Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Exp Biol ; 227(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38725420

RESUMEN

A fatigue-failure process is hypothesized to govern the development of tibial stress fractures, where bone damage is highly dependent on the peak strain magnitude. To date, much of the work examining tibial strain during running has ignored uphill and downhill running despite the prevalence of this terrain. This study examined the sensitivity of tibial strain to changes in running grade and speed using a combined musculoskeletal-finite element modelling routine. Seventeen participants ran on a treadmill at ±10, ±5 and 0 deg; at each grade, participants ran at 3.33 m s-1 and at a grade-adjusted speed of 2.50 and 4.17 m s-1 for uphill and downhill grades, respectively. Force and motion data were recorded in each grade and speed combination. Muscle and joint contact forces were estimated using inverse-dynamics-based static optimization. These forces were applied to a participant-adjusted finite element model of the tibia. None of the strain variables (50th and 95th percentile strain and strained volume ≥4000 µÎµ) differed as a function of running grade; however, all strain variables were sensitive to running speed (F1≥9.59, P≤0.03). In particular, a 1 m s-1 increase in speed resulted in a 9% (∼260 µÎµ) and 155% (∼600 mm3) increase in peak strain and strained volume, respectively. Overall, these findings suggest that faster running speeds, but not changes in running grade, may be more deleterious to the tibia.


Asunto(s)
Carrera , Tibia , Carrera/fisiología , Humanos , Masculino , Tibia/fisiología , Fenómenos Biomecánicos , Adulto , Femenino , Adulto Joven , Análisis de Elementos Finitos , Estrés Mecánico
2.
J Clin Densitom ; 27(1): 101462, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38104525

RESUMEN

INTRODUCTION: High resolution peripheral quantitative computed tomography (HR-pQCT) imaging protocol requires defining where to position the ∼1 cm thick scan along the bone length. Discrepancies between the use of two positioning methods, the relative and fixed offset, may be problematic in the comparison between studies and participants. This study investigated how bone landmarks scale linearly with length and how this scaling affects both positioning methods aimed at providing a consistent anatomical location for scan acquisition. METHODS: Using CT images of the radius (N = 25) and tibia (N = 42), 10 anatomical landmarks were selected along the bone length. The location of these landmarks was converted to a percent length along the bone, and the variation in their location was evaluated across the dataset. The absolute location of the HR-pQCT scan position using both offset methods was identified for all bones and converted to a percent length position relative to the HR-pQCT reference line for comparison. A secondary analysis of the location of the scan region specifically within the metaphysis was explored at the tibia. RESULTS: The location of landmarks deviated from a linear relationship across the dataset, with a range of 3.6 % at the radius sites, and 4.5 % at the tibia sites. The consequent variation of the position of the scan at the radius was 0.6 % and 0.3 %, and at the tibia 2.4 % and 0.5 %, for the fixed and relative offset, respectively. The position of the metaphyseal junction with the epiphysis relative to the scan position was poorly correlated to bone length, with R2 = 0.06 and 0.37, for the fixed and relative offset respectively. CONCLUSION: The variation of the scan position by either method is negated by the intrinsic variation of the bone anatomy with respect both to total bone length as well as the metaphyseal region. Therefore, there is no clear benefit of either offset method. However, the lack of difference due to the inherent variation in the underlying anatomy implies that it is reasonable to compare studies even if they are using different positioning methods.


Asunto(s)
Radio (Anatomía) , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Radio (Anatomía)/diagnóstico por imagen , Tibia/diagnóstico por imagen , Extremidad Superior , Epífisis , Densidad Ósea
3.
J Biomech Eng ; 146(9)2024 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-38558117

RESUMEN

State-of-the-art participant-specific finite element models require advanced medical imaging to quantify bone geometry and density distribution; access to and cost of imaging is prohibitive to the use of this approach. Statistical appearance models may enable estimation of participants' geometry and density in the absence of medical imaging. The purpose of this study was to: (1) quantify errors associated with predicting tibia-fibula geometry and density distribution from skin-mounted landmarks using a statistical appearance model and (2) quantify how those errors propagate to finite element-calculated bone strain. Participant-informed models of the tibia and fibula were generated for thirty participants from height and sex and from twelve skin-mounted landmarks using a statistical appearance model. Participant-specific running loads, calculated using gait data and a musculoskeletal model, were applied to participant-informed and CT-based models to predict bone strain using the finite element method. Participant-informed meshes illustrated median geometry and density distribution errors of 4.39-5.17 mm and 0.116-0.142 g/cm3, respectively, resulting in large errors in strain distribution (median RMSE = 476-492 µÎµ), peak strain (limits of agreement =±27-34%), and strained volume (limits of agreement =±104-202%). These findings indicate that neither skin-mounted landmark nor height and sex-based predictions could adequately approximate CT-derived participant-specific geometry, density distribution, or finite element-predicted bone strain and therefore should not be used for analyses comparing between groups or individuals.


Asunto(s)
Peroné , Tibia , Humanos , Tibia/diagnóstico por imagen , Peroné/diagnóstico por imagen , Análisis de Elementos Finitos , Marcha , Modelos Estadísticos , Densidad Ósea
4.
Sensors (Basel) ; 24(8)2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38676058

RESUMEN

In racehorses, the risk of musculoskeletal injury is linked to a decrease in speed and stride length (SL) over consecutive races prior to injury. Surface characteristics influence stride parameters. We hypothesized that large changes in stride parameters are found during galloping in response to dirt racetrack preparation. Harrowing of the back stretch of a half-mile dirt racetrack was altered in three individual lanes with decreasing depth from the inside to the outside. Track underlay compaction and water content were changed between days. Twelve horses (six on day 2) were sequentially galloped at a target speed of 16 ms-1 across the three lanes. Speed, stride frequency (SF), and SL were quantified with a GPS/GNSS logger. Mixed linear models with speed as covariate analyzed SF and SL, with track hardness and moisture content as fixed factors (p < 0.05). At the average speed of 16.48 ms-1, hardness (both p < 0.001) and moisture content (both p < 0.001) had significant effects on SF and SL. The largest difference in SL of 0.186 m between hardness and moisture conditions exceeded the 0.10 m longitudinal decrease over consecutive race starts previously identified as injury predictor. This suggests that detailed measurements of track conditions might be useful for refining injury prediction models.


Asunto(s)
Marcha , Animales , Caballos/fisiología , Fenómenos Biomecánicos/fisiología , Marcha/fisiología , Carrera/fisiología
5.
Sensors (Basel) ; 24(10)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38793873

RESUMEN

The intensity gradient is a new cutpoint-free metric that was developed to quantify physical activity (PA) measured using accelerometers. This metric was developed for use with the ENMO (Euclidean norm minus one) metric, derived from raw acceleration data, and has not been validated for use with count-based accelerometer data. In this study, we determined whether the intensity gradient could be reproduced using count-based accelerometer data. Twenty participants (aged 7-22 years) wore a GT1M, an ActiGraph (count-based), and a GT9X, ActiGraph (raw accelerations) accelerometer during both in-lab and at-home protocols. We found strong agreement between GT1M and GT9X counts during the combined in-lab activities (mean bias = 2 counts) and between minutes per day with different intensities of activity (e.g., sedentary, light, moderate, and vigorous) classified using cutpoints (mean bias < 5 min/d at all intensities). We generated bin sizes that could be used to generate IGs from the count data (mean bias = -0.15; 95% LOA [-0.65, 0.34]) compared with the original IG. Therefore, the intensity gradient could be used to analyze count data. The count-based intensity gradient metric will be valuable for re-analyzing historical datasets collected using older accelerometer models, such as the GT1M.


Asunto(s)
Acelerometría , Ejercicio Físico , Humanos , Niño , Acelerometría/métodos , Adolescente , Femenino , Masculino , Ejercicio Físico/fisiología , Adulto Joven
6.
J Biomech ; 167: 112074, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38614021

RESUMEN

Suppression of noise from recorded signals is a critically important data processing step for biomechanical analyses. While a wide variety of filtering or smoothing spline methods are available, the majority of these are not well suited for the analysis of signals with rapidly changing derivatives such as the processing of motion data for impact-like events. This is because commonly used low-pass filtering approaches or smoothing splines typically assume a single fixed cut-off frequency or regularization penalty which fails to describe rapid changes in the underlying function. To overcome these limitations we examine a class of adaptive penalized splines (APS) that extend commonly used penalized spline smoothers by inferring temporal adaptations in regularization penalty from observed data. Three variations of APS are examined in which temporal variation of spline penalization is described via either a series of independent random variables, an autoregressive process or a smooth cubic spline. Comparing the performance of APS on simulated datasets is promising with APS reducing RMSE by 48%-183% compared to a widely used Butterworth filtering approach. When inferring acceleration from noisy measurements describing the position of a pendulum impacting a barrier we observe between a 13% (independent variables) to 28% (spline) reduction in RMSE when compared to a 4th order Butterworth filter with optimally selected cut-off frequency. In addition to considerable improvement in RMSE, APS can provide estimates of uncertainty for fitted curves and generated quantities such as peak accelerations or durations of stationary periods. As a result, we suggest that researchers should consider the use of APS if features such as impact peaks, rates of loading, or periods of negligible acceleration are of interest.


Asunto(s)
Aceleración , Fenómenos Biomecánicos
7.
JBMR Plus ; 8(7): ziae077, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38911320

RESUMEN

Bone loss below the level of neurological lesion is a well-known complication of spinal cord injury (SCI). To date, most research has focused on pharmaceutical intervention using antiresorptives to prevent bone loss during the acute phase of SCI; however, limited research has investigated treatments for established osteoporosis during chronic SCI. Romosozumab, a monoclonal antibody with both antiresorptive and anabolic effects, has demonstrated significant increases in BMD for women with established PMO. Therefore, the purpose of this study was to examine the efficacy of monthly treatment with romosozumab to improve DXA-derived areal BMD at the hip, and CT-derived BMC and strength at the hip and knee in women with chronic SCI and an inability to ambulate. Twelve female participants with chronic SCI were recruited to receive 1 yr of monthly subcutaneous injections of romosozumab (210 mg). DXA and CT scans were taken at baseline, and months 3, 6, and 12 to quantify bone mineral, and finite element (FE) analysis was used to predict bone strength. Longitudinal mixed effects models were employed to determine the impact of treatment on bone properties. After 12 mo of treatment, areal BMD at the lumbar spine and total hip were significantly increased with median changes of 10.2% (IQR: 8.3-15.2%, p<.001) and 4.2% (IQR: 3.4-7.7%, p = .009), respectively. Improvements at the hip were primarily due to increases in trabecular, not cortical, bone and effects were sufficient to significantly increase FE-predicted strength by 20.3% (IQR: 9.5-37.0%, p = .004). Treatment with romosozumab did not lead to any significant improvement in bone mineral at the distal femur or proximal tibia. These findings provide promising results for romosozumab treatment to improve bone mineral and reduce fracture risk at the hip, but not the knee, in women with chronic SCI.

8.
Bone ; 182: 117054, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38395248

RESUMEN

Fractures of the equine metacarpophalangeal (MCP) joint are among the most common and fatal injuries experienced by racehorses. These bone injuries are a direct result of repetitive, high intensity loading of the skeleton during racing and training and there is consensus that they represent a mechanical fatigue phenomenon. Existing work has found the fatigue life of bone to be strongly determined by bone microarchitecture and the resulting stressed volume (i.e., the volume of bone stressed above assumed yield). The purpose of this study was to quantify the influence of bone microarchitecture on the mechanical fatigue behaviour of equine subchondral bone from the MCP joint across a wide variety of sample types. Forty-eight subchondral bone samples were prepared from the third metacarpal (MC3) and proximal phalanx (P1) of 8 horses and subsequently imaged using high resolution micro-computed tomography (µCT) to quantify microarchitectural features of interest, including bone volume fraction, tissue mineral density, pore size, pore spacing, and pore number. Samples were cyclically loaded in compression to a stress of 70 MPa, and fatigue life was defined as the number of cycles until failure. Finite element models were created from the µCT images and used to quantify stressed volume. Based on the expected log point-wise predictive density, stressed volume was a strong predictor of fatigue life in both the MC3 and P1. A regional analysis indicated fatigue life was more strongly associated with bone volume fraction in the superficial (r2 = 0.32, p < 0.001) and middle (r2 = 0.70, p < 0.001) regions of the subchondral bone, indicating the prominent role that the cortical plate played in the fatigue resistance of equine subchondral bone. By improving our understanding of the variance in fatigue life measurements, this research helps clarify the underlying mechanisms of the mechanical fatigue process and provides a basic understanding of subchondral bone injuries in the equine fetlock joint.


Asunto(s)
Fracturas Óseas , Huesos del Metacarpo , Caballos , Animales , Huesos del Metacarpo/diagnóstico por imagen , Microtomografía por Rayos X , Extremidad Superior , Ensayo de Materiales
9.
Sci Rep ; 14(1): 2748, 2024 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-38302524

RESUMEN

Simulation studies, such as finite element (FE) modeling, provide insight into knee joint mechanics without patient involvement. Generic FE models mimic the biomechanical behavior of the tissue, but overlook variations in geometry, loading, and material properties of a population. Conversely, subject-specific models include these factors, resulting in enhanced predictive precision, but are laborious and time intensive. The present study aimed to enhance subject-specific knee joint FE modeling by incorporating a semi-automated segmentation algorithm using a 3D Swin UNETR for an initial segmentation of the femur and tibia, followed by a statistical shape model (SSM) adjustment to improve surface roughness and continuity. For comparison, a manual FE model was developed through manual segmentation (i.e., the de-facto standard approach). Both FE models were subjected to gait loading and the predicted mechanical response was compared. The semi-automated segmentation achieved a Dice similarity coefficient (DSC) of over 98% for both the femur and tibia. Hausdorff distance (mm) between the semi-automated and manual segmentation was 1.4 mm. The mechanical results (max principal stress and strain, fluid pressure, fibril strain, and contact area) showed no significant differences between the manual and semi-automated FE models, indicating the effectiveness of the proposed semi-automated segmentation in creating accurate knee joint FE models. We have made our semi-automated models publicly accessible to support and facilitate biomechanical modeling and medical image segmentation efforts ( https://data.mendeley.com/datasets/k5hdc9cz7w/1 ).


Asunto(s)
Cartílago Articular , Humanos , Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Rodilla , Tibia/diagnóstico por imagen , Fémur/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
10.
J Orthop Res ; 42(6): 1231-1243, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38111181

RESUMEN

Osteoporosis is a chronic disease characterized by reduced bone mass and increased fracture risk, estimated to affect over 10 million people in the United States alone. Drugs used to treat bone loss often come with significant limitations and/or long-term safety concerns. Proteoglycan-4 (PRG4, also known as lubricin) is a mucin-like glycoprotein best known for its boundary lubricating function of articular cartilage. In more recent years, it has been shown that PRG4 has anti-inflammatory properties, contributes to the maintenance of subchondral bone integrity, and patients with PRG4 mutations are osteopenic. However, it remains unknown how PRG4 impacts mechanical and material properties of bone. Therefore, our objective was to perform a phenotyping study of bone in a Prg4 gene trap (GT) mouse (PRG4 deficient). We found that femurs of Prg4 GT mice have altered mechanical, structural, and material properties relative to wildtype littermates. Additionally, Prg4 GT mice have a greater number of calvarial osteoclasts than wildtype mice, but do not have a notable inflammatory serum profile. Finally, Prg4 GT mice do not have an altered rate of bone formation, and exogenous recombinant human PRG4 (rhPRG4) administration inhibited osteoclastogenesis in vitro, suggesting that the skeletal phenotype may be due to changes in bone resorption. Overall, this work demonstrates that PRG4 deficiency affects several integral properties of bone structure, mechanics, and skeletal cell activity, and provides the foundation and insight toward future work evaluating PRG4 as a potential therapeutic target in treating bone loss.


Asunto(s)
Osteoclastos , Osteogénesis , Proteoglicanos , Animales , Osteogénesis/efectos de los fármacos , Osteoclastos/efectos de los fármacos , Ratones , Humanos , Masculino , Ratones Endogámicos C57BL , Cráneo , Femenino , Proteínas Recombinantes/farmacología , Proteínas Recombinantes/uso terapéutico , Fémur/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda