Chest Physicians/Society for Academic Emergency Medicine/Society of Cardiovascular Computed Tomography/Society for Cardiovascular Magnetic Resonance guidelines for the evaluation and diagnosis of acute chest pain make important recommendations that include the recognition of high-sensitivity cardiac troponin (hs-cTn) as the preferred biomarker, endorsement of 99th percentile upper reference limits to define myocardial injury, and the use of clinical decision pathways, as well as acknowledgment of the uniqueness of women and other patient subsets. Details on how to integrate hs-cTn into clinical practice are less extensively addressed. Clinicians should be aware of some of the analytical aspects related to hs-cTn assays regarding the limit of detection and the limit of quantitation and how they are used clinically, especially for the single sample strategy to rule out acute myocardial infarction. Likewise, it is important for clinicians to understand issues related to the derivation of the 99th percentile upper reference limit; the value of sex-specific 99th percentile upper reference limits; how to use changing concentrations (deltas) to facilitate diagnosis and risk stratification of patients with suspected acute coronary syndrome, including the differentiation of acute from chronic myocardial injury; and how to best integrate the use of hs-cTn with clinical decision pathways. With the use of hs-cTn, conditions such as type 2 myocardial infarction become more common, whereas others such as unstable angina become less frequent but still occur. Sections relating to these issues are included.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Síndrome Coronario Agudo/diagnóstico , Angina Inestable/diagnóstico , Biomarcadores , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/etiología , Femenino , Humanos , Masculino , Infarto del Miocardio/diagnóstico , Troponina T
4.
Circulation ; 144(7): 528-538, 2021 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-34167318

RESUMEN

BACKGROUND: Although the 99th percentile is the recommended diagnostic threshold for myocardial infarction, some guidelines also advocate the use of higher troponin thresholds to rule in myocardial infarction at presentation. It is unclear whether the magnitude or change in troponin concentration can differentiate causes of myocardial injury and infarction in practice. METHODS: In a secondary analysis of a multicenter randomized controlled trial, we identified 46 092 consecutive patients presenting with suspected acute coronary syndrome without ST-segment-elevation myocardial infarction. High-sensitivity cardiac troponin I concentrations at presentation and on serial testing were compared between patients with myocardial injury and infarction. The positive predictive value and specificity were determined at the sex-specific 99th percentile upper reference limit and rule-in thresholds of 64 ng/L and 5-fold of the upper reference limit for a diagnosis of type 1 myocardial infarction. RESULTS: Troponin was above the 99th percentile in 8188 patients (18%). The diagnosis was type 1 or type 2 myocardial infarction in 50% and 14% and acute or chronic myocardial injury in 20% and 16%, respectively. Troponin concentrations were similar at presentation in type 1 (median [25th-75th percentile] 91 [30-493] ng/L) and type 2 (50 [22-147] ng/L) myocardial infarction and in acute (50 [26-134] ng/L) and chronic (51 [31-130] ng/L) myocardial injury. The 99th percentile and rule-in thresholds of 64 ng/L and 5-fold upper reference limit gave a positive predictive value of 57% (95% CI, 56%-58%), 59% (58%-61%), and 62% (60%-64%) and a specificity of 96% (96%-96%), 96% (96%-96%), and 98% (97%-98%), respectively. The absolute, relative, and rate of change in troponin concentration were highest in patients with type 1 myocardial infarction (P<0.001 for all). Discrimination improved when troponin concentration and change in troponin were combined compared with troponin concentration at presentation alone (area under the curve, 0.661 [0.642-0.680] versus 0.613 [0.594-0.633]). CONCLUSIONS: Although we observed important differences in the kinetics, cardiac troponin concentrations at presentation are insufficient to distinguish type 1 myocardial infarction from other causes of myocardial injury or infarction in practice and should not guide management decisions in isolation. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01852123.


Asunto(s)
Biomarcadores , Lesiones Cardíacas/diagnóstico , Lesiones Cardíacas/metabolismo , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/metabolismo , Miocardio/metabolismo , Troponina/sangre , Anciano , Diagnóstico Diferencial , Femenino , Lesiones Cardíacas/etiología , Humanos , Cinética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/etiología , Infarto del Miocardio con Elevación del ST/metabolismo , Sensibilidad y Especificidad , Troponina I/sangre , Troponina I/metabolismo
5.
Circulation ; 143(23): 2214-2224, 2021 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-33752439

RESUMEN

BACKGROUND: High-sensitivity cardiac troponin assays enable myocardial infarction to be ruled out earlier, but the safety and efficacy of this approach is uncertain. We investigated whether an early rule-out pathway is safe and effective for patients with suspected acute coronary syndrome. METHODS: We performed a stepped-wedge cluster randomized controlled trial in the emergency departments of 7 acute care hospitals in Scotland. Consecutive patients presenting with suspected acute coronary syndrome between December 2014 and December 2016 were included. Sites were randomized to implement an early rule-out pathway where myocardial infarction was excluded if high-sensitivity cardiac troponin I concentrations were <5 ng/L at presentation. During a previous validation phase, myocardial infarction was ruled out when troponin concentrations were <99th percentile at 6 to 12 hours after symptom onset. The coprimary outcome was length of stay (efficacy) and myocardial infarction or cardiac death after discharge at 30 days (safety). Patients were followed for 1 year to evaluate safety and other secondary outcomes. RESULTS: We enrolled 31 492 patients (59±17 years of age [mean±SD]; 45% women) with troponin concentrations <99th percentile at presentation. Length of stay was reduced from 10.1±4.1 to 6.8±3.9 hours (adjusted geometric mean ratio, 0.78 [95% CI, 0.73-0.83]; P<0.001) after implementation and the proportion of patients discharged increased from 50% to 71% (adjusted odds ratio, 1.59 [95% CI, 1.45-1.75]). Noninferiority was not demonstrated for the 30-day safety outcome (upper limit of 1-sided 95% CI for adjusted risk difference, 0.70% [noninferiority margin 0.50%]; P=0.068), but the observed differences favored the early rule-out pathway (0.4% [57/14 700] versus 0.3% [56/16 792]). At 1 year, the safety outcome occurred in 2.7% (396/14 700) and 1.8% (307/16 792) of patients before and after implementation (adjusted odds ratio, 1.02 [95% CI, 0.74-1.40]; P=0.894), and there were no differences in hospital reattendance or all-cause mortality. CONCLUSIONS: Implementation of an early rule-out pathway for myocardial infarction reduced length of stay and hospital admission. Although noninferiority for the safety outcome was not demonstrated at 30 days, there was no increase in cardiac events at 1 year. Adoption of this pathway would have major benefits for patients and health care providers. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03005158.


Asunto(s)
Infarto del Miocardio/patología , Troponina I/sangre , Adulto , Anciano , Biomarcadores/sangre , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Oportunidad Relativa , Alta del Paciente , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Resultado del Tratamiento
6.
Kidney Int ; 102(1): 149-159, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35271932

RESUMEN

The benefit and utility of high-sensitivity cardiac troponin (hs-cTn) in the diagnosis of myocardial infarction in patients with kidney impairment is unclear. Here, we describe implementation of hs-cTnI testing on the diagnosis, management, and outcomes of myocardial infarction in patients with and without kidney impairment. Consecutive patients with suspected acute coronary syndrome enrolled in a stepped-wedge, cluster-randomized controlled trial were included in this pre-specified secondary analysis. Kidney impairment was defined as an eGFR under 60mL/min/1.73m2. The index diagnosis and primary outcome of type 1 and type 4b myocardial infarction or cardiovascular death at one year were compared in patients with and without kidney impairment following implementation of hs-cTnI assay with 99th centile sex-specific diagnostic thresholds. Serum creatinine concentrations were available in 46,927 patients (mean age 61 years; 47% women), of whom 9,080 (19%) had kidney impairment. hs-cTnIs were over 99th centile in 46% and 16% of patients with and without kidney impairment. Implementation increased the diagnosis of type 1 infarction from 12.4% to 17.8%, and from 7.5% to 9.4% in patients with and without kidney impairment (both significant). Patients with kidney impairment and type 1 myocardial infarction were less likely to undergo coronary revascularization (26% versus 53%) or receive dual anti-platelets (40% versus 68%) than those without kidney impairment, and this did not change post-implementation. In patients with hs-cTnI above the 99th centile, the primary outcome occurred twice as often in those with kidney impairment compared to those without (24% versus 12%, hazard ratio 1.53, 95% confidence interval 1.31 to 1.78). Thus, hs-cTnI testing increased the identification of myocardial injury and infarction but failed to address disparities in management and outcomes between those with and without kidney impairment.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Insuficiencia Renal , Troponina I , Biomarcadores , Creatinina , Femenino , Humanos , Riñón , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Insuficiencia Renal/sangre , Insuficiencia Renal/complicaciones , Insuficiencia Renal/diagnóstico , Troponina I/sangre , Troponina T
7.
Emerg Med J ; 39(11): 861-866, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35017187

RESUMEN

Methods to improve the safety, accuracy and efficiency of assessment of patients with suspected acute coronary symptoms have occupied decades of study and have supported significant changes in clinical practice. Much of the progress is reliant on results of laboratory-based high-sensitivity cardiac troponin assays that can detect low concentrations with high precision. Until recently, point-of-care (POC) platforms were unable to perform with similar analytical precision as laboratory-based assays, and recommendations for their use in accelerated assessment strategies for patients with suspected acute coronary syndrome has been limited. As POC assays can provide troponin results within 20 min, and can be used proximate to patient care, improvements in the efficiency of assessment of patients with suspected acute coronary syndrome is possible, particularly with new high-sensitivity assays.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Síndrome Coronario Agudo/diagnóstico , Infarto del Miocardio/diagnóstico , Servicio de Urgencia en Hospital , Biomarcadores , Troponina , Pruebas en el Punto de Atención , Sistemas de Atención de Punto
8.
Circulation ; 141(3): 161-171, 2020 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-31587565

RESUMEN

BACKGROUND: The introduction of more sensitive cardiac troponin assays has led to increased recognition of myocardial injury in acute illnesses other than acute coronary syndrome. The Universal Definition of Myocardial Infarction recommends high-sensitivity cardiac troponin testing and classification of patients with myocardial injury based on pathogenesis, but the clinical implications of implementing this guideline are not well understood. METHODS: In a stepped-wedge cluster randomized, controlled trial, we implemented a high-sensitivity cardiac troponin assay and the recommendations of the Universal Definition in 48 282 consecutive patients with suspected acute coronary syndrome. In a prespecified secondary analysis, we compared the primary outcome of myocardial infarction or cardiovascular death and secondary outcome of noncardiovascular death at 1 year across diagnostic categories. RESULTS: Implementation increased the diagnosis of type 1 myocardial infarction by 11% (510/4471), type 2 myocardial infarction by 22% (205/916), and acute and chronic myocardial injury by 36% (443/1233) and 43% (389/898), respectively. Compared with those without myocardial injury, the rate of the primary outcome was highest in those with type 1 myocardial infarction (cause-specific hazard ratio [HR] 5.64 [95% CI, 5.12-6.22]), but was similar across diagnostic categories, whereas noncardiovascular deaths were highest in those with acute myocardial injury (cause specific HR 2.65 [95% CI, 2.33-3.01]). Despite modest increases in antiplatelet therapy and coronary revascularization after implementation in patients with type 1 myocardial infarction, the primary outcome was unchanged (cause specific HR 1.00 [95% CI, 0.82-1.21]). Increased recognition of type 2 myocardial infarction and myocardial injury did not lead to changes in investigation, treatment or outcomes. CONCLUSIONS: Implementation of high-sensitivity cardiac troponin assays and the recommendations of the Universal Definition of Myocardial Infarction identified patients at high-risk of cardiovascular and noncardiovascular events but was not associated with consistent increases in treatment or improved outcomes. Trials of secondary prevention are urgently required to determine whether this risk is modifiable in patients without type 1 myocardial infarction. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01852123.


Asunto(s)
Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Troponina I/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/clasificación , Valor Predictivo de las Pruebas , Medición de Riesgo
9.
Clin Chem ; 67(1): 70-78, 2021 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-33279984

RESUMEN

BACKGROUND: The primary role of the International Federation of Clinical Chemistry (IFCC) Committee on Clinical Application of Cardiac Bio-Markers (C-CB) is to provide educational materials about cardiac biomarker use, emphasizing high-sensitivity cardiac troponin assays. CONTENT: This mini-review, regarding high-sensitivity cardiac and point-of-care troponin assays, addresses 1) new IFCC C-CB/AACC Academy laboratory practice recommendations; 2) new and updated concepts from the Fourth Universal Definition of Myocardial Infarction; 3) the role of point-of-care assays in practice and research; 4) regulatory challenges concerning point-of-care assays; e) testing in the COVID-19 world. SUMMARY: Implementation of high-sensitivity cardiac troponin assays makes a difference now and into the future in clinical practice and research. Providing point-of-care high-sensitivity cardiac troponin assays and optimizing studies to allow clearance of these assays by regulatory agencies, in a timely fashion, may provide improved patient management and outcomes.


Asunto(s)
Pruebas de Química Clínica , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto , Troponina I/sangre , Troponina T/sangre , Biomarcadores/sangre , COVID-19/epidemiología , COVID-19/virología , Humanos , Límite de Detección , Infarto del Miocardio/sangre , SARS-CoV-2/aislamiento & purificación
10.
Clin Chem ; 67(1): 237-244, 2021 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-33418577

RESUMEN

BACKGROUND: We assessed the accuracy and clinical effectiveness of high-sensitivity cardiac troponin (hs-cTn) assays for early rule-out of non-ST-segment elevation myocardial infarction (NSTEMI) in adults presenting with acute chest pain. METHODS: Sixteen databases were searched to September 2019. Review methods followed published guidelines. The bivariate model was used to estimate summary sensitivity and specificity with 95% confidence intervals for meta-analyses involving 4 or more studies, otherwise random-effects logistic regression was used. RESULTS: Thirty-seven studies (124 publications) were included in the review. The hs-cTn test strategies evaluated in the included studies were defined by the combination of 4 factors (assay, number of tests, timing of tests, and threshold concentration or change in concentration between tests). Clinical opinion indicated a minimum acceptable sensitivity of 97%. A single test at presentation using a threshold at or near the assay limit of detection could reliably rule-out NSTEMI for a range of hs-cTn assays. Serial testing strategies, which include an immediate rule-out step, increased the proportion ruled out without loss of sensitivity. Finally, serial testing strategies without an immediate rule-out step had excellent sensitivity and specificity, but at the expense of the option for immediate patient discharge. CONCLUSION: Test strategies that comprise an initial rule-out step, based on low hs-cTn concentrations at presentation and a minimum symptom duration, and a second step for those not ruled-out that incorporates a small absolute change in hs-cTn at 1, 2, or 3 hours, produce the highest rule-out rates with a very low risk of missed NSTEMI. PROSPERO REGISTRATION: CRD42019154716.


Asunto(s)
Angina de Pecho/sangre , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina I/análisis , Troponina T/análisis , Adulto , Algoritmos , Angina de Pecho/complicaciones , Pruebas Diagnósticas de Rutina/métodos , Humanos , Infarto del Miocardio sin Elevación del ST/sangre , Infarto del Miocardio sin Elevación del ST/complicaciones , Ensayos Clínicos Controlados Aleatorios como Asunto , Sensibilidad y Especificidad
11.
Clin Chem ; 66(9): 1167-1180, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32871000

RESUMEN

BACKGROUND: Concerns exist regarding how the 99th percentile upper reference limit (URL) of cardiac troponin (cTn) is determined and whether it should be derived from normal healthy individuals. CONTENT: The 99th percentile URL of cTn is an important criterion to standardize the diagnosis of myocardial infarction (MI) for clinical, research, and regulatory purposes. Statistical heterogeneity in its calculation exists but recommendations have been proposed. Some negativity has resulted from the fact that with some high-sensitivity (hs) cTn assays, a greater number of increases above the 99th percentile are observed when transitioning from a contemporary assay. Increases reflect acute or chronic myocardial injury and provide valuable diagnostic and prognostic information. The etiology of increases can sometimes be difficult to determine, making a specific treatment approach challenging. For those reasons, some advocate higher cutoff concentrations. This approach can contribute to missed diagnoses. Contrary to claims, neither clinical or laboratory guidelines have shifted away from the 99th percentile. To support the diagnosis of acute MI, the 99th percentile URL remains the best-established approach given the absence of cTn assay standardization. Importantly, risk stratification algorithms using hs-cTn assays predict the possibility of MI diagnoses established using the 99th percentile. SUMMARY: The 99th percentile of cTn remains the best-established criterion for the diagnosis of acute MI. While not perfect, it is analytically and clinically evidence-based. Until there are robust data to suggest some other approach, staying with the 99th percentile, a threshold that has served the field well for the past 20 years, appears prudent.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Troponina T/sangre , Enfermedad Aguda , Biomarcadores/sangre , Humanos , Infarto del Miocardio/sangre , Valores de Referencia , Troponina I/normas , Troponina T/normas
12.
Emerg Med J ; 37(1): 8-13, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31767674

RESUMEN

OBJECTIVES: To directly compare the diagnostic accuracy of four decision aids (Troponin-only Manchester Acute Coronary Syndromes (T-MACS), History, ECG, Age, Risk factors and Troponin (HEART), Thrombolysis in Myocardial Infarction (TIMI) and Emergency Department Assessment of Chest Pain (EDACS)) used to expedite the early diagnosis of acute coronary syndromes (ACS) in the ED. METHODS: We prospectively included patients who presented to 14 EDs in England (February 2015 to June 2017) with suspected ACS within 12 hours of symptom onset. Data to enable evaluation of the T-MACS, HEART, TIMI and EDACS decision aids (without recalibration) were prospectively collected, blinded to patient outcome. We tested admission blood samples for high-sensitivity cardiac troponin I (hs-cTnI; Siemens ADVIA Centaur). Patients also underwent serial cardiac troponin testing over 3-12 hours. The target condition was an adjudicated diagnosis of acute myocardial infarction (AMI). We also evaluated the incidence of major adverse cardiac events (including death, AMI or coronary revascularisation) at 30 days. Diagnostic accuracy of each decision aid and hs-cTnI alone (using the limit of quantification cut-off, 3 ng/L) was evaluated by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). RESULTS: Of 999 included patients, 132 (13.2%) had AMI. C-statistics were 0.96 for T-MACS, 0.78 for HEART and 0.69 for TIMI. The sensitivities of T-MACS, HEART, TIMI, EDACS and hs-cTnI <3 ng/L for AMI were 99.2% (95% CI 95.7% to 100.0%), 91.8% (85.0% to 96.2%), 97.5% (92.9% to 99.5%), 96.2% (92.2% to 99.4%) and 99.2% (95.9% to 100.0%), respectively. The respective strategies would have ruled out 46.5%, 34.9%, 19.4%, 48.3% and 28.8% patients. PPVs for the decision aids that identify 'high-risk' patients were 80.4% (T-MACS), 51.9% (TIMI) and 37.2% (HEART). CONCLUSIONS: In this study, T-MACS could rule out AMI in 46.5% patients with 99.2% sensitivity. EDACS could rule out AMI in 48.3% patients with lower sensitivity, although the difference was not statistically significant. The HEART and TIMI scores had lower diagnostic accuracy.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Dolor en el Pecho/diagnóstico , Servicio de Urgencia en Hospital , Troponina I/sangre , Troponina T/sangre , Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/mortalidad , Anciano , Biomarcadores/sangre , Dolor en el Pecho/sangre , Dolor en el Pecho/mortalidad , Técnicas de Apoyo para la Decisión , Diagnóstico Precoz , Electrocardiografía , Inglaterra/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Medición de Riesgo , Sensibilidad y Especificidad
13.
Lancet ; 392(10151): 919-928, 2018 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-30170853

RESUMEN

BACKGROUND: High-sensitivity cardiac troponin assays permit use of lower thresholds for the diagnosis of myocardial infarction, but whether this improves clinical outcomes is unknown. We aimed to determine whether the introduction of a high-sensitivity cardiac troponin I (hs-cTnI) assay with a sex-specific 99th centile diagnostic threshold would reduce subsequent myocardial infarction or cardiovascular death in patients with suspected acute coronary syndrome. METHODS: In this stepped-wedge, cluster-randomised controlled trial across ten secondary or tertiary care hospitals in Scotland, we evaluated the implementation of an hs-cTnI assay in consecutive patients who had been admitted to the hospitals' emergency departments with suspected acute coronary syndrome. Patients were eligible for inclusion if they presented with suspected acute coronary syndrome and had paired cardiac troponin measurements from the standard care and trial assays. During a validation phase of 6-12 months, results from the hs-cTnI assay were concealed from the attending clinician, and a contemporary cardiac troponin I (cTnI) assay was used to guide care. Hospitals were randomly allocated to early (n=5 hospitals) or late (n=5 hospitals) implementation, in which the high-sensitivity assay and sex-specific 99th centile diagnostic threshold was introduced immediately after the 6-month validation phase or was deferred for a further 6 months. Patients reclassified by the high-sensitivity assay were defined as those with an increased hs-cTnI concentration in whom cTnI concentrations were below the diagnostic threshold on the contemporary assay. The primary outcome was subsequent myocardial infarction or death from cardiovascular causes at 1 year after initial presentation. Outcomes were compared in patients reclassified by the high-sensitivity assay before and after its implementation by use of an adjusted generalised linear mixed model. This trial is registered with ClinicalTrials.gov, number NCT01852123. FINDINGS: Between June 10, 2013, and March 3, 2016, we enrolled 48 282 consecutive patients (61 [SD 17] years, 47% women) of whom 10 360 (21%) patients had cTnI concentrations greater than those of the 99th centile of the normal range of values, who were identified by the contemporary assay or the high-sensitivity assay. The high-sensitivity assay reclassified 1771 (17%) of 10 360 patients with myocardial injury or infarction who were not identified by the contemporary assay. In those reclassified, subsequent myocardial infarction or cardiovascular death within 1 year occurred in 105 (15%) of 720 patients in the validation phase and 131 (12%) of 1051 patients in the implementation phase (adjusted odds ratio for implementation vs validation phase 1·10, 95% CI 0·75 to 1·61; p=0·620). INTERPRETATION: Use of a high-sensitivity assay prompted reclassification of 1771 (17%) of 10 360 patients with myocardial injury or infarction, but was not associated with a lower subsequent incidence of myocardial infarction or cardiovascular death at 1 year. Our findings question whether the diagnostic threshold for myocardial infarction should be based on the 99th centile derived from a normal reference population. FUNDING: The British Heart Foundation.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Infarto del Miocardio/diagnóstico , Troponina I/sangre , Síndrome Coronario Agudo/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Valor Predictivo de las Pruebas
14.
Clin Chem Lab Med ; 57(5): 623-632, 2019 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-30530880

RESUMEN

The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) formed a Task Force on the Application of Cardiac Bio-markers (TF-CB) in 2008, re-designated in 2018 as a committee (C-CB), to produce educational materials on cardiac biomarkers. Established in June 2017, definitive tables covering the majority of high-sensitivity, contemporary and point-of-care (POC) cTn assays have been developed by the C-CB and are available on the IFCC website. These tables provide extensive information about assays' analytical characteristics and encompass information on diagnostic discriminants, particularly the 99th percentiles, as provided by the manufacturers.


Asunto(s)
Análisis Químico de la Sangre/estadística & datos numéricos , Pruebas en el Punto de Atención/estadística & datos numéricos , Troponina I/sangre , Troponina T/sangre , Biomarcadores/sangre , Humanos
15.
Clin Chem Lab Med ; 57(5): 633-640, 2019 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-30291783

RESUMEN

Two interferences recently brought to the forefront as patient safety issues include hemolysis (hemoglobin) and biotin (vitamin B7). The International Federation for Clinical Chemistry Committee on Cardiac Biomarkers (IFCC-CB) obtained input from a majority of cTn and NP assay manufacturers to collate information related to high-sensitivity (hs)-cTnI, hs-cTnT, contemporary, and POC cTn assays, and NP assays interferences due to hemolysis and biotin. The information contained in these tables was designed as educational tools to aid laboratory professionals and clinicians in troubleshooting cardiac biomarker analytical results that are discordant with the clinical situation.


Asunto(s)
Análisis Químico de la Sangre/estadística & datos numéricos , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Troponina I/sangre , Troponina T/sangre , Biomarcadores/sangre , Biotina/sangre , Hemólisis/fisiología , Humanos
16.
Lancet ; 386(10012): 2481-8, 2015 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-26454362

RESUMEN

BACKGROUND: Suspected acute coronary syndrome is the commonest reason for emergency admission to hospital and is a large burden on health-care resources. Strategies to identify low-risk patients suitable for immediate discharge would have major benefits. METHODS: We did a prospective cohort study of 6304 consecutively enrolled patients with suspected acute coronary syndrome presenting to four secondary and tertiary care hospitals in Scotland. We measured plasma troponin concentrations at presentation using a high-sensitivity cardiac troponin I assay. In derivation and validation cohorts, we evaluated the negative predictive value of a range of troponin concentrations for the primary outcome of index myocardial infarction, or subsequent myocardial infarction or cardiac death at 30 days. This trial is registered with ClinicalTrials.gov (number NCT01852123). FINDINGS: 782 (16%) of 4870 patients in the derivation cohort had index myocardial infarction, with a further 32 (1%) re-presenting with myocardial infarction and 75 (2%) cardiac deaths at 30 days. In patients without myocardial infarction at presentation, troponin concentrations were less than 5 ng/L in 2311 (61%) of 3799 patients, with a negative predictive value of 99·6% (95% CI 99·3-99·8) for the primary outcome. The negative predictive value was consistent across groups stratified by age, sex, risk factors, and previous cardiovascular disease. In two independent validation cohorts, troponin concentrations were less than 5 ng/L in 594 (56%) of 1061 patients, with an overall negative predictive value of 99·4% (98·8-99·9). At 1 year, these patients had a lower risk of myocardial infarction and cardiac death than did those with a troponin concentration of 5 ng/L or more (0·6% vs 3·3%; adjusted hazard ratio 0·41, 95% CI 0·21-0·80; p<0·0001). INTERPRETATION: Low plasma troponin concentrations identify two-thirds of patients at very low risk of cardiac events who could be discharged from hospital. Implementation of this approach could substantially reduce hospital admissions and have major benefits for both patients and health-care providers. FUNDING: British Heart Foundation and Chief Scientist Office (Scotland).


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Infarto del Miocardio/diagnóstico , Troponina I/sangre , Síndrome Coronario Agudo/sangre , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Escocia , Sensibilidad y Especificidad
19.
Am Heart J ; 169(1): 6-16.e6, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25497242

RESUMEN

BACKGROUND: Multiple studies have evaluated the diagnostic and prognostic performance of conventional troponin (cTn) and high-sensitivity troponin (hs-cTn). We performed a collaborative meta-analysis comparing cTn and hs-cTn for diagnosis of acute myocardial infarction (AMI) and assessment of prognosis in patients with chest pain. METHODS: MEDLINE/PubMed, Cochrane CENTRAL, and EMBASE were searched for studies assessing both cTn and hs-cTn in patients with chest pain. Study authors were contacted and many provided previously unpublished data. RESULTS: From 17 included studies, there were 8,644 patients. Compared with baseline cTn, baseline hs-cTn had significantly greater sensitivity (0.884 vs 0.749, P < .001) and negative predictive value (NPV; 0.964 vs 0.935, P < .001), whereas specificity (0.816 vs 0.938, P < .001) and positive predictive value (0.558 vs 0.759, P < .001) were significantly reduced. Based on summary receiver operating characteristic curves, test performance for the diagnosis of AMI was not significantly different between baseline cTn and hs-cTn (0.90 [95% CI 0.85-0.95] vs 0.92 [95% CI 0.90-0.94]). In a subanalysis of 6 studies that alternatively defined AMI based on hs-cTn, cTn had lower sensitivity (0.666, P < .001) and NPV (0.906, P < .001). Elevation of baseline hs-cTn, but negative baseline cTn, was associated with increased risk of death or nonfatal myocardial infarction during follow-up (P < .001) compared with both negative. CONCLUSION: High-sensitivity troponin has significantly greater early sensitivity and NPV for the diagnosis of AMI at the cost of specificity and positive predictive value, which may enable early rule in/out of AMI in patients with chest pain. Baseline hs-cTn elevation in the setting of negative cTn is also associated with increased nonfatal myocardial infarction or death during follow-up.


Asunto(s)
Dolor en el Pecho/sangre , Infarto del Miocardio/diagnóstico , Troponina/sangre , Dolor en el Pecho/etiología , Humanos , Infarto del Miocardio/mortalidad , Pronóstico , Curva ROC , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda