Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
J Neuroophthalmol ; 42(1): e274-e280, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34629402

RESUMEN

BACKGROUND: In this study we evaluate the diagnostic accuracy of extraocular muscle volumetry in detecting thyroid eye disease and to compare the results with simple measurements of maximal medial rectus (MR) diameter. METHODS: Cross-sectional study that included 47 eyes of 47 patients with thyroid eye disease and 47 healthy controls. Patients underwent slitlamp examination and imaging consisting of computed tomography scans. Image segmentation and volume measurements were performed by 2 independent researchers. Intraobserver and interobserver reliability testing was also conducted. RESULTS: Total extraocular muscle volume was 7.31 ± 1.88 cm3 and medial volume was 2.38 ± 0.73 cm3 in the study group. In this group, the maximum measured diameter of the MR was 6.67 ± 0.35 mm. MR volume was statistically associated with maximum MR diameter (r = 9.78; P < 0.001). Both MR volume and maximum MR diameter measurements showed good predictive efficacy as shown using receiver operator characteristic curve analysis. CONCLUSIONS: Complications of thyroid eye disease are often sight threatening, and timely diagnosis is crucial for the management of the entity and its sequelae. The results of this study imply that simple measurements of maximum MR diameter are sensitive enough to establish diagnosis.


Asunto(s)
Oftalmopatía de Graves , Estudios Transversales , Oftalmopatía de Graves/diagnóstico por imagen , Humanos , Músculos Oculomotores/diagnóstico por imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
2.
Acta Microbiol Immunol Hung ; 69(4): 351-357, 2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36190829

RESUMEN

Nocardia species are rare causative agents of psoas abscess, more frequently occurring as part of disseminated infection. Only sporadic cases have been reported so far, with Nocardia asteroides and Nocardia farcinica being the most common causative agents. Nocardia elegans is an opportunistic pathogen, accounting for only 0.3-0.6% of infections caused by Nocardia species, usually affecting the respiratory tract.In this study, a previously healthy 74-year-old man was admitted to the University Hospital of Heraklion with fever and intense pain radiating from the lumbar region to the groin and the left thigh, increasing with movement. Imaging findings revealed a large abscess in the left iliopsoas. Blood and pus aspirate cultures yielded a pure culture of Nocardia that was identified by 16S rRNA sequence as N. elegans. The patient was successfully treated with drainage of the abscess along with administration of ceftriaxone, linezolid and trimethoprim-sulfamethoxazole. To our knowledge, this is the first report of iliopsoas abscess caused by N. elegans. Early, accurate diagnosis and timely treatment with drainage of the abscess and long-term administration of antimicrobial agents optimize the outcome.


Asunto(s)
Nocardia , Absceso del Psoas , Humanos , Anciano , Absceso del Psoas/diagnóstico , Absceso del Psoas/tratamiento farmacológico , ARN Ribosómico 16S , Nocardia/genética
3.
Graefes Arch Clin Exp Ophthalmol ; 259(10): 3077-3082, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34155561

RESUMEN

PURPOSE: To investigate the presence of HPV on the ocular surface after surgical excision of HPV infected pterygia and the possible correlation of HPV with pterygium postoperative recurrence. MATERIALS AND METHODS: Both exfoliative pterygium swab samples and respective tissue specimens were received and analyzed with real-time PCR for the detection of HPV-infected pterygia. In addition, swab samples from patients that had HPV-infected pterygia with no recurrence after 1 year of follow-up, as well as swab samples from patients with healthy conjunctiva, were analyzed. RESULTS: Forty eyes with pterygium of 40 patients and 40 eyes with normal conjunctiva were included in the study. HPV virus was detected in the tissue specimens of 11 patients (27.5%) and in the swabs of 9 patients (22.5%). The HPV subtypes detected were 33, 39, 45, 56, 59, 66, and 68. The swab test had sensitivity of 81.82% and 100% specificity. In 15 (43%) patients, a bare sclera technique was used for pterygium removal and eleven of these patients showed recurrence of the disease. Surgical excision with use of autologous conjunctival graft was performed in twenty patients and five of them had recurrence. Patients with recurrent disease were 12.41 times more likely to have an HPV-infected pterygium (p = 0.031). Furthermore, from the 11 HPV positive patients, six had no recurrence, 1 year after surgery. In five of them, a swab sample was taken from the site of the surgical excision 1 year after surgery and real-time PCR was negative for HPV presence. CONCLUSION: Persistence of HPV infection seems to be correlated with postoperative pterygium recurrence. Further investigation with the use of the minimally invasive proposed swab technique may contribute in the understanding of pterygium pathogenesis and in the development of a more efficient treatment planning.


Asunto(s)
Infecciones por Papillomavirus , Pterigion , Conjuntiva , Estudios de Seguimiento , Humanos , Infecciones por Papillomavirus/diagnóstico , Pterigion/diagnóstico , Pterigion/cirugía , Recurrencia , Esclerótica , Trasplante Autólogo , Resultado del Tratamiento
4.
Opt Lett ; 45(20): 5748-5751, 2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-33057275

RESUMEN

We demonstrate the development and application of a prototype hybrid microscopy system integrating autofluorescence (AF) and photoacoustic (PA) label-free contrast modes, for the differentiation of ocular tumors in human surgical biopsies. Hybrid imaging was performed in conjunctival nevi and uveal melanomas tissue sections to acquire quantified data for each molecular background. The AF and PA signals were spatially correlated to establish a novel malignancy indicator that could detect melanomas with high accuracy (t-test; p<0.01). The proposed methodology has the potential to simplify relevant diagnostic procedures and paves the way for the development of novel ophthalmoscopes aiming to the early diagnosis of ocular malignancies in a clinical setting.


Asunto(s)
Neoplasias del Ojo/diagnóstico por imagen , Neoplasias del Ojo/patología , Fluorescencia , Microscopía , Técnicas Fotoacústicas , Biopsia , Detección Precoz del Cáncer , Humanos , Procesamiento de Imagen Asistido por Computador
5.
Eur Radiol ; 29(3): 1365-1374, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30135979

RESUMEN

OBJECTIVES: To evaluate the applicability of stereology and planimetry in orbital volume measurements using computed tomography (CT) and to compare the results between the two measurements. METHODS: Experimental study using sheep craniums for CT imaging. Water filling measurements were performed, as the validation technique. Quantification techniques were also evaluated in five human subjects. To examine the proportion of agreement among measurements, we tested intra- and inter-observer agreement. RESULTS: For stereology customization, a 1/8 systematic sampling scheme was considered as optimal; this resulted in a low coefficient of error (2.59 %) and low measurement time (1.9 mins). In sheep craniums, mean volume measured by water displacement, planimetry and stereology was 17.81 ± 0.59 cm3, 17.87 ± 0.68 cm3 and 17.54 ± 0.49 cm3, respectively. Total volumes, obtained by stereology, were highly correlated with the water-filling method (r=0.893; p = 0.001) and a paired t-test showed significant difference between methods (t=3.047; p = 0.014). Planimetry results displayed a high correlation with the water-filling method (r=0.957; p ≈ 0.001) but no statistically significant difference was found (p = 0.154). Mean difference using planimetry and stereology was 0.332 ± 0.322 cm3. In human subjects, using stereology, the estimated volume ranged between 18.57 cm3 and 19.27 cm3, and the mean orbital volume was 19.05 ± 0.50 cm3 with CE=3.75 ± 0.16 %. Mean measure time was 2.1 ± 0.1 mins. CONCLUSIONS: Stereological measurements were superior to manual planimetry in terms of user effort and time spent. Stereology sampling of 1/8 was successfully applied in human subjects and yielded a strong correlation with manual planimetry. KEY POINTS: • Stereology can be applied to measure the orbital volume using computed tomography. • Stereological measurements display high correlation with gold standard planimetry and combine low coefficient of error (2.59%) with low measurement time (1.9 min). • Stereology is superior in terms of user effort and time spent.


Asunto(s)
Órbita/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales , Curva ROC , Reproducibilidad de los Resultados , Ovinos
6.
Clin Exp Rheumatol ; 35(1): 43-52, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27908307

RESUMEN

OBJECTIVES: To investigate the efficacy and safety of anti-TNF-α agent treatment compared to non-biologic DMARDs in rheumatoid arthritis patients. METHODS: 82 consecutive patients, 29 males, 53 females, aged 42-79, diagnosed with RA and suitable for anti-TNF-α treatment composed two study groups: 42 with pre-existing rheumatoid arthritis-related interstitial lung disease (RA-ILD) and 40 without RA-ILD. Respective control groups consisted of 44 patients with pre-existing RA-ILD and 44 patients without RA-ILD, treated with non-biologic DMARDs. All patients underwent chest high resolution computed tomography (HRCT), pulmonary function tests (PFTs) and peripheral blood biomarkers at baseline and after one year of treatment. RESULTS: There was a significant decrease of air trapping extent and bronchial wall thickening after treatment in RA-ILD and RA-non ILD study groups (p<0.05). This was accompanied by a statistically significant improvement of maximum mid-expiratory flow (MMEF75-25), RV and RV/TLC in both study groups (p<0.05). In the RA-ILD study group ILD extent scores remained unchanged after anti-TNF-α treatment. None of the RA-non ILD group developed new-onset ILD. In both RA-ILD and RA-non ILD control groups, HRCT findings and PFTs did not differ significantly at the one-year follow-up study. Methotrexate (MTX) regression analysis showed in both RA-ILD study and control groups a negative correlation between MTX dose and ILD extent score at one-year and between MTX dose and air trapping extent at baseline and after one year of treatment. CONCLUSIONS: Anti-TNF-α treatment, in contrast to non-biologic DMARDs, there was an improvement of small airways disease. There was no new-onset ILD or exacerbation of preexisting-ILD, especially in patients treated with anti-TNF-α agents, supporting the efficacy and favourable safety profile of this treatment in RA patients.


Asunto(s)
Antirreumáticos/uso terapéutico , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/tratamiento farmacológico , Infliximab/uso terapéutico , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/tratamiento farmacológico , Factor de Necrosis Tumoral alfa/antagonistas & inhibidores , Adulto , Anciano , Artritis Reumatoide/complicaciones , Progresión de la Enfermedad , Quimioterapia Combinada , Femenino , Humanos , Hidroxicloroquina/uso terapéutico , Enfermedades Pulmonares Intersticiales/etiología , Masculino , Metotrexato/uso terapéutico , Persona de Mediana Edad , Pruebas de Función Respiratoria , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
7.
Graefes Arch Clin Exp Ophthalmol ; 255(9): 1795-1799, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28660442

RESUMEN

PURPOSE: The accuracy of contact tonometry may be compromised in cases with disorders affecting central corneal bio-mechanical properties. This study examined the reliability of rebound tonometry (RT) on the area of corneo-scleral limbus, instead of the conventional central corneal area, and the correlation of findings with ocular biometric parameters. METHODS: This is a prospective cross-sectional study performed at the Department of Ophthalmology of the University Hospital of Heraklion, in Crete, Greece. Consecutive cataract surgery candidates without concomitant ocular pathology, apart from cataract, were included. RT was performed on the central cornea (central RT, CRT) as well as on the limbus and scleral spur area (limbal RT, LRT). Findings were correlated with Goldmann applanation tonometry (GAT) as well as axial length (AL), central corneal thickness (CCT), and corneal curvature (CC) measurements. RESULTS: LRT readings were significantly correlated with central CRT as well as with GAT readings, whereas respective correlations with other parameters examined were not statistically significant. CONCLUSIONS: LRT may be used as an alternative tool in clinical practice to determine intraocular pressure when conventional devices and techniques might be inadequate or unreliable.


Asunto(s)
Glaucoma/fisiopatología , Presión Intraocular/fisiología , Tonometría Ocular/instrumentación , Estudios Transversales , Femenino , Glaucoma/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
8.
Acta Medica (Hradec Kralove) ; 58(3): 92-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26686949

RESUMEN

PURPOSE: Taking into account the fact that Goldmann applanation tonometry (GAT) geometrically deforms the corneal apex and displaces volume from the anterior segment whereas Dynamic Contour Tonometry (DCT) does not, we aimed at developing an algorithm for the calculation of ocular rigidity (OR) based on the differences in pressure and volume between deformed and non-deformed status according to the general Friedenwald principle of differential tonometry. METHODS: To avoid deviations of GAT IOP from true IOP in eyes with corneas different from the "calibration cornea" we applied the previously described Orssengo-Pye algorithm to calculate an error coefficient "C/B". To test the feasibility of the proposed model, we calculated the OR coefficient (r) in 17 cataract surgery candidates (9 males and 8 females). RESULTS: The calculated r according to our model (mean ± SD, range) was 0.0174 ± 0.010 (0.0123-0.022) mmHg/µL. A negative statistically significant correlation between axial length and r was detected whereas correlations between r and other biometric parameters examined were statistically not significant. CONCLUSIONS: The proposed method may prove a valid non-invasive tool for the measurement method of OR, which could help in introducing OR in the decision-making of the routine clinical practice.


Asunto(s)
Algoritmos , Catarata/diagnóstico por imagen , Presión Intraocular , Tonometría Ocular/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Ultrasonografía
9.
Acta Medica (Hradec Kralove) ; 57(4): 151-6, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25938898

RESUMEN

PURPOSE: A variety of anti-glaucomatous shunt designs have been proposed so far. This study evaluates the feasibility of a novel shunt design, the intra-scleral parathalamus implant (IPI), in a rabbit eye model. METHODS: Ten healthy albino rabbits were included. Measurements of the IOP, using TonoPenXL, as well as ocular rigidity (OR) and aqueous outflow facility (AO), using a previously described methodology, were performed in both eyes of each animal. Subsequently, the IPI was implanted at the left eye of all animals whereas the right eye served as control. Measurements of IOP were repeated at weekly intervals for 2 months postoperatively whereas measurements of OR and AO were repeated at the 1st and 2nd postoperative week. RESULTS: The IOP decreased significantly whereas the AO increased significantly postoperatively at the operated eyes. A significant postoperative decrease in OR was also recorded at the operated eyes. Respective differences at the fellow eyes were statistically not significant. Two animals developed postoperative complications and were excluded from follow-up. CONCLUSIONS: Results imply that the implantation of the IPI is feasible in rabbit eyes with significant favorable effects on the IOP, AO and OR.


Asunto(s)
Glaucoma/cirugía , Prótesis e Implantes , Esclerostomía/métodos , Animales , Modelos Animales de Enfermedad , Femenino , Presión Intraocular , Conejos
10.
Acta Medica (Hradec Kralove) ; 57(1): 9-14, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25006657

RESUMEN

INTRODUCTION: A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. METHODS: Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. RESULTS: Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. CONCLUSIONS: Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.


Asunto(s)
Cuerpo Ciliar/diagnóstico por imagen , Cuerpo Ciliar/fisiopatología , Diagnóstico por Imagen de Elasticidad , Elasticidad/fisiología , Cristalino/diagnóstico por imagen , Cristalino/fisiopatología , Animales , Atropina/farmacología , Cuerpo Ciliar/efectos de los fármacos , Elasticidad/efectos de los fármacos , Femenino , Cristalino/efectos de los fármacos , Mióticos/farmacología , Midriáticos/farmacología , Pilocarpina/farmacología , Conejos
11.
Int Ophthalmol ; 34(4): 781-6, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24166704

RESUMEN

This study employs optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) imaging as well as optical aberrometry to examine correlations between the anterior chamber angle aperture and visual acuity for near vision as well as coma along the horizontal and vertical axes in eyes implanted with an accommodative intraocular lens (Crystalens). A retrospective comparative consecutive case series of 22 eyes of 11 patients (5 males) uneventfully implanted with a Crystalens. Eyes with signs of posterior capsular opacification were excluded. All eyes were examined with 40 MHz UBM (Ellex Eyecubed) and spectral-domain OCT (Zeiss Visante). The angle aperture along the horizontal and vertical meridians was recorded based on the software of the systems. The coma root mean square (RMS) scores for the horizontal and vertical meridians were also recorded with the iTrace aberrometer. The anterior chamber angle was significantly wider along the horizontal axis compared with the vertical axis by UBM (46.37° and 44.20°, respectively) and by OCT (46.79° and 43.58°, respectively) (p = 0.02 in both cases, paired-samples t test). The correlations between the logMAR-converted Jaeger near vision score and the horizontal or vertical angle apertures was not statistically significant. Horizontal coma RMS was significantly inversely correlated with the horizontal angle aperture (r = -0.45, p = 0.03 and r = -0.39, p = 0.04 by OCT and UBM, respectively). Measurement of the horizontal angle aperture by the modalities used may represent an anatomical and clinical predictor of the optical aberrations induced by the Crystalens.


Asunto(s)
Cámara Anterior/patología , Lentes Intraoculares , Microscopía Acústica/métodos , Presbiopía , Tomografía de Coherencia Óptica , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presbiopía/patología , Presbiopía/fisiopatología , Presbiopía/cirugía , Estudios Retrospectivos , Agudeza Visual
12.
Jpn J Ophthalmol ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39088115

RESUMEN

PURPOSE: This study evaluated the role of shear wave elastography imaging (SWEΙ) in uveal melanomas and the associations between SWEI and clinical and hemodynamic findings. STUDY DESIGN: Prospective, clinical study METHODS: Twelve patients with uveal melanomas, scheduled to undergo Ru-106 brachytherapy, were prospectively recruited from the Department of Ophthalmology of the University Hospital of Heraklion (September-December 2022). B-mode, hemodynamic and SWEI ultrasonography examinations were performed with the HiScan (OPTIKON 2000) and the LOGIQ E9 (GE Healthcare) sonographic systems, respectively. Differences in SWEI scores (kPa) between tumor (TS) and adjacent non-affected choroid (CS), as well as between TS and orbital fat (FS) were examined. Correlations between SWEI and intra-tumoral hemodynamic parameters, including peak systolic and end diastolic velocities and resistivity index (RI) were also examined. RESULTS: TS was significantly correlated with intra-tumoral RI (Pearson's bivariate correlation coefficient 0.681, p=0.015) and with maximal tumor height (Pearson's bivariate correlation coefficient 0.620, p=0.031). TS was significantly higher than both FS and CS scores (paired-samples t-test, p=0.003 and p=0.006, respectively). CONCLUSIONS: SWEI score is applicable as a quantitative biomechanical marker in the assessment of choroidal melanoma. Choroidal melanomas are stiffer than both adjacent choroid and orbital fat. Moreover, choroidal melanomas with higher RI as well as those with higher apical elevations display higher SWEI scores.

13.
Clin Exp Ophthalmol ; 41(1): 73-81, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-22594543

RESUMEN

Ocular rigidity (OR) refers to the relationship between pressure and volume changes in the eyeball. Since the description of the differential tonometry method for the calculation of an OR coefficient by Friedenwald, several other methodologies have been proposed to measure OR, including the anterior chamber manometry, axial length (AL) changes, measurement of pulse amplitude and fundus pulse, ultrasound elastography and evaluation of corneal hysteresis. However, most of these methodologies suffer from deficiencies, such as invasive nature, poor accuracy or reproducibility or technical complexity. Nevertheless, it is possible that OR affects the pathogenesis and clinical course of a variety of ocular conditions, including glaucoma, age-related macular degeneration, presbyopia, corneal changes following refractive surgery as well as the accuracy of IOP measurements by many tonometers. Thus, the future development of non-invasive and easy-to-use methodologies for the accurate measurement of OR in the every-day practice would be clinically important.


Asunto(s)
Longitud Axial del Ojo/fisiopatología , Fenómenos Biomecánicos/fisiología , Elasticidad/fisiología , Glaucoma/fisiopatología , Presión Intraocular/fisiología , Fenómenos Fisiológicos Oculares , Humanos , Tamaño de los Órganos , Tonometría Ocular
14.
Jpn J Radiol ; 41(2): 153-163, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36121625

RESUMEN

PURPOSE: The present study aims to investigate the occurrence and severity of HRCT abnormalities in symptomatic never-smokers, passively exposed to cigarette smoke. MATERIALS AND METHODS: A total of 135 never-smokers with respiratory symptoms, without underlying lung disease, underwent paired inspiratory-expiratory HRCT and completed the secondhand smoking (SHS) exposure scale questionnaire. Individuals passively exposed to tobacco consisted the secondhand smoking group (SHS group) (n = 68); the remaining 67 controls were never exposed to SHS. Statistical analysis was performed using the Kolmogorov-Smirnov, x2 and Pearson Point-Biserial correlation tests. P < 0.05 was statistically significant. RESULTS: HRCT findings in SHS group included bronchial wall thickening (98.5%), mild cylindrical bronchiectasis (44%), ground-glass opacities (17.6%), and mosaic attenuation pattern (53%). Air trapping occurred in 65% of expiratory scans. Differences in occurrence of findings between SHS group participants and controls were statistically significant (p < 0.0001). There was significant correlation between exposure to tobacco smoke in hours/day and in number of cigarettes/day and the presence of mosaic attenuation pattern, ground-glass opacities, cylindrical bronchiectasis and air trapping, respectively (p < 0.05). Cumulative SHS exposure in years was also strongly correlated with the presence of ground-glass opacities, mosaic attenuation pattern, cylindrical bronchiectasis, and air trapping, as well as with the frequency of respiratory symptoms (p < 0.05). CONCLUSION: HRCT findings attributed to SHS are mostly related to airway involvement and are correlated with the duration and grade of exposure to environmental tobacco smoke. SHS followed by lifestyle adjustments should be considered in symptomatic non-smokers with such HRCT findings.


Asunto(s)
Bronquiectasia , Enfermedades Pulmonares , Contaminación por Humo de Tabaco , Humanos , Contaminación por Humo de Tabaco/efectos adversos , Bronquiectasia/diagnóstico por imagen , Encuestas y Cuestionarios
15.
Clin Hemorheol Microcirc ; 83(3): 247-271, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36502308

RESUMEN

Optical Coherence Tomography Angiography (OCTA) is a relatively new imaging technique in ophthalmology for the visualization of the retinal microcirculation and other tissues of the human eye. This review paper aims to describe the basic definitions and principles of OCT and OCTA in the most straightforward possible language without complex mathematical and engineering analysis. This is done to help health professionals of various disciplines improve their understanding of OCTA and design further clinical research more efficiently. First, the basic technical principles of OCT and OCTA and related terminology are described. Then, a list of OCTA advantages and disadvantages, with a special reference to blood flow quantification limitations. Finally, an updated list of the basic hardware and software specifications of some of the commercially available OCTA devices is presented.


Asunto(s)
Retina , Tomografía de Coherencia Óptica , Humanos , Angiografía con Fluoresceína/métodos , Tomografía de Coherencia Óptica/métodos , Vasos Retinianos/diagnóstico por imagen
16.
Hellenic J Cardiol ; 70: 53-64, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36706867

RESUMEN

Cardiovascular disease (CVD) is the most common cause of morbidity/mortality worldwide. Early diagnosis is the key to improve CVD prognosis, and cardiovascular imaging plays a crucial role in this direction. Echocardiography is the most commonly used imaging modality. However, the need for early diagnosis/treatment favors the development of modalities providing information about tissue characterization beyond echocardiography. In this context, the rapid evolution of cardiovascular magnetic resonance (CMR) led to the coexistence of cardiologists and radiologists in the CMR field. Our aim was to provide an overview of indications, sequences, and reporting of CMR findings in various CVDs. The indications/limitations of CMR as well as the pathophysiological significance of various sequences in adult/pediatric CVDs are presented and discussed in detail. The role of CMR indices in the evaluation of the most common clinical scenarios in cardiology and their impact on CVD diagnosis/prognosis were analyzed in detail. Additionally, the comparison of CMR versus other imaging modalities is also discussed. Finally, future research directions are presented. CMR can provide cardiac tissue characterization and biventricular/biatrial functional assessment in the same examination, allowing for early and accurate identification of important subclinical abnormalities, before clinically overt CVD takes place.


Asunto(s)
Enfermedades Cardiovasculares , Adulto , Humanos , Niño , Enfermedades Cardiovasculares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Corazón , Ecocardiografía/métodos , Espectroscopía de Resonancia Magnética
17.
Exp Ther Med ; 25(3): 130, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36845962

RESUMEN

The aim of the present study was to explore the associations between visual outcomes of ocular injury patients in a tertiary hospital unit with clinical and demographic variables and to evaluate the psychosocial impact of the injury on the patients. An 18-month prospective study of 30 eye-injured adult patients was conducted in the General University Hospital of Heraklion, Crete, a tertiary referral hospital. All severe eye injury case information was prospectively collected between February 1, 2020 and August 31, 2021. Best corrected visual acuity (BCVA) was labelled not poor (>0.5/10 or >20/400 on the Snellen scale, <1.3 in LogMAR scale) and poor (≤0.5/10 or ≤20/400 on the Snellen scale, ≥1.3 on the LogMAR equivalent). Data regarding participants' perceived stress levels, by using Perceived Stress Scale 14 (PSS-14), were collected prospectively, one year after study end. Out of 30 ocular injury patients selected, 76.7% were men and most of them were self-employed and private or public sector workers (36.7%). Not poor final BCVA was related to not poor initial BCVA [odds ratio (OR) 1.714; P=0.006]. No statistical associations were found between visual outcome and demographic or clinical factors, but not poor final BCVA was associated with improved self-reported psychological condition of the sufferers, as examined by a questionnaire sheet developed to collect information for study purpose (8.36/10 vs. 6.40/10; P=0.011). No patient reported job loss or changed work status following the injury. Not poor initial BCVA was a significant predictor for not poor final visual outcomes (OR 1.714; P=0.006). Patients with not poor final BCVA expressed higher levels of positive psychology (8.36/10 vs. 6.40/10; P=0.011) and less fear of eye injury repetition (64.0 vs. 100.0%; P=0.286). Not poor final BCVA was associated with low PSS-14 scores one year after study end (77.3 vs. 0.0%, P=0.003). Collaboration between ophthalmologists, mental health professionals and primary care team may be important in order to help patients to cope with the psychosocial burden sequel to eye trauma.

18.
Healthcare (Basel) ; 11(6)2023 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-36981542

RESUMEN

Eye injuries are a major cause of visual disability worldwide and may present a burden to both quality of life of the sufferers and healthcare services. The aim of this study was to extract and triangulate information on the demographic, clinical, and social features of eye-injured adult patients admitted to a tertiary hospital in Greece. The design was a five-year retrospective study of eye-injured adult patients, admitted to the General University Hospital of Heraklion, Crete (GUHH), the single tertiary referral hospital on the island. Drawing the profile of eye-injured patients may add to future health planning. Data collected from 1 January 2015 to 31 December 2019, such as sociodemographic features and clinical information, were extracted. One hundred twenty-eight patients were included. Of those, there was no available information on activity during injury for 6 patients, 78 (60.9%) had work-related ocular injuries, and 44 (34.4%) had non-work-related ocular injuries. Patients with no current formal employment, those who were retired, and formally unemployed and manual force workers had the higher rates of work-related injuries. The most common work-related injuries were closed globe injuries, specifically contusions, while ruptures and penetrating wounds were the most frequent of the open globe injuries. Within the univariate analyses, work-related eye injuries were significantly associated with male gender, middle age, and the place related to daily work activity. Determinants of poor final visual acuity (VA) were the initial VA, the type of injury (p < 0.0001), the distance of the place of residence from the hospital, and the time to hospital admission (p < 0.013). In a multivariate analysis, referred patients and those with open globe injuries arrived at hospital after a two-hour interval compared with those who were not referred and those with closed globe injuries (p ≤ 0.05). A reduction in the time to hospital admission deserves further attention. The interconnection of community and health system services through a capacity increase and networking needs further research in order to obtain targeted and viable access for eye-injured patients.

19.
Artículo en Inglés | MEDLINE | ID: mdl-21415803

RESUMEN

A 44-year-old woman was referred with 3 mm of left enophthalmos and a deep superior sulcus. She was diagnosed 6 months earlier with silent sinus syndrome and had undergone a left middle-meatal antrostomy with improvement of her hypoglobus but not of her enophthalmos and superior sulcus deformity. Two milliliters of Restylane SubQ (Q-Med AB, Uppsala, Sweden) was injected as a single bolus in the intraconal and extraconal posterior orbit via a standard transcutaneous inferotemporal approach using a primed green 21-gauge needle. Immediate reduction of enophthalmos by approximately 2 mm and superior sulcus improvement were noted. This remained stable at 6 months. The symptoms and signs of silent sinus syndrome can be effectively corrected with this minimally invasive nonsurgical option. To our knowledge, the use of hyaluronic acid gel for the treatment of enophthalmos in silent sinus syndrome has not been previously reported.


Asunto(s)
Adyuvantes Inmunológicos/uso terapéutico , Enoftalmia/tratamiento farmacológico , Ácido Hialurónico/análogos & derivados , Enfermedades de los Senos Paranasales/complicaciones , Adulto , Enoftalmia/etiología , Femenino , Geles/administración & dosificación , Humanos , Ácido Hialurónico/uso terapéutico , Inyecciones Intraoculares , Resultado del Tratamiento
20.
Acta Medica (Hradec Kralove) ; 55(2): 100-3, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23101275

RESUMEN

Sometimes intraorbital foreign bodies lead to unexpected findings. A 16-year old boy was referred due to ocular surface trauma. A conjunctival laceration was detected at the level of the left caruncle with associated left exotropia, reduced adduction as well as a preretinal hemorrhage along the nasal periphery of the fundus. A blow-out fracture of the medial orbital wall was suspected and a CT scan of the orbits was scheduled which revealed the presence of a large intraorbital foreign body. The removal of the intraorbital foreign body (which proved to be a bullet) and precautionary laser photocoagulation along the nasal periphery of the left eye were performed. Ocular surface trauma may reveal unexpected findings, such as an intraorbital foreign body, requiring investigation by a CT scan.


Asunto(s)
Cuerpos Extraños en el Ojo/diagnóstico por imagen , Lesiones Oculares Penetrantes/diagnóstico por imagen , Órbita/diagnóstico por imagen , Heridas por Arma de Fuego/diagnóstico por imagen , Adolescente , Humanos , Masculino , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda