Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Heart J ; 45(29): 2647-2656, 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-38751064

RESUMEN

BACKGROUND AND AIMS: Risk scores are proposed for genetic arrhythmias. Having proposed in 2010 one such score (M-FACT) for the long QT syndrome (LQTS), this study aims to test whether adherence to its suggestions would be appropriate. METHODS: LQT1/2/3 and genotype-negative patients without aborted cardiac arrest (ACA) before diagnosis or cardiac events (CEs) below age 1 were included in the study, focusing on an M-FACT score ≥2 (intermediate/high risk), either at presentation (static) or during follow-up (dynamic), previously associated with 40% risk of implantable cardioverter defibrillator (ICD) shocks within 4 years. RESULTS: Overall, 946 patients (26 ± 19 years at diagnosis, 51% female) were included. Beta-blocker (ßB) therapy in 94% of them reduced the rate of those with a QTc ≥500 ms from 18% to 12% (P < .001). During 7 ± 6 years of follow-up, none died; 4% had CEs, including 0.4% with ACA. A static M-FACT ≥2 was present in 110 patients, of whom 106 received ßBs. In 49/106 patients with persistent dynamic M-FACT ≥2, further therapeutic optimization (left cardiac sympathetic denervation in 55%, mexiletine in 31%, and ICD at 27%) resulted in just 7 (14%) patients with CEs (no ACA), with no CEs in the remaining 57. Additionally, 32 patients developed a dynamic M-FACT ≥2 but, after therapeutic optimization, only 3 (9%) had CEs. According to an M-FACT score ≥2, a total of 142 patients should have received an ICD, but only 22/142 (15%) were implanted, with shocks reported in 3. CONCLUSIONS: Beta-blockers often shorten QTc, thus changing risk scores and ICD indications for primary prevention. Yearly risk reassessment with therapy optimization leads to fewer ICD implants (3%) without increasing life-threatening events.


Asunto(s)
Antagonistas Adrenérgicos beta , Desfibriladores Implantables , Síndrome de QT Prolongado , Humanos , Femenino , Masculino , Adulto , Síndrome de QT Prolongado/terapia , Antagonistas Adrenérgicos beta/uso terapéutico , Medición de Riesgo , Adulto Joven , Adolescente , Niño , Persona de Mediana Edad , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Antiarrítmicos/uso terapéutico , Preescolar , Electrocardiografía , Factores de Riesgo
2.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38289867

RESUMEN

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Asunto(s)
Taquicardia Ventricular , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Ganglio Estrellado , Volumen Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Fibrilación Ventricular/etiología , Función Ventricular Izquierda , Persona de Mediana Edad
3.
Eur J Clin Invest ; 54(8): e14209, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38597271

RESUMEN

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Terapia Antiplaquetaria Doble , Hemorragia , Inhibidores de Agregación Plaquetaria , Humanos , Apéndice Atrial/cirugía , Inhibidores de Agregación Plaquetaria/uso terapéutico , Terapia Antiplaquetaria Doble/métodos , Hemorragia/inducido químicamente , Anciano , Trombosis/prevención & control , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular/prevención & control , Estudios Observacionales como Asunto , Cierre del Apéndice Auricular Izquierdo
4.
Eur J Clin Invest ; : e14292, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058274

RESUMEN

BACKGROUND: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) are new anti-hyperglycaemic drugs with proven cardiovascular (CV) benefit in diabetic and non-diabetic patients at high CV risk. Despite a neutral class effect on arrhythmia risk, data on semaglutide suggest a possible drug-specific benefit in reducing atrial fibrillation (AF) occurrence. OBJECTIVE: To perform a meta-analysis of randomized clinical trials (RCTs) to assess the risk of incident AF in patients treated with semaglutide compared to placebo. METHODS AND RESULTS: Ten RCTs were included in the analysis. Study population encompassed 12,651 patients (7285 in semaglutide and 5366 in placebo arms), with median follow-up of 68 months. A random effect meta-analytic model was adopted to pool relative risk (RR) of incident AF. Semaglutide reduces the risk of AF by 42% (RR .58, 95% CI .40-.85), with low heterogeneity across the studies (I2 0%). At subgroup analysis, no differences emerged between oral and subcutaneous administration (oral: RR .53, 95% CI .23-1.24, I2 0%; subcutaneous: RR .59, 95% CI .39-.91, I2 0%; p-value .83). In addition, meta-regression analyses did not show any potential influence of baseline study covariates, in particular the proportion of diabetic patients (p-value .14) and body mass index (BMI) (p-value .60). CONCLUSIONS: Semaglutide significantly reduces the occurrence of incident AF by 42% as compared to placebo in individuals at high CV risk, mainly affected by type 2 diabetes mellitus. This effect appears to be consistent independently of the route of administration of the drug (oral or subcutaneous), the presence of underlying diabetes and BMI.

5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38531027

RESUMEN

AIMS: Percutaneous stellate ganglion block (PSGB) through single-bolus injection and thoracic epidural anaesthesia (TEA) have been proposed for the acute management of refractory ventricular arrhythmias (VAs). However, data on continuous PSGB (C-PSGB) are scant. The aim of this study is to report our dual-centre experience with C-PSGB and to perform a systematic review on C-PSGB and TEA. METHODS AND RESULTS: Consecutive patients receiving C-PSGB at two centres were enrolled. The systematic literature review follows the latest Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. Our case series (26 patients, 88% male, 60 ± 16 years, all with advanced structural heart disease, left ventricular ejection fraction 23 ± 11%, 32 C-PSGBs performed, with a median duration of 3 days) shows that C-PSGB is feasible and safe and leads to complete VAs suppression in 59% and to overall clinical benefit in 94% of cases. Overall, 61 patients received 68 C-PSGBs and 22 TEA, with complete VA suppression in 63% of C-PSGBs (61% of patients). Most TEA procedures (55%) were performed on intubated patients, as opposed to 28% of C-PSGBs (P = 0.02); 63% of cases were on full anticoagulation at C-PSGB, none at TEA (P < 0.001). Ropivacaine and lidocaine were the most used drugs for C-PSGB, and the available data support a starting dose of 12 and 100 mg/h, respectively. No major complications occurred, yet TEA discontinuation rate due to side effects was higher than C-PSGB (18 vs. 1%, P = 0.01). CONCLUSION: Continuous PSGB seems feasible, safe, and effective for the acute management of refractory VAs. The antiarrhythmic effect may be accomplished with less concerns for concomitant anticoagulation compared with TEA and with a lower side-effect related discontinuation rate.


Asunto(s)
Anestesia Epidural , Bloqueo Nervioso Autónomo , Ganglio Estrellado , Humanos , Ganglio Estrellado/efectos de los fármacos , Ganglio Estrellado/fisiopatología , Anestesia Epidural/métodos , Bloqueo Nervioso Autónomo/métodos , Masculino , Persona de Mediana Edad , Femenino , Anciano , Resultado del Tratamiento , Anestésicos Locales/administración & dosificación , Lidocaína/administración & dosificación
6.
Front Cardiovasc Med ; 11: 1327179, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38426118

RESUMEN

Background: Artificial intelligence (AI) has shown promise in the early detection of various cardiac conditions from a standard 12-lead electrocardiogram (ECG). However, the ability of AI to identify abnormalities from single-lead recordings across a range of pathological conditions remains to be systematically investigated. This study aims to assess the performance of a convolutional neural network (CNN) using a single-lead (D1) rather than a standard 12-lead setup for accurate identification of ECG abnormalities. Methods: We designed and trained a lightweight CNN to identify 20 different cardiac abnormalities on ECGs, using data from the PTB-XL dataset. With a relatively simple architecture, the network was designed to accommodate different combinations of leads as input (<100,000 learnable parameters). We compared various lead setups such as the standard 12-lead, D1 alone, and D1 paired with an additional lead. Results: This has been corrected to "The CNN based on single-lead ECG (D1) achieved satisfactory performance compared to the standard 12-lead framework (average percentage AUC difference: −8.7%). Notably, for certain diagnostic classes, there was no difference in the diagnostic AUC between the single-lead and the standard 12-lead setups. When a second lead was detected in the CNN in addition to D1, the AUC gap was further reduced to an average percentage difference of -2.8% compared with that of the standard 12-lead setup. Conclusions: A relatively lightweight CNN can predict different classes of cardiac abnormalities from D1 alone and the standard 12-lead ECG. Considering the growing availability of wearable devices capable of recording a D1-like single-lead ECG, we discuss how our findings contribute to the foundation of a large-scale screening of cardiac abnormalities.

7.
Biology (Basel) ; 13(2)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38392323

RESUMEN

The cardiac autonomic nervous system (CANS) plays a pivotal role in cardiac homeostasis as well as in cardiac pathology. The first level of cardiac autonomic control, the intrinsic cardiac nervous system (ICNS), is located within the epicardial fat pads and is physically organized in ganglionated plexi (GPs). The ICNS system does not only contain parasympathetic cardiac efferent neurons, as long believed, but also afferent neurons and local circuit neurons. Thanks to its high degree of connectivity, combined with neuronal plasticity and memory capacity, the ICNS allows for a beat-to-beat control of all cardiac functions and responses as well as integration with extracardiac and higher centers for longer-term cardiovascular reflexes. The present review provides a detailed overview of the current knowledge of the bidirectional connection between the ICNS and the most studied cardiac pathologies/conditions (myocardial infarction, heart failure, arrhythmias and heart transplant) and the potential therapeutic implications. Indeed, GP modulation with efferent activity inhibition, differently achieved, has been studied for atrial fibrillation and functional bradyarrhythmias, while GP modulation with efferent activity stimulation has been evaluated for myocardial infarction, heart failure and ventricular arrhythmias. Electrical therapy has the unique potential to allow for both kinds of ICNS modulation while preserving the anatomical integrity of the system.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda