Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
N Engl J Med ; 388(21): 1966-1980, 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37224198

RESUMEN

BACKGROUND: Upadacitinib, an oral selective Janus kinase (JAK) inhibitor, is under investigation for the treatment of Crohn's disease. METHODS: In two phase 3 induction trials (U-EXCEL and U-EXCEED), we randomly assigned patients with moderate-to-severe Crohn's disease to receive 45 mg of upadacitinib or placebo (2:1 ratio) once daily for 12 weeks. Patients who had a clinical response to upadacitinib induction therapy were randomly assigned in the U-ENDURE maintenance trial to receive 15 mg of upadacitinib, 30 mg of upadacitinib, or placebo (1:1:1 ratio) once daily for 52 weeks. The primary end points for induction (week 12) and maintenance (week 52) were clinical remission (defined as a Crohn's Disease Activity Index score of <150 [range, 0 to 600, with higher scores indicating more severe disease activity]) and endoscopic response (defined as a decrease in the Simple Endoscopic Score for Crohn's Disease [SES-CD; range, 0 to 56, with higher scores indicating more severe disease] of >50% from baseline of the induction trial [or for patients with an SES-CD of 4 at baseline, a decrease of ≥2 points from baseline]). RESULTS: A total of 526 patients underwent randomization in U-EXCEL, 495 in U-EXCEED, and 502 in U-ENDURE. A significantly higher percentage of patients who received 45-mg upadacitinib than those who received placebo had clinical remission (in U-EXCEL, 49.5% vs. 29.1%; in U-EXCEED, 38.9% vs. 21.1%) and an endoscopic response (in U-EXCEL, 45.5% vs. 13.1%; in U-EXCEED, 34.6% vs. 3.5%) (P<0.001 for all comparisons). At week 52 in U-ENDURE, a higher percentage of patients had clinical remission with 15-mg upadacitinib (37.3%) or 30-mg upadacitinib (47.6%) than with placebo (15.1%), and a higher percentage had an endoscopic response with 15-mg upadacitinib (27.6%) or 30-mg upadacitinib (40.1%) than with placebo (7.3%) (P<0.001 for all comparisons). Herpes zoster infections occurred more frequently in the 45-mg and 30-mg upadacitinib groups than in the respective placebo groups, and hepatic disorders and neutropenia were more frequent in the 30-mg upadacitinib group than in the other maintenance groups. Gastrointestinal perforations developed in 4 patients who received 45-mg upadacitinib and in 1 patient each who received 30-mg or 15-mg upadacitinib. CONCLUSIONS: Upadacitinib induction and maintenance treatment was superior to placebo in patients with moderate-to-severe Crohn's disease. (Funded by AbbVie; U-EXCEL, U-EXCEED, and U-ENDURE ClinicalTrials.gov numbers, NCT03345849, NCT03345836, and NCT03345823.).


Asunto(s)
Enfermedad de Crohn , Inhibidores de las Cinasas Janus , Humanos , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/tratamiento farmacológico , Herpes Zóster/inducido químicamente , Herpes Zóster/etiología , Compuestos Heterocíclicos con 3 Anillos/administración & dosificación , Compuestos Heterocíclicos con 3 Anillos/efectos adversos , Compuestos Heterocíclicos con 3 Anillos/uso terapéutico , Inhibidores de las Cinasas Janus/administración & dosificación , Inhibidores de las Cinasas Janus/efectos adversos , Inhibidores de las Cinasas Janus/uso terapéutico , Neutropenia/inducido químicamente , Neutropenia/etiología , Quimioterapia de Inducción/efectos adversos , Quimioterapia de Inducción/métodos , Quimioterapia de Mantención/efectos adversos , Quimioterapia de Mantención/métodos
2.
N Engl J Med ; 389(2): 107-117, 2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37326322

RESUMEN

BACKGROUND: The cardiovascular safety of testosterone-replacement therapy in middle-aged and older men with hypogonadism has not been determined. METHODS: In a multicenter, randomized, double-blind, placebo-controlled, noninferiority trial, we enrolled 5246 men 45 to 80 years of age who had preexisting or a high risk of cardiovascular disease and who reported symptoms of hypogonadism and had two fasting testosterone levels of less than 300 ng per deciliter. Patients were randomly assigned to receive daily transdermal 1.62% testosterone gel (dose adjusted to maintain testosterone levels between 350 and 750 ng per deciliter) or placebo gel. The primary cardiovascular safety end point was the first occurrence of any component of a composite of death from cardiovascular causes, nonfatal myocardial infarction, or nonfatal stroke, assessed in a time-to-event analysis. A secondary cardiovascular end point was the first occurrence of any component of the composite of death from cardiovascular causes, nonfatal myocardial infarction, nonfatal stroke, or coronary revascularization, assessed in a time-to-event analysis. Noninferiority required an upper limit of less than 1.5 for the 95% confidence interval of the hazard ratio among patients receiving at least one dose of testosterone or placebo. RESULTS: The mean (±SD) duration of treatment was 21.7±14.1 months, and the mean follow-up was 33.0±12.1 months. A primary cardiovascular end-point event occurred in 182 patients (7.0%) in the testosterone group and in 190 patients (7.3%) in the placebo group (hazard ratio, 0.96; 95% confidence interval, 0.78 to 1.17; P<0.001 for noninferiority). Similar findings were observed in sensitivity analyses in which data on events were censored at various times after discontinuation of testosterone or placebo. The incidence of secondary end-point events or of each of the events of the composite primary cardiovascular end point appeared to be similar in the two groups. A higher incidence of atrial fibrillation, of acute kidney injury, and of pulmonary embolism was observed in the testosterone group. CONCLUSIONS: In men with hypogonadism and preexisting or a high risk of cardiovascular disease, testosterone-replacement therapy was noninferior to placebo with respect to the incidence of major adverse cardiac events. (Funded by AbbVie and others; TRAVERSE ClinicalTrials.gov number, NCT03518034.).


Asunto(s)
Enfermedades Cardiovasculares , Terapia de Reemplazo de Hormonas , Hipogonadismo , Testosterona , Anciano , Humanos , Masculino , Persona de Mediana Edad , Enfermedades Cardiovasculares/inducido químicamente , Enfermedades Cardiovasculares/epidemiología , Diabetes Mellitus Tipo 2 , Método Doble Ciego , Hipogonadismo/sangre , Hipogonadismo/tratamiento farmacológico , Infarto del Miocardio/epidemiología , Accidente Cerebrovascular/epidemiología , Testosterona/efectos adversos , Testosterona/sangre , Testosterona/uso terapéutico , Terapia de Reemplazo de Hormonas/efectos adversos , Terapia de Reemplazo de Hormonas/métodos , Anciano de 80 o más Años , Geles , Parche Transdérmico
3.
Artículo en Inglés | MEDLINE | ID: mdl-38492904

RESUMEN

BACKGROUND & AIMS: Upadacitinib, an oral Janus kinase inhibitor, achieved significantly higher rates of clinical remission and endoscopic response vs placebo during induction (U-EXCEL [NCT03345849], U-EXCEED [NCT03345836]) and maintenance (U-ENDURE [NCT03345823]) treatment in patients with moderate-to-severe Crohn's disease. Prior biologic failure is often associated with reduced responses to subsequent therapies. This post hoc analysis assessed upadacitinib efficacy by prior biologic failure status. METHODS: Patients were randomized to placebo or upadacitinib 45 mg (UPA45) for 12 weeks (induction). UPA45 clinical responders were enrolled in U-ENDURE and rerandomized to placebo, upadacitinib 15 mg, or upadacitinib 30 mg (UPA30) for 52 weeks. Assessments were by prior biologic failure. RESULTS: Of 1021 patients, 733 (71.8%) had prior biologic failure. Across outcomes and subgroups, upadacitinib-treated patients achieved higher rates vs placebo. During induction, upadacitinib had higher rates vs placebo for clinical remission based on stool frequency/abdominal pain score (without failure: 54.0% vs 28.3%; with failure: 42.2% vs 14.1%) and endoscopic response (without failure: 52.0% vs 16.2%; with failure: 35.7% vs 5.3%). In maintenance, the greatest treatment effect (upadacitinib vs placebo) was among patients with prior biologic failure treated with UPA30 (clinical remission without failure: 58.5% vs 32.7%; with failure: 42.5% vs 8.7%; endoscopic response without failure: 43.9% vs 17.9%; with failure: 38.9% vs 4.0%). Patients without vs with prior biologic failure had fewer adverse events. CONCLUSIONS: Upadacitinib led to higher absolutes rates of clinical and endoscopic outcomes in patients without vs with prior biologic failure. Patients treated with upadacitinib achieved greater rates of clinical and endoscopic improvements vs placebo, regardless of prior biologic exposure. CLINICALTRIALS: gov: NCT03345849, NCT03345836, NCT03345823.

4.
Am Heart J ; 245: 41-50, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34871580

RESUMEN

BACKGROUND: Testosterone exerts some effects on the cardiovascular system that could be considered beneficial; some other effects may potentially increase the risk of cardiovascular (CV) events. Neither the long-term efficacy nor safety of testosterone treatment has been studied in an adequately-powered randomized trial. METHODS: The Testosterone Replacement therapy for Assessment of long-term Vascular Events and efficacy ResponSE in hypogonadal men (TRAVERSE) study is a randomized, double-blind, placebo-controlled, parallel group, non-inferiority, multicenter study. Eligible participants are men, 45 to 80 years, with serum testosterone concentration <300 ng/dL and hypogonadal symptoms, who have evidence pre-existing CV disease or increased risk of CV disease. Approximately 6,000 subjects will be randomized to either 1.62% transdermal testosterone gel or a matching placebo gel daily for an anticipated duration of up to 5 years. The primary outcome is CV safety defined by the major adverse CV event composite of nonfatal myocardial infarction, nonfatal stroke, or death due to CV causes. The trial will continue until at least 256 adjudicated major adverse CV event endpoints have occurred to assess whether the 95% (2-sided) upper confidence limit for a hazard ratio of 1.5 can be ruled out. Secondary endpoints include prostate safety defined as the incidence of adjudicated high grade prostate cancer and efficacy in domains of sexual function, bone fractures, depression, anemia, and diabetes. RESULTS: As of July 1, 2021, 5,076 subjects had been randomized. CONCLUSIONS: The TRAVERSE study will determine the CV safety and long-term efficacy of testosterone treatment in middle-aged and older men with hypogonadism with or at increased risk of CV disease.


Asunto(s)
Enfermedades Cardiovasculares , Sistema Cardiovascular , Hipogonadismo , Anciano , Enfermedades Cardiovasculares/etiología , Método Doble Ciego , Humanos , Hipogonadismo/inducido químicamente , Hipogonadismo/complicaciones , Hipogonadismo/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Testosterona/uso terapéutico , Resultado del Tratamiento
5.
Am J Gastroenterol ; 112(10): 1584-1592, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28071654

RESUMEN

OBJECTIVES: The Crohn's Disease Endoscopic Index of Severity (CDEIS) and the Simple Endoscopic Score for Crohn's Disease (SES-CD) are commonly used to assess Crohn's disease (CD) activity; however neither instrument is fully validated. We evaluated the responsiveness to change of the SES-CD and CDEIS using data from a trial of adalimumab, a drug therapy of known efficacy. METHODS: Paired video recordings (N=112) of colonoscopies (baseline and week 8-12) obtained from patients with CD who participated in a trial of adalimumab therapy were reviewed in random order, in duplicate, by four central readers (56 pairs of videos by 2 groups of readers). Responsiveness of the SES-CD and the CDEIS was evaluated by comparing correlations between the observed and pre-specified predictions of change scores for these endoscopic indices with a global endoscopic evaluation of severity (GELS), a patient reported outcome (PRO2), and the Crohn's disease activity index (CDAI), and by calculation of the standardized effect size, and Guyatt's Responsiveness statistic (GRS) using 2 definitions of change; (1) treatment assignment and (2) an absolute change in total PRO2 of 50. The potential application of effect size estimates was demonstrated by calculating hypothetical sample sizes for comparing two independent groups. The impact of removing stenosis as an index item and adjusting for the number of segments observed was also assessed. RESULTS: Changes in both endoscopic instruments and the GELS were highly correlated. The SES-CD displayed numerically higher effect sizes for both definitions of change. The standardized effect size and GRS estimates (95% confidence interval) for the SES-CD based on treatment assignment were 0.84 (0.53, 1.15) and 0.79 (0.48, 1.09). Corresponding values for the CDEIS were 0.72 (0.42, 1.02) and 0.75 (0.45, 1.06). The standardized effect size and GRS estimates for the SES-CD based on an absolute change in total PRO2 of 50 points or greater were 0.76 (0.49, 1.02) and 0.93 (0.64, 1.21). Corresponding values for CDEIS were 0.70 (0.44, 0.97), 0.83 (0.55, 1.10). Removal of stenosis as an index item and adjusting for observed segments did not improve responsiveness estimates. CONCLUSIONS: Although both the SES-CD and CDEIS are valid measures of endoscopic disease activity that are moderately responsive to changes in endoscopic disease activity, the SES-CD displayed numerically greater responsiveness in this data set.


Asunto(s)
Adalimumab/administración & dosificación , Enfermedad de Crohn , Monitoreo de Drogas , Endoscopía Gastrointestinal , Proyectos de Investigación/normas , Adulto , Antiinflamatorios/administración & dosificación , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/tratamiento farmacológico , Monitoreo de Drogas/métodos , Monitoreo de Drogas/estadística & datos numéricos , Endoscopía Gastrointestinal/métodos , Endoscopía Gastrointestinal/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Tamaño de la Muestra , Índice de Severidad de la Enfermedad , Estadística como Asunto , Grabación en Video/métodos
6.
Gut ; 65(7): 1119-25, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-25935574

RESUMEN

OBJECTIVE: The Crohn's Disease Endoscopic Index of Severity (CDEIS) and Simple Endoscopic Score for Crohn's Disease (SES-CD) are commonly used to assess Crohn's disease (CD) activity; however, neither instrument has been fully validated. We assessed intra-rater and inter-rater reliability of these indices. DESIGN: Video recordings of colonoscopies obtained from 50 patients with CD who participated in an induction trial of a biological therapy were triplicated and reviewed in random order by four central readers. Data were used to assess intra-rater and inter-rater reliability for CDEIS, SES-CD and a global evaluation of lesion severity (GELS). Subsequently, readers participated in a consensus process that identified common sources of disagreement. RESULTS: Intraclass correlation coefficients (ICCs) for intra-rater reliability for CDEIS, SES-CD and GELS (95% CIs) were 0.89 (0.86 to 0.93), 0.91 (0.89 to 0.95) and 0.81 (0.77 to 0.89), respectively, with standard error of measurement (SEM) of 2.10, 2.42 and 1.15. The corresponding ICCs for inter-rater reliability were 0.71 (0.63 to 0.76), 0.83 (0.75 to 0.88) and 0.62 (0.52 to 0.70), with SEM of 3.42, 3.07 and 1.63, respectively. Correlation between CDEIS and GELS was 0.75, between SES-CD and GELS was 0.74 and between CDEIS and SES-CD was 0.92. The most common sources of disagreement were interpretation of superficial ulceration, definition of disease site at the ileocolonic anastomosis, assessment of anorectal lesions and grading severity of stenosis. CONCLUSIONS: Central reading of CDEIS and SES-CD had 'substantial' to 'almost perfect' intra-rater and inter-rater reliability; however, the responsiveness of these instruments is yet to be determined. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov NCT01466374.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Endoscopía Gastrointestinal , Índice de Severidad de la Enfermedad , Adulto , Consenso , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/etiología , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Úlcera/diagnóstico por imagen , Úlcera/etiología , Grabación en Video , Adulto Joven
8.
Surg Endosc ; 25(3): 930-4, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20927551

RESUMEN

BACKGROUND: Fundamental techniques and essential tools for performing "no scar" surgery still need to be developed. Our study was designed to evaluate the feasibility of performing small bowel resection by transcolonic NOTES(®) and transabdominal approach using rigid laparoscopic and flexible endoscopic instruments. METHODS: One non survival and four survival experiments were performed using a porcine model. The endoscope with an overtube was advanced into the peritoneal cavity through the colotomy. Mini-laparoscopic instruments were placed through the abdominal wall under the endoscopic observation. The endoscope was replaced with a rigid linear stapler. The small bowel was identified. The segment of the small bowel was resected by firing the endo stapler, and extracted through the colon. The two limbs of the small bowel were approximated with two stay-sutures. An enterotomy was then created on the antimesenteric sides of each line. A side-to-side anastomosis was performed with another application of the endo stapler. The stapler was withdrawn. The enterotomy was closed by suturing. The colotomy was closed with endoclips and the endoscope was withdrawn. The mini-laparoscopic instruments were removed. RESULTS: Small bowel resection was successfully performed in all animals. The surgery time was 70 minutes. There was no mortality or complications. The animals recovered uneventfully, and survived the 2 weeks postprocedure period. They remained healthy, and gained weight. Necropsy was performed 2 weeks after the surgery. On necropsy, evaluation of the abdominal skin revealed no scars. The peritoneal cavity was examined. No signs of infection, bleeding, perforations, and adhesions were noted. Endoscopic examination of the colotomy and anastomosis revealed complete healing that was confirmed by histopathology. CONCLUSIONS: The study has demonstrated the feasibility of small bowel resection using transcolonic NOTES(®) and transabdominal approach. Simultaneous use of flexible endoscopic and rigid laparoscopic instruments in NOTES(®) is not only feasible but has significant advantages and greatly facilitates the performance of the operation, yet leaves no scars.


Asunto(s)
Abdomen/cirugía , Cicatriz/prevención & control , Intestino Delgado/cirugía , Cirugía Endoscópica por Orificios Naturales/métodos , Complicaciones Posoperatorias/prevención & control , Anastomosis Quirúrgica , Animales , Colon , Endoscopios , Estudios de Factibilidad , Laparoscopios , Cirugía Endoscópica por Orificios Naturales/instrumentación , Docilidad , Sus scrofa , Porcinos
9.
Surg Innov ; 18(2): 106-13, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21245067

RESUMEN

OBJECTIVES: Although adhesions can be removed by adhesiolysis using laparotomy or laparoscopy, they typically recur sometimes with equal severity. It is suggested that minimizing the invasiveness of the operative technique by using natural orifice translumenal endoscopic surgery (NOTES) may reduce adhesion re-formation. The aim of the study was to evaluate the feasibility and safety of adhesiolysis by using a novel transgastric NOTES approach and collect pilot data on adhesion recurrence after transgastric NOTES adhesiolysis. METHODS: One nonsurvival and 5 survival female pigs were used in this experimental survival study. Interventions included (a) induction of adhesions by laparotomy, (b) 2 weeks survival, (c) transgastric NOTES adhesiolysis with endoscopic evaluation and scoring of adhesions before and immediately after adhesiolysis, (d) 2 weeks survival, and (e) necropsy with endoscopic and necroscopic evaluation and scoring of recurrent adhesions. Main outcome measures were (a) survival and complication rates and (b) assessment of adhesion formation and re-formation using the Hopkins Adhesion Formation Score. RESULTS: No mortality and no complications were observed. A total of 11 adhesions formed before the adhesiolysis in 5 survival study animals. All were successfully divided. The frequency of adhesions and median adhesion formation score decreased significantly immediately after adhesiolysis compared with that prior to the procedure (frequency, 11 vs 0, P = .011; the median score = 2.0 [range 1-3] vs 0.0 [range 0-0], P = .004). The treatment gains maintained at 2 weeks after the adhesiolysis. LIMITATIONS: The limitations of this study were the low number of study animals and short-term follow-up data. CONCLUSIONS: Adhesiolysis using NOTES transgastric approach is feasible, safe, and effective with minimal adhesion re-formation.


Asunto(s)
Cirugía Endoscópica por Orificios Naturales/mortalidad , Cirugía Endoscópica por Orificios Naturales/métodos , Cavidad Peritoneal/cirugía , Adherencias Tisulares/cirugía , Animales , Modelos Animales de Enfermedad , Estudios de Factibilidad , Femenino , Inmunohistoquímica , Laparoscopía/métodos , Laparoscopía/mortalidad , Laparotomía/efectos adversos , Laparotomía/métodos , Cavidad Peritoneal/patología , Proyectos Piloto , Distribución Aleatoria , Medición de Riesgo , Administración de la Seguridad , Tasa de Supervivencia , Porcinos , Adherencias Tisulares/patología , Resultado del Tratamiento
10.
Dig Dis Sci ; 55(9): 2463-70, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20704034

RESUMEN

INTRODUCTION: Lasers 2-microm in wavelength offer efficient tissue cutting with limited thermal damage in biological tissue. OBJECTIVE: To evaluate the dissection capabilities of a 2-microm continuous-wave laser for NOTES procedures. METHODS AND PROCEDURES: We conducted 18 acute animal experiments. Group 1 (three animals): transcolonic access to the peritoneal cavity (15-W transcolonic laser puncture, balloon dilation over the laser probe). Group 2 (six animals): transcolonic access with needle-knife puncture and balloon dilation. Group 3 (three animals): transgastric access to the peritoneal cavity (similar technique as group 1) followed by laser-assisted dissection of the kidney. In one animal of group 3, a therapeutic target (hematoma) was created by percutaneous puncture of the kidney. Group 4 (six animals): transgastric access (similar to the technique of group 2). RESULTS: Translumenal access to the peritoneal cavity was achieved in 2-3 min in group 1 (significantly shorter than with the needle-knife-assisted technique, 4-5 min, p=0.02) and in 7-10 min in group 3 (compared to 6-17 min in group 4, p=0.88). In group 3, laser dissection of the parietal peritoneum and of perinephric connective tissue allowed access to the retroperitoneum with complete removal of a blood collection in the animal with puncture trauma. Laser dissection demonstrated good maneuverability, clean and rapid cutting, and excellent hemostasis. Peritoneoscopy and necropsy showed no damage of targeted tissue and surrounding organs. CONCLUSIONS: The 2-microm continuous-wave laser system showed promising capabilities for highly precise and safe dissection during NOTES procedures.


Asunto(s)
Disección/instrumentación , Laparoscopios , Laparoscopía , Rayos Láser , Cavidad Peritoneal/cirugía , Tulio , Animales , Cateterismo , Colon/cirugía , Modelos Animales de Enfermedad , Disección/efectos adversos , Diseño de Equipo , Femenino , Hematoma/cirugía , Técnicas Hemostáticas/instrumentación , Riñón/cirugía , Laparoscopía/efectos adversos , Neumoperitoneo Artificial , Estómago/cirugía , Sus scrofa
11.
Gastrointest Endosc ; 68(4): 760-6, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18926184

RESUMEN

BACKGROUND: Transgastric and transvaginal approaches in natural orifice transluminal endoscopic surgery (NOTES) are the most commonly used, although the transcolonic approach may have some advantages. OBJECTIVE: To develop a workable technique for transcolonic NOTES. DESIGN: A nonsurvival study followed by a survival study in a porcine model. Transcolonic peritoneoscopy was performed with the use of a novel intracolonic occlusion balloon. The colotomy was closed with endoclips. A necropsy and histologic evaluation were performed 2 weeks after surgery. SETTING: Academic hospital, health science research center. SUBJECTS: Fifteen female Yorkshire pigs (5 nonsurvival, 10 survival). INTERVENTIONS: A balloon-tipped catheter was placed proximal to the colotomy site. The balloon was inflated to occlude the colonic lumen. An endoscope was inserted through the anus. Colonic incision was created with an endoscopic needle-knife at 15 to 20 cm from the anal verge. Peritoneoscopy was performed. The colotomy was closed with endoclips. MAIN OUTCOME MEASUREMENTS: Rates of complications, survival, healing, and adhesions. RESULTS: Two initial experiments were complicated by bowel distension and contamination of the incision area by colonic content. In the remaining 13 pigs, the experiments were performed with the use of the intracolonic occlusion balloon. No complications were documented. Necropsies were performed 2 weeks after surgery. Gross and histologic evaluations demonstrated near complete healing. Minimal adhesions were identified in 4 of 10 pigs. LIMITATION: Imperfection of the prototype balloon. CONCLUSIONS: Excessive bowel distension and fecal contamination because of spillage from the proximal bowel may be barriers to performing transcolonic NOTES. Isolation of the operative area by splitting the bowel and sealing the colonic lumen with the balloon above the colonic incision may overcome these problems and optimize the technique.


Asunto(s)
Cateterismo/métodos , Laparoscopía/métodos , Anestesia/métodos , Animales , Cateterismo/instrumentación , Colon/patología , Colonoscopía/métodos , Femenino , Laparoscopios , Cuidados Preoperatorios , Porcinos
12.
Nat Clin Pract Gastroenterol Hepatol ; 3(4): 229-33; quiz following 233, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16582965

RESUMEN

BACKGROUND: A 65-year-old white Mediterranean male with a 10-year history of intermittent anemia, who was otherwise completely asymptomatic, was referred to our hospital in March 2004. He had a medical history of beta thalassemia and fecal occult blood tests had occasionally been positive. INVESTIGATIONS: Fecal occult blood test, laboratory investigations, esophagogastroduodenoscopy, colonoscopy with retrograde ileoscopy, mesenteric angiography, small-bowel series, CT scan of the abdomen and pelvis, Meckel's scan, and capsule endoscopy. Laparoscopic surgery followed by macroscopic and microscopic histopathologic examination of samples obtained during the procedure. DIAGNOSIS: Crohn's disease of the small bowel. MANAGEMENT: Laparoscopic segmental small-bowel resection with end-to-end anastomosis. Postsurgical treatment with Pentasa 4 g a day.


Asunto(s)
Anemia Ferropénica/etiología , Enfermedad de Crohn/diagnóstico , Anciano , Antiinflamatorios no Esteroideos/uso terapéutico , Colonoscopía , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/patología , Enfermedad de Crohn/cirugía , Diagnóstico Diferencial , Endoscopía del Sistema Digestivo , Humanos , Mucosa Intestinal/patología , Intestino Delgado/patología , Masculino , Mesalamina/uso terapéutico , Sangre Oculta , Talasemia beta/epidemiología
13.
Eur J Gastroenterol Hepatol ; 18(5): 565-6, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16607158

RESUMEN

Anti-TNFalpha drugs are currently used in the treatment of patients with Crohn's disease. Studies have reported neurological side effects occurring after anti-TNFalpha treatment, including infliximab-induced complications.


Asunto(s)
Anticuerpos Monoclonales/efectos adversos , Enfermedad de Crohn/tratamiento farmacológico , Enfermedades Desmielinizantes/inducido químicamente , Fármacos Gastrointestinales/efectos adversos , Humanos , Infliximab , Masculino , Persona de Mediana Edad , Factor de Necrosis Tumoral alfa/antagonistas & inhibidores
14.
J Crohns Colitis ; 10(9): 1006-14, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27385400

RESUMEN

BACKGROUND AND AIMS: The Crohn's Disease Endoscopic Index of Severity [CDEIS] and Simplified Endoscopic Score for Crohn's Disease [SES-CD] demonstrate consistent overall intra- and inter-rater reliability. However, the reliability of some index items is relatively poor. We evaluated scoring conventions to improve the reliability of these items. METHODS: Five gastroenterologists with no previous experience scoring the CDEIS or SES-CD were trained on their use. A total of 65 video recordings of colonoscopies were scored blindly by each gastroenterologist before and after additional training on index scoring conventions. Intra-class correlation coefficients [ICCs] assessed the effect of application of these conventions on the reliability of the CDEIS, SES-CD, and a Global Evaluation of Lesion Severity [GELS] score. RESULTS: Following training on scoring conventions, inter-rater ICCs (95% confidence interval [CI]) for the total SES-CD score increased from 0.78 [0.71, 0.85] to 0.85 [0.79, 0.89]. The ICCs for the total CDEIS and GELS scores were not affected: corresponding inter-rater ICCs were 0.74 [0.65, 0.81] and 0.49, [0.38, 0.61] before and 0.73 [0.65, 0.81] and 0.53 [0.42, 0.64] following application of scoring conventions. Estimations of ulcer depth, surface area, anatomical location, and stenosis were important sources of variability. CONCLUSIONS: Use of scoring conventions previously developed by expert central readers enhanced the reliability of the SES-CD but did not similarly affect the CDEIS or GELS. As the SES-CD is more likely to be reliable than the CDEIS and can be optimised with targeted training, it is the preferred instrument for use in clinical trials.


Asunto(s)
Toma de Decisiones Clínicas/métodos , Colonoscopía , Enfermedad de Crohn/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de Crohn/patología , Educación Médica Continua , Femenino , Gastroenterología/educación , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Ontario , Reproducibilidad de los Resultados , Método Simple Ciego , Grabación en Video , Adulto Joven
15.
Can J Gastroenterol ; 18(9): 559-65, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15457295

RESUMEN

BACKGROUND: Wireless capsule endoscopy (CE) is increasingly being used in the investigation of obscure gastrointestinal (GI) bleeding, but some studies have found that many of the bleeding lesions recognized by this technique are within the reach of conventional endoscopy. METHODS: The results of CE performed in the authors' centre in a 12 month period for obscure GI bleeding were retrospectively reviewed. RESULTS: Of the 46 patients with obscure GI bleeding, CE found a definite or probable cause in 19 (41%) and a possible cause in another 10 (22%), with an overall diagnostic yield of 63%. One of these lesions was found to be within reach of conventional gastroscopy, two were within reach of push enteroscopy, four were within reach of colonoscopy and one was within reach of retrograde enteroscopy through a stoma. The percentage of patients with a bleeding source within reach of routine endoscopy but missed during pre-CE endoscopy was significantly higher for those patients having endoscopy only in the community (30% [eight of 27]) versus in the authors' centre (0% [zero of 19]). CONCLUSIONS: CE was valuable for diagnosing bleeding lesions not only within the small bowel, but also in the stomach and colon. However, "second-look" endoscopy may be considered before ordering CE for obscure GI bleeding when local expertise is available.


Asunto(s)
Hemorragia Gastrointestinal/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Angiodisplasia/diagnóstico , Enfermedades del Ciego/diagnóstico , Endoscopía Gastrointestinal , Femenino , Hemorragia Gastrointestinal/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
Inflamm Bowel Dis ; 20(10): 1850-61, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25029615

RESUMEN

BACKGROUND: Crohn's disease (CD) is a chronic idiopathic inflammatory disorder of the gastrointestinal tract. Recently, mucosal healing has been proposed as a goal of therapy because clinical symptoms are subjective. Evaluative indices that measure endoscopic disease activity are required to define mucosal healing for clinical trials. The primary objective of this systematic review was to assess the existing evaluative indices that measure disease activity in CD and evaluate their role as outcome measures in clinical trials. METHODS: A systematic literature review was performed using MEDLINE (Ovid), EMBASE (Ovid), PubMed, the Cochrane Library (CENTRAL), and DDW abstracts to identify randomized controlled trials and controlled clinical trials that used a relevant evaluative index from inception to February 2013. The data obtained from these trials were reviewed and summarized. RESULTS: The initial literature searches identified 2300 citations. After duplicates were removed, 1454 studies remained. After application of the apriori inclusion and exclusion criteria, 109 articles were included and 3 were identified with handsearches. In total, 9 evaluative indices for CD were identified and reviewed. The Crohn's Disease Endoscopic Index of Severity (CDEIS) and the Simple Endoscopic Score in Crohn's Disease (SES-CD) are indices with the most extensively described operating properties. CONCLUSIONS: Both the endoscopic evaluative instrument selected and the definition chosen for mucosal healing affect the validity of assessing endoscopic disease activity during a clinical trial for CD. Currently, the CDEIS and SES-CD have the most data regarding operating properties; however, further validation is required.


Asunto(s)
Enfermedad de Crohn/patología , Enfermedad de Crohn/terapia , Endoscopía/métodos , Membrana Mucosa/fisiopatología , Proyectos de Investigación , Índice de Severidad de la Enfermedad , Cicatrización de Heridas , Investigación Biomédica , Ensayos Clínicos como Asunto , Guías como Asunto , Humanos
17.
Inflamm Bowel Dis ; 20(8): 1465-71, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24831558

RESUMEN

BACKGROUND: Assessment of endoscopic disease activity, as measured by various endoscopic evaluative instruments, is an essential part of quantifying disease activity in clinical trials in patients with ulcerative colitis (UC). Evaluative instruments have specific definitions and operating properties that influence the interpretation of clinical trial results. Our objective was to systematically review all endoscopic evaluative instruments that measure endoscopic disease activity in UC and to describe their definitions and operating characteristics (reliability, responsiveness, and predictive validity). METHODS: We performed a systematic review of evaluative instruments assessing endoscopic disease activity in UC. MEDLINE (Ovid), EMBASE (Ovid), PubMed, the Cochrane Library (CENTRAL), and Digestive Disease Week abstracts of clinical trials were searched from inception to January 2013. RESULTS: In total, 5885 studies were identified and screened for inclusion criteria. Four hundred twenty-two studies involving 31 evaluative instruments were identified. Two types of indices were found, numerical scoring systems and stepwise grading scales. CONCLUSIONS: Both the endoscopic evaluative instrument selected and the definition chosen for mucosal healing affect the validity of assessing endoscopic disease activity during a clinical trial for UC. Currently, the sigmoidoscopic component of the Mayo Score and the ulcerative colitis endoscopic index of severity show the most promise as reliable evaluative instruments of endoscopic disease activity. However, further validation is required.


Asunto(s)
Investigación Biomédica , Colitis Ulcerosa/patología , Colitis Ulcerosa/terapia , Endoscopía/métodos , Guías de Práctica Clínica como Asunto , Índice de Severidad de la Enfermedad , Cicatrización de Heridas , Ensayos Clínicos como Asunto , Humanos , Pronóstico
18.
Inflamm Bowel Dis ; 20(11): 2092-103, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25137418

RESUMEN

BACKGROUND: Crohn's disease (CD) is an idiopathic, chronic, transmural inflammatory disorder of the gastrointestinal tract. Because mucosal involvement is near-universal, endoscopic healing has emerged as an important aspect in improving outcome. However, resolution of histologic disease activity has potential to convey additional benefit beyond that attained with endoscopic healing alone. Validated scoring systems of histologic disease activity are required to further assess this possibility. The aim of this study was to systematically review the existing histologic disease activity indices (HDAI) for CD and to assess their operating properties and potential use as outcome measures in clinical trials. METHODS: MEDLINE (Ovid), EMBASE (Ovid), PubMed, the Cochrane Library (CENTRAL), and Digestive Disease Week (DDW) abstracts were searched from 1981 to April 2013 for applicable studies to identify relevant studies for review and analysis. RESULTS: In total, 3732 citations were screened to obtain 89 articles for inclusion. Sixty-six HDAIs were characterized as either stepwise or numerical instruments. These HDAIs were used for either assessment of response to medical therapy or for comparison with biomarkers or imaging tests. None of the HDAIs identified was developed according to currently accepted methods for developing evaluative instruments, and none have been formally validated. CONCLUSIONS: Measurement of histologic disease activity has potential value in CD; however, no validated measures are available. Additional research is needed to develop a methodologically rigorous instrument for use in clinical investigation and potentially for clinical practice.


Asunto(s)
Enfermedad de Crohn/patología , Enfermedad de Crohn/terapia , Inmunohistoquímica/métodos , Índice de Severidad de la Enfermedad , Animales , Humanos , Pronóstico
20.
Gastrointest Endosc ; 62(4): 538-44, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16185968

RESUMEN

BACKGROUND: Little is known about the accuracy of capsule endoscopy (CE) in evaluation of small-bowel Crohn's disease. METHODS: Symptomatic eligible patients had ileocolonoscopy and biopsies from the terminal ileum, followed by small-bowel radiologic studies before CE. Endoscopic, radiologic, CE, and histologic findings were compared. Histology (terminal ileum biopsy specimens or a tissue sample after small-bowel resection) served as a criterion standard. RESULTS: Fifty-four patients were enrolled; 15 of the 54 patients were excluded from data analysis (critical small-bowel strictures, 14, identified on radiology; incomplete CE, 1). Data were analyzed for 39 patients. All patients had histologic evaluation of the small bowel. Final diagnosis of active small-intestine Crohn's disease was made in 29/39 patients (74.4%). When calculated, CE yielded a sensitivity and a specificity of 89.6% and 100.0%, respectively, and a positive predictive value and a negative predictive value of 100.0% and 76.9%, respectively, whereas small-bowel series were 27.6%/100.0% and 100.0%/32.3%. CONCLUSIONS: CE is more accurate in detecting small-bowel inflammatory changes suggestive of Crohn's disease than conventional studies. CE, combined with ileocolonoscopy, may be proposed as a first-line investigation of the small intestine in cases of uncomplicated known or suspected Crohn's disease.


Asunto(s)
Enfermedad de Crohn/diagnóstico , Endoscopía Gastrointestinal/métodos , Ileítis/diagnóstico , Íleon/diagnóstico por imagen , Telemetría , Adulto , Biopsia , Diagnóstico Diferencial , Enema , Femenino , Estudios de Seguimiento , Humanos , Íleon/patología , Masculino , Metilcelulosa , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiografía , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda