Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Injury ; 49(10): 1810-1815, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30017179

RESUMEN

PURPOSE: The purpose of this prospective cohort study of patients treated with volar plating for distal radius fractures is to evaluate the efficacy (defined as detection rate, or the ability to detect dorsally protruding screws) of additional dorsal tangential views (DTV) after obtaining standard anteroposterior (AP) and elevated lateral views by evaluating the change in intraoperative strategy in 100 patients. MATERIALS AND METHODS: 100 patients aged 18 years and older undergoing volar plating for acute extra- or intra- articular distal radius fractures were prospectively enrolled. Intraoperative fluoroscopy views, including AP, elevated lateral and DTV were obtained. Intraoperative -screw- revision frequency for dorsal screw protrusion, screw position relative to volar plate and to dorsal compartment, and screw lengths were evaluated. RESULTS: Additional DTV led to a change of intraoperative management in 31 of 100 (31%) of patients. A total of 35 out of 504 screws (6.9%) were changed. Screws in the two most radial screws in the plate were at the highest risk of being revised; 16 (46%) screws in most radial position and nine (26%) screws in the 2nd from radial position were revised. Furthermore, five (14%) screws in both the 2nd from ulnar and most ulnar screw holes were revised after DTV. No screws were revised in the central hole. The median length of revised protruding screws was 22 mm (range, 12-26 mm), and these were changed to a mean length of 20  mm (range, 10-22 mm). CONCLUSION: In this prospective series of 100 patients, obtaining additional DTV is found to be efficacious as it led to change in intraoperative strategy in one-third of patients. We concur with previous pilot studies that DTV, after obtaining conventional AP and elevated lateral views, is advised to avoid dorsally protruding screws, which could minimise the potential for iatrogenic extensor tendon rupture after volar plating for distal radius fractures. Diagnostic accuracy of DTV is subject of a subsequent prospective cohort study with post-operative CT to serve as the reference standard. LEVEL OF EVIDENCE: .Prognostic I.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas , Fracturas del Radio/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Tornillos Óseos/efectos adversos , Femenino , Fluoroscopía , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/fisiopatología , Estándares de Referencia , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
2.
Injury ; 49(4): 871-876, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29503014

RESUMEN

BACKGROUND: Intramedullary-nails (IMN) are the treatment of choice for most tibial shaft fractures due to their minimally-invasive nature and non-demanding surgical technique. However, a potential iatrogenic pitfall is intra-articular interlocking screw positioning within the proximal (PTFJ) and distal (DTFJ) tibiofibular joints that may go unrecognized. OBJECTIVE: To evaluate the incidence of intra-articular screw penetration of the PTFJ and DTFJs after interlocking of IMN for tibial fractures. INTERVENTION: Reamed IMN using modern techniques, including proximal interlocking via standard aiming jig and distal interlocking either freehand or using SureShot®. METHODS: Prospective series of 165 consecutive patients with a tibial shaft fracture managed with an IMN. Diagnosis and incidence of penetration of the PTFJ and DTFJ was assessed on protocolled low-dose postoperative CT-scans (standardized clinical practice for assessing rotational alignment). The degree of penetration of the TFJ's was graded as: Grade 1-slight breach of the tibial cortex; Grade 2-clear penetration of the tibial cortex with intra-articular screw tip; and Grade 3-penetration of both tibial- and fibular cortices with screw tip in fibula. RESULTS: Of the 165 tibial shaft fractures, using the AO/OTA classification, 69% were simple, 16% wedge and 15% complex fractures. Following IMN 42% of patients had intra-articular screw penetration of their PTFJ whilst 39% had penetration of their DTFJ. 66% of patients had penetration of either one- or both of their TFJs. The grading of PTFJ violation was distributed as follows: Grade 1 in 24 patients; Grade 2 in 26 patients and Grade 3 in 19 patients. DTFJ violation was graded as: Grade 1 in 21 patients; 40 patients had Grade 2 violation; and four patients had a Grade 3 penetration. CONCLUSIONS: This diagnostic imaging study reports a high rate of intra-articular screw penetration of the PTFJ and DTFJ after interlocking of IMN for tibia shaft fractures. A prospective cohort study is underway to evaluate its clinical significance. Changes to enable alteration in forced angle of interlocking screw trajectory and avoidance of the anteromedial to posterolateral locking screw may reduce the incidence of TJF violation. LEVEL OF EVIDENCE: Level II - Diagnostic Imaging Study.


Asunto(s)
Artralgia/diagnóstico por imagen , Tornillos Óseos/efectos adversos , Fijación Intramedular de Fracturas/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artralgia/etiología , Femenino , Curación de Fractura , Humanos , Enfermedad Iatrogénica , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Fracturas de la Tibia/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda