1.
ASAIO Trans ; 35(3): 667-70, 1989.
Artículo en Inglés | MEDLINE | ID: mdl-2597560

RESUMEN

Platelet consumption in a hollow-fiber membrane oxygenator (HFMO) and arterial filter (AF) during cardiopulmonary bypass (CPB) was quantified in five pigs using Indium-111 labeled autologous platelets. Platelet labeling was performed 20-24 hours before CPB. After general endotracheal anesthesia, the pigs were systemically heparinized and were placed on CPB via a median sternotomy. After 3 hours of CPB, radioactivity was quantified with a gamma camera and an ionization chamber. The percent of injected dose (mean +/- SD) was 0.79 +/- 0.45 in the HFMO, 2.52 +/- 0.93 in AF, 4.3 +/- 1.2 in blood loss during CPB. Platelet consumption in HFMO during CPB was lower than in bubble oxygenators (19%) or silicone membrane oxygenators (12%) as observed in previous studies.


Asunto(s)
Hemofiltración/instrumentación , Oxigenadores de Membrana , Trombocitopenia/diagnóstico por imagen , Animales , Plaquetas , Diseño de Equipo , Femenino , Radioisótopos de Indio , Compuestos Organometálicos , Recuento de Plaquetas , Cintigrafía , Porcinos , Tropolona/análogos & derivados
2.
ASAIO Trans ; 35(3): 365-8, 1989.
Artículo en Inglés | MEDLINE | ID: mdl-2597481

RESUMEN

The dynamics of platelet deposition on control polyurethane catheters (CPC) and heparin-bonded polyurethane catheters (HBPC) were evaluated with In-111 labeled platelets (In-PLT) using a computerized gamma camera (CGC). Ten nonheparinized dogs (18-25 kg) had both femoral arteries catherized with 10 cm of CPC and HBPC (5 Fr.) 24 hr postinjection of 300-420 microcuries of In-PLT, and imaged for 3 hr with a gamma camera. Regional platelet deposition on three segments of catheters and the puncture site was determined. Catheters were harvested and radioactivity on the catheter segments (proximal: PROX, middle: MID, distal: DIST and puncture site: PS) of both was determined. From the platelet count in blood, and radioactivity in blood and segments of catheters, adjacent artery, and area of artery and catheter, the platelet-density [X10(3) (mean +/- S.D.)] on catheter and artery was calculated and tabulated. Proximal values were cath (CPC), 1289 +/- 1125; artery, 1355 +/- 587; cath (HBPC), 125 +/- 113; artery, 1149 +/- 1620. The middle values were cath (CPC), 1102 +/- 1109; artery, 1512 +/- 625; cath (HBPC), 132 +/- 108; artery, 1011 +/- 942. Distal values were cath (CPC), 780 +/- 584; artery, 132 +/- 108; cath (HBPC), 227 +/- 194; artery, 1457 +/- 1309. The puncture site values were cath (CPC), 106 +/- 382; artery, 1011 +/- 942; cath (HBPC), 164 +/- 135; artery, 1498 +/- 1240. The large standard deviation in retained platelets is due to embolization. The platelet-density and regional counts on catheter segments were lower with HBPC than CPC, as was the rate of platelet-deposition.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Angiografía/instrumentación , Plaquetas/fisiología , Catéteres de Permanencia , Heparina/administración & dosificación , Adhesividad Plaquetaria/fisiología , Poliuretanos , Animales , Perros , Radioisótopos de Indio , Adhesividad Plaquetaria/efectos de los fármacos , Agregación Plaquetaria/fisiología , Cintigrafía , Trombosis/diagnóstico por imagen
3.
Prog Clin Biol Res ; 355: 39-48, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2281114

RESUMEN

The dynamics of platelet deposition on CPC and HBPC was evaluated with In-111 labeled platelets (In-PLT) with a computerized gamma camera (CGC). Ten non-heparinized dogs (18-25 kg) were catheterized in both femoral arteries with 10 cm of CPC and HBPC (5 Fr., Cordis, Inc.) 24 hours post-injection of 300-420 microcuries of In-PLT, and imaged for 3 hours with gamma camera. The regional platelet deposition on three segments of catheters and puncture site was determined. The catheters were harvested and radioactivity on the catheter segments (proximal: PROX, middle: MID, distal: DIST and puncture site: PS) of both was determined. From the platelet count in blood, radioactivity in blood and segments of catheters, adjacent artery and area of artery and catheter, the platelet-density [X10(3)] (mean +/- S.D.) on catheter and artery were calculated and tabulated: (table; see text) The large standard deviation of retained platelets is due to embolization. The platelet-density and regional counts on catheter segments were lower in the HBPC than CPC. The rate of platelet-deposition was lower in the HBPC than CPC. Most of the thrombi were lost during pullout of the catheter. Both in vivo (dynamic) and in vitro studies were necessary for evaluation of CPC thrombogenicity.


Asunto(s)
Plaquetas , Catéteres de Permanencia , Radioisótopos de Indio , Compuestos Organometálicos , Trombosis/diagnóstico por imagen , Tropolona/análogos & derivados , Animales , Cateterismo/efectos adversos , Perros/sangre , Heparina , Cinética , Poliuretanos , Cintigrafía , Trombosis/etiología
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda