Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38912887

RESUMEN

AIMS: Pulsed field ablation (PFA) is an emerging non-thermal ablative modality demonstrating considerable promise for catheter ablation of atrial fibrillation (AF). However, these PFA trials have almost universally included only Caucasian populations, with little data on its effect on other races/ethnicities. The PLEASE-AF trial sought to study the 12-month efficacy and the safety of a multi-electrode hexaspline PFA catheter in treating a predominantly Asian/Chinese population of patients with drug-refractory paroxysmal AF. METHODS AND RESULTS: Patients underwent pulmonary vein (PV) isolation (PVI) by delivering different pulse intensities at the PV ostium (1800 V) and atrium (2000 V). Acute success was defined as no PV potentials and entrance/exit conduction block of all PVs after a 20-min waiting period. Follow-up at 3, 6, and 12 months included 12-lead electrocardiogram and 24-h Holter examinations. The primary efficacy endpoint was 12-month freedom from any atrial arrhythmias lasting at least 30 s. The cohort included 143 patients from 12 hospitals treated by 28 operators: age 60.2 ± 10.0 years, 65.7% male, Asian/Chinese 100%, and left atrial diameter 36.6 ± 4.9 mm. All PVs (565/565, 100%) were successfully isolated. The total procedure, catheter dwell, total PFA application, and total fluoroscopy times were 123.5 ± 38.8 min, 63.0 ± 30.7 min, 169.7 ± 34.6 s, and 27.3 ± 10.1 min, respectively. The primary endpoint was observed in 124 of 143 patients (86.7%). One patient (0.7%) developed a small pericardial effusion 1-month post-procedure, not requiring intervention. CONCLUSION: The novel hexaspline PFA catheter demonstrated universal acute PVI with an excellent safety profile and promising 12-month freedom from recurrent atrial arrhythmias in an Asian/Chinese population with paroxysmal AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05114954.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Anciano , Resultado del Tratamiento , Pueblo Asiatico , China , Catéteres Cardíacos , Recurrencia , Electrocardiografía Ambulatoria , Factores de Tiempo , Diseño de Equipo , Frecuencia Cardíaca , Potenciales de Acción
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda