Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
Clin Radiol ; 79(9): e1126-e1133, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38866676

RESUMEN

AIM: Percutaneous radiofrequency ablation (RFA) is a standard treatment for small-HCC (<3 cm). However, some features such as proximity to intrahepatic vascular structures (perivascular location) seem to be related to short- and long-term outcomes. The aims of the study were to investigate the features related to ablation success and local tumor progression (LTP) in patients submitted to percutaneous ablation for perivascular-HCC. MATERIALS AND METHODS: From January 2010 to May 2021, 132 perivascular-HCC nodules ablated with US-guided single probe percutaneous RFA were retrospectively analyzed. Univariate analysis and multivariable Cox regression model were used to identify factors that were independently related to ablation success and LTP-free survival. RESULTS: The overall ablation success rate was 71.9% (n=95). Morbidity and mortality rates were 4.0% and 0.0%. The features related to ablation success: nodule size (≤20 mm vs. >20 mm) (OR 2.442, p=0.031), major vascular structures diameter (3-5 mm vs ≥ 5 mm) (OR 2.167, p=0.037) and liver parenchyma (cirrhosis vs no-cirrhosis) (OR 2.373, p=0.033). The following features resulted independently related to better LTP-free survival: nodule size ≤20 mm (HR 2.802, p=0.003), proximity to glissonean pedicles (HR 1.677, p=0.028), and major vascular structure diameter <5 mm (HR 1.987, p=0.041). CONCLUSIONS: Perivascular location confirmed to be a difficult and unfavorable indication for percutaneous ablation for HCC nodules. However, perivascular nodules not suitable for surgery with low-risk features (size <20 mm, proximity to glissonian pedicles and vascular diameter <5 mm) may be treated with RFA with satisfactory outcomes.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Resultado del Tratamiento , Anciano , Hígado/irrigación sanguínea , Hígado/cirugía , Hígado/diagnóstico por imagen , Ablación por Radiofrecuencia/métodos , Ablación por Catéter/métodos , Ultrasonografía Intervencional/métodos , Adulto
2.
Transfus Apher Sci ; 62(5): 103752, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37355441

RESUMEN

INTRODUCTION: Erythrocytapheresis, an apheresis treatment which selectively removes red blood cells, is an alternative to therapeutic phlebotomy, over which it has several advantages. Actually there is a high degree of variability in the use of this treatment. This prompted SIdEM (Italian Society of Hemapheresis and Cell Manipulation) to conduct a survey on the use of erythrocytapheresis in the Italian Transfusion Services. The purpose is to monitor this activity in the treatment of Polycythemia Vera (pv), secondary erythrocytosis and hemochromatosis. MATERIALS AND METHODS: A data collection file was sent to the SIdEM regional delegates who, in turn, involved the Transfusion Centers in the areas they cover. The data collected were processed on a Microsoft Excel spreadsheet. RESULTS: 75 centers from 14 Italian regions responded to the Survey: 36 centers (48 %) use erythrocytapheresis (35 centers perform therapeutic apheresis and 1 center only donor apheresis), 39 centers (52 %) do not (15 centers perform therapeutic apheresis, 18 centers only donor apheresis and 6 centers do not perform either therapeutic apheresis or donor apheresis). Although most centers have a substantially uniform attitude concerning the indications for which erythrocytapheresis is used, the survey shows that there are still differences more evident in the treatment of secondary erythrocytosis than in the treatment of pv or hemochromatosis. CONCLUSIONS: This survey has been useful to document the current Italian reality and to raise awareness about the need for improvement in optimizing and standardizing the use of a therapy with a great potential to exploit properly.


Asunto(s)
Eliminación de Componentes Sanguíneos , Hemocromatosis , Policitemia Vera , Policitemia , Humanos , Policitemia/terapia , Policitemia Vera/terapia , Hemocromatosis/terapia , Flebotomía , Italia
3.
Br J Surg ; 105(13): 1825-1834, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30106195

RESUMEN

BACKGROUND: The association between risk of pancreatic cancer and a dilated main pancreatic duct (MPD) in intraductal papillary mucinous neoplasm (IPMN) is debated. The aim of this study was to assess the role of MPD size in predicting pancreatic cancer in resected IPMNs and those kept under surveillance. METHODS: All patients with IPMN referred to the Pancreas Institute, University of Verona Hospital Trust, from 2006 to 2016 were included. The primary endpoint was the occurrence of malignancy detected at surgery or during follow-up. RESULTS: The final cohort consisted of 1688 patients with a median follow-up of 60 months. Main pancreatic duct dilatation was associated with other features of malignancy in both the resected and surveillance groups. In patients who underwent resection, only a MPD of at least 10 mm was an independent predictor of malignancy. In patients kept under surveillance, MPD dilatation was not associated with malignancy. Fifteen of 71 patients (21 per cent) with malignancy in the resection cohort had a dilated MPD alone, whereas only one of 30 (3 per cent) under surveillance with MPD dilatation alone developed malignancy. Patients with a dilated MPD and other worrisome features had an increased 5-year cumulative incidence of malignancy compared with those with a non-dilated duct (11 versus 1·2 per cent; P < 0·001); however, the risk of malignancy was not significantly increased in patients with a dilated MPD alone (4 versus 1·2 per cent; P = 0·448). CONCLUSION: In patients under surveillance, a dilated MPD alone was not associated with an increased incidence of malignancy in IPMN.


Asunto(s)
Conductos Pancreáticos/patología , Neoplasias Intraductales Pancreáticas/patología , Neoplasias Pancreáticas/patología , Anciano , Dilatación Patológica/mortalidad , Dilatación Patológica/patología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Neoplasias Intraductales Pancreáticas/mortalidad , Neoplasias Intraductales Pancreáticas/cirugía , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Espera Vigilante
4.
Ultraschall Med ; 37(4): 412-20, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27490463

RESUMEN

The fifth section of the Guidelines on Interventional Ultrasound (INVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) assesses the evidence for all the categories of endoscopic ultrasound-guided treatment reported to date. Celiac plexus neurolysis and block, vascular intervention, drainage of fluid collections, drainage of biliary and pancreatic ducts, and experimental tumor ablation techniques are discussed. For each topic, all current evidence has been extensively analyzed and summarized into major recommendations for reader consultation (short version; the long version is published online).


Asunto(s)
Medios de Contraste , Fosfolípidos , Hexafluoruro de Azufre , Ultrasonografía Intervencional , Niño , Aprobación de Drogas , Europa (Continente) , Humanos , Sociedades Médicas , Estados Unidos , United States Food and Drug Administration
5.
Ultraschall Med ; 37(2): E33-76, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26515966

RESUMEN

The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-guided sampling. Endoscopic ultrasound combines the most advanced high-resolution ultrasound imaging of lesions within the wall and in the vicinity of the gastrointestinal tract and safe and effective fine needle based tissue acquisition from these lesions. The guideline addresses the indications, contraindications, techniques, adverse events, training and clinical impact of EUS-guided sampling. Advantages and drawbacks are weighed in comparison with image-guided percutaneous biopsy. Based on the most current evidence, clinical practice recommendations are given for crucial preconditions and steps of EUS-guided sampling as well as for safe performance. Additionally, the guideline deals with the principles and reliability of cytopathological reporting in endoscopic ultrasound-guided sampling (long version).


Asunto(s)
Biopsia con Aguja , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Sociedades Médicas , Ultrasonografía Intervencional , Biopsia con Aguja/instrumentación , Biopsia con Aguja/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Diseño de Equipo , Europa (Continente) , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados , Ultrasonografía Intervencional/instrumentación , Ultrasonografía Intervencional/métodos
6.
Ultraschall Med ; 37(4): 77-99, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26632995

RESUMEN

The fifth section of the Guidelines on Interventional Ultrasound (INVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) assesses the evidence for all the categories of endoscopic ultrasound-guided treatment reported to date. Celiac plexus neurolysis and block, vascular intervention, drainage of fluid collections, drainage of biliary and pancreatic ducts, and experimental tumor ablation techniques are discussed. For each topic, all current evidence has been extensively analyzed and summarized into major recommendations for reader consultation in clinical practice (long version).


Asunto(s)
Endosonografía , Ultrasonografía Intervencional , Animales , Europa (Continente) , Humanos , Sociedades Médicas
7.
Ultraschall Med ; 37(2): 157-69, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27058434

RESUMEN

The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-guided sampling. Endoscopic ultrasound combines the most advanced high-resolution ultrasound imaging of lesions within the wall and in the vicinity of the gastrointestinal tract and safe and effective fine needle-based tissue acquisition from these lesions. The guideline addresses the indications, contraindications, techniques, adverse events, training and clinical impact of EUS-guided sampling. Advantages and drawbacks are weighed in comparison with image-guided percutaneous biopsy. Based on the most current evidence, clinical practice recommendations are given for crucial preconditions and steps of EUS-guided sampling as well as for safe performance. Additionally, the guideline deals with the principles and reliability of cytopathological reporting in endoscopic ultrasound-guided sampling (short version; the long version is published online).


Asunto(s)
Biopsia con Aguja , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Sociedades Médicas , Ultrasonografía Intervencional , Biopsia con Aguja/instrumentación , Biopsia con Aguja/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Diseño de Equipo , Europa (Continente) , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados , Ultrasonografía Intervencional/instrumentación , Ultrasonografía Intervencional/métodos
8.
Ultraschall Med ; 37(1): E1-E32, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26670019

RESUMEN

The third part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound (INVUS) assesses the evidence for ultrasound-guided and assisted interventions in abdominal treatment procedures. Recommendations for clinical practice are presented covering indications, contraindications, and safe and effective performance of the broad variety of these techniques. In particular, drainage of abscesses and fluid collections, interventional tumor ablation techniques, interventional treatment of symptomatic cysts and echinococcosis, percutaneous transhepatic cholangiography and drainage, percutaneous gastrostomy, urinary bladder drainage, and nephrostomy are addressed (long version).


Asunto(s)
Abdomen/diagnóstico por imagen , Abdomen/cirugía , Medicina Basada en la Evidencia , Sociedades Médicas , Ultrasonografía Intervencional/métodos , Absceso Abdominal/diagnóstico por imagen , Absceso Abdominal/cirugía , Colecistostomía/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/cirugía , Terapia Combinada , Quistes/diagnóstico por imagen , Quistes/cirugía , Gastrostomía/métodos , Alemania , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Hepatopatías/diagnóstico por imagen , Hepatopatías/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Nefrostomía Percutánea/métodos , Cuidados Paliativos/métodos , Paracentesis/métodos , Escleroterapia/métodos
9.
Ultraschall Med ; 37(1): 27-45, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26871408

RESUMEN

The third part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound assesses the evidence for ultrasound-guided and assisted interventions in abdominal treatment procedures. Recommendations for clinical practice are presented covering indications, contraindications, safety and efficacy of the broad variety of these techniques. In particular, drainage of abscesses and fluid collections, interventional tumor ablation techniques, interventional treatment of symptomatic cysts and echinococcosis, percutaneous transhepatic cholangiography and drainage, percutaneous gastrostomy, urinary bladder drainage, and nephrostomy are addressed (short version; a long version is published online).


Asunto(s)
Abdomen/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Absceso Abdominal/diagnóstico por imagen , Absceso Abdominal/cirugía , Neoplasias Abdominales/diagnóstico por imagen , Neoplasias Abdominales/cirugía , Colangiografía/métodos , Quistes/diagnóstico por imagen , Quistes/cirugía , Drenaje/métodos , Gastrostomía/métodos , Alemania , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Nefrostomía Percutánea/métodos , Seguridad del Paciente , Garantía de la Calidad de Atención de Salud , Resultado del Tratamiento , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/cirugía
10.
Ultraschall Med ; 36(6): 566-80, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26669869

RESUMEN

This is the second part of the series on interventional ultrasound guidelines of the Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB). It deals with the diagnostic interventional procedure. General points are discussed which are pertinent to all patients, followed by organ-specific imaging that will allow the correct pathway and planning for the interventional procedure. This will allow for the appropriate imaging workup for each individual interventional procedure (Long version/ short version; the long version is published online).


Asunto(s)
Abdomen/diagnóstico por imagen , Sociedades Médicas , Ultrasonografía Intervencional/métodos , Ultrasonografía/métodos , Europa (Continente) , Humanos , Imagen por Resonancia Magnética , Imagen Multimodal , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
11.
Ultraschall Med ; 36(6): E15-35, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26669871

RESUMEN

This is the second part of the series on interventional ultrasound guidelines of the Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB). It deals with the diagnostic interventional procedure. General points are discussed which are pertinent to all patients, followed by organ-specific imaging that will allow the correct pathway and planning for the interventional procedure. This will allow for the appropriate imaging workup for each individual interventional procedure (Long version).


Asunto(s)
Abdomen/diagnóstico por imagen , Sociedades Médicas , Ultrasonografía Intervencional , Ultrasonografía , Europa (Continente) , Medicina Basada en la Evidencia , Humanos
12.
Ultraschall Med ; 35(6): 515-21, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25226455

RESUMEN

PURPOSE: To evaluate CEUS for the diagnosis of pancreatic diseases and its application in the clinical routine with a focus on the value of CEUS in ductal pancreatic carcinoma and its use for the differentiation of neoplastic and non-neoplastic lesions. MATERIALS AND METHODS: All prospective and retrospective studies published in any language by March 6, 2014 were included based on the following criteria: use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced endoscopic ultrasound (ECEUS) as the imaging methods, use of histology as the reference method and availability of a complete translation. Two authors analyzed the titles and abstracts of the search results to identify all relevant publications. Two independent readers then analyzed the full articles to identify those meeting the inclusion criteria. Details regarding study design, patient characteristics, interventions, and results were then independently extracted by two radiologists and one reviewer with methodological expertise. Sensitivity, specificity and diagnostic odds ratio (DOR) were used to obtain overall estimates. RESULTS: 1293 articles were initially identified. 27 studies met the inclusion criteria. CEUS was the index test in 23 studies while ECEUS was the index test in 4 studies. The primary study objective was met by 20 studies with respect to ductal adenocarcinoma. CEUS sensitivity was evaluated in all studies. The pooled estimate of CEUS sensitivity for the diagnosis of ductal adenocarcinoma was 0.89 (95 % CI, 0.85 - 0.92). 15 out of 20 studies examined CEUS specificity. The average specificity was 0.84 (95 % CI, 0.77 - 0.89). The pooled estimate for DOR was 61.12 (95 % CI, 34.81 - 107.32). With regard to the secondary study objective, the pooled sensitivity and specificity were 0.95 (95 % CI, 0.93 - 0.96) from 14 studies and 0.72 (95 % CI, 0.58 - 0.83) from 13 studies, respectively. The pooled DOR was 57.63 (95 % CI, 33.62 - 98.78). CONCLUSION: The sensitivity, specificity, and DOR results show the high value of CEUS for the characterization and differentiation of ductal adenocarinomas from other pancreatic diseases and for cystic pancreatic lesions. For this reason and due to their noninvasive nature, CEUS and ECEUS should be used as the first methods for characterizing neoplastic pancreatic lesions, especially since these are often incidental findings. The methods improve the quality of ultrasound diagnostics and result in faster diagnosis and better disease management.


Asunto(s)
Endosonografía/métodos , Aumento de la Imagen/métodos , Enfermedades Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Diagnóstico Diferencial , Humanos , Páncreas/diagnóstico por imagen
13.
J Contemp Dent Pract ; 15(5): 626-35, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-25707838

RESUMEN

BACKGROUND: Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. AIM: The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. RESULTS: Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles in an autoclave. CONCLUSION: In this study, the final batch of the DS1922F prototype data logger was found to be robust in withstanding the challenge of 600 autoclave cycles, with a mean lifetime of more than 450 cycles, multiple times more than prescribed number of cycles. CLINICAL SIGNIFICANCE: Instrument reprocessing is among the important aspects of infection control. While stringent procedures are followed in instrument reprocessing within the clinic in assuring patient safety, regular use of sterilization process indicators and periodic biological validation of the sterilizer's performance is necessary. Chemical indicators for use in Autoclaves provide information on whether the particular cycle's parameters were achieved but do not provide at what specific point in time or temperature the failure occurred. Data loggers and associated reader software as the tested prototype in this evaluation (DS1922F), are designed to provide continuous information on time and temperature of the prescribed cycle. Data loggers provide immediate information on the process as opposed to Biological Indicators that take from days to a week in obtaining a confirmatory result. Further, many countries do not have the sterilization monitoring service infrastructure to meet the demands of the end users. In the absence of sterilization monitoring services, use of digital data loggers for each sterilization cycle is more pragmatic.


Asunto(s)
Esterilización/normas , Exactitud de los Datos , Equipos y Suministros Eléctricos , Contaminación de Equipos/prevención & control , Diseño de Equipo , Falla de Equipo , Calor , Humanos , Indicadores y Reactivos , Ensayo de Materiales , Control de Calidad , Programas Informáticos , Esterilización/instrumentación , Factores de Tiempo
14.
Ultraschall Med ; 34(5): 454-62, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23238800

RESUMEN

PURPOSE: The recent guidelines published in 2011 suggest the use of only one imaging method for the final imaging diagnosis of hepatocellular carcinoma. To evaluate the methods in the context of the available literature evidence, this systematic review aimed at assessing the relative performance of different imaging techniques currently used in clinical practice. MATERIALS AND METHODS: MEDLINE and EMBASE were searched from January 1996 to June 2011, with no language limitation. Eligible trials had to be conducted in patients with suspicion or diagnosis of hepatocellular carcinoma; compare at least two of the following imaging modalities: magnetic resonance imaging, computed tomography, ultrasound; have pathological findings as a reference standard. An analysis also including non-comparative studies was performed as a validation of the main comparison results. RESULTS: Of 5,144 screened papers, 16 studies fulfilled the eligibility criteria for the comparative analysis and 65 were eligible for the non-comparative analysis. The overall sensitivity and specificity derived by the pooled analysis were 0.78 and 0.77 for computed tomography, 0.84 and 0.84 for magnetic resonance imaging and 0.86 and 0.77 for ultrasound, respectively. In the pair-wise comparisons, ultrasound showed a statistically better specificity than magnetic resonance imaging (0.86 vs. 0.78; p = 0.014) and a statistically better sensitivity than computed tomography (0.88 vs. 0.78; p = 0.030). CONCLUSION: The present systematic review did not show an obvious superiority of one imaging method. Since their accuracy is not completely overlapping, the possibility of reaching better performance by combining methods should be considered in future prospective trials.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Tomografía Computarizada por Rayos X , Ultrasonografía , Carcinoma Hepatocelular/patología , Humanos , Hígado/patología , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética , Sensibilidad y Especificidad
15.
Ultraschall Med ; 34(4): 377-81, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23023447

RESUMEN

PURPOSE: The aim of this study is to compare CEUS and MDCT features of pancreatic ductal adenocarcinoma in relation to tumor size. MATERIALS AND METHODS: All patients with pathological diagnosis of pancreatic adenocarcinoma and studied by means of CEUS and MDCT were enrolled in this study. Two radiologists evaluated tumor size, site and imaging appearance. Patients in which at least one method yielded a positive result were divided into 4 groups on the basis of lesion size. For each dimensional category, sensitivity of the two imaging methods was calculated and compared using McNemar test. RESULTS: One hundred thirty-three patients were included in this study. In 9 of 133 patients neither MDCT nor US/CEUS could identify the lesion, while in 9 of 133 patients only MDCT and in 13 of 133 only US/CEUS could identify the lesion. In the remaining 102 patients, both MDCT and US/CEUS yielded a positive result. US/CEUS sensitivity was 86.47% while MDCT sensitivity was 83.58%, with no statistically significant difference (p = 0.523). For lesions smaller than 2 cm US/CEUS had a 100% sensitivity, while MDCT had a 73.33% sensitivity with no statistically significant difference (p = 0.125). For lesions between 2.1 and 3 cm US/CEUS had a sensitivity of 95.35%, while MDCT had a sensitivity of 83.72% with no statistically significant difference (p = 0.180). For lesions between 3.1 and 4 cm, US/CEUS had a sensitivity of 87.88%, while MDCT had a sensitivity of 93.94% with no statistically significant difference (p = 0.688). For lesions larger than 4 cm US/CEUS, had a sensitivity of 90.91%, while MDCT had a sensitivity of 100% with no statistically significant difference (p = 0.250). CONCLUSION: US/CEUS sensitivity in diagnosing pancreatic ductal adenocarcinoma is adequate and does not statistically differ from that of MDCT. US/CEUS sensitivity seems to be higher for small and medium lesions, while MDCT sensitivity is higher for large lesions. By combining both the imaging methods a higher accuracy in diagnosing pancreatic ductal adenocarcinoma can be expected.


Asunto(s)
Adenocarcinoma/diagnóstico , Medios de Contraste , Aumento de la Imagen , Tomografía Computarizada Multidetector , Neoplasias Pancreáticas/diagnóstico , Ultrasonografía , Adenocarcinoma/irrigación sanguínea , Adenocarcinoma/metabolismo , Humanos , Páncreas/irrigación sanguínea , Páncreas/patología , Neoplasias Pancreáticas/irrigación sanguínea , Neoplasias Pancreáticas/patología , Estudios Retrospectivos , Sensibilidad y Especificidad
16.
Ultraschall Med ; 34(2): 169-84, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23558397

RESUMEN

The technical part of these Guidelines and Recommendations, produced under the auspices of EFSUMB, provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based. A difference in shear modulus is the common underlying physical mechanism that provides tissue contrast in all elastograms. The relationship between the alternative technologies is considered in terms of the method used to take advantage of this. The practical advantages and disadvantages associated with each of the techniques are described, and guidance is provided on optimisation of scanning technique, image display, image interpretation and some of the known image artefacts.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Animales , Artefactos , Neoplasias de la Mama/diagnóstico por imagen , Quistes/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/instrumentación , Diseño de Equipo , Europa (Continente) , Femenino , Humanos , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Palpación , Fantasmas de Imagen , Sensibilidad y Especificidad , Resistencia al Corte , Transductores , Pavos , Ultrasonografía Mamaria/instrumentación , Ultrasonografía Mamaria/métodos
17.
Ultraschall Med ; 34(3): 238-53, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23605169

RESUMEN

The clinical part of these Guidelines and Recommendations produced under the auspices of the European Federation of Societies for Ultrasound in Medicine and Biology EFSUMB assesses the clinically used applications of all forms of elastography, stressing the evidence from meta-analyses and giving practical advice for their uses and interpretation. Diffuse liver disease forms the largest section, reflecting the wide experience with transient and shear wave elastography . Then follow the breast, thyroid, gastro-intestinal tract, endoscopic elastography, the prostate and the musculo-skeletal system using strain and shear wave elastography as appropriate. The document is intended to form a reference and to guide clinical users in a practical way.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Diagnóstico por Imagen de Elasticidad/instrumentación , Endosonografía/métodos , Diseño de Equipo , Medicina Basada en la Evidencia , Enfermedades Gastrointestinales/diagnóstico por imagen , Humanos , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Hepatopatías/diagnóstico por imagen , Masculino , Metaanálisis como Asunto , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Sensibilidad y Especificidad , Enfermedades de la Tiroides/diagnóstico por imagen , Ultrasonografía Mamaria/métodos
18.
Radiol Med ; 118(2): 163-80, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22744342

RESUMEN

PURPOSE: The authors sought to determine magnetic resonance/magnetic resonance cholangiopancreatography (MR/MRCP) imaging features of incidentally discovered benign, noncommunicating cystic neoplasms (BNCNs) of the pancreas to assess their evolution over time and identify MR/MRCP imaging features predictive of tumour growth. MATERIAL AND METHODS: This was a retrospective study, so informed consent was waived. Sixty-two patients with a diagnosis of BNCN were assessed. Inclusion criteria were incidentally discovered cystic neoplasm of the pancreas with nonmeasurable walls, no mural nodules and no communication with the pancreatic ductal system and who underwent ≥ 1 MR/MRCP examination. Image analysis, performed at diagnosis and during follow-up, included macroscopic pattern (microcystic/macrocystic/mixed), number of cysts (unicystic/oligocystic/multicystic), BNCN maximum diameter and tumour growth rates. RESULTS: A total of 64 BNCNs was detected. Macroscopic pattern was mixed in 31/64 (48%), microcystic in 28/64 (44%) and macrocystic in 5/64 (8%). BNCNs appeared multicystic in 38/64 (59%) cases, oligocystic in 22/64 (35%) and unicystic in 4/64(6%). All qualitative parameters remained unchanged during follow-up. At diagnosis, the median maximum BNCN diameter was 35.0 mm and 38.0 mm at the final examination (p<0.001). BNCNs showed a tumour growth rate of 2 mm/year. CONCLUSIONS: Mixed and microcystic patterns were the most common, accounting for 48% and 44% of cases, respectively, and showed no change over time. MR/MRCP features predictive of lesion enlargement were a mixed/ macrocystic pattern, and lesion size was >3 cm (both p<0.001).


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias Pancreáticas/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Pancreatocolangiografía por Resonancia Magnética/métodos , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador , Hallazgos Incidentales , Modelos Logísticos , Nanopartículas de Magnetita , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/patología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Siloxanos , Estadísticas no Paramétricas
19.
Radiol Med ; 117(2): 268-81, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22271005

RESUMEN

PURPOSE: The presence of disease activity in Crohn's disease (CD) is one of the main parameters used to establish whether optimal therapy should be drug therapy or surgery. However, a major problem in monitoring CD is the common mismatch between the patient's symptoms and imaging objective signs of disease activity. Bowel ultrasonography (US) has emerged as a low-cost, noninvasive technique in the diagnosis and follow-up of patients with CD. Accordingly, the use of contrast-enhanced US (CEUS) has made possible an evaluation of the vascular enhancement pattern, similar to the use of magnetic resonance imaging (MRI). The aim of our study was to evaluate the role of CEUS in comparison with small-bowel MRI for assessing Crohn's disease activity. MATERIALS AND METHODS: We prospectively enrolled 30 consecutive patients with known CD. Clinical and laboratory data were compared with imaging findings obtained from MRI and CEUS of the small bowel. MRI was performed with a 1.5-T system using phased-array coils and biphasic orally administered contrast agent prior to and after gadolinium chelate administration. We performed US with a 7.5-MHz linear-array probe and a second-generation contrast agent. The parameters analysed in both techniques were the following: lesion length, wall thickness, layered wall appearance, comb sign, fibroadipose proliferation, presence of enlarged lymph nodes and stenosis. We classified parietal enhancement curves into two types in relation to the contrast pattern obtained with the time-intensity curves at MRI and CEUS: (1) quick washin, quick washout, (2) slow washin, plateau with a slow washout. RESULTS: Comparison between Crohn's disease activity index (CDAI) and MRI showed a low correlation, with an rho=0.398; correlation between CDAI-laboratory data and CEUS activity was low, with rho=0.354; correlation between MRI activity and CEUS activity was good, with rho = 0.791; high correlation was found between CEUS and MRI of the small bowel when assessing wall-thickness, lymph nodes and comb sign; good correlation was fund when assessing layered wall appearance, disease extension and fibroadipose proliferation. At MRI, time-intensity curves for 12/30 patients were active, compared with for 14/30 patients at CEUS; therefore there was a poor correlation between curve on CEUS and curve on MRI (r=0.167; p=0.36). CONCLUSIONS: The use of CEUS can be recommended if there is a discrepancy between MRI and clinical/laboratory parameters. MRI of the small bowel remains the most accurate method for evaluating disease activity.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/diagnóstico , Intestino Delgado , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía
20.
Radiol Med ; 117(6): 939-52, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22744347

RESUMEN

PURPOSE: The authors sought to evaluate the incremental value of introducing coronary angiography with multidetector computed tomography (MDCT-CA) compared with the conventional diagnostic workup in managing patients with suspected coronary artery disease (CAD) workup. MATERIALS AND METHODS: A total of 531 consecutive patients underwent MDCT-CA between April 2008 and August 2010. For each patient the pretest probability of CAD was obtained by using the Morise score as well as the diagnostic performance of the exercise test and of MDCT-CA, considering conventional coronary angiography (CCA) as the gold standard. Based on these results, we calculated the posttest likelihood of CAD after stress testing, comparing the incremental diagnostic value for each category of cardiovascular risk with data obtained with MDCT-CA. The conventional diagnostic workup (without MDCT-CA) was then compared with the modified workup (including MDCT-CA). RESULTS: The diagnostic performance of the exercise test for identifying patients with significant lesions had a sensitivity and specificity of 20% and 88%, respectively, with positive (PPV) and negative (NPV) predictive value of 41% and 72%, respectively. Taking CA as the gold standard, MDCT-CA had 93% sensitivity, 89% specificity, 88% PPV and 93% NPV compared with CCA in evaluating significant stenoses in the per-patient analysis. The overall diagnostic accuracy of MDCT-CA was 91%. The exercise tests provided no significant incremental diagnostic value compared with cardiovascular history in patients with a low to intermediate risk. Comparison of the diagnostic accuracy of these protocols showed improved performance results for the modified protocol. CONCLUSIONS: MDCT-CA is the reference modality for the noninvasive exclusion of critical CAD. It provides a very high incremental diagnostic value compared with exercise testing in patients with a low to intermediate risk of CAD. The use of diagnostic protocols based on MDCT-CA ensures improved diagnostic performance compared with those involving conventional exercise electrocardiograms.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda