Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Indoor Air ; 28(2): 318-338, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28960493

RESUMEN

Worldwide, public policies are promoting energy-efficient buildings and accelerating the thermal renovation of existing buildings. The effects of these changes on the indoor air quality (IAQ) in these buildings remain insufficiently understood. In this context, a field study was conducted in 72 energy-efficient dwellings to describe the pollutants known to be associated with health concerns. Measured parameters included the concentrations of 19 volatile organic compounds and aldehydes, nitrogen dioxide, particulate matter (PM2.5 ), radon, temperature, and relative humidity. The air stuffiness index and night-time air exchange rate were calculated from the monitored carbon dioxide (CO2 ) concentrations. Indoor and outdoor measurements were performed at each dwelling during 1 week in each of the two following seasons: heating and non-heating. Moreover, questionnaires were completed by the occupants to characterize the building, equipment, household, and occupants' habits. Perspective on our results was provided by previous measurements made in low-energy European dwellings. Statistical comparisons with the French housing stock and a pilot study showed higher concentrations of terpenes, that is, alpha-pinene and limonene, and hexaldehyde in our study than in previous studies. Alpha-pinene and hexaldehyde are emitted by wood or wood-based products used for the construction, insulation, decoration, and furnishings of the dwellings, whereas limonene is more associated with discontinuous sources related to human activities.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Conservación de los Recursos Energéticos , Monitoreo del Ambiente/estadística & datos numéricos , Vivienda/normas , Monitoreo del Ambiente/métodos , Francia , Calefacción , Humanos , Humedad , Material Particulado/análisis , Proyectos Piloto , Radón/análisis , Estaciones del Año , Temperatura , Compuestos Orgánicos Volátiles/análisis
2.
Indoor Air ; 27(6): 1168-1176, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28474814

RESUMEN

Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM10 and PM2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Vivienda/estadística & datos numéricos , Percepción , Francia , Humanos , Fumar , Encuestas y Cuestionarios
3.
Indoor Air ; 27(1): 114-127, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-26880519

RESUMEN

The contamination of indoor environments with chemical compounds released by materials and furniture, such as semi-volatile organic compounds (SVOCs), is less documented in schools than in dwellings-yet children spend 16% of their time in schools, where they can also be exposed. This study is one of the first to describe the contamination of the air and dust of 90 classrooms from 30 nursery and primary schools by 55 SVOCs, including pesticides, phosphoric esters, musks, polycyclic aromatic hydrocarbons (PAHs), polychlorobiphenyls (PCBs), phthalates, and polybromodiphenylethers (PBDEs). Air samples were collected using an active sampling method, and dust samples were collected via two sampling methods (wiping and vacuum cleaning). In air, the highest concentrations (median >100 ng/m3 ) were measured for diisobutyl phthalate (DiBP), dibutyl phthalate (DBP), diethyl phthalate (DEP), bis(2-ethylhexyl) phthalate (DEHP), and galaxolide. In dust, the highest concentrations (median >30 µg/g) were found for DEHP, diisononyl phthalate (DiNP), DiBP, and DBP. An attempt to compare two floor dust sampling methods using a single unit (ng/m²) was carried out. SVOC concentrations were higher in wiped dust, but frequencies of quantification were greater in vacuumed dust.


Asunto(s)
Contaminación del Aire Interior/análisis , Polvo/análisis , Exposición a Riesgos Ambientales/análisis , Instituciones Académicas , Compuestos Orgánicos Volátiles/análisis , Niño , Preescolar , Dibutil Ftalato/análogos & derivados , Dibutil Ftalato/análisis , Ácidos Grasos Monoinsaturados/análisis , Pisos y Cubiertas de Piso , Francia , Humanos , Organofosfatos/análisis , Plaguicidas/análisis , Ácidos Ftálicos/análisis , Proyectos Piloto , Bifenilos Polibrominados/análisis , Bifenilos Policlorados/análisis , Hidrocarburos Policíclicos Aromáticos/análisis
4.
Indoor Air ; 26(3): 350-65, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-25955661

RESUMEN

The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2 ), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non-heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Ventilación/estadística & datos numéricos , Aldehídos/análisis , Dióxido de Carbono/análisis , Monitoreo del Ambiente/métodos , Francia , Humedad , Casas Cuna , Material Particulado/análisis , Instituciones Académicas , Estaciones del Año , Temperatura , Ventilación/métodos , Compuestos Orgánicos Volátiles/análisis
5.
Ann Pharm Fr ; 70(4): 204-12, 2012 Jul.
Artículo en Francés | MEDLINE | ID: mdl-22818262

RESUMEN

This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice).


Asunto(s)
Contaminación del Aire Interior/análisis , Contaminación del Aire/análisis , Monitoreo del Ambiente , Francia , Humanos , Actividades Recreativas , Instituciones Académicas , Deportes , Piscinas , Ventilación , Lugar de Trabajo
6.
Rev Mal Respir ; 35(6): 659-672, 2018 Jun.
Artículo en Francés | MEDLINE | ID: mdl-29937314

RESUMEN

Children exposure to molds in the school and preschool environment is not well described in France. A nationwide survey was performed in 2009-2011 in 310 schools and nurseries from France including two oversea territories, Reunion and Martinique. It showed that 5 % of the audited rooms had visible molds, mainly on the ceiling. These rooms belonged to 34 buildings (11 %). The multivariate analysis shows that several factors are associated with visible molds in rooms: the presence of textile wall covering, the location of the building in a suburban area, the size of the building (less visible molds in large buildings), the absence of a ventilation system with exhaust located in the room, and the absence of double-glazed windows. The prevalence of visible molds is comparable to the one observed in large European studies: 7 % of the 334 classrooms in the frame of the SINPHONIE project and 11 % of the buildings in 193 elementary schools in the HITEA study.


Asunto(s)
Contaminación del Aire Interior/estadística & datos numéricos , Hongos/fisiología , Casas Cuna/estadística & datos numéricos , Instituciones Académicas/estadística & datos numéricos , Adolescente , Microbiología del Aire/normas , Niño , Preescolar , Francia/epidemiología , Hongos/crecimiento & desarrollo , Humanos , Martinica/epidemiología , Casas Cuna/normas , Prevalencia , Estudios Retrospectivos , Reunión/epidemiología , Instituciones Académicas/normas , Ventilación/métodos , Ventilación/normas
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda