Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Circulation ; 148(10): 808-818, 2023 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-37463608

RESUMEN

BACKGROUND: In hypertrophic cardiomyopathy (HCM), myocyte disarray and microvascular disease (MVD) have been implicated in adverse events, and recent evidence suggests that these may occur early. As novel therapy provides promise for disease modification, detection of phenotype development is an emerging priority. To evaluate their utility as early and disease-specific biomarkers, we measured myocardial microstructure and MVD in 3 HCM groups-overt, either genotype-positive (G+LVH+) or genotype-negative (G-LVH+), and subclinical (G+LVH-) HCM-exploring relationships with electrical changes and genetic substrate. METHODS: This was a multicenter collaboration to study 206 subjects: 101 patients with overt HCM (51 G+LVH+ and 50 G-LVH+), 77 patients with G+LVH-, and 28 matched healthy volunteers. All underwent 12-lead ECG, quantitative perfusion cardiac magnetic resonance imaging (measuring myocardial blood flow, myocardial perfusion reserve, and perfusion defects), and cardiac diffusion tensor imaging measuring fractional anisotropy (lower values expected with more disarray), mean diffusivity (reflecting myocyte packing/interstitial expansion), and second eigenvector angle (measuring sheetlet orientation). RESULTS: Compared with healthy volunteers, patients with overt HCM had evidence of altered microstructure (lower fractional anisotropy, higher mean diffusivity, and higher second eigenvector angle; all P<0.001) and MVD (lower stress myocardial blood flow and myocardial perfusion reserve; both P<0.001). Patients with G-LVH+ were similar to those with G+LVH+ but had elevated second eigenvector angle (P<0.001 after adjustment for left ventricular hypertrophy and fibrosis). In overt disease, perfusion defects were found in all G+ but not all G- patients (100% [51/51] versus 82% [41/50]; P=0.001). Patients with G+LVH- compared with healthy volunteers similarly had altered microstructure, although to a lesser extent (all diffusion tensor imaging parameters; P<0.001), and MVD (reduced stress myocardial blood flow [P=0.015] with perfusion defects in 28% versus 0 healthy volunteers [P=0.002]). Disarray and MVD were independently associated with pathological electrocardiographic abnormalities in both overt and subclinical disease after adjustment for fibrosis and left ventricular hypertrophy (overt: fractional anisotropy: odds ratio for an abnormal ECG, 3.3, P=0.01; stress myocardial blood flow: odds ratio, 2.8, P=0.015; subclinical: fractional anisotropy odds ratio, 4.0, P=0.001; myocardial perfusion reserve odds ratio, 2.2, P=0.049). CONCLUSIONS: Microstructural alteration and MVD occur in overt HCM and are different in G+ and G- patients. Both also occur in the absence of hypertrophy in sarcomeric mutation carriers, in whom changes are associated with electrocardiographic abnormalities. Measurable changes in myocardial microstructure and microvascular function are early-phenotype biomarkers in the emerging era of disease-modifying therapy.


Asunto(s)
Cardiomiopatía Hipertrófica , Hipertrofia Ventricular Izquierda , Humanos , Sarcómeros/genética , Imagen de Difusión Tensora , Predisposición Genética a la Enfermedad , Mutación , Cardiomiopatía Hipertrófica/diagnóstico , Fenotipo , Biomarcadores , Fibrosis
2.
Magn Reson Med ; 92(3): 1022-1034, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38650395

RESUMEN

PURPOSE: This work reports for the first time on the implementation and application of cardiac diffusion-weighted MRI on a Connectom MR scanner with a maximum gradient strength of 300 mT/m. It evaluates the benefits of the increased gradient performance for the investigation of the myocardial microstructure. METHODS: Cardiac diffusion-weighted imaging (DWI) experiments were performed on 10 healthy volunteers using a spin-echo sequence with up to second- and third-order motion compensation ( M 2 $$ {M}_2 $$ and M 3 $$ {M}_3 $$ ) and b = 100 , 450 $$ b=100,450 $$ , and 1000 s / m m 2 $$ \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ (twice the b max $$ {b}_{\mathrm{max}} $$ commonly used on clinical scanners). Mean diffusivity (MD), fractional anisotropy (FA), helix angle (HA), and secondary eigenvector angle (E2A) were calculated for b = [100, 450] s / m m 2 $$ \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ and b = [100, 1000] s / m m 2 $$ \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ for both M 2 $$ {M}_2 $$ and M 3 $$ {M}_3 $$ . RESULTS: The MD values with M 3 $$ {M}_3 $$ are slightly higher than with M 2 $$ {M}_2 $$ with Δ MD = 0 . 05 ± 0 . 05 [ × 1 0 - 3 mm 2 / s ] ( p = 4 e - 5 ) $$ \Delta \mathrm{MD}=0.05\pm 0.05\kern0.3em \left[\times 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=4e-5\right) $$ for b max = 450 s / mm 2 $$ {b}_{\mathrm{max}}=450\kern0.3em \mathrm{s}/{\mathrm{mm}}^2 $$ and Δ MD = 0 . 03 ± 0 . 03 [ × 1 0 - 3 mm 2 / s ] ( p = 4 e - 4 ) $$ \Delta \mathrm{MD}=0.03\pm 0.03\kern0.3em \left[\times \kern0.3em 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=4e-4\right) $$ for b max = 1000 s / mm 2 $$ {b}_{\mathrm{max}}=1000\kern0.3em \mathrm{s}/{\mathrm{mm}}^2 $$ . A reduction in MD is observed by increasing the b max $$ {b}_{\mathrm{max}} $$ from 450 to 1000 s / mm 2 $$ \mathrm{s}/{\mathrm{mm}}^2 $$ ( Δ MD = 0 . 06 ± 0 . 04 [ × 1 0 - 3 mm 2 / s ] ( p = 1 . 6 e - 9 ) $$ \Delta \mathrm{MD}=0.06\pm 0.04\kern0.3em \left[\times \kern0.3em 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=1.6e-9\right) $$ for M 2 $$ {M}_2 $$ and Δ MD = 0 . 08 ± 0 . 05 [ × 1 0 - 3 mm 2 / s ] ( p = 1 e - 9 ) $$ \Delta \mathrm{MD}=0.08\pm 0.05\kern0.3em \left[\times \kern0.3em 1{0}^{-3}\kern0.3em {\mathrm{mm}}^2/\mathrm{s}\right]\kern0.3em \left(p=1e-9\right) $$ for M 3 $$ {M}_3 $$ ). The difference between FA, E2A, and HA was not significant in different schemes ( p > 0 . 05 $$ p>0.05 $$ ). CONCLUSION: This work demonstrates cardiac DWI in vivo with higher b-value and higher order of motion compensated diffusion gradient waveforms than is commonly used. Increasing the motion compensation order from M 2 $$ {M}_2 $$ to M 3 $$ {M}_3 $$ and the maximum b-value from 450 to 1000 s / mm 2 $$ \mathrm{s}/{\mathrm{mm}}^2 $$ affected the MD values but FA and the angular metrics (HA and E2A) remained unchanged. Our work paves the way for cardiac DWI on the next-generation MR scanners with high-performance gradient systems.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Corazón , Humanos , Masculino , Adulto , Corazón/diagnóstico por imagen , Femenino , Voluntarios Sanos , Procesamiento de Imagen Asistido por Computador/métodos , Reproducibilidad de los Resultados , Anisotropía , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos
3.
BMC Cardiovasc Disord ; 24(1): 329, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943084

RESUMEN

BACKGROUND: Pulmonary transit time (PTT) can be measured automatically from arterial input function (AIF) images of dual sequence first-pass perfusion imaging. PTT has been validated against invasive cardiac catheterisation correlating with both cardiac output and left ventricular filling pressure (both important prognostic markers in heart failure). We hypothesized that prolonged PTT is associated with clinical outcomes in patients with heart failure. METHODS: We recruited outpatients with a recent diagnosis of non-ischaemic heart failure with left ventricular ejection fraction (LVEF) < 50% on referral echocardiogram. Patients were followed up by a review of medical records for major adverse cardiovascular events (MACE) defined as all-cause mortality, heart failure hospitalization, ventricular arrhythmia, stroke or myocardial infarction. PTT was measured automatically from low-resolution AIF dynamic series of both the LV and RV during rest perfusion imaging, and the PTT was measured as the time (in seconds) between the centroid of the left (LV) and right ventricle (RV) indicator dilution curves. RESULTS: Patients (N = 294) were followed-up for median 2.0 years during which 37 patients (12.6%) had at least one MACE event. On univariate Cox regression analysis there was a significant association between PTT and MACE (Hazard ratio (HR) 1.16, 95% confidence interval (CI) 1.08-1.25, P = 0.0001). There was also significant association between PTT and heart failure hospitalisation (HR 1.15, 95% CI 1.02-1.29, P = 0.02) and moderate correlation between PTT and N-terminal pro B-type natriuretic peptide (NT-proBNP, r = 0.51, P < 0.001). PTT remained predictive of MACE after adjustment for clinical and imaging factors but was no longer significant once adjusted for NT-proBNP. CONCLUSIONS: PTT measured automatically during CMR perfusion imaging in patients with recent onset non-ischaemic heart failure is predictive of MACE and in particular heart failure hospitalisation. PTT derived in this way may be a non-invasive marker of haemodynamic congestion in heart failure and future studies are required to establish if prolonged PTT identifies those who may warrant closer follow-up or medicine optimisation to reduce the risk of future adverse events.


Asunto(s)
Insuficiencia Cardíaca , Imagen de Perfusión Miocárdica , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Masculino , Femenino , Persona de Mediana Edad , Anciano , Factores de Tiempo , Pronóstico , Imagen de Perfusión Miocárdica/métodos , Factores de Riesgo , Circulación Pulmonar , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/diagnóstico por imagen , Medición de Riesgo , Función Ventricular Derecha , Imagen por Resonancia Magnética
4.
Magn Reson Med ; 90(5): 2144-2157, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37345727

RESUMEN

PURPOSE: This paper presents a hierarchical modeling approach for estimating cardiomyocyte major and minor diameters and intracellular volume fraction (ICV) using diffusion-weighted MRI (DWI) data in ex vivo mouse hearts. METHODS: DWI data were acquired on two healthy controls and two hearts 3 weeks post transverse aortic constriction (TAC) using a bespoke diffusion scheme with multiple diffusion times ( Δ $$ \Delta $$ ), q-shells and diffusion encoding directions. Firstly, a bi-exponential tensor model was fitted separately at each diffusion time to disentangle the dependence on diffusion times from diffusion weightings, that is, b-values. The slow-diffusing component was attributed to the restricted diffusion inside cardiomyocytes. ICV was then extrapolated at Δ = 0 $$ \Delta =0 $$ using linear regression. Secondly, given the secondary and the tertiary diffusion eigenvalue measurements for the slow-diffusing component obtained at different diffusion times, major and minor diameters were estimated assuming a cylinder model with an elliptical cross-section (ECS). High-resolution three-dimensional synchrotron X-ray imaging (SRI) data from the same specimen was utilized to evaluate the biophysical parameters. RESULTS: Estimated parameters using DWI data were (control 1/control 2 vs. TAC 1/TAC 2): major diameter-17.4 µ $$ \mu $$ m/18.0 µ $$ \mu $$ m versus 19.2 µ $$ \mu $$ m/19.0 µ $$ \mu $$ m; minor diameter-10.2 µ $$ \mu $$ m/9.4 µ $$ \mu $$ m versus 12.8 µ $$ \mu $$ m/13.4 µ $$ \mu $$ m; and ICV-62%/62% versus 68%/47%. These findings were consistent with SRI measurements. CONCLUSION: The proposed method allowed for accurate estimation of biophysical parameters suggesting cardiomyocyte diameters as sensitive biomarkers of hypertrophy in the heart.


Asunto(s)
Estenosis de la Válvula Aórtica , Miocitos Cardíacos , Ratones , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Cardiomegalia/diagnóstico por imagen , Imagenología Tridimensional
5.
Magn Reson Med ; 90(1): 150-165, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36941736

RESUMEN

PURPOSE: Tensor-valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor-valued diffusion encoding at high b-values with q-space trajectory imaging (QTI) analysis, in the human heart in vivo. METHODS: Ten healthy volunteers were scanned on a 3T scanner. We designed time-optimal gradient waveforms for tensor-valued diffusion encoding (linear and planar) with second-order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (µFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence (Cc ). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time. RESULTS: QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 µm2 /ms, FA = 0.31 ± 0.03, µFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and Cc  = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas µFA was insensitive to this effect. CONCLUSION: We demonstrated the first tensor-valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial µFA, MKi, MKa, and Cc . The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.


Asunto(s)
Imagen de Difusión Tensora , Corazón , Humanos , Imagen de Difusión Tensora/métodos , Corazón/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Miocardio , Ventrículos Cardíacos , Anisotropía
6.
J Cardiovasc Magn Reson ; 25(1): 43, 2023 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-37496072

RESUMEN

BACKGROUND: When feasible, guidelines recommend mitral valve repair (MVr) over mitral valve replacement (MVR) to treat primary mitral regurgitation (MR), based upon historic outcome studies and transthoracic echocardiography (TTE) reverse remodeling studies. Cardiovascular magnetic resonance (CMR) offers reference standard biventricular assessment with superior MR quantification compared to TTE. Using serial CMR in primary MR patients, we aimed to investigate cardiac reverse remodeling and residual MR post-MVr vs MVR with chordal preservation. METHODS: 83 patients with ≥ moderate-severe MR on TTE were prospectively recruited. 6-min walk tests (6MWT) and CMR imaging including cine imaging, aortic/pulmonary through-plane phase contrast imaging, T1 maps and late-gadolinium-enhanced (LGE) imaging were performed at baseline and 6 months after mitral surgery or watchful waiting (control group). RESULTS: 72 patients completed follow-up (Controls = 20, MVr = 30 and MVR = 22). Surgical groups demonstrated comparable baseline cardiac indices and co-morbidities. At 6-months, MVr and MVR groups demonstrated comparable improvements in 6MWT distances (+ 57 ± 54 m vs + 64 ± 76 m respectively, p = 1), reduced indexed left ventricular end-diastolic volumes (LVEDVi; - 29 ± 21 ml/m2 vs - 37 ± 22 ml/m2 respectively, p = 0.584) and left atrial volumes (- 23 ± 30 ml/m2 and - 39 ± 26 ml/m2 respectively, p = 0.545). At 6-months, compared with controls, right ventricular ejection fraction was poorer post-MVr (47 ± 6.1% vs 53 ± 8.0% respectively, p = 0.01) compared to post-MVR (50 ± 5.7% vs 53 ± 8.0% respectively, p = 0.698). MVR resulted in lower residual MR-regurgitant fraction (RF) than MVr (12 ± 8.0% vs 21 ± 11% respectively, p = 0.022). Baseline and follow-up indices of diffuse and focal myocardial fibrosis (Native T1 relaxation times, extra-cellular volume and quantified LGE respectively) were comparable between groups. Stepwise multiple linear regression of indexed variables in the surgical groups demonstrated baseline indexed mitral regurgitant volume as the sole multivariate predictor of left ventricular (LV) end-diastolic reverse remodelling, baseline LVEDVi as the most significant independent multivariate predictor of follow-up LVEDVi, baseline indexed LV end-systolic volume as the sole multivariate predictor of follow-up LV ejection fraction and undergoing MVR (vs MVr) as the most significant (p < 0.001) baseline multivariate predictor of lower residual MR. CONCLUSION: In primary MR, MVR with chordal preservation may offer comparable cardiac reverse remodeling and functional benefits at 6-months when compared to MVr. Larger, multicenter CMR studies are required, which if the findings are confirmed could impact future surgical practice.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/patología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Volumen Sistólico , Valor Predictivo de las Pruebas , Función Ventricular Derecha , Fibrosis
7.
NMR Biomed ; 35(6): e4685, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34967060

RESUMEN

Cardiac diffusion tensor imaging (DTI) is an emerging technique for the in vivo characterisation of myocardial microstructure, and there is a growing need for its validation and standardisation. We sought to establish the accuracy, precision, repeatability and reproducibility of state-of-the-art pulse sequences for cardiac DTI among 10 centres internationally. Phantoms comprising 0%-20% polyvinylpyrrolidone (PVP) were scanned with DTI using a product pulsed gradient spin echo (PGSE; N = 10 sites) sequence, and a custom motion-compensated spin echo (SE; N = 5) or stimulated echo acquisition mode (STEAM; N = 5) sequence suitable for cardiac DTI in vivo. A second identical scan was performed 1-9 days later, and the data were analysed centrally. The average mean diffusivities (MDs) in 0% PVP were (1.124, 1.130, 1.113) x 10-3  mm2 /s for PGSE, SE and STEAM, respectively, and accurate to within 1.5% of reference data from the literature. The coefficients of variation in MDs across sites were 2.6%, 3.1% and 2.1% for PGSE, SE and STEAM, respectively, and were similar to previous studies using only PGSE. Reproducibility in MD was excellent, with mean differences in PGSE, SE and STEAM of (0.3 ± 2.3, 0.24 ± 0.95, 0.52 ± 0.58) x 10-5  mm2 /s (mean ± 1.96 SD). We show that custom sequences for cardiac DTI provide accurate, precise, repeatable and reproducible measurements. Further work in anisotropic and/or deforming phantoms is warranted.


Asunto(s)
Imagen de Difusión Tensora , Corazón , Anisotropía , Imagen de Difusión Tensora/métodos , Corazón/diagnóstico por imagen , Fantasmas de Imagen , Reproducibilidad de los Resultados
8.
J Magn Reson Imaging ; 56(3): 768-778, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-34854151

RESUMEN

BACKGROUND: Four-dimensional (4D) flow cardiac magnetic resonance (cardiac MR) imaging provides quantification of intracavity left ventricular (LV) flow kinetic energy (KE) parameters in three dimensions. ST-elevation myocardial infarction (STEMI) patients have been shown to have altered intracardiac blood flow compared to controls; however, how 4D flow parameters change over time has not been explored previously. PURPOSE: Measure longitudinal changes in intraventricular flow post-STEMI and ascertain its predictive relevance of long-term cardiac remodeling. STUDY TYPE: Prospective. POPULATION: Thirty-five STEMI patients (M:F = 26:9, aged 56 ± 9 years). FIELD STRENGTH/SEQUENCE: A 3 T/3D EPI-based, fast field echo (FFE) free-breathing 4D-flow sequence with retrospective cardiac gating. ASSESSMENT: Serial imaging at 3-7 days (V1), 3-months (V2), and 12-months (V3) post-STEMI, including the following protocol: functional imaging for measuring volumes and 4D-flow for calculating parameters including systolic and peakE-wave LVKE, normalized to end-diastolic volume (iEDV) and stroke volume (iSV). Data were analyzed by H.B. (3 years experience). Patients were categorized into two groups: preserved ejection fraction (pEF, if EF > 50%) and reduced EF (rEF, if EF < 50%). STATISTICAL TESTS: Independent sample t-tests were used to detect the statistical significance between any two cohorts. P < 0.05 was considered statistically significant. RESULTS: Across the cohort, systolic KEisv was highest at V1 (28.0 ± 4.4 µJ/mL). Patients with rEF retained significantly higher systolic KEisv than patients with pEF at V2 (18.2 ± 3.4 µJ/mL vs. 6.9 ± 0.6 µJ/mL, P < 0.001) and V3 (21.6 ± 5.1 µJ/mL vs. 7.4 ± 0.9 µJ/mL, P < 0.001). Patients with pEF had significantly higher peakE-wave KEiEDV than rEF patients throughout the study (V1: 25.4 ± 11.6 µJ/mL vs. 18.1 ± 9.9 µJ/mL, P < 0.03, V2: 24.0 ± 10.2 µJ/mL vs. 17.2 ± 12.2 µJ/mL, P < 0.05, V3: 27.7 ± 14.8 µJ/mL vs. 15.8 ± 7.6 µJ/mL, P < 0.04). DATA CONCLUSION: Systolic KE increased acutely following MI; in patients with pEF, this decreased over 12 months, while patients with rEF, this remained raised. Compared to patients with pEF, persistently lower peakE-wave KE in rEF patients is suggestive of early and fixed impairment in diastolic function. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio/diagnóstico por imagen , Estudios Prospectivos , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda , Remodelación Ventricular
9.
J Magn Reson Imaging ; 56(4): 1171-1181, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35019174

RESUMEN

BACKGROUND: Intramyocardial hemorrhage (IMH) following ST-elevation myocardial infarction (STEMI) is associated with poor prognosis. In cardiac magnetic resonance (MR), T2* mapping is the reference standard for detecting IMH while cardiac diffusion tensor imaging (cDTI) can characterize myocardial architecture via fractional anisotropy (FA) and mean diffusivity (MD) of water molecules. The value of cDTI in the detection of IMH is not currently known. HYPOTHESIS: cDTI can detect IMH post-STEMI. STUDY TYPE: Prospective. SUBJECTS: A total of 50 patients (20% female) scanned at 1-week (V1) and 3-month (V2) post-STEMI. FIELD STRENGTH/SEQUENCE: A 3.0 T; inversion-recovery T1-weighted-imaging, multigradient-echo T2* mapping, spin-echo cDTI. ASSESSMENT: T2* maps were analyzed to detect IMH (defined as areas with T2* < 20 msec within areas of infarction). cDTI images were co-registered to produce averaged diffusion-weighted-images (DWIs), MD, and FA maps; hypointense areas were manually planimetered for IMH quantification. STATISTICS: On averaged DWI, the presence of hypointense signal in areas matching IMH on T2* maps constituted to true-positive detection of iron. Independent samples t-tests were used to compare regional cDTI values. Results were considered statistically significant at P ≤ 0.05. RESULTS: At V1, 24 patients had IMH on T2*. On averaged DWI, all 24 patients had hypointense signal in matching areas. IMH size derived using averaged-DWI was nonsignificantly greater than from T2* (2.0 ± 1.0 cm2 vs 1.89 ± 0.96 cm2 , P = 0.69). Compared to surrounding infarcted myocardium, MD was significantly reduced (1.29 ± 0.20 × 10-3  mm2 /sec vs 1.75 ± 0.16 × 10-3  mm2 /sec) and FA was significantly increased (0.40 ± 0.07 vs 0.23 ± 0.03) within areas of IMH. By V2, all 24 patients with acute IMH continued to have hypointense signals on averaged-DWI in the affected area. T2* detected IMH in 96% of these patients. Overall, averaged-DWI had 100% sensitivity and 96% specificity for the detection of IMH. DATA CONCLUSION: This study demonstrates that the parameters MD and FA are susceptible to the paramagnetic properties of iron, enabling cDTI to detect IMH. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Infarto del Miocardio con Elevación del ST , Imagen de Difusión Tensora , Femenino , Hemorragia/patología , Humanos , Hierro , Imagen por Resonancia Cinemagnética/métodos , Masculino , Miocardio/patología , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/patología
10.
J Cardiovasc Magn Reson ; 24(1): 64, 2022 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-36404326

RESUMEN

BACKGROUND: Despite advancements in percutaneous coronary intervention, a significant proportion of ST-elevation myocardial infarction (STEMI) survivors develop long-term adverse left ventricular (LV) remodelling, which is associated with poor prognosis. Adverse remodelling is difficult to predict, however four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) can measure various aspects of LV intra-cavity flow beyond LV ejection fraction and is well equipped for exploring the underlying mechanical processes driving remodelling. The aim for this study was to compare acute 4D flow CMR parameters between patients who develop adverse remodelling with patients who do not. METHODS: Fifty prospective 'first-event' STEMI patients underwent CMR 5 days post-reperfusion, which included cine-imaging, and 4D flow for assessing in-plane kinetic energy (KE), residual volume, peak-E and peak-A wave KE (indexed for LV end-diastolic volume [LVEDV]). All subjects underwent follow-up cine CMR imaging at 12 months to identify adverse remodelling (defined as 20% increase in LVEDV from baseline). Quantitative variables were compared using unpaired student's t-test. Tests were deemed statistically significant when p < 0.05. RESULTS: Patients who developed adverse LV remodelling by 12 months had significantly higher in-plane KE (54 ± 12 vs 42 ± 10%, p = 0.02), decreased proportion of direct flow (27 ± 9% vs 11 ± 4%, p < 0.01), increased proportion of delayed ejection flow (22 ± 9% vs 12 ± 2, p < 0.01) and increased proportion of residual volume after 2 consecutive cardiac cycles (64 ± 14 vs 34 ± 14%, p < 0.01), in their acute scan. CONCLUSION: Following STEMI, increased in-plane KE, reduced direct flow and increased residual volume in the acute scan were all associated with adverse LV remodelling at 12 months. Our results highlight the clinical utility of acute 4D flow in prognostic stratification in patients following myocardial infarction.


Asunto(s)
Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Estudios Prospectivos , Valor Predictivo de las Pruebas , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Remodelación Ventricular
11.
J Cardiovasc Magn Reson ; 24(1): 65, 2022 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-36404335

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is an important diagnostic test used in the evaluation of patients with heart failure (HF). However, the demographics and clinical characteristics of those undergoing CMR for evaluation of HF are unknown. Further, the impact of CMR on subsequent HF patient care is unclear. The goal of this study was to describe the characteristics of patients undergoing CMR for HF and to determine the extent to which CMR leads to changes in downstream patient management by comparing pre-CMR indications and post-CMR diagnoses. METHODS: We utilized the Society for Cardiovascular Magnetic Resonance (SCMR) Registry as our data source and abstracted data for patients undergoing CMR scanning for HF indications from 2013 to 2019. Descriptive statistics (percentages, proportions) were performed on key CMR and clinical variables of the patient population. The Fisher's exact test was used when comparing categorical variables. The Wilcoxon rank sum test was used to compare continuous variables. RESULTS: 3,837 patients were included in our study. 94% of the CMRs were performed in the United States with China, South Korea and India also contributing cases. Median age of HF patients was 59.3 years (IQR, 47.1, 68.3 years) with 67% of the scans occurring on women. Almost 2/3 of the patients were scanned on 3T CMR scanners. Overall, 49% of patients who underwent CMR scanning for HF had a change between the pre-test indication and post CMR diagnosis. 53% of patients undergoing scanning on 3T had a change between the pre-test indication and post CMR diagnosis when compared to 44% of patients who were scanned on 1.5T (p < 0.01). CONCLUSION: Our results suggest a potential impact of CMR scanning on downstream diagnosis of patients referred for CMR for HF, with a larger potential impact on those scanned on 3T CMR scanners.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Femenino , Valor Predictivo de las Pruebas , Espectroscopía de Resonancia Magnética , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Imagen por Resonancia Magnética/métodos , Sistema de Registros
12.
Radiology ; 299(1): 86-96, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33560187

RESUMEN

Background Cardiac diffusion tensor imaging (cDTI) allows for in vivo characterization of myocardial microstructure. In cDTI, mean diffusivity and fractional anisotropy (FA)-markers of magnitude and anisotropy of diffusion of water molecules-are known to change after myocardial infarction. However, little is known about regional changes in helix angle (HA) and secondary eigenvector angle (E2A), which reflects orientations of laminar sheetlets, and their association with long-term recovery of left ventricular ejection fraction (LVEF). Purpose To assess serial changes in cDTI biomarkers in participants following ST-segment elevation myocardial infarction (STEMI) and to determine their associations with long-term left ventricular remodeling. Materials and Methods In this prospective study, 30 participants underwent cardiac MRI (3 T) after STEMI at 5 days and 3 months after reperfusion (National Institute of Health Research study no. 33963 and Research Ethics no. REC17/YH/0062). Spin-echo cDTI with second-order motion-compensation (approximate duration, 13 minutes; three sections; 18 noncollinear diffusion-weighted scans with b values of 100 sec/mm2 [three acquisitions], 200 sec/mm2 [three acquisitions], and 500 sec/mm2 [12 acquisitions]), functional images, and late gadolinium enhancement images were obtained. Multiple regression analysis was used to assess associations between acute cDTI parameters and 3-month LVEF. Results Acutely infarcted myocardium had reduced FA, E2A, and myocytes with right-handed orientation (RHM) on HA maps compared with remote myocardium (mean remote FA = 0.36 ± 0.02 [standard deviation], mean infarcted FA = 0.25 ± 0.03, P < .001; mean remote E2A = 55° ± 9, mean infarcted E2A = 49° ± 10, P < .001; mean remote RHM = 16% ± 6, mean infarcted RHM = 9% ± 5, P < .001). All three parameters (FA, E2A, and RHM) correlated with 3-month LVEF (r = 0.68, r = 0.59, and r = 0.53, respectively), with acute FA being independently predictive of 3-month LVEF (standardized ß = 0.56, P = .008) after multivariable analysis adjusting for factors, including acute LVEF and infarct size. Conclusion After ST-segment elevation myocardial infarction, diffusion becomes more isotropic in acutely infarcted myocardium as reflected by decreased fractional anisotropy. Reductions in secondary eigenvector angle suggest that the myocardial sheetlets are unable to adopt their usual steep orientations in systole, whereas reductions in myocytes with right-handed orientation on helix angle maps are likely reflective of a loss of organization among subendocardial myocytes. Correlations between these parameters and 3-month left ventricular ejection fraction highlight the potential clinical use of cardiac diffusion tensor imaging after myocardial infarction in predicting long-term remodeling. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/patología , Anisotropía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Remodelación Ventricular
13.
Magn Reson Med ; 85(4): 2117-2126, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33048401

RESUMEN

PURPOSE: Diffusion-weighted MRI is sensitive to incoherent tissue motion, which may confound the measured signal and subsequent analysis. We propose a "motion-compensated" gradient waveform design for tensor-valued diffusion encoding that negates the effects bulk motion and incoherent motion in the ballistic regime. METHODS: Motion compensation was achieved by constraining the magnitude of gradient waveform moment vectors. The constraint was incorporated into a numerical optimization framework, along with existing constraints that account for b-tensor shape, hardware restrictions, and concomitant field gradients. We evaluated the efficacy of encoding and motion compensation in simulations, and we demonstrated the approach by linear and planar b-tensor encoding in a healthy heart in vivo. RESULTS: The optimization framework produced asymmetric motion-compensated waveforms that yielded b-tensors of arbitrary shape with improved efficiency compared with previous designs for tensor-valued encoding, and equivalent efficiency to previous designs for linear (conventional) encoding. Technical feasibility was demonstrated in the heart in vivo, showing vastly improved data quality when using motion compensation. The optimization framework is available online in open source. CONCLUSION: Our gradient waveform design is both more flexible and efficient than previous methods, facilitating tensor-valued diffusion encoding in tissues in which motion would otherwise confound the signal. The proposed design exploits asymmetric encoding times, a single refocusing pulse or multiple refocusing pulses, and integrates compensation for concomitant gradient effects throughout the imaging volume.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador , Difusión , Corazón/diagnóstico por imagen , Movimiento (Física)
14.
J Magn Reson Imaging ; 53(1): 73-82, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32558016

RESUMEN

BACKGROUND: Hypertrophic cardiomyopathy (HCM) remains the commonest cause of sudden cardiac death among young athletes. Differentiating between physiologically adaptive left ventricular (LV) hypertrophy observed in athletes' hearts and pathological HCM remains challenging. By quantifying the diffusion of water molecules, diffusion tensor imaging (DTI) MRI allows voxelwise characterization of myocardial microstructure. PURPOSE: To explore microstructural differences between healthy volunteers, athletes, and HCM patients using DTI. STUDY TYPE: Prospective cohort. POPULATION: Twenty healthy volunteers, 20 athletes, and 20 HCM patients. FIELD STRENGTH/SEQUENCE: 3T/DTI spin echo. ASSESSMENT: In-house MatLab software was used to derive mean diffusivity (MD) and fractional anisotropy (FA) as markers of amplitude and anisotropy of the diffusion of water molecules, and secondary eigenvector angles (E2A)-reflecting the orientations of laminar sheetlets. STATISTICAL TESTS: Independent samples t-tests were used to detect statistical significance between any two cohorts. Analysis of variance was utilized for detecting the statistical difference between the three cohorts. Statistical tests were two-tailed. A result was considered statistically significant at P ≤ 0.05. RESULTS: DTI markers were significantly different between HCM, athletes, and volunteers. HCM patients had significantly higher global MD and E2A, and significantly lower FA than athletes and volunteers. (MDHCM = 1.52 ± 0.06 × 10-3 mm2 /s, MDAthletes = 1.49 ± 0.03 × 10-3 mm2 /s, MDvolunteers = 1.47 ± 0.02 × 10-3 mm2 /s, P < 0.05; E2AHCM = 58.8 ± 4°, E2Aathletes = 47 ± 5°, E2Avolunteers = 38.5 ± 7°, P < 0.05; FAHCM = 0.30 ± 0.02, FAAthletes = 0.35 ± 0.02, FAvolunteers = 0.36 ± 0.03, P < 0.05). HCM patients had significantly higher E2A in their thickest segments compared to the remote (E2Athickest = 66.8 ± 7, E2Aremote = 51.2 ± 9, P < 0.05). DATA CONCLUSION: DTI depicts an increase in amplitude and isotropy of diffusion in the myocardium of HCM compared to athletes and volunteers as reflected by increased MD and decreased FA values. While significantly higher E2A values in HCM and athletes reflect steeper configurations of the myocardial sheetlets than in volunteers, HCM patients demonstrated an eccentric rise in E2A in their thickest segments, while athletes demonstrated a concentric rise. Further studies are required to determine the diagnostic capabilities of DTI. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Cardiomiopatía Hipertrófica , Imagen de Difusión Tensora , Atletas , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Humanos , Miocardio , Estudios Prospectivos
15.
J Cardiovasc Magn Reson ; 23(1): 37, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33731141

RESUMEN

BACKGROUND: Adenosine stress perfusion cardiovascular magnetic resonance (CMR) is commonly used in the assessment of patients with suspected ischaemia. Accepted protocols recommend administration of adenosine at a dose of 140 µg/kg/min increased up to 210 µg/kg/min if required. Conventionally, adequate stress has been assessed using change in heart rate, however, recent studies have suggested that these peripheral measurements may not reflect hyperaemia and can be blunted, in particular, in patients with heart failure. This study looked to compare stress myocardial blood flow (MBF) and haemodynamic response with different dosing regimens of adenosine during stress perfusion CMR in patients and healthy controls. METHODS: 20 healthy adult subjects were recruited as controls to compare 3 adenosine perfusion protocols: standard dose (140 µg/kg/min for 4 min), high dose (210 µg/kg/min for 4 min) and long dose (140 µg/kg/min for 8 min). 60 patients with either known or suspected coronary artery disease (CAD) or with heart failure and different degrees of left ventricular (LV) dysfunction underwent adenosine stress with standard and high dose adenosine within the same scan. All studies were carried out on a 3 T CMR scanner. Quantitative global myocardial perfusion and haemodynamic response were compared between doses. RESULTS: In healthy controls, no significant difference was seen in stress MBF between the 3 protocols. In patients with known or suspected CAD, and those with heart failure and mild systolic impairment (LV ejection fraction (LVEF) ≥ 40%) no significant difference was seen in stress MBF between standard and high dose adenosine. In those with LVEF < 40%, there was a significantly higher stress MBF following high dose adenosine compared to standard dose (1.33 ± 0.46 vs 1.10 ± 0.47 ml/g/min, p = 0.004). Non-responders to standard dose adenosine (defined by an increase in heart rate (HR) < 10 bpm) had a significantly higher stress HR following high dose (75 ± 12 vs 70 ± 14 bpm, p = 0.034), but showed no significant difference in stress MBF. CONCLUSIONS: Increasing adenosine dose from 140 to 210 µg/kg/min leads to increased stress MBF in patients with significantly impaired LV systolic function. Adenosine dose in clinical perfusion assessment may need to be increased in these patients.


Asunto(s)
Adenosina/administración & dosificación , Circulación Coronaria , Hiperemia/fisiopatología , Imagen por Resonancia Cinemagnética , Imagen de Perfusión Miocárdica , Vasodilatadores/administración & dosificación , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Volumen Sistólico , Sístole , Disfunción Ventricular Izquierda/fisiopatología
16.
Europace ; 23(23 Suppl 1): i143-i152, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-33751088

RESUMEN

AIMS: Develop, calibrate and evaluate with clinical data a human electromechanical modelling and simulation framework for multiscale, mechanistic investigations in healthy and post-myocardial infarction (MI) conditions, from ionic to clinical biomarkers. METHODS AND RESULTS: Human healthy and post-MI electromechanical simulations were conducted with a novel biventricular model, calibrated and evaluated with experimental and clinical data, including torso/biventricular anatomy from clinical magnetic resonance, state-of-the-art human-based membrane kinetics, excitation-contraction and active tension models, and orthotropic electromechanical coupling. Electromechanical remodelling of the infarct/ischaemic region and the border zone were simulated for ischaemic, acute, and chronic states in a fully transmural anterior infarct and a subendocardial anterior infarct. The results were compared with clinical electrocardiogram and left ventricular ejection fraction (LVEF) data at similar states. Healthy model simulations show LVEF 63%, with 11% peak systolic wall thickening, QRS duration and QT interval of 100 ms and 330 ms. LVEF in ischaemic, acute, and chronic post-MI states were 56%, 51%, and 52%, respectively. In linking the three post-MI simulations, it was apparent that elevated resting potential due to hyperkalaemia in the infarcted region led to ST-segment elevation, while a large repolarization gradient corresponded to T-wave inversion. Mechanically, the chronic stiffening of the infarct region had the benefit of improving systolic function by reducing infarct bulging at the expense of reducing diastolic function by inhibiting inflation. CONCLUSION: Our human-based multiscale modelling and simulation framework enables mechanistic investigations into patho-physiological electrophysiological and mechanical behaviour and can serve as testbed to guide the optimization of pharmacological and electrical therapies.


Asunto(s)
Infarto del Miocardio , Función Ventricular Izquierda , Electrocardiografía , Humanos , Infarto del Miocardio/complicaciones , Volumen Sistólico , Sístole
17.
Eur Heart J ; 41(23): 2168-2179, 2020 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-31834357

RESUMEN

AIMS: ST-elevation myocardial infarction is associated with high levels of cardiac sympathetic drive and release of the co-transmitter neuropeptide Y (NPY). We hypothesized that despite beta-blockade, NPY promotes arrhythmogenesis via ventricular myocyte receptors. METHODS AND RESULTS: In 78 patients treated with primary percutaneous coronary intervention, sustained ventricular tachycardia (VT) or fibrillation (VF) occurred in 6 (7.7%) within 48 h. These patients had significantly (P < 0.05) higher venous NPY levels despite the absence of classical risk factors including late presentation, larger infarct size, and beta-blocker usage. Receiver operating curve identified an NPY threshold of 27.3 pg/mL with a sensitivity of 0.83 and a specificity of 0.71. RT-qPCR demonstrated the presence of NPY mRNA in both human and rat stellate ganglia. In the isolated Langendorff perfused rat heart, prolonged (10 Hz, 2 min) stimulation of the stellate ganglia caused significant NPY release. Despite maximal beta-blockade with metoprolol (10 µmol/L), optical mapping of ventricular voltage and calcium (using RH237 and Rhod2) demonstrated an increase in magnitude and shortening in duration of the calcium transient and a significant lowering of ventricular fibrillation threshold. These effects were prevented by the Y1 receptor antagonist BIBO3304 (1 µmol/L). Neuropeptide Y (250 nmol/L) significantly increased the incidence of VT/VF (60% vs. 10%) during experimental ST-elevation ischaemia and reperfusion compared to control, and this could also be prevented by BIBO3304. CONCLUSIONS: The co-transmitter NPY is released during sympathetic stimulation and acts as a novel arrhythmic trigger. Drugs inhibiting the Y1 receptor work synergistically with beta-blockade as a new anti-arrhythmic therapy.


Asunto(s)
Neuropéptido Y , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Animales , Corazón , Humanos , Ratas , Fibrilación Ventricular
18.
NMR Biomed ; 33(2): e4213, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31765063

RESUMEN

Motion is a major confound in diffusion-weighted imaging (DWI) in the body, and it is a common cause of image artefacts. The effects are particularly severe in cardiac applications, due to the nonrigid cyclical deformation of the myocardium. Spin echo-based DWI commonly employs gradient moment-nulling techniques to desensitise the acquisition to velocity and acceleration, ie, nulling gradient moments up to the 2nd order (M2-nulled). However, current M2-nulled DWI scans are limited to encode diffusion along a single direction at a time. We propose a method for designing b-tensors of arbitrary shapes, including planar, spherical, prolate and oblate tensors, while nulling gradient moments up to the 2nd order and beyond. The design strategy comprises initialising the diffusion encoding gradients in two encoding blocks about the refocusing pulse, followed by appropriate scaling and rotation, which further enables nulling undesired effects of concomitant gradients. Proof-of-concept assessment of in vivo mean diffusivity (MD) was performed using linear and spherical tensor encoding (LTE and STE, respectively) in the hearts of five healthy volunteers. The results of the M2-nulled STE showed that (a) the sequence was robust to cardiac motion, and (b) MD was higher than that acquired using standard M2-nulled LTE, where diffusion-weighting was applied in three orthogonal directions, which may be attributed to the presence of restricted diffusion and microscopic diffusion anisotropy. Provided adequate signal-to-noise ratio, STE could significantly shorten estimation of MD compared with the conventional LTE approach. Importantly, our theoretical analysis and the proposed gradient waveform design may be useful in microstructure imaging beyond diffusion tensor imaging where the effects of motion must be suppressed.


Asunto(s)
Imagen de Difusión Tensora , Corazón/diagnóstico por imagen , Movimiento (Física) , Animales , Difusión , Humanos , Fantasmas de Imagen , Marcadores de Spin , Porcinos
19.
J Cardiovasc Magn Reson ; 22(1): 3, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31915031

RESUMEN

BACKGROUND: Myocardial recovery after primary percutaneous coronary intervention in acute myocardial infarction is variable and the extent and severity of injury are difficult to predict. We sought to investigate the role of cardiovascular magnetic resonance T1 mapping in the determination of myocardial injury very early after treatment of ST-segment elevation myocardial infarction (STEMI). METHODS: STEMI patients underwent 3 T cardiovascular magnetic resonance (CMR), within 3 h of primary percutaneous intervention (PPCI). T1 mapping determined the extent (area-at-risk as %left ventricle, AAR) and severity (average T1 values of AAR) of acute myocardial injury, and related these to late gadolinium enhancement (LGE), and microvascular obstruction (MVO). The characteristics of myocardial injury within 3 h was compared with changes at 24-h to predict final infarct size. RESULTS: Forty patients were included in this study. Patients with average T1 values of AAR ≥1400 ms within 3 h of PPCI had larger LGE at 24-h (33% ±14 vs. 18% ±10, P = 0.003) and at 6-months (27% ±9 vs. 12% ±9; P < 0.001), higher incidence and larger extent of MVO (85% vs. 40%, P = 0.016) & [4.0 (0.5-9.5)% vs. 0 (0-3.0)%, P = 0.025]. The average T1 value was an independent predictor of acute LGE (ß 0.61, 95%CI 0.13 to 1.09; P = 0.015), extent of MVO (ß 0.22, 95%CI 0.03 to 0.41, P = 0.028) and final infarct size (ß 0.63, 95%CI 0.21 to 1.05; P = 0.005). Receiver-operating-characteristic analysis showed that T1 value of AAR obtained within 3-h, but not at 24-h, predicted large infarct size (LGE > 9.5%) with 100% positive predictive value at the optimal cut-off of 1400 ms (area-under-the-curve, AUC 0.88, P = 0.006). CONCLUSION: Hyper-acute T1 values of the AAR (within 3 h post PPCI, but not 24 h) predict a larger extent of MVO and infarct size at both 24 h and 6 months follow-up. Delayed CMR scanning for 24 h could not substitute the significant value of hyper-acute average T1 in determining infarct characteristics.


Asunto(s)
Imagen por Resonancia Cinemagnética , Miocardio/patología , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Anciano , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Meglumina/administración & dosificación , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Prueba de Estudio Conceptual , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/patología , Infarto del Miocardio con Elevación del ST/fisiopatología , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
20.
J Cardiovasc Magn Reson ; 22(1): 58, 2020 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-32772930

RESUMEN

During the peak phase of the COVID-19 pandemic, alterations of standard operating procedures were necessary for health systems to protect patients and healthcare workers and ensure access to vital hospital resources. As the peak phase passes, re-activation plans are required to safely manage increasing clinical volumes. In the context of cardiovascular magnetic resonance (CMR), re-activation objectives include continued performance of urgent CMR studies and resumption of CMR in patients with semi-urgent and elective indications in an environment that is safe for both patients and health care workers.


Asunto(s)
Betacoronavirus , Enfermedades Cardiovasculares/diagnóstico por imagen , Infecciones por Coronavirus/prevención & control , Imagen por Resonancia Magnética/métodos , Pandemias/prevención & control , Neumonía Viral/prevención & control , Guías de Práctica Clínica como Asunto , COVID-19 , Sistema Cardiovascular/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , SARS-CoV-2 , Sociedades Médicas
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda