Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Small ; 20(20): e2307956, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38143295

RESUMEN

A cross-comparison of three stop-flow configurations-such as low-pressure (LSF), high-pressure open-circuit (OC-HSF), and high-pressure short-circuit (SC-HSF) stop-flow-is presented to rapidly bring a high velocity flow O(m s-1) within a microchannel to a standstill O(µm s-1). The performance of three stop-flow configurations is assessed by measuring residual flow velocities within microchannels having three orders of magnitude different flow resistances. The LSF configuration outperforms the OC-HSF and SC-HSF configurations within a high flow resistance microchannel and results in a residual velocity of <10 µm s-1. The OC-HSF configuration results in a residual velocity of <150 µm s-1 within a low flow resistance microchannel. The SC-HSF configuration results in a residual velocity of <200 µm s-1 across the three orders-of-magnitude different flow resistance microchannels, and <100 µm s-1 for the low flow resistance channel. It is hypothesized that residual velocity results from compliance in fluidic circuits, which is further investigated by varying the elasticity of microchannel walls and connecting tubing. A numerical model is developed to estimate the expanded volumes of the compliant microchannel and connecting tubings under a pressure gradient and to calculate the distance traveled by the sample fluid. A comparison of the numerically and experimentally obtained traveling distances confirms the hypothesis that the residual velocities are an outcome of the compliance in the fluidic circuit.

2.
Macromol Rapid Commun ; 45(13): e2300721, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38615246

RESUMEN

Crescent-shaped hydrogel microparticles are shown to template uniform volume aqueous droplets upon simple mixing with aqueous and oil media for various bioassays. This emerging "lab on a particle" technique requires hydrogel particles with tunable material properties and dimensions. The crescent shape of the particles is attained by aqueous two-phase separation of polymers followed by photopolymerization of the curable precursor. In this work, the phase separation of poly(ethylene glycol) diacrylate (PEGDA, Mw 700) and dextran (Mw 40 000) for tunable manufacturing of crescent-shaped particles is investigated. The particles' morphology is precisely tuned by following a phase diagram, varying the UV intensity, and adjusting the flow rates of various streams. The fabricated particles with variable dimensions encapsulate uniform aqueous droplets upon mixing with an oil phase. The particles are fluorescently labeled with red and blue emitting dyes at variable concentrations to produce six color-coded particles. The blue fluorescent dye shows a moderate response to the pH change. The fluorescently labeled particles are able to tolerate an extremely acidic solution (pH 1) but disintegrate within an extremely basic solution (pH 14). The particle-templated droplets are able to effectively retain the disintegrating particle and the fluorescent signal at pH 14.


Asunto(s)
Dextranos , Tamaño de la Partícula , Polietilenglicoles , Polietilenglicoles/química , Dextranos/química , Concentración de Iones de Hidrógeno , Hidrogeles/química , Hidrogeles/síntesis química , Propiedades de Superficie , Colorantes Fluorescentes/química , Polimerizacion , Agua/química
3.
Anal Chem ; 93(4): 2317-2326, 2021 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-33410663

RESUMEN

Simple mixing of aqueous and oil solutions with amphiphilic particles leads to the spontaneous formation of uniform reaction volumes (dropicles) that can enable numerous applications in the analysis of biological entities (e.g., cells and molecules). Approaches to manufacture such amphiphilic particles are just starting to be investigated. Here, we investigate the tunable manufacturing of concentric amphiphilic particles, with outer hydrophobic and inner hydrophilic layers, fabricated by flowing reactive precursor streams through a 3D printed device with coaxial microfluidic channels, and curing the structured flow by UV exposure through a photomask. The dimensions of the engineered amphiphilic particles, including height, inner and outer diameters, and thicknesses of the hydrophobic and hydrophilic layers, are precisely controlled by modulating the UV exposure time, the precursor flow rate ratios, and the size of the channel in the exposure region. The particle design is systematically engineered to hold a wide range of droplet volumes, that is, from a few hundred picoliters to several nanoliters. We show that the particle size can be significantly reduced from previous reports to not only hold subnanoliter drops but the shape can also be tuned to increase the seeding density and orientation of dropicles within a well plate for imaging and analysis.

4.
Anal Chem ; 90(14): 8546-8552, 2018 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-29911381

RESUMEN

Sheathless focusing and separation of microparticles is an important preprocessing step in various biochemical assays in which enriched sample isolation is critical. Most of the previous microfluidic particle separation techniques have used sheath flows to achieve efficient sample focusing. The sheath flow dilutes the analyte and requires additional microchannels and accurate flow control. We demonstrated a tilted-angle traveling surface acoustic wave (taTSAW)-based sheathless focusing and separation of particles in a continuous flow. The proposed device consists of a piezoelectric substrate with a pair of interdigitated transducers (IDTs) deposited at two different angles relative to the flow direction. A Y-shaped polydimethylsiloxane (PDMS) microchannel having one inlet and two outlet ports was positioned on top of the IDTs such that the acoustic energy coupling into the fluid was maximized and wave attenuation by the PDMS walls was minimized. The two IDTs independently produced high-frequency taTSAWs, which propagated at ±30° with respect to the flow direction and imparted a direct acoustic radiation force onto the target particles. A sample mixture of 4.8 and 3.2 µm particles was focused and then separated by the actuation of the IDTs at 194 and 136 MHz frequencies, respectively, without using an additional sheath flow. The proposed taTSAW-based particle separation device offered a high purity >99% at the both outlets over a wide range of flow speeds (up to 83.3 mm/s).

5.
Anal Chem ; 89(4): 2211-2215, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28192923

RESUMEN

We demonstrate an acoustofluidic platform that uses surface acoustic waves (SAWs) for the facile capture of droplets inside microwells and their on-demand release. When the ac signal applied to the device is tuned to modulate the location of the SAW, the SAW-based acoustic radiation force retracts or pushes the droplets into or out of one of three microwells fabricated inside a microchannel to selectively capture or release the droplet.

6.
Anal Chem ; 89(1): 736-744, 2017 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-27959499

RESUMEN

A sessile droplet of water carrying polystyrene microparticles of different diameters was uniformly exposed to high frequency surface acoustic waves (SAWs) produced by an interdigitated transducer (IDT). We investigated the concentration behavior of the microparticles as the SAWs generated a strong acoustic streaming flow (ASF) inside the water droplet and exerted a direct acoustic radiation force (ARF) on the suspended particles, the magnitude of which depended upon the particle diameter. As a result of the ARF, the microparticles were concentrated according to their diameters at different positions inside the sessile droplet placed in the path of the SAW, right in front of the IDT. The microparticle concentration behavior changed as the sessile droplet contact angle with the substrate was varied by adding surfactant to the water or by gradually evaporating the water. The positions at which the smaller and larger microparticles were concentrated remained distinguishable, even at very different experimental conditions. The long-term exposure of the droplets to the SAWs was accompanied by the gradual evaporation of the carrier fluid, which dynamically changed the droplet contact angle as well as the concentration of particles. Complete evaporation of the fluid left behind several concentrated yet separated clusters of particles on the substrate surface. The effect of the droplet contact angle on particles' concentration behavior and consequent separation of particles has been uniquely studied in this SAW-based report.

7.
Anal Chem ; 89(24): 13575-13581, 2017 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-29156880

RESUMEN

We have designed a pumpless acoustofluidic device for the concentration and separation of different sized particles inside a single-layered straight polydimethylsiloxane (PDMS) microfluidic channel. The proposed device comprises two parallel interdigitated transducers (IDTs) positioned underneath the PDMS microchannel. The IDTs produce high-frequency surface acoustic waves that generate semipermeable virtual acoustic radiation force field walls that selectively trap and concentrate larger particles at different locations inside the microchannel and allow the smaller particles to pass through the acoustic filter. The performance of the acoustofluidic device was first characterized by injecting into the microchannel a uniform flow of suspended 9.9 µm diameter particles with various initial concentrations (as low as 10 particles/mL) using a syringe pump. The particles were trapped with ∼100% efficiency by a single IDT actuated at 73 MHz. The acoustofluidic platform was used to demonstrate the pumpless separation of 12.0, 4.8, and 2.1 µm microparticles by trapping the 12 and 4.8 µm particles using the two IDTs actuated at 73 and 140 MHz, respectively. However, most of the 2.1 µm particles flowed over the IDTs unaffected. The acoustofluidic device was capable of rapidly processing a large volume of sample fluid pumped through the microchannel using an external syringe pump. A small volume of the sample fluid was processed through the device using a capillary flow and a hydrodynamic pressure difference that did not require an external pumping device.

8.
Anal Chem ; 89(24): 13313-13319, 2017 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-29148722

RESUMEN

We developed a hybrid microfluidic device that utilized acoustic waves to drive functionalized microparticles inside a continuous flow microchannel and to separate particle-conjugated target proteins from a complex fluid. The acoustofluidic device is composed of an interdigitated transducer that produces high-frequency surface acoustic waves (SAW) and a polydimethylsiloxane (PDMS) microfluidic channel. The SAW interacted with the sample fluid inside the microchannel and deflected particles from their original streamlines to achieve separation. Streptavidin-functionalized polystyrene (PS) microparticles were used to capture aptamer (single-stranded DNA) labeled at one end with a biotin molecule. The free end of the customized aptamer15 (apt15), which was attached to the microparticles via streptavidin-biotin linkage to form the PS-apt15 conjugate, was used to capture the model target protein, thrombin (th), by binding at exosite I to form the PS-apt15-th complex. We demonstrated that the PS-apt15 conjugate selectively captured thrombin molecules in a complex fluid. After the PS-apt15-th complex was formed, the sample fluid was pumped through a PDMS microchannel along with two buffer sheath flows that hydrodynamically focused the sample flow prior to SAW exposure for PS-apt15-th separation from the non-target proteins. We successfully separated thrombin from mCardinal2 and human serum using the proposed acoustofluidic device.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Analíticas Microfluídicas , Sonido , Trombina/aislamiento & purificación , Biotina/química , Dimetilpolisiloxanos/química , Humanos , Tamaño de la Partícula , Poliestirenos/química , Estreptavidina/química , Propiedades de Superficie , Trombina/química
9.
Anal Chem ; 88(7): 3976-81, 2016 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-26937678

RESUMEN

We demonstrate an acoustofluidic device using Lamb waves (LWs) to manipulate polystyrene (PS) microparticles suspended in a sessile droplet of water. The LW-based acoustofluidic platform used in this study is advantageous in that the device is actuated over a range of frequencies without changing the device structure or electrode pattern. In addition, the device is simple to operate and cheap to fabricate. The LWs, produced on a piezoelectric substrate, attenuate inside the fluid and create acoustic streaming flow (ASF) in the form of a poloidal flow with toroidal vortices. The PS particles experience direct acoustic radiation force (ARF) in addition to being influenced by the ASF, which drive the concentration of particles to form a ring. This phenomenon was previously attributed to the ASF alone, but the present experimental results confirm that the ARF plays an important role in forming the particle ring, which would not be possible in the presence of only the ASF. We used a range of actuation frequencies (45-280 MHz), PS particle diameters (1-10 µm), and droplet volumes (5, 7.5, and 10 µL) to experimentally demonstrate this phenomenon.

10.
Anal Chem ; 88(8): 4205-10, 2016 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-27049167

RESUMEN

Engineering inertial lift forces and elastic lift forces is explored to transfer microparticles across laminar streams from non-Newtonian to Newtonian fluid. A co-stream of non-Newtonian flow loaded with microparticles (9.9 and 2.0 µm in diameter) and a Newtonian carrier medium flow in a straight rectangular conduit is devised. The elastic lift forces present in the non-Newtonian fluid, undeterred by particle-particle interaction, successfully pass most of the larger (9.9 µm) particles over to the Newtonian fluid. The Newtonian fluid takes over the larger particles and focus them on the equilibrium position, separating the larger particles from the smaller particles. This mechanism enabled processing of densely suspended particle samples. The method offers dilution-free (for number densities up to 10,000 µL(-1)), high throughput (6700 beads/s), and highly efficient (>99% recovery rate, >97% purity) particle separation operated over a wide range of flow rate (2 orders of magnitude).

11.
Anal Chem ; 87(22): 11568-74, 2015 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-26487447

RESUMEN

Temperature gradients (TGs) provide an effective approach to controlling solvated molecules and creating spatiotemporally varying thermal stimuli for biochemical research. Methods developed to date for generating TGs can only create a limited set of static temperature profiles. This article describes a method for establishing dynamic free-form TGs in polydimethylsiloxane (PDMS) as well as in gases and liquids in contact with the PDMS. The heating mechanism relies on the efficient acoustic absorption by the PDMS of high-frequency (5-200 MHz) surface acoustic waves (SAWs). MATLAB-aided actuation of a transducer enabled the generation and propagation of SAWs in a controlled fashion, which permitted spatiotemporal control over the temperature in the PDMS microstructures. This technique is exploited to perform one-shot high-resolution melting (HRM) analysis to detect single nucleotide polymorphisms (SNPs) in DNA. The experimental results displayed a 10-fold higher resolution and an enhanced signal-to-noise ratio compared to the results obtained using a conventional real-time PCR machine.


Asunto(s)
Equipos Desechables , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Temperatura , ADN/genética , Análisis Mutacional de ADN , Dimetilpolisiloxanos/química , Desnaturalización de Ácido Nucleico , Polimorfismo de Nucleótido Simple/genética
12.
Anal Chem ; 87(9): 4627-32, 2015 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-25800052

RESUMEN

We demonstrate a miniaturized acoustofluidic device composed of a pair of slanted interdigitated transducers (SIDTs) and a polydimethylsiloxane microchannel for achieving size-selective separation and exchange of medium around polystyrene particles in a continuous, label-free, and contactless fashion. The SIDTs, deposited parallel to each other, produce tunable traveling surface acoustic waves (TSAWs) at desired locations, which, in turn, yield an anechoic corner inside the microchannel that is used to selectively deflect particles of choice from their streamlines. The TSAWs with frequency fR originating from the right SIDT and propagating left toward the microchannel normal to the fluid flow direction, laterally deflect larger particles with diameter d1 from the hydrodynamically focused sample fluid that carries other particles as well with diameters d2 and d3, such that d1 > d2 > d3. The deflected particles (d1) are pushed into the top-left corner of the microchannel. Downstream, the TSAWs with frequency fL, such that fL > fR, disseminating from the left SIDT, deflect the medium-sized particles (d2) rightward, leaving behind the larger particles (d1) unaffected in the top-left anechoic corner and the smaller particles (d3) in the middle of the microchannel, thereby achieving particle separation. A particle not present in the anechoic corner could be deflected rightward to realize twice the medium exchange. In this work, the three-way separation of polystyrene particles with diameters of 3, 4.2, and 5 µm and 3, 5, and 7 µm is achieved using two separate devices. Moreover, these devices are used to demonstrate multimedium exchange around polystyrene particles ∼5 µm and 7 µm in diameter.

13.
Discov Nano ; 18(1): 18, 2023 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-36800044

RESUMEN

Recent years have witnessed an increased interest in the development of nanoparticles (NPs) owing to their potential use in a wide variety of biomedical applications, including drug delivery, imaging agents, gene therapy, and vaccines, where recently, lipid nanoparticle mRNA-based vaccines were developed to prevent SARS-CoV-2 causing COVID-19. NPs typically fall into two broad categories: organic and inorganic. Organic NPs mainly include lipid-based and polymer-based nanoparticles, such as liposomes, solid lipid nanoparticles, polymersomes, dendrimers, and polymer micelles. Gold and silver NPs, iron oxide NPs, quantum dots, and carbon and silica-based nanomaterials make up the bulk of the inorganic NPs. These NPs are prepared using a variety of top-down and bottom-up approaches. Microfluidics provide an attractive synthesis alternative and is advantageous compared to the conventional bulk methods. The microfluidic mixing-based production methods offer better control in achieving the desired size, morphology, shape, size distribution, and surface properties of the synthesized NPs. The technology also exhibits excellent process repeatability, fast handling, less sample usage, and yields greater encapsulation efficiencies. In this article, we provide a comprehensive review of the microfluidic-based passive and active mixing techniques for NP synthesis, and their latest developments. Additionally, a summary of microfluidic devices used for NP production is presented. Nonetheless, despite significant advancements in the experimental procedures, complete details of a nanoparticle-based system cannot be deduced from the experiments alone, and thus, multiscale computer simulations are utilized to perform systematic investigations. The work also details the most common multiscale simulation methods and their advancements in unveiling critical mechanisms involved in nanoparticle synthesis and the interaction of nanoparticles with other entities, especially in biomedical and therapeutic systems. Finally, an analysis is provided on the challenges in microfluidics related to nanoparticle synthesis and applications, and the future perspectives, such as large-scale NP synthesis, and hybrid formulations and devices.

14.
ACS Nano ; 17(20): 19952-19960, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37824510

RESUMEN

Compartmentalization, leveraging microfluidics, enables highly sensitive assays, but the requirement for significant infrastructure for their design, build, and operation limits access. Multimaterial particle-based technologies thermodynamically stabilize monodisperse droplets as individual reaction compartments with simple liquid handling steps, precluding the need for expensive microfluidic equipment. Here, we further improve the accessibility of this lab on a particle technology to resource-limited settings by combining this assay system with a portable multimodal reader, thus enabling nanoliter droplet assays in an accessible platform. We show the utility of this platform in measuring N-terminal propeptide B-type natriuretic peptide (NT-proBNP), a heart failure biomarker, in complex medium and patient samples. We report a limit of detection of ∼0.05 ng/mL and a linear response between 0.2 and 2 ng/mL in spiked plasma samples. We also show that, owing to the plurality of measurements per sample, "swarm" sensing acquires better statistical quantitation with a portable reader. Monte Carlo simulations show the increasing capability of this platform to differentiate between negative and positive samples, i.e., below or above the clinical cutoff for acute heart failure (∼0.1 ng/mL), as a function of the number of particles measured. Our platform measurements correlate with gold standard ELISA measurement in cardiac patient samples, and achieve lower variation in measurement across samples compared to the standard well plate-based ELISA. Thus, we show the capabilities of a cost-effective droplet-reader system in accurately measuring biomarkers in nanoliter droplets for diseases that disproportionately affect underserved communities in resource-limited settings.


Asunto(s)
Insuficiencia Cardíaca , Microfluídica , Humanos , Biomarcadores/análisis , Vasodilatadores , Ensayo de Inmunoadsorción Enzimática , Insuficiencia Cardíaca/diagnóstico
15.
Ultrason Sonochem ; 89: 106161, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36088893

RESUMEN

Surface acoustic wave (SAW)-based acoustofluidics has shown significant promise to manipulate micro/nanoscale objects for biomedical applications, e.g. cell separation, enrichment, and sorting. A majority of the acoustofluidic devices utilize microchannels with rectangular cross-section where the acoustic waves propagate in the direction perpendicular to the sample flow. A region with weak acoustic wave intensity, termed microchannel anechoic corner (MAC), is formed inside a rectangular microchannel of the acoustofluidic devices where the ultrasonic waves refract into the fluid at the Rayleigh angle with respect to the normal to the substrate. Due to the absence of a strong acoustic field within the MAC, the microparticles flowing adjacent to the microchannel wall remain unaffected by a direct SAW-induced acoustic radiation force (ARF). Moreover, an acoustic streaming flow (ASF) vortex produced within the MAC pulls the particles further into the corner and away from the direct ARF influence. Therefore, a residue of particles continues to flow past the SAWs without intended deflection, causing a decrease in microparticle manipulation efficiency. In this work, we introduce a cross-type acoustofluidic device composed of a half-circular microchannel, fabricated through a thermal reflow of a positive photoresist mold, to overcome the limitations associated with rectangular microchannels, prone to the MAC formation. We investigated the effects of different microchannel cross-sectional shapes with varying contact angles on the microparticle deflection in a continuous flow and found three distinct regimes of particle deflection. By systematically removing the MAC out of the microchannel cross-section, we achieved residue-free acoustofluidic microparticle manipulation via SAW-induced ARF inside a half-circular microchannel. The proposed method was applied to efficient fluorescent coating of the microparticles in a size-selective manner without any residue particles left undeflected in the MAC.


Asunto(s)
Acústica , Sonido
16.
Lab Chip ; 22(21): 4007-4042, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-35920614

RESUMEN

Structured microparticles, with unique shapes, customizable sizes, multiple materials, and spatially-defined chemistries, are leading the way for emerging 'lab on a particle' technologies. These microparticles with engineered designs find applications in multiplexed diagnostics, drug delivery, single-cell secretion assays, single-molecule detection assays, high throughput cytometry, micro-robotics, self-assembly, and tissue engineering. In this article we review state-of-the-art particle manufacturing technologies based on flow-assisted photolithography performed inside microfluidic channels. Important physicochemical concepts are discussed to provide a basis for understanding the fabrication technologies. These photolithography technologies are compared based on the structural as well as compositional complexity of the fabricated particles. Particles are categorized, from 1D to 3D particles, based on the number of dimensions that can be independently controlled during the fabrication process. After discussing the advantages of the individual techniques, important applications of the fabricated particles are reviewed. Lastly, a future perspective is provided with potential directions to improve the throughput of particle fabrication, realize new particle shapes, measure particles in an automated manner, and adopt the 'lab on a particle' technologies to other areas of research.


Asunto(s)
Microfluídica , Impresión , Microfluídica/métodos , Nanotecnología , Sistemas de Liberación de Medicamentos , Ingeniería de Tejidos
17.
Lab Chip ; 20(19): 3503-3514, 2020 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-32895694

RESUMEN

Reactions performed in uniform microscale volumes have enabled numerous applications in the analysis of rare entities (e.g. cells and molecules). Here, highly monodisperse aqueous droplets are formed by simply mixing microscale multi-material particles, consisting of concentric hydrophobic outer and hydrophilic inner layers, with oil and water. The particles are manufactured in batch using a 3D printed device to co-flow four concentric streams of polymer precursors which are polymerized with UV light. The cross-sectional shapes of the particles are altered by microfluidic nozzle design in the 3D printed device. Once a particle encapsulates an aqueous volume, each "dropicle" provides uniform compartmentalization and customizable shape-coding for each sample volume to enable multiplexing of uniform reactions in a scalable manner. We implement an enzymatically-amplified immunoassay using the dropicle system, yielding a detection limit of <1 pM with a dynamic range of at least 3 orders of magnitude. Multiplexing using two types of shape-coded particles was demonstrated without cross talk, laying a foundation for democratized single-entity assays.


Asunto(s)
Técnicas Analíticas Microfluídicas , Bioensayo , Estudios Transversales , Inmunoensayo , Microfluídica
18.
Lab Chip ; 20(21): 3922-3929, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-33026382

RESUMEN

The dynamic control of the chemical concentration within droplets is required in numerous droplet microfluidic applications. Here, we propose an acoustofluidic method for the generation of a library of aqueous droplets with the desired chemical concentrations in a continuous oil phase. Surface acoustic waves produced by a focused interdigital transducer interact with two parallel laminar streams with different chemical compositions. Coupling the acoustic waves with the flow streams results in the controlled acoustofluidic mixing of the aqueous solutions through the formation of acoustic streaming flow-induced microvortices. The mixed streams are split at a bifurcation, and one of the streams with a precisely controlled chemical concentration is fed into a T-junction to produce droplets with tunable chemical concentrations. The periodic acoustofluidic mixing of the aqueous streams enables the generation of a droplet library with a well-defined inter-droplet concentration gradient. The proposed method is a promising tool for the on-chip dynamic control of in-droplet chemical concentrations and for next-generation droplet microfluidic applications.

19.
RSC Adv ; 9(14): 7916-7921, 2019 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-35521193

RESUMEN

We present an acoustofluidic method based on travelling surface acoustic waves (TSAWs) to induce self-assembly of microparticles inside a microfluidic channel. The particles are trapped above an interdigitated transducer, placed directly beneath the microchannel, by the TSAW-based direct acoustic radiation force (ARF). This approach was applied to trap 10 µm polystyrene particles, which were pushed towards the ceiling of the microchannel by 72 MHz TSAWs to form single- and multiple-layer colloidal structures. The repair of cracks and defects within the crystal lattice occurs as part of the self-assembly process. The sample flow through the first inlet can be switched with a buffer flow through the second inlet to control the number of particles assembled in the crystalline structure. The constant flow-induced Stokes drag force on the particles is balanced by the opposing TSAW-based ARF. This force balance is essential for the acoustics-based self-assembly of microparticles inside the microchannel. Moreover, we studied the effects of varying input voltage and fluid flow rate on the position and shape of the colloidal structure. The active self-assembly of microparticles into crystals with multiple layers can be used in the bottom-up fabrication of colloidal structures with dimensions greater than 500 µm × 500 µm, which is expected to have important applications in various fields.

20.
Lab Chip ; 18(19): 2936-2945, 2018 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-30140820

RESUMEN

Washing and enrichment of particles and cells are crucial sample preparation procedures in biomedical and biochemical assays. On-chip in-droplet microparticle washing and enrichment have been pursued but remained problematic due to technical difficulties, especially simultaneous and precise control over the droplet interface and in-droplet samples. Here, we have achieved a breakthrough in label-free, continuous, on-demand, in-droplet microparticle washing and enrichment using surface acoustic waves. When exposed to the acoustic field, the droplet and suspended particles experience acoustic radiation force arising from inhomogeneous wave scattering at the liquid/liquid and liquid/solid interfaces. Based on these acoustophoretic phenomena, we have demonstrated in-droplet microparticle washing and enrichment in an acoustofluidic device. We expect that the proposed acoustic method will offer new perspectives to sample washing and enrichment by performing the operation in microscale droplets.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda