Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Ann Plast Surg ; 93(2): 172-177, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38775386

RESUMEN

BACKGROUND: Prepectoral breast reconstruction has become increasingly popular over the last decade. There is a paucity of data surrounding the impact of mastectomy type on clinical outcomes when comparing prepectoral immediate breast reconstruction without acellular dermal matrix (ADM) using tissue expansion. The purpose of this study was to compare 90-day reconstructive surgical outcomes in immediate prepectoral tissue expander reconstruction between patients with nipple-sparing mastectomy (NSM) and skin-sparing mastectomy (SSM). METHODS: A retrospective review of patient records was carried out on all patients undergoing NSM or SSM with immediate prepectoral tissue expander reconstruction without ADM, in a single institution, from June 2020 to December 2021. All complications were recorded, categorized, and statistically analyzed for significance. RESULTS: Seventy-nine patients (97 breasts) were studied. The mean age was 51 years old (range, 31-77). Twenty-two patients suffered complications recorded in 22 breasts (22.7%). There was no statistically significant difference in the total complications between the NSM (25.7%) and SSM (21.0%) groups or in the incidence of all major and minor complications. CONCLUSIONS: Breast reconstruction using tissue expanders without ADM has similar reconstructive outcomes in both NSM and SSM. There were no significant differences in complication rates between either groups. Breast reconstruction without ADM can confer institutional cost savings without compromising safety.


Asunto(s)
Dermis Acelular , Neoplasias de la Mama , Mamoplastia , Pezones , Dispositivos de Expansión Tisular , Expansión de Tejido , Humanos , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Mamoplastia/métodos , Anciano , Neoplasias de la Mama/cirugía , Pezones/cirugía , Expansión de Tejido/métodos , Expansión de Tejido/instrumentación , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Mastectomía/métodos , Mastectomía Subcutánea/métodos , Tratamientos Conservadores del Órgano/métodos
2.
Aesthet Surg J ; 44(9): 936-945, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-38518757

RESUMEN

BACKGROUND: Despite increasing demand for breast capsular surgery to treat various benign and malignant implant-related pathologies, high-quality evidence elucidating complication profiles of capsulectomy and capsulotomy is lacking. OBJECTIVES: The aim of this study was to provide the largest-scale analysis of associated outcomes and complications using the Tracking Operations and Outcomes for Plastic Surgeons (TOPS) database, and to investigate clinical scenarios that may subject patients to increased risks for complications, most notably extent of capsular surgery (complete vs partial) and index indication of implantation (aesthetic vs reconstructive). METHODS: An analysis of the TOPS database from 2008 to 2019 was performed. CPT codes were used to identify complete capsulectomy and partial capsulectomy/capsulotomy cases. Breast implant exchange procedures constituted procedural controls. RESULTS: In total, 7486 patients (10,703 breasts) undergoing capsulectomy or capsulotomy were assessed. Relative to controls, capsulectomy (4.40% vs 5.79%), but not capsulotomy (4.40% vs 4.50%), demonstrated higher overall complication rates. Both capsulectomies (0.83% vs 0.23%) and capsulotomies (0.56% vs 0.23%) also had greater rates of seroma relative to controls. Subgroup analyses demonstrated that reconstructive patients, relative to aesthetic patients, experienced greater overall complications (6.76% vs 4.34%), and increased risks for seroma (1.06% vs 0.47%), dehiscence (0.46% vs 0.14%), surgical site infections (1.03% vs 0.23%), and implant loss (0.52% vs 0.23%). A detailed synthesis of 30-day outcomes, including all patient- and breast-specific complications, for both capsulectomy and capsulotomy, stratified according to all potential confounders, is presented herein. CONCLUSIONS: Surgeries on the breast capsule are safe overall, although complete capsulectomies and reconstructive patients are associated with significantly increased operative risks. The present findings will enhance patient selection, counseling, and informed consent.


Asunto(s)
Implantación de Mama , Implantes de Mama , Bases de Datos Factuales , Complicaciones Posoperatorias , Humanos , Femenino , Implantes de Mama/efectos adversos , Implantación de Mama/efectos adversos , Implantación de Mama/métodos , Implantación de Mama/instrumentación , Persona de Mediana Edad , Adulto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Seroma/etiología , Seroma/epidemiología , Estados Unidos/epidemiología , Resultado del Tratamiento , Estética , Adulto Joven
3.
Ann Plast Surg ; 89(3): 261-266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35993683

RESUMEN

BACKGROUND: Adverse events arising in patients with breast implants during mammography reported by the Food and Drug Administration include implant rupture, pain, and impaired visualization. However, data supporting these claims were collected in 2004, and since, newer implant generations have been developed with overall rate of implantation increasing by 48%. OBJECTIVES: This article aims to determine the current incidence of implant-related adverse events arising during mammography. METHODS: We analyzed reports regarding silicone and saline breast implants published in the Food and Drug Administration Manufacturer and User Facility Device Experience database between 2008 and November 2018. Search terms included "mammogram," "mammography," "radiograph," "breast cancer screening," "breast cancer test," and "x-ray." RESULTS: Of the 20 539 implant-related adverse events available in the Manufacturer and User Facility Device Experience database, 427 were retrieved using our search strategy and 41 were related to mammography. Thirty-five of identified cases (85.4%) reported implant rupture, of which 19 (54.3%) were confirmed by a healthcare professional, 9 (25.7%) were clinically confirmed by saline implant deflation, and 7 (20.0%) were unverified reports by patients. Sixteen ruptures (45.7%) occurred with silicone implants, whereas 19 ruptures (54.3%) occurred with saline. Other adverse events included pain (29.3%), change in implant appearance (14.6%), and swelling (7.3%). CONCLUSIONS: Although implant rupture, pain, change in implant appearance, and swelling may occur, minimal implant-related adverse events arise during mammography. Given the extremely low reported risk of implant rupture, this should neither prevent patients from adhering to breast cancer screening programs nor deter patients from seeking breast implants. Patients should be aware of these reported risks and discuss screening options with their breast cancer screening team.


Asunto(s)
Implantes de Mama , Neoplasias de la Mama , Implantes de Mama/efectos adversos , Neoplasias de la Mama/etiología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mamografía , Dolor/etiología , Falla de Prótesis , Siliconas , Estados Unidos , United States Food and Drug Administration
4.
Optom Vis Sci ; 97(10): 852-856, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33055513

RESUMEN

SIGNIFICANCE: Protanopia is a color vision deficiency (CVD) that is unacceptable for certain occupations. This study compares simultaneously for the first time the ability of three recently revised or developed clinical tests of color vision with the Ishihara test to diagnose protanopia from other color vision deficiencies. PURPOSE: The objectives were to examine the ability of four clinical tests to differentiate (1) between protan and deutan CVDs in patients with protanopia and deuteranopia, and (2) protanopes and deuteranopes as "strong" deficiencies. METHODS: The Hardy-Rand-Rittler (4th ed.), City University (3rd ed.), Ishihara, and Mollon-Reffin tests were evaluated against the Oculus Heidelberg Multi-Color anomaloscope for 18 protanopes and 9 deuteranopes. Diagnosis by anomaloscopy was subsequent to administration of screening tests. RESULTS: The Ishihara test misdiagnosed all 18 protanopes as having a deutan deficiency. In contrast, the Hardy-Rand-Rittler and Mollon-Reffin tests correctly identified protan CVD in 100% of protanopes. No screening test was able to reliably diagnose protanopia on the basis of a strong protan CVD. CONCLUSIONS: The Ishihara test is not suitable for screening for protanopia; its failure to diagnose protanopes as having a protan CVD was far greater than that in previous studies. The Hardy-Rand-Rittler and Mollon-Reffin are the most reliable tests for this purpose. None of the screening tests were able to reliably differentiate dichromacy from strongly anomalous trichromacy.


Asunto(s)
Pruebas de Percepción de Colores , Defectos de la Visión Cromática/diagnóstico , Adolescente , Adulto , Niño , Visión de Colores/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
5.
Aesthet Surg J ; 40(1): 78-89, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31152663

RESUMEN

BACKGROUND: Microscopic fat embolism syndrome (micro-FES) has been recently identified as a potentially fatal complication following gluteal augmentation utilizing autologous fat grafts; safety recommendations advocating for subcutaneous lipo-injections may be insufficient for its prevention. OBJECTIVES: The authors of this systematic review evaluated the potential role of corticosteroid prophylaxis for the prevention of micro-FES in gluteal augmentation procedures. METHODS: The authors performed a systematic search employing the National Library of Medicine (PubMed), Medline, and Embase databases. Search terms were those pertaining to studies reporting the efficacy of prophylactic corticosteroid administration on micro-FES incidence in a high-risk surrogate population. RESULTS: Thirteen articles met the inclusion criteria for review, comprising 2 studies reporting on the efficacy of a single intravenous (IV) corticosteroid dose for the prophylaxis of micro-FES, 9 studies reporting on multiple prophylactic IV doses, and 2 additional studies reporting on the efficacy of inhaled corticosteroids in this context. All studies were identified from the orthopedic literature given that none were available directly from within plastic surgery. The prophylactic efficacy of multiple IV doses of methylprednisolone, or a single larger dose, was established, whereas the efficacy of inhaled corticosteroids remains elusive. CONCLUSIONS: A single perioperative IV dose of methylprednisolone may be most appropriate for utilization by plastic surgeons; the safety and implication of this therapy on wound healing and fat graft survival are discussed. Further studies directly evaluating the efficacy of corticosteroid prophylaxis in the gluteal augmentation population are indicated. Finally, recommendations pertaining to the prevention, timely recognition, and effective management of micro-FES are discussed.


Asunto(s)
Contorneado Corporal , Embolia Grasa , Cirugía Plástica , Corticoesteroides/efectos adversos , Embolia Grasa/etiología , Embolia Grasa/prevención & control , Humanos
6.
Ann Plast Surg ; 83(6): e110-e117, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31192870

RESUMEN

BACKGROUND: Suboptimal pain management is a common, yet largely unrecognized, problem in the postsurgical patient population. Current treatment protocols heavily rely on opioid use and, though generally effective in providing pain relief, are associated with multiple side effects. The present systematic review aims to offer plastic surgeons insight into the current state of literature on prolonged local anesthetic wound infusion regimens, evaluating both their efficacy in lowering pain scores and the potential opioid-sparing effect. METHODS: A comprehensive literature search of the Medline, Embase, and Cochrane Library databases was performed to identify relevant studies published between 1980 and December 2017 evaluating the use of prolonged local anesthetic wound infusion for postoperative pain management in plastic surgery. RESULTS: A total of 28 articles were selected, including 3904 patients. The overall infection rate in all patients treated with postsurgical local anesthetic wound infiltration was 0.28% (7/2536). There were no reported cases of systemic toxicity. An opioid-sparing effect was found in 92% (12/13) of studies when compared to an active comparator and 88% (7/8) of those comparing to placebo. Pain scores were decreased in 90% (9/10) of studies comparing wound infiltration to narcotic-based regimens and in 67% (6/9) of those comparing to placebo. CONCLUSIONS: Continuous or intermittent wound infusion is safe and effective in reducing pain scores and opioid consumption in plastic surgery. Though the overall pain-lowering effect appears to be modest, ease of catheter insertion and patient satisfaction make this technique an alluring alternative to more validated approaches such as neuraxial or peripheral nerve blocks.


Asunto(s)
Anestesia Local/métodos , Anestésicos Locales/administración & dosificación , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Cirugía Plástica/métodos , Adulto , Femenino , Humanos , Inyecciones Intralesiones , Masculino , Persona de Mediana Edad , Dimensión del Dolor
7.
J Craniofac Surg ; 30(7): 2111-2114, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31568159

RESUMEN

INTRODUCTION: Despite there being several clinical studies reporting promising outcomes of resorbable plates for fixation of pediatric mandible fractures, the literature is devoid of large studies or comprehensive reviews assessing safety rates, complications and long-term outcomes. The purpose of the current review is to obtain a global consensus, shed light on efficacy and complications, and provide the reader with evidence-based data to help guide clinical management. METHODS: A systematic review of clinical studies assessing outcomes for resorbable plates in pediatric mandibular fractures was carried out. The main outcomes included infection, hardware failure, hardware exposure, malocclusion, reoperation and nonunion. Overall rates were pooled and stratified by fracture and implant type. RESULTS: Ten studies were included yielding 232 patients with 269 fractures. The mean age at surgery was 8.24 years with a mean follow up of 1.03 years. The overall complication rate was 5.2% (n = 12). Complications included infection (n = 4, 1.7%), hardware exposure (n = 3, 1.29%), wound dehiscence (n = 2, .86%) and intra-oral fistula formation (n = 2, .86%). One patient (0.43%) had malocclusion and none (0%) had hardware failure, nonunion or revision surgery. Patients with multiple fractures (≥ 2) had higher complication rates compared to isolated fractures (12.5% versus 1.7%). CONCLUSION: The use of resorbable plates for pediatric mandibular fractures is a viable option with similar rates of post-operative complications and outcomes compared to standard metallic counterparts. In the absence of large studies or systematic reviews, this study provides craniofacial surgeons with an evidence-based reference to guide decision making and improve informed consent.


Asunto(s)
Fracturas Mandibulares/cirugía , Adolescente , Placas Óseas , Niño , Preescolar , Humanos , Lactante , Maloclusión/cirugía , Complicaciones Posoperatorias , Reoperación , Resultado del Tratamiento
8.
Ann Plast Surg ; 78(6S Suppl 5): S279-S281, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28459705

RESUMEN

BACKGROUND: Several procedures have been proposed for the treatment of eyelid ptosis, and both levator advancement and levator plication are widely used to shorten the levator palpebrae superioris. The purpose of this study was to quantify perioperative lid measurements in patients undergoing bilateral levator aponeurosis advancements to aid in preoperative planning. METHODS: Between July 2014 and June 2016, the authors performed a retrospective analysis of all bilateral upper eyelid levator advancement procedures for ptosis performed by the senior surgeon. There are a total of 21 patients (6 men and 15 women) with a mean age of 63 years (range, 48-79 years). The average time at follow-up was 5.3 months, with a range of 1 to 26 months. RESULTS: In this retrospective study, we collected data on presurgical measurements including marginal reflex distance 1 (MRD1), surgical technique used (symmetrical/asymmetrical levator advancement) with millimeters of advancement used, and postsurgical measurements. We found that on average, an advancement of 4 mm led to an improvement in MRD1 of 2.26 mm (n = 14), and advancement of 5 mm led to an improvement in MRD1 of 2.74 mm (n = 15). Patients also reported improvements in their quality of life. CONCLUSIONS: Our results may be used to guide clinicians in preoperative planning.


Asunto(s)
Blefaroplastia/métodos , Blefaroptosis/cirugía , Músculos Oculomotores/cirugía , Planificación de Atención al Paciente , Satisfacción del Paciente , Anciano , Blefaroptosis/diagnóstico , Estudios de Cohortes , Estética , Párpados/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Músculos Oculomotores/fisiopatología , Cuidados Preoperatorios/métodos , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
10.
Ann Transl Med ; 12(1): 8, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38304897

RESUMEN

Lymphedema continues to be a widely prevalent condition with no definitive cure. It affects a wide range of patients across different ages and backgrounds. The significant burden of this chronic and debilitating condition necessitates more research and comprehensive healthcare coverage for affected patients. In developed countries, cancer survivors are disproportionality affected by this condition. Risk factors including lymph node dissections and radiation render many cancer patients more susceptible to the development of lymphedema. Part of the challenge with lymphedema care, is that it exits on a broad spectrum with significant variability of symptoms. Advances and broader availability of various imaging modalities continue to foster progress in lymphedema surgery. The conservative management of lymphedema remains the primary initial management option. However, lymphedema surgeries can provide significant hope and may pave the way for significant improvements in the quality-of-life for many patients afflicted by this progressive and enfeebling condition. Reductive and physiologic procedures are becoming an important part of the armamentarium of the modern plastic and reconstructive surgeon. Recent advances in physiologic lymphedema surgeries are accelerating their transition from experimental surgeries to broadly adopted and widely accepted procedures that can lead to major successes in the fight against this condition. Prophylactic lymphedema surgery also presents a promising choice for many patients and can help prevent lymphedema development in high-risk patients.

11.
Plast Surg (Oakv) ; 32(4): 616-624, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39434810

RESUMEN

Background: In an effort to shed light on the recent resurgence of prepectoral breast reconstruction and mounting concerns regarding acellular dermal matrices (ADMs), the senior author's experience with non-ADM-assisted immediate prepectoral breast reconstruction and its associated complications are presented. Methods: A retrospective cohort study of the senior author's prepectoral breast reconstruction practice without ADM from November 2019 to May 2021 was carried out. Data regarding patient demographics, oncologic management, and surgical outcomes were recorded. Results: A total of 66 patients (88 breasts) were included, with an average follow-up of 7.8 months (SD: 5.4). Of these, 24 (36.4%) underwent immediate expander and 42 (63.6%) direct-to-implant (DTI) reconstructions. Major complications included nipple-areolar complex necrosis (2%), hematoma (3%), device exposure (2%), and periprosthetic infections (5.7%). The overall rate of implant failure was 5.7%. Minor complications included simple cellulitis (10%) and minor wound dehiscence (4.5%). Increasing implant size (p < .005) in the DTI cohort and increasing body mass index (BMI) were associated with an increased likelihood of adverse events. Postmastectomy radiation had no effect on surgical complications. Conclusions: The authors hope that in the absence of large, prospective trials, our data demonstrate the safety of immediate prepectoral breast reconstruction without ADM. Our data demonstrate that our algorithm is particularly safe in patients with a low BMI and with an implant size <500cc in DTI reconstruction. Further large prospective studies are required to further support our data in demonstrating that foregoing ADM in immediate prepectoral reconstruction is a safe option.


Contexte: Dans le but d'éclairer la récente résurgence de la reconstruction mammaire prépectorale et les préoccupations croissantes liées aux matrices dermiques acellulaires (ADM), l'expérience du principal auteur en matière de reconstruction mammaire prépectorale immédiate non assistée par ADM et les complications qui lui sont associées sont présentées ici. Méthodes: Une étude de cohorte rétrospective de reconstruction mammaire prépectorale sans ADM dans la pratique du principal auteur a été menée de novembre 2019 à mai 2021. Les données démographiques des patientes, la gestion oncologique et les résultats chirurgicaux et esthétiques ont été consignés. Résultats: Au total, 66 patientes (88 seins) ont été incluses avec un suivi moyen de 7,8 mois (ÉT : 5,4 mois). Parmi ces patientes, 24 (36,4%) ont eu une expansion immédiate et 42 (63,6%) ont subi des reconstructions par prothèse directe (DTI : direct-to-implant). Les principales complications ont été une nécrose du complexe aréole-mamelon (2%), un hématome (3%), l'exposition du dispositif (2%) et une infection périprothétique (5,6%). Le taux global d'échec des implants a été de 5,6%. Les complications mineures ont été, notamment, une cellulite simple (10%) et une déhiscence mineure de la plaie (4,5%). L'augmentation de la taille de l'implant (P < ,005) dans la cohorte DTI et l'augmentation de l'IMC ont été associées à une plus grande probabilité d'événements indésirables. Une radiothérapie postmastectomie n'a pas eu de répercussions sur les complications chirurgicales. Conclusions: Les auteurs espèrent qu'en l'absence de grandes études prospectives, nos données démontrent l'innocuité de la reconstruction mammaire prépectorale immédiate sans ADM. Nos données démontrent que notre algorithme est particulièrement sécuritaire chez les patientes ayant un IMC faible avec un implant d'une taille < 500cc pour la reconstruction par prothèse directe. Des études prospectives supplémentaires plus grandes sont nécessaires pour soutenir nos données démontrant que l'abandon de l'ADM dans la reconstruction prépectorale immédiate est un choix sécuritaire.

12.
ACS Biomater Sci Eng ; 10(5): 3006-3016, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38640484

RESUMEN

Soft implantable devices are crucial to optimizing form and function for many patients. However, periprosthetic capsule fibrosis is one of the major challenges limiting the use of implants. Currently, little is understood about how spatial and temporal factors influence capsule physiology and how the local capsule environment affects the implant structure. In this work, we analyzed breast implant capsule specimens with staining, immunohistochemistry, and real-time polymerase chain reaction to investigate spatiotemporal differences in inflammation and fibrosis. We demonstrated that in comparison to the anterior capsule against the convex surface of breast implants, the posterior capsule against the flat surface of the breast implant displays several features of a dysregulated foreign body reaction including increased capsule thickness, abnormal extracellular remodeling, and infiltration of macrophages. Furthermore, the expression of pro-inflammatory cytokines increased in the posterior capsule across the lifespan of the device, but not in the anterior capsule. We also analyzed the surface oxidation of breast explant samples with XPS analysis. No significant differences in surface oxidation were identified either spatially or temporally. Collectively, our results support spatiotemporal heterogeneity in inflammation and fibrosis within the breast implant capsule. These findings presented here provide a more detailed picture of the complexity of the foreign body reaction surrounding implants destined for human use and could lead to key research avenues and clinical applications to treat periprosthetic fibrosis and improve device longevity.


Asunto(s)
Implantes de Mama , Fibrosis , Reacción a Cuerpo Extraño , Propiedades de Superficie , Implantes de Mama/efectos adversos , Humanos , Reacción a Cuerpo Extraño/patología , Reacción a Cuerpo Extraño/metabolismo , Reacción a Cuerpo Extraño/inmunología , Femenino , Siliconas/química , Geles de Silicona/efectos adversos , Citocinas/metabolismo , Inflamación/patología , Inflamación/metabolismo , Macrófagos/metabolismo , Macrófagos/inmunología
13.
J Biomed Mater Res A ; 112(12): 2055-2070, 2024 12.
Artículo en Inglés | MEDLINE | ID: mdl-38864257

RESUMEN

The foreign body reaction (FBR) to biomaterials results in fibrous encapsulation. Excessive capsule fibrosis (capsular contracture) is a major challenge to the long-term stability of implants. Clinical data suggests that the tissue type in contact with silicone breast implants alters susceptibility to developing capsular contracture; however, the tissue-specific inflammatory and fibrotic characteristics of capsule have not been well characterized at the cellular and molecular level. In this study, 60 breast implant capsule samples are collected from patients and stratified by the adjacent tissue type including subcutaneous tissue, glandular breast tissue, or muscle tissue. Capsule thickness, collagen organization, immune and fibrotic cellular populations, and expression of inflammatory and fibrotic markers is quantified with histological staining, immunohistochemistry, and real-time PCR. The findings suggest there are significant differences in M1-like macrophages, CD4+ T cells, CD26+ fibroblasts, and expression of IL-1ß, IL-6, TGF-ß, and collagen type 1 depending on the tissue type abutting the implant. Subglandular breast implant capsule displays a significant increase in inflammatory and fibrotic markers. These findings suggest that the tissue microenvironment contributes uniquely to the FBR. This data could provide new avenues for research and clinical applications to improve the site-specific biocompatibility and longevity of implantable devices.


Asunto(s)
Implantes de Mama , Humanos , Implantes de Mama/efectos adversos , Femenino , Adulto , Persona de Mediana Edad , Reacción a Cuerpo Extraño/patología , Fibrosis , Siliconas/química , Geles de Silicona , Macrófagos/metabolismo , Fibroblastos/metabolismo , Mama/patología
14.
Cell Rep ; 43(4): 113988, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38517886

RESUMEN

The basal breast cancer subtype is enriched for triple-negative breast cancer (TNBC) and displays consistent large chromosomal deletions. Here, we characterize evolution and maintenance of chromosome 4p (chr4p) loss in basal breast cancer. Analysis of The Cancer Genome Atlas data shows recurrent deletion of chr4p in basal breast cancer. Phylogenetic analysis of a panel of 23 primary tumor/patient-derived xenograft basal breast cancers reveals early evolution of chr4p deletion. Mechanistically we show that chr4p loss is associated with enhanced proliferation. Gene function studies identify an unknown gene, C4orf19, within chr4p, which suppresses proliferation when overexpressed-a member of the PDCD10-GCKIII kinase module we name PGCKA1. Genome-wide pooled overexpression screens using a barcoded library of human open reading frames identify chromosomal regions, including chr4p, that suppress proliferation when overexpressed in a context-dependent manner, implicating network interactions. Together, these results shed light on the early emergence of complex aneuploid karyotypes involving chr4p and adaptive landscapes shaping breast cancer genomes.


Asunto(s)
Neoplasias de la Mama , Redes Reguladoras de Genes , Humanos , Femenino , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Animales , Ratones , Cromosomas Humanos Par 4/genética , Proliferación Celular/genética , Aberraciones Cromosómicas , Línea Celular Tumoral , Neoplasias de la Mama Triple Negativas/genética , Neoplasias de la Mama Triple Negativas/patología
15.
Plast Reconstr Surg ; 152(4): 699-706, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36827482

RESUMEN

BACKGROUND: Excess fluid accumulation (seroma/hematoma) around the breast implant after reconstruction can lead to significant complications. Topical administration of tranexamic acid (TXA) may reduce fluid accumulation and reduce postoperative complications. This trial aims to investigate whether TXA-treated mastectomy pockets will exhibit less postoperative fluid production and complications. METHODS: This paired, double-blind, randomized, controlled trial enrolled patients undergoing bilateral mastectomies with immediate direct-to-implant reconstruction. In each patient, one breast was randomized to receive 3 g of TXA (100 cc), and the other received 100 cc of normal saline. The blinded solutions were soaked in the mastectomy pocket for 5 minutes before implant placement. Postoperatively, daily drain outputs, complications, and baseline demographics were recorded. RESULTS: Fifty-three eligible patients, representing 106 breasts, were enrolled. All patients underwent bilateral nipple-sparing mastectomies. After randomization, TXA was placed in the right breast in 30 patients (56.6%). The use of topical TXA resulted in a mean drain output reduction of 30.5% (range, -83.6% to 26.6%). Drains on the TXA-treated breast were eligible for removal 1.4 days (range, 0 to 4 days) sooner than the control side. The TXA-treated group had three complications (5.67%) versus 15 (28.3%) in the control group (OR, 0.1920; P = 0.0129). Specifically, for operative hematomas, the TXA group had none (0%), versus three in the control group (5.7%) (OR, 0.1348; P = 0.18). CONCLUSIONS: Soaking the mastectomy bed with 3% topical TXA before implant insertion leads to a decrease in drain output and a decrease in complications. Topical administration of TXA represents an option to decrease complications in alloplastic breast reconstruction. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, I.


Asunto(s)
Antifibrinolíticos , Neoplasias de la Mama , Mamoplastia , Ácido Tranexámico , Humanos , Femenino , Ácido Tranexámico/uso terapéutico , Antifibrinolíticos/uso terapéutico , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/tratamiento farmacológico , Pérdida de Sangre Quirúrgica , Mastectomía/efectos adversos , Transfusión Sanguínea , Administración Tópica , Método Doble Ciego , Hematoma
16.
Arch Ital Urol Androl ; 95(1): 11150, 2023 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-36924371

RESUMEN

INTRODUCTION: Siliconoma represents an inflammatory tissue response to extravasated silicone. Penile enhancing silicone injections have been described for over 50 years. Most of the publications report complications including negative effects on penile appearance and function which require corrective procedures. Penile circumferential skin and siliconoma excision with skin grafting has been described in multiple case reports and series as an effective and feasible option to remove the silicone and achieve good esthetic results. METHODS: We describe a simple and feasible single stage procedure removing the siliconoma with adjacent non-viable skin while preserving 50% of healthy penile skin and resurfacing the defect with a split-thickness skin graft to treat a long-term complication of penile silicone injection associated with recurrent infections and a chronic skin ulceration. CONCLUSION: Partial excision of the affected penile skin and sili-conoma with defect resurfacing with a split-thickness skin graft is a feasible with good functional and cosmetic outcomes.


Asunto(s)
Pene , Trasplante de Piel , Masculino , Humanos , Pene/cirugía , Siliconas
17.
Ann Transl Med ; 11(11): 385, 2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37970601

RESUMEN

Background and Objective: Implant-based breast surgery is a common procedure for both reconstructive and aesthetic purposes. Breast implants, like any foreign object, trigger the formation of a capsule around them. While generally harmless, the capsule can undergo fibrotic changes leading to capsular contracture, which can negatively impact surgical outcomes and patient well-being. Additionally, rare but serious complications, such as breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) and capsule-associated squamous cell carcinoma, have been reported. This paper aims to review the physiology of capsular formation, identify factors contributing to capsule-related pathologies, and discuss their clinical implications. Methods: A review of relevant literature was conducted by searching databases for articles published between inception and September 2022. The search included but not limited to terms such as "capsular formation" and "capsular contracture". Selected articles were critically analyzed to address the objectives of this review. Key Content and Findings: Capsular formation involves interactions between the implant surface, surrounding tissues, and the immune system. Factors influencing pathological changes in the capsule include genetic predisposition, bacterial contamination, implant characteristics, and surgical techniques. Capsular contracture, characterized by tissue hardening, pain, and implant distortion, remains the most common complication. Rare but life-threatening conditions, such as BIA-ALCL and capsule-associated squamous cell carcinoma, necessitate vigilant monitoring and early detection. Conclusions: Understanding the physiology of capsular formation and its associated pathologies is crucial for healthcare providers involved in implant-based breast surgery. Efforts should focus on minimizing the risk of capsular contracture through improved implant materials, surgical techniques, and infection prevention. The emergence of BIA-ALCL and capsule-associated squamous cell carcinoma underscores the importance of long-term surveillance and prompt diagnosis. Further research is needed to uncover underlying mechanisms and develop preventive measures and treatments for these complications. Enhancing our knowledge and clinical management of capsular formation will lead to safer and more successful outcomes in implant-based breast surgery.

18.
Plast Reconstr Surg ; 150(4): 903e-908e, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35939647

RESUMEN

SUMMARY: Mindfulness has recently been implemented by advanced military combatants, firefighters, and those in other very intellectually demanding and fast-paced professions. A surgeon, similarly, is faced with many difficult challenges, whether it be a complex and meticulous surgery, extensive clinical responsibilities, or simply the challenges faced in residency. In current curricula, there is no training to introspectively deal with these stressors. Regardless of what we face in our personal lives, the lives of patients are literately in our hands. Would it not be prudent and wise to train our brain to not only deliver care to our patients but also be able to take care of us and maybe even improve our performance? Regular practice of mindfulness has been shown to decrease rates of burnout, decrease medical errors, improve sleep, and even improve surgical performance. With the ever-changing pandemic situation and increasing stressors in the hospital, mindful meditation is perfectly primed to be added to our armamentarium as surgeons and physicians. This review aims to explain how mindfulness can enhance a surgeon's performance, mindset, interactions, and execution through a review of recent scientific advancements and evidence.


Asunto(s)
Agotamiento Profesional , Meditación , Atención Plena , Cirujanos , Encéfalo , Humanos
19.
J Plast Reconstr Aesthet Surg ; 75(4): 1328-1341, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35181248

RESUMEN

BACKGROUND: Plastic surgeons' firm grasp of perforator anatomy allows them to be increasingly mindful of esthetic outcomes, patient satisfaction, and donor-site function when approaching breast reconstruction. Mindfulness of these outcomes has contributed to the widespread use of locoregional perforator flaps in post-mastectomy and post-BCS reconstruction. METHODS: A literature search of the PubMed database was performed to identify relevant studies reporting the use of locoregional perforator flaps in post-mastectomy breast reconstruction. Selected manuscripts were analyzed and grouped by pedicled flap category. Articles were additionally assessed for the advantages and disadvantages of each flap and reported complications. RESULTS: Following three rounds of review, 30 of 101 (29.7%) articles were retained as specifically pertinent to the use of locoregional flaps in breast reconstruction surgery. They were categorized by locoregional perforator flap used (TDAP, LICAP, AICAP, LTAP, or IMAP). In total, the included studies reported on the use of perforator flaps in 829 patients, with complications occurring in 73 of 418 patients (17.5%). Commonly reported complications across all included studies were hematomas (n = 10), infection (n = 7), fat necrosis/steatofibrosis (n = 31), extruded expanders (n = 1), dehiscence (n = 2), seroma (n = 2), required cosmetic correction of the donor area (n = 5), flap congestion (n = 11), flap failure (n = 2), poor esthetic outcome (n = 4), grade II capsular contracture (n = 3, all of whom received postoperative radiation), and keloid scars(n = 1). CONCLUSIONS: Though the available literature remains anecdotal, locoregional flap-based reconstruction may provide some benefit in post-BCS reconstruction by sparing donor-site musculature and nerve supply and by minimizing adverse events.


Asunto(s)
Neoplasias de la Mama , Mamoplastia , Colgajo Perforante , Algoritmos , Neoplasias de la Mama/etiología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mamoplastia/efectos adversos , Mastectomía , Estudios Retrospectivos
20.
Aesthet Surg J Open Forum ; 4: ojac025, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35747463

RESUMEN

Background: Although plastic surgeons commonly perform capsulectomies for a variety of peri-prosthetic capsular conditions, the safety of capsulectomy remains unknown, and the literature lacks evidence describing its morbidity and complication rates for patients inquiring about its associated risks. Objectives: The present study aims to identify and define the complication rates associated with capsulectomies. Methods: An analysis of the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database was performed between the years 2015 and 2018. All information pertaining to demographics, patient-related information, surgical indications, procedure-related information, outcomes, and complications were assessed. Results: The study identified 2231 cases of surgeon-reported capsulectomies; indications most commonly reported included capsular contracture (n = 638, 28.6%) and breast implant rupture (n = 403, 18.1%). In total, 141 patients (6.32%) were hospitalized for longer than 1 postoperative day (range, 2-28 days), while the overall complication rate was 3.0% (n = 67/2231 patients). Incidence of minor complications, representing superficial surgical site infections, was 0.8%, while the major complication rate was 2.24%. These included 7 cases of deep surgical site infections (0.3%), 19 organ space infections (0.9%), and 8 cases of wound dehiscence (0.4%). Eight patients developed sepsis (0.4%); 6 patients required transfusions (0.3%); 1 case of postoperative pneumonia and 1 myocardial infarction were also identified (n = 1 each, 0.0%). The overall reoperation and readmission rates were 2.0%, representing a readmission rate of 66% among patients with complications. Conclusions: The present study provides the first estimate of the incidence of complications associated with capsulectomies. Although the NSQIP database contains significant limitations, the data presented herein describe a complication profile that plastic surgeons can share with their patients during informed consent.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda