Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Nature ; 600(7890): 636-640, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34937893

RESUMEN

Superconductivity originates from the formation of bound (Cooper) pairs of electrons that can move through the lattice without resistance below the superconducting transition temperature Tc (ref. 1). Electron Cooper pairs in most superconductors form anti-parallel spin singlets with total spin S = 0 (ref. 2), although they can also form parallel spin-triplet Cooper pairs with S = 1 and an odd parity wavefunction3. Spin-triplet pairing is important because it can host topological states and Majorana fermions relevant for quantum computation4,5. Because spin-triplet pairing is usually mediated by ferromagnetic (FM) spin fluctuations3, uranium-based materials near an FM instability are considered to be ideal candidates for realizing spin-triplet superconductivity6. Indeed, UTe2, which has a Tc ≈ 1.6 K (refs. 7,8), has been identified as a candidate for a chiral spin-triplet topological superconductor near an FM instability7-14, although it also has antiferromagnetic (AF) spin fluctuations15,16. Here we use inelastic neutron scattering (INS) to show that superconductivity in UTe2 is coupled to a sharp magnetic excitation, termed resonance17-23, at the Brillouin zone boundary near AF order. Because the resonance has only been found in spin-singlet unconventional superconductors near an AF instability17-23, its observation in UTe2 suggests that AF spin fluctuations may also induce spin-triplet pairing24 or that electron pairing in UTe2 has a spin-singlet component.

2.
Proc Natl Acad Sci U S A ; 120(8): e2216367120, 2023 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-36791111

RESUMEN

Recently, evidence for a conducting surface state (CSS) below 19 K was reported for the correlated d-electron small gap semiconductor FeSi. In the work reported herein, the CSS and the bulk phase of FeSi were probed via electrical resistivity ρ measurements as a function of temperature T, magnetic field B to 60 T, and pressure P to 7.6 GPa, and by means of a magnetic field-modulated microwave spectroscopy (MFMMS) technique. The properties of FeSi were also compared with those of the Kondo insulator SmB6 to address the question of whether FeSi is a d-electron analogue of an f-electron Kondo insulator and, in addition, a "topological Kondo insulator" (TKI). The overall behavior of the magnetoresistance of FeSi at temperatures above and below the onset temperature TS = 19 K of the CSS is similar to that of SmB6. The two energy gaps, inferred from the ρ(T) data in the semiconducting regime, increase with pressure up to about 7 GPa, followed by a drop which coincides with a sharp suppression of TS. Several studies of ρ(T) under pressure on SmB6 reveal behavior similar to that of FeSi in which the two energy gaps vanish at a critical pressure near the pressure at which TS vanishes, although the energy gaps in SmB6 initially decrease with pressure, whereas in FeSi they increase with pressure. The MFMMS measurements showed a sharp feature at TS ≈ 19 K for FeSi, which could be due to ferromagnetic ordering of the CSS. However, no such feature was observed at TS ≈ 4.5 K for SmB6.

3.
Clin Chem Lab Med ; 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38687473

RESUMEN

OBJECTIVES: Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients. METHODS: Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems. The inter- and intra-laboratory %CV were calculated and compared. To determine the source of the substantial inter-laboratory %CV, laboratories were categorized according to the measurement systems they are using, and both the inter- and intra-measurement-system %CV were calculated and compared. RESULTS: Regarding renin, the majority of laboratories use four primary commercial immunoassays. However, for aldosterone, in addition to commercial immunoassays, laboratory-developed liquid chromatography-tandem mass spectrometry (LC-MS) methods are also used by laboratories. The median values of intra-laboratory %CVs, intra-measurement-system %CVs, inter-laboratory %CVs, and inter-measurement systems %CVs varied between 1.6 and 2.6 %, 4.6 and 14.9 %, 8.3 and 25.7 %, and 10.0 and 34.4 % for renin, respectively. For aldosterone, these values ranged from 1.4 to 2.2 %, 2.5-14.7 %, 9.9-31.0 %, and 10.0-35.5 %, respectively. CONCLUSIONS: The precision within laboratories and measurement systems for plasma renin and aldosterone measurements is satisfactory. However, the comparability between laboratories using different measurement systems remains lacking, indicating the long way to achieve standardization and harmonization for these two analytes.

4.
BMC Genomics ; 24(1): 248, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37165306

RESUMEN

BACKGROUND: Real-time quantitative PCR (RT-qPCR) is a crucial and widely used method for gene expression analysis. Selecting suitable reference genes is extremely important for the accuracy of RT-qPCR results. Commonly used reference genes are not always stable in various organisms or under different environmental conditions. With the increasing application of high-throughput sequencing, transcriptome analysis has become an effective method for identifying novel stable reference genes. RESULTS: In this study, we identified candidate reference genes based on transcriptome data covering embryos and larvae of early development, normal adult tissues, and the hindgut under sulfide stress using the coefficient of variation (CV) method in the echiuran Urechis unicinctus, resulting in 6834 (15.82%), 7110 (16.85%) and 13880 (35.87%) candidate reference genes, respectively. Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analyses revealed that the candidate reference genes were significantly enriched in cellular metabolic process, protein metabolic process and ribosome in early development and normal adult tissues as well as in cellular localization and endocytosis in the hindgut under sulfide stress. Subsequently, ten genes including five new candidate reference genes and five commonly used reference genes, were validated by RT-qPCR. The expression stability of the ten genes was analyzed using four methods (geNorm, NormFinder, BestKeeper, and ∆Ct). The comprehensive results indicated that the new candidate reference genes were more stable than most commonly used reference genes. The commonly used ACTB was the most unstable gene. The candidate reference genes STX12, EHMT1, and LYAG were the most stable genes in early development, normal adult tissues, and hindgut under sulfide stress, respectively. The log2(TPM) of the transcriptome data was significantly negatively correlated with the Ct values of RT-qPCR (Ct = - 0.5405 log2(TPM) + 34.51), which made it possible to estimate the Ct value before RT-qPCR using transcriptome data. CONCLUSION: Our study is the first to select reference genes for RT-qPCR from transcriptome data in Echiura and provides important information for future gene expression studies in U. unicinctus.


Asunto(s)
Poliquetos , Transcriptoma , Animales , Perfilación de la Expresión Génica , Poliquetos/genética , Sulfuros/metabolismo , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Estándares de Referencia
5.
Clin Chem Lab Med ; 61(9): 1597-1604, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37141618

RESUMEN

OBJECTIVES: To find suitable external quality assessment (EQA) materials for serum C-peptide, we evaluated the commutability of five types of processed materials. METHODS: Seventy-four individual serum samples and 12 processed samples including three EQA samples currently in use, frozen human serum pools (FHSP), and three other kinds of processed samples were prepared by dissolving WHO International Standard Reagent for C-peptide (WHO ISR 13/146) in three different matrixes: 0.05 % bovine serum albumin, fetal bovine serum and human serum pools. Samples were analyzed using the isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method and six widely used immunoassays. The commutabilities of processed materials were assessed according to the difference in bias approach recommended by the IFCC. And the short- and long-term stability of FHSP samples at different temperatures were also evaluated. RESULTS: Out of the five kinds of processed materials, FHSP samples were commutable on most assays. In contrast, the EQA materials currently in use were only commutable on a few immunoassays. Additionally, processed materials derived from WHO ISR 13/146 were found to be un-commutable on over half of immunoassays. The FHSP samples could be stably stored at 4 and -20 °C for at least 16 days, and at -80 °C for at least 1 year, but at room temperature only for 12 h. CONCLUSIONS: With clarified commutability and stability information, the human serum pool samples along with the developed ID-LC-MS/MS method could be used in the EQA program to promote the comparability among laboratories for C-peptide measurement in China.


Asunto(s)
Laboratorios , Espectrometría de Masas en Tándem , Humanos , Péptido C , Cromatografía Liquida , Sesgo , Estándares de Referencia
6.
J Nanobiotechnology ; 21(1): 380, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37848990

RESUMEN

BACKGROUND: The prevalence of coronary artery disease is increasing. As a common treatment method, coronary artery bypass transplantation surgery can improve heart problems while also causing corresponding complications. Venous graft restenosis is one of the most critical and intractable complications. Stem cell-derived exosomes could have therapeutic promise and value. However, as exosomes alone are prone to inactivation and easy removal, this therapeutic method has not been widely used in clinical practice. Methacrylated gelatin (GelMA) is a polymer with a loose porous structure that maintains the biological activity of the exosome and can control its slow release in vivo. In this study, we combined human umbilical cord mesenchymal stem cell-derived exosomes (hUCMSC-Exos) and GelMA to explore their effects and underlying mechanisms in inhibiting venous graft restenosis. RESULTS: Human umbilical cord mesenchymal stem cells (hUCMSCs) were appraised using flow cytometry. hUCMSC-Exos were evaluated via transmission electron microscopy and western blotting. hUCMSC-Exos embedded in a photosensitive GelMA hydrogel (GelMA-Exos) were applied topically around venous grafts in a rat model of cervical arteriovenous transplantation, and their effects on graft reendothelialization and restenosis were evaluated through ultrasonic, histological, and immunofluorescence examinations. Additionally, we analyzed the material properties, cellular reactions, and biocompatibility of the hydrogels. We further demonstrated that the topical application of GelMA-Exos could accelerate reendothelialization after autologous vein transplantation and reduce restenosis in the rat model. Notably, GelMA-Exos caused neither damage to major organs in mice nor excessive immune rejection. The uptake of GelMA-Exos by endothelial cells stimulated cell proliferation and migration in vitro. A bioinformatic analysis of existing databases revealed that various cell proliferation and apoptosis pathways, including the mammalian target of rapamycin (mTOR)-phosphoinositide 3-kinase (PI3K)-AKT signaling pathways, might participate in the underlying regulatory mechanism. CONCLUSIONS: Compared with the tail vein injection of hUCMSC-Exos, the local application of a mixture of hUCMSC-Exos and GelMA was more effective in promoting endothelial repair of the vein graft and inhibiting restenosis. Therefore, the proposed biomaterial-based therapeutic approach is a promising treatment for venous graft restenosis.


Asunto(s)
Exosomas , Células Madre Mesenquimatosas , Ratas , Humanos , Ratones , Animales , Gelatina , Exosomas/metabolismo , Células Endoteliales , Fosfatidilinositol 3-Quinasas/metabolismo , Cordón Umbilical , Células Endoteliales de la Vena Umbilical Humana , Mamíferos
7.
Molecules ; 28(23)2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38067608

RESUMEN

Volatile organic compounds (VOCs) and flavor characteristics of Rosa roxburghii Tratt. (RR) and Rosa sterilis (RS) were analyzed using headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry (HS-SPME-GC-MS). The flavor network was constructed by combining relative odor activity values (ROAVs), and the signature differential flavor components were screened using orthogonal partial least squares discriminant analysis (OPLS-DA) and random forest (RF). The results showed that 61 VOCs were detected in both RR and RS: 48 in RR, and 26 in RS. There were six key flavor components (ROAVs ≥ 1) in RR, namely nonanal, ethyl butanoate, ethyl hexanoate, (3Z)-3-hexen-1-yl acetate, ethyl caprylate, and styrene, among which ethyl butanoate had the highest contribution, whereas there were eight key flavor components (ROAVs ≥ 1) in RS, namely 2-nonanol, (E)-2-hexenal, nonanal, methyl salicylate, ß-ocimene, caryophyllene, α-ionone, and styrene, among which nonanal contributed the most to RS. The flavor of RR is primarily fruity, sweet, green banana, and waxy, while the flavor of RS is primarily sweet and floral. In addition, OPLS-DA and RF suggested that (E)-2-hexenal, ethyl caprylate, ß-ocimene, and ethyl butanoate could be the signature differential flavor components for distinguishing between RR and RS. In this study, the differences in VOCs between RR and RS were analyzed to provide a basis for further development and utilization.


Asunto(s)
Rosa , Compuestos Orgánicos Volátiles , Cromatografía de Gases y Espectrometría de Masas/métodos , Microextracción en Fase Sólida/métodos , Odorantes/análisis , Compuestos Orgánicos Volátiles/análisis , Estirenos
8.
Scand J Clin Lab Invest ; 82(7-8): 556-562, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36300737

RESUMEN

Accurate therapeutic drug monitoring (TDM) of vancomycin, meropenem, linezolid and teicoplanin are conducive to developing optimal therapeutic regimes for patients. However, the measurement status of those drugs in different laboratories has not been reported. In this study, four samples including two frozen plasma samples and two lyophilized plasma samples were measured by over 35 laboratories across China. The inter- and intra-laboratory %CV, biases (%) of laboratories and intra- and inter-measurement-system %CV were calculated and analyzed. The short-term stability and homogeneity of those drugs in samples were studied. The results of frozen and lyophilized samples were also compared to determine whether there were significant differences in their matrix effects on various measurement systems. Results showed most laboratories' intra-laboratory %CVs were less than 9% for all drugs, and the mean inter-laboratory %CVs were 18.4%, 86.4%, 19.1% and 37.1% for vancomycin, meropenem, linezolid and teicoplanin measurements, respectively. For vancomycin, the intra-measurement %CV of commercial measurement systems was found to be smaller than that of other measurement systems. For meropenem, linezolid and teicoplanin, the agreement among laboratories using self-developed methods (Liquid chromatography-mass spectrometry [LC-MS] or high-performance liquid chromatography [HPLC]) was not satisfactory as most intra-measurement system CVs% were over 20%. Drugs in lyophilized samples were found to be more stable than in frozen samples, and no obvious differences in matrix effects were found for those two kinds of processed samples on most measurement systems. In conclusion, this study depicted the measurement status of those drugs in clinical laboratories, and found the lyophilized samples were more suitable EQA material for those drugs.


Asunto(s)
Antibacterianos , Vancomicina , Humanos , Antibacterianos/uso terapéutico , Linezolid , Meropenem , Teicoplanina , Monitoreo de Drogas/métodos
9.
Anal Bioanal Chem ; 413(30): 7509-7520, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34643770

RESUMEN

Accurate measurement of plasma metanephrines (MNs) including metanephrine (MN) and normetanephrine (NMN) is crucial for the screening and diagnosis in pheochromocytomas and paragangliomas (PPGLs). Although the number of laboratories using liquid chromatography tandem mass spectrometry (LC-MS/MS) method to measure MNs has been increasing rapidly, those laboratory-developed assays showed incomparable results. There are no reference measurement procedures (RMPs) or reference materials (RMs) for MNs in Joint Committee for Traceability in Laboratory Medicine (JCTLM), which hindered the standardization of MNs measurement. We established a candidate RMP (cRMP) based on isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for plasma MNs measurement. Plasma samples were spiked with MN-D3 and NMN-D3 as internal standards; protein precipitation and ion-exchange solid phase extraction (SPE) were performed to extract samples, eventually analyzed by LC-MS/MS. The cRMP was applied to evaluate two routine ID-LC/MS/MS methods through split-sample comparisons. Fifty-three individual patient samples were determined by cRMP and two routine ID-LC/MS/MS methods; results were analyzed by ordinary linear regression and Bland-Altman plots. The cRMP exhibited desirable imprecision, with intra-run and total imprecision (coefficient variation, CV) for MN being 0.79-1.36% and 1.53-1.87% and for NMN being 1.10-1.34% and 1.15-1.64%. The analytical recoveries of MN and NMN ranged from 98.3 to 101.7% and from 98.5 to 101.9%, respectively. Significant calibrator biases and sample-specific deviations were observed in method comparison. An accurate, precise, and reliable cRMP for plasma MNs was developed, and RMs with value assigned following the cRMP would help minimize the calibration bias and improve the comparability of different measuring systems.


Asunto(s)
Cromatografía Liquida/métodos , Metanefrina/sangre , Calibración , Humanos , Técnicas de Dilución del Indicador , Límite de Detección , Metanefrina/normas , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem
10.
Scand J Clin Lab Invest ; 81(3): 218-224, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33755506

RESUMEN

The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) published the reference measurement procedure (RMP) for ALP measurement in 2011. However, the RMP is of high requirements for laboratories, complicated, time-consuming and high cost of reagents. Many manufacturers do not trace results to the higher procedure. And there is currently no designated comparison method (DCM) for ALP measurement. Thus, the standardization of ALP measurement is hindered. Automatic biochemical analyzers are easy to operate and widely used in clinical laboratories. Therefore, according to the RMP, establishing a DCM based on an automatic biochemical analyzer will be a practical way to establish traceability to the accuracy base and promote the standardization of ALP measurement. On the basis of conforming to the RMP recommended by IFCC as far as possible, the DCM was established based on a Thermo Indiko automatic biochemical analyzer. Performances of the method were validated. The DCM repeatability and within laboratory imprecision was <1% and <2.5%, respectively. For evaluation of trueness, the biases were within the equivalent limits. Measurement procedure comparisons and biases estimation were carried out between the DCM, the RMP, and the six routine methods using a panel of 40 individual human serum samples. The comparisons between the DCM and the RMP gave satisfying results. Compared with the DCM, the relative biases of some routine methods failed to meet the bias limit derived from biological variation.


Asunto(s)
Fosfatasa Alcalina/sangre , Análisis Químico de la Sangre/métodos , Análisis Químico de la Sangre/instrumentación , Análisis Químico de la Sangre/normas , Humanos , Laboratorios Clínicos/normas , Reproducibilidad de los Resultados
11.
Animals (Basel) ; 14(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38473138

RESUMEN

A total of 20 healthy white × landrace sows were evenly and randomly divided into two groups, and fed basal diets unsupplemented or supplemented with 500 g/t Meriden-Stim® from day 100 of gestation until day 21 of lactation. Serum and fecal samples were collected from the sows on the final day for subsequent analysis. Compared to the control group, there were no significant differences in the sows' performances; however, an increase was observed in the piglets' weight at weaning (p = 0.08). Moreover, oregano essential oil (OEO) significantly reduced the levels of urea (UREA) (p < 0.01), total cholesterol (TC) (p < 0.05), low-density lipoprotein (LDL-C) (p < 0.05) and alanine aminotransferase (ALT) (p < 0.05) in serum. In terms of antioxidant indexes in serum, the catalase (CAT) and glutathione (GSH) levels showed significant increases (p < 0.05) while the malondialdehyde (MDA) level exhibited a decrease tendency (p = 0.09). 16S rRNA analysis identified the specific bacteria taxa in feces. OEO significantly decreased the relative abundance of Proteobacteria and Actinobacteria at the phylum level (p < 0.05). At the genus level, OEO significantly increased the relative abundance of Lactobacillus and Prevotellaceae UCG 003 and UCG 005, while decreasing that of Escherichia-Shigella (p < 0.05). Taken together, OEO supplementation in maternal diets during late gestation and lactation improved serum metabolites, antioxidant capacity and regulated the intestinal-flora balance of sows, thereby tending to increase the piglets' weight at weaning.

12.
Ann Lab Med ; 43(4): 345-354, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-36843403

RESUMEN

Background: Serum C-peptide results from various routine methods used in China are highly variable, warranting well-performing methods to serve as an accuracy base to improve the harmonization of C-peptide measurements in China. We developed an accurate isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method for serum C-peptide measurement and explored its use in harmonization. Methods: After protein precipitation with ZnSO4 solution, C-peptide was extracted from serum samples by anion-exchange solid-phase extraction and quantified by ID-LC-MS/MS in positive ion mode. The precision and analytical recovery of the ID-LC-MS/MS method were assessed. Seventy-six serum samples were analyzed using the ID-LC-MS/MS method and six routine immunoassays. Ordinary linear regression (OLR) and Bland-Altman (BA) analyses were conducted to evaluate the relationship between the ID-LC-MS/MS method and routine immunoassays. Five serum pool samples assigned using the ID-LC-MS/MS method were used to recalibrate the routine assays. OLR and BA analyses were re-conducted after recalibration. Results: The within-run, between-run, and total precision for the ID-LC-MS/MS method at four concentrations were 1.0%-2.1%, 0.6%-1.2%, and 1.3%-2.2%, respectively. The analytical recoveries for the ID-LC-MS/MS method at three concentrations were 100.3%-100.7%, 100.4%-101.0%, and 99.6%-100.7%. The developed method and the immunoassays were strongly correlated, with all R2 >0.98. The comparability among the immunoassays was substantially improved after recalibration. Conclusions: The performance of the ID-LC-MS/MS method was carefully validated, and this method can be used to improve the harmonization of serum C-peptide measurements in China.


Asunto(s)
Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Péptido C , Técnicas de Dilución del Indicador , Inmunoensayo/métodos
13.
Ann Clin Biochem ; 60(3): 199-207, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36750430

RESUMEN

BACKGROUND: Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools' commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated. METHODS: Insulin in 69 individual serum samples, 10 serum pools, and three EQA samples (lyophilized powder of serum pools) were detected by six widely used immunoassays. The commutability of serum pools and EQA samples was evaluated according to the IFCC-recommended approach. Serum pools' stability at different temperatures was investigated by placing them at various temperatures for varying lengths of time. Individual serum samples' results were analyzed using the Bland-Altman and Passing and Bablok regression analyses. RESULTS: Serum pools were commutable among most assays, the EQA samples-lyophilized serum pools-were non-commutable among most assays. Serum pools can be stably stored at -20°C and -80°C for at least one year, but can only be stably stored at room temperature for twenty-four hours. Significant relative differences were observed among assays. Recalibration using serum pools can only improve the assays' agreement at middle and high insulin levels, but not at low levels. CONCLUSIONS: Serum pools were commutable and stable for insulin measurement and can be used in insulin harmonization. The existing EQA materials were non-commutable between most assays, and other EQA materials, such as serum pools, should be studied.


Asunto(s)
Bioensayo , Insulina , Humanos , Inmunoensayo , Estándares de Referencia
14.
Ann Lab Med ; 42(4): 428-437, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35177563

RESUMEN

BACKGROUND: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. METHODS: Patient serum samples were pooled into five groups according to insulin and C-peptide concentrations and measured in 94 laboratories using different measurement systems. The inter- and intra-laboratory %CV as well as inter- and intra-measurement system %CV were calculated to assess the status of insulin and C-peptide measurements. To verify whether the disagreement between laboratories was due to different calibrators, as reported in previous studies, one low-level and one high-level sample extracted from the five pooled serum samples were used to recalibrate clinical measurement systems. RESULTS: The mean intra-laboratory, intra-measurement system, inter-laboratory, and inter-measurement system %CVs were 2.7%, 4.8%, 21.8%, and 22.4%, respectively, for insulin and 2.3%, 6.7%, 16.4%, and 24.5%, respectively, for C-peptide. The inter- and intra-laboratory %CVs for insulin decreased with increasing concentration. After recalibration with low- and high-level samples, the mean inter-measurement %CV decreased from 22.4% to 17.2% for insulin and from 24.5% to 5.7% for C-peptide. CONCLUSIONS: The intra-laboratory and intra-measurement system imprecision values are satisfactory for serum insulin and C-peptide measurements. However, the results from laboratories using different measurement systems were not comparable, and there is still much work needed to achieve the standardization or harmonization of serum insulin and C-peptide measurements.


Asunto(s)
Servicios de Laboratorio Clínico , Laboratorios , Péptido C , Humanos , Laboratorios Clínicos , Estándares de Referencia
15.
Antioxidants (Basel) ; 11(9)2022 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-36139880

RESUMEN

Studies have shown that Periplaneta americana extract (PAE) has good therapeutic effects in inflammatory disorders such as ulcerative colitis, alcoholic hepatitis, and gastric ulcers. However, whether or not PAE has good pre-protective effects has not been widely and deeply studied. In this study, we investigated the effects of PAE pretreatment for 7 days on oxidative stress and inflammation triggered by oxidative stress by using diquat-induced C57BL/6 mice as an oxidative stress model. The results showed that PAE pretreatment could significantly reduce oxidative stress in the intestine and liver by reducing the production of MDA, and improved antioxidant systems (SOD, CAT, GSH, and T-AOC). By primarily activating the anti-inflammatory cytokine (IL-10) mediated JAK1/STAT3 signaling pathway, PAE also effectively reduced oxidative stress-induced liver inflammation while also reducing liver damage, as evidenced by the reductions in serum AST and ALT. PAE pretreatment also had a significant effect on maintaining the intestinal barrier function, which was manifested by inhibiting a decrease in the expression of tight junction proteins (ZO-1 and occludin), and reducing the increased intestinal permeability (serum DAO and D-Lac) caused by diquat. The 16S rRNA sequencing analysis revealed that diquat decreased the gut microbiota diversity index and increased the abundance of pathogenic bacteria (e.g., Allobaculum, Providencia and Escherichia-Shigella), while PAE pretreatment responded to diquat-induced damage by greatly increasing the abundance of Akkermansia muciniphila. These findings elucidate potential pre-protective mechanisms of PAE in alleviating oxidative stress and inflammation, while providing a direction for the treatment of metabolic diseases by utilizing PAE to enhance the abundance of gut A. muciniphila.

16.
Ann Lab Med ; 42(5): 575-584, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35470275

RESUMEN

Background: To identify candidate external quality assessment (EQA) materials for normetanephrine and metanephrine measurements, we assessed the commutability of eight processed human plasma samples. The agreement between routine assays and the candidate reference measurement procedure (cRMP) was also evaluated. Methods: Fifty-three clinical samples and eight processed plasma samples were prepared. The processed samples included pooled and individual plasma samples spiked with pure normetanephrine and metanephrine and non-spiked pooled and individual plasma samples. The clinical and processed samples were subjected to four routine isotope dilution tandem mass spectrometry assays and cRMP. Commutability was assessed based on two approaches recommended by the CLSI and International Federation of Clinical Chemistry (IFCC). Passing-Bablok regression and Bland-Altman analysis were used to evaluate the agreement between the routine assays and cRMP. Results: The commutability results of the CLSI approach were better than those of the IFCC approach. For the CLSI approach, spiked individual plasma samples and spiked high-concentration pooled plasma samples were commutable for all routine assays for both analytes. The non-spiked pooled plasma sample was commutable for two out of four routine assays for metanephrine and three out of four routine assays for normetanephrine. The agreement between the routine assays and the cRMP was satisfactory, except for one routine assay showing significant bias. Conclusions: High-concentration spiked pooled plasma samples and spiked individual plasma samples are candidate EQA materials for normetanephrine and metanephrine measurements.


Asunto(s)
Metanefrina , Normetanefrina , Pruebas Hematológicas , Humanos , Espectrometría de Masas
17.
Clin Biochem ; 104: 44-50, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35331753

RESUMEN

BACKGROUND: Accurate TDMs of plasma methotrexate, imatinib and paclitaxel assist in the development of optimal therapeutic regimes. This study aims to investigate the current status of methotrexate, imatinib and paclitaxel measurements in China and explore the suitable EQA materials for those drugs. METHODS: 4 processed plasma samples including 2 levels of frozen pooled plasma samples and 2 levels of lyophilized pooled plasma samples were measured in different laboratories using different measurement systems. The inter-laboratory %CV and intra-measurement-system %CV of laboratories were calculated to assess the status of methotrexate, imatinib and paclitaxel measurements. The short-term stability and homogeneity of those processed samples were studied and compared. The relative differences (%) between the results of those two kinds of processed samples were also calculated to determine whether there were significant differences in their matrix effects for various measurement systems. RESULTS: The mean inter-laboratory %CVs ranged from 12.8% to 15.3%, 14.7% to 19.6% and 56.8% to 81.6% for methotrexate, imatinib and paclitaxel, respectively. The intra-measurement %CV of homogeneous commercial measurement systems was better than other measurement systems. The lyophilized samples were more stable than frozen samples and there were no obvious differences in their matrix effects for most measurement systems. CONCLUSIONS: The agreement among the results of methotrexate, imatinib, and especially paclitaxel from different laboratories was not satisfactory. Currently, the lyophilized samples were the more suitable EQA material for methotrexate, imatinib and paclitaxel than frozen samples.


Asunto(s)
Monitoreo de Drogas , Metotrexato , Monitoreo de Drogas/métodos , Humanos , Mesilato de Imatinib , Laboratorios , Paclitaxel
18.
Front Cardiovasc Med ; 9: 1009165, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36578834

RESUMEN

Objective: Fetal cardiopulmonary bypass (CPB) is essential to fetal heart surgery, while its development is limited by vital organ dysfunction after CPB. Studying organ metabolism may help to solve this problem. The objective of this study was to describe the tissue-specific metabolic fingerprints of fetal sheep under CPB and to associate them with organ functions. Methods: Ten pregnant ewes at 90-120 days of gestation were randomly divided into two groups. The bypass group underwent a 1-h fetal CPB, whereas the control group underwent only a fetal sternotomy. During bypass, echocardiography, blood gases, and blood biochemistry were measured. After bypass, lambs were sacrificed, and tissues of the heart, liver, brain, kidney, and placenta were harvested. The metabolites extracted from these tissues were analyzed using non-targeted metabolomics based on liquid chromatography-mass spectrometry techniques. Results: All tissues except the placenta displayed significant metabolic changes, and the fetal heart displayed obvious functional changes. Fetal sheep that underwent CPB had common and tissue-specific metabolic signatures. These changes can be attributed to dysregulated lipid metabolism, altered amino acid metabolism, and the accumulation of plasticizer metabolism. Conclusion: Fetal CPB causes tissue-specific metabolic changes in fetal sheep. Studying these metabolic changes, especially cardiac metabolism, is of great significance for the study of fetal CPB.

19.
Front Neurol ; 13: 988854, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36061997

RESUMEN

To determine the possible role of matrix metallopeptidase (MMP)-8 and MMP-9 in the development of chronic subdural hematoma (CSDH), we investigated their expression in CSDH. In our previous study, we analyzed hematoma fluid and peripheral blood of 83 patients with CSDH, including 17 postoperative patients. Based on these results, we included 50 people in the normal group and analyzed 20 markers in the peripheral blood of each person. In order to identify representative markers, it was assessed by using overall differential gene expression. The concentration of MMP-8 was significantly higher in the normal group than that in the preoperative and postoperative groups. The concentration of MMP-9 was significantly lower in the normal group than in both preoperative and postoperative groups. Immunohistochemistry confirmed the expression of MMP-8 and MMP-9 in CSDH membranes. In conclusion, our results provide evidence of the expression of MMP-8 and MMP-9 in CSDH. In addition, the expression of MMP-8 and MMP-9 suggests angiogenesis in CSDH formation.

20.
J Mass Spectrom Adv Clin Lab ; 21: 1-9, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34820671

RESUMEN

Human C-peptide is secreted in equimolar amounts with insulin by pancreatic beta-cells. Measurement of C-peptide plays an important role in the diagnosis and treatment of diabetes where it is used to evaluate the function of islet cells. However, C-peptide measurement results across different laboratories vary considerably and there is an urgent need to improve comparability between laboratories. As it is sensitive and specific, isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) has made a major contribution and will continue to play a significant role in the standardization of C-peptide measurement. Here, we reviewed the application of ID-LC-MS/MS in C-peptide measurement by discussing the biochemical properties of C-peptide, common sample preparation procedures, and the sensitivity problems often encountered with ID-LC-MS/MS C-peptide measurement. Collectively, these factors are crucial for the development of ID-LC-MS/MS methods for C-peptide measurement. We also discussed the advantages, disadvantages, and progress of implementing ID-LC-MS/MS as a routine measurement tool for C-peptide in clinical laboratories. Finally, we summarized the existing reference system and the status of C-peptide measurement in clinical laboratories to convey the necessity of improving the comparability of C-peptide measurement in clinical laboratories using ID-LC-MS/MS.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda