Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Regul Toxicol Pharmacol ; 149: 105591, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38467236

RESUMEN

Post-market medical device-associated failures and patient problems are reported in Medical Device Reports (MDRs) to the US Food and Drug Administration. Reports are accessible through Manufacturer and User Facility Device Experience (MAUDE), a database including both required and voluntary submissions. We present an overview of >10 million MDRs received from 2011 to 2021. Approximately 92% of reporting issues represent medical device physical or functional failures, categorized from 1704 codes related to medical device integrity or function. ∼8% were coded adverse events (AEs). Patient outcomes are reported via 998 patient codes in 19 medical specialties (cardiovascular, orthopedic, etc.). ∼40% of patient reports indicated "no health consequences"; however, a small number of devices had consistently high AE reports. While overall reports did not exhibit a sex-based dichotomy, ∼9% of the reported AEs occurred more frequently in females, many of which were related to immune effects. The analyses are subject to uncertainties and potential bias based on data available and data selected for analysis. However, such an overview of post-market MDR data, not previously published, fills a gap in understanding medical device issues and patient-based outcomes related to medical device use. Trends identified may be subjects of additional hypotheses, analysis, and research.


Asunto(s)
Equipos y Suministros , Vigilancia de Productos Comercializados , United States Food and Drug Administration , Humanos , Femenino , Estados Unidos , Equipos y Suministros/efectos adversos , Masculino , Bases de Datos Factuales , Factores Sexuales , Falla de Equipo
2.
Regul Toxicol Pharmacol ; 141: 105410, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37210026

RESUMEN

Propranolol is a widely used ß-blocker that can generate a nitrosated derivative, N-nitroso propranolol (NNP). NNP has been reported to be negative in the bacterial reverse mutation test (the Ames test) but genotoxic in other in vitro assays. In the current study, we systematically examined the in vitro mutagenicity and genotoxicity of NNP using several modifications of the Ames test known to affect the mutagenicity of nitrosamines, as well as a battery of genotoxicity tests using human cells. We found that NNP induced concentration-dependent mutations in the Ames test, both in two tester strains that detect base pair substitutions, TA1535 and TA100, as well as in the TA98 frameshift-detector strain. Although positive results were seen with rat liver S9, the hamster liver S9 fraction was more effective in bio-transforming NNP into a reactive mutagen. NNP also induced micronuclei and gene mutations in human lymphoblastoid TK6 cells in the presence of hamster liver S9. Using a panel of TK6 cell lines that each expresses a different human cytochrome P450 (CYP), CYP2C19 was identified as the most active enzyme in the bioactivation of NNP to a genotoxicant among those tested. NNP also induced concentration-dependent DNA strand breakage in metabolically competent 2-dimensional (2D) and 3D cultures of human HepaRG cells. This study indicates that NNP is genotoxic in a variety of bacterial and mammalian systems. Thus, NNP is a mutagenic and genotoxic nitrosamine and a potential human carcinogen.


Asunto(s)
Mutágenos , Propranolol , Ratas , Animales , Cricetinae , Humanos , Mutágenos/toxicidad , Propranolol/toxicidad , Mutación , Daño del ADN , Mutagénesis , Pruebas de Mutagenicidad/métodos , Mamíferos
3.
Regul Toxicol Pharmacol ; 74: 178-86, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26387931

RESUMEN

Next-Generation Sequencing is a rapidly advancing technology that has research and clinical applications. For many cancers, it is important to know the precise mutation(s) present, as specific mutations could indicate or contra-indicate certain treatments as well as be indicative of prognosis. Using the Ion Torrent Personal Genome Machine and the AmpliSeq Cancer Hotspot panel v2, we sequenced two pancreatic cancer cell lines, BxPC-3 and HPAF-II, alone or in mixtures, to determine the error rate, sensitivity, and reproducibility of this system. The system resulted in coverage averaging 2000× across the various amplicons and was able to reliably and reproducibly identify mutations present at a rate of 5%. Identification of mutations present at a lower rate was possible by altering the parameters by which calls were made, but with an increase in erroneous, low-level calls. The panel was able to identify known mutations in these cell lines that are present in the COSMIC database. In addition, other, novel mutations were also identified that may prove clinically useful. The system was assessed for systematic errors such as homopolymer effects, end of amplicon effects and patterns in NO CALL sequence. Overall, the system is adequate at identifying the known, targeted mutations in the panel.


Asunto(s)
Biomarcadores de Tumor/genética , Análisis Mutacional de ADN , Perfilación de la Expresión Génica , Genoma Humano , Genómica/métodos , Secuenciación de Nucleótidos de Alto Rendimiento , Mutación , Neoplasias Pancreáticas/genética , Línea Celular Tumoral , Biología Computacional , Bases de Datos Genéticas , Predisposición Genética a la Enfermedad , Humanos , Análisis de Secuencia por Matrices de Oligonucleótidos , Neoplasias Pancreáticas/patología , Fenotipo , Reproducibilidad de los Resultados , Programas Informáticos
4.
Mutagenesis ; 30(4): 577-91, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25964273

RESUMEN

The focus of this research was to develop a better understanding of the pertinent physico-chemical properties of silver nanoparticles (AgNPs) that affect genotoxicity, specifically how cellular uptake influences a genotoxic cell response. The genotoxicity of AgNPs was assessed for three potential mechanisms: mutagenicity, clastogenicity and DNA strand-break-based DNA damage. Mutagenicity (reverse mutation assay) was assessed in five bacterial strains of Salmonella typhimurium and Echerichia coli, including TA102 that is sensitive to oxidative DNA damage. AgNPs of all sizes tested (10, 20, 50 and 100nm), along with silver nitrate (AgNO3), were negative for mutagenicity in bacteria. No AgNPs could be identified within the bacteria cells using transmission electron microscopy (TEM), indicating these bacteria lack the ability to actively uptake AgNPs 10nm or larger. Clastogenicity (flow cytometry-based micronucleus assay) and intermediate DNA damage (DNA strand breaks as measured in the Comet assay) were assessed in two mammalian white blood cell lines: Jurkat Clone E6-1 and THP-1. It was observed that micronucleus and Comet assay end points were inversely correlated with AgNP size, with smaller NPs inducing a more genotoxic response. TEM results indicated that AgNPs were confined within intracellular vesicles of mammalian cells and did not penetrate the nucleus. The genotoxicity test results and the effect of AgNO3 controls suggest that silver ions may be the primary, and perhaps only, cause of genotoxicity. Furthermore, since AgNO3 was not mutagenic in the gram-negative bacterial Ames strains tested, the lack of bacterial uptake of the AgNPs may not be the major reason for the lack of genotoxicity observed.


Asunto(s)
Antibacterianos/farmacología , Daño del ADN/efectos de los fármacos , Escherichia coli/genética , Nanopartículas del Metal/administración & dosificación , Mutágenos/farmacología , Salmonella typhimurium/genética , Plata/química , Supervivencia Celular/efectos de los fármacos , Supervivencia Celular/genética , Células Cultivadas , Ensayo Cometa , Daño del ADN/genética , Reparación del ADN/efectos de los fármacos , Escherichia coli/efectos de los fármacos , Escherichia coli/metabolismo , Infecciones por Escherichia coli/tratamiento farmacológico , Infecciones por Escherichia coli/genética , Infecciones por Escherichia coli/microbiología , Humanos , Células Jurkat , Nanopartículas del Metal/química , Pruebas de Micronúcleos/métodos , Microscopía Electrónica de Transmisión , Monocitos/citología , Monocitos/efectos de los fármacos , Monocitos/metabolismo , Pruebas de Mutagenicidad/métodos , Salmonella typhimurium/efectos de los fármacos , Salmonella typhimurium/metabolismo
5.
Front Toxicol ; 6: 1370045, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38646442

RESUMEN

The ICH S1B carcinogenicity global testing guideline has been recently revised with a novel addendum that describes a comprehensive integrated Weight of Evidence (WoE) approach to determine the need for a 2-year rat carcinogenicity study. In the present work, experts from different organizations have joined efforts to standardize as much as possible a procedural framework for the integration of evidence associated with the different ICH S1B(R1) WoE criteria. The framework uses a pragmatic consensus procedure for carcinogenicity hazard assessment to facilitate transparent, consistent, and documented decision-making and it discusses best-practices both for the organization of studies and presentation of data in a format suitable for regulatory review. First, it is acknowledged that the six WoE factors described in the addendum form an integrated network of evidence within a holistic assessment framework that is used synergistically to analyze and explain safety signals. Second, the proposed standardized procedure builds upon different considerations related to the primary sources of evidence, mechanistic analysis, alternative methodologies and novel investigative approaches, metabolites, and reliability of the data and other acquired information. Each of the six WoE factors is described highlighting how they can contribute evidence for the overall WoE assessment. A suggested reporting format to summarize the cross-integration of evidence from the different WoE factors is also presented. This work also notes that even if a 2-year rat study is ultimately required, creating a WoE assessment is valuable in understanding the specific factors and levels of human carcinogenic risk better than have been identified previously with the 2-year rat bioassay alone.

6.
Mutat Res ; 752(1): 6-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-22935230

RESUMEN

Next-generation sequencing technologies can now be used to directly measure heritable de novo DNA sequence mutations in humans. However, these techniques have not been used to examine environmental factors that induce such mutations and their associated diseases. To address this issue, a working group on environmentally induced germline mutation analysis (ENIGMA) met in October 2011 to propose the necessary foundational studies, which include sequencing of parent-offspring trios from highly exposed human populations, and controlled dose-response experiments in animals. These studies will establish background levels of variability in germline mutation rates and identify environmental agents that influence these rates and heritable disease. Guidance for the types of exposures to examine come from rodent studies that have identified agents such as cancer chemotherapeutic drugs, ionizing radiation, cigarette smoke, and air pollution as germ-cell mutagens. Research is urgently needed to establish the health consequences of parental exposures on subsequent generations.


Asunto(s)
Interacción Gen-Ambiente , Enfermedades Genéticas Congénitas/genética , Genómica , Animales , Contaminantes Ambientales/toxicidad , Mutación de Línea Germinal , Humanos , Efectos de la Radiación , Productos de Tabaco/efectos adversos
7.
Front Toxicol ; 5: 1171960, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180488

RESUMEN

The in vitro micronucleus (MNvit) assay is used to evaluate the aneugenic and clastogenic potential of a test material based upon its ability to induce micronuclei in the cells. This protocol is provided for testing of nanomaterials (NM) with standard cell lines in the absence of metabolic activation. The use of cytochalasin B (CytoB) and the analysis of binucleated cells in the cytokinesis-block version of the micronucleus assay ensures that cells analyzed have undergone cell division, which is required for expression of DNA damage and micronucleus formation. Issues specific to NM that were problematic with standard test methods are addressed, including test system choice, dose selection, test material exposures, CytoB timing, cytotoxicity determination, and DNA damage expression time. A step-by-step protocol for in vitro micronucleus assessment of NM is provided.

8.
Photochem Photobiol ; 2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-37496175

RESUMEN

Various fluorescence imaging agents are currently under clinical studies. Despite significant benefits, phototoxicity is a barrier to the clinical translation of fluorophores. Current regulatory guidelines on medication-based phototoxicity focus on skin effects during sun exposure. However, with systemic and local administration of fluorophores and targeted illumination, there is now possibility of photochemical damage to deeper tissues during intraoperative imaging procedures. Hence, independent knowledge regarding phototoxicity is required to facilitate the development of fluorescence imaging products. Previously, we studied a cell-free assay for initial screening of reactive molecular species generation from fluorophores. The current work addresses a safety test method based on cell viability as an adjunct and a comparator with the cell-free assay. Our goal is to modify and implement an approach based on the in vitro 3T3 neutral red uptake assay of the Organization for Economic Co-Operation and Development Test Guideline 432 (OECD TG432) to evaluate the photocytotoxicity of clinically relevant fluorophores. These included indocyanine green (ICG), proflavine, methylene blue (MB), and IRDye800, as well as control photosensitizers, benzoporphyrin derivative (BPD) and rose bengal (RB). We performed measurements at agent concentrations and illumination parameters used for clinic imaging. Our results aligned with prior studies, indicating photocytotoxicity in RB and BPD and an absence of reactivity for ICG and IRDye800. DNA interactive agents, proflavine and MB, exhibited drug/light dose-response curves like photosensitizers. This study provides evidence and insights into practices useful for testing the photochemical safety of fluorescence imaging products.

9.
Front Toxicol ; 4: 864753, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757197

RESUMEN

The methods outlined here are part of a series of papers designed specifically for genotoxicity assessment of nanomaterials (NM). Common Considerations such as NM characterization, sample preparation and dose selection, relevant to all genotoxicity assays, are found in an accompanying paper. The present paper describes methods for evaluation of mutagenicity in the mammalian (mouse) thymidine kinase (Tk) gene occurring in L5178Y mouse lymphoma (ML) cells and in the designated TK gene in human lymphoblastoid TK6 cells. Mutations change the functional genotype from TK+/- to TK-/-, detectable as cells surviving on media selective for the lack of thymidine kinase (TK) function. Unlike cells with TK enzyme function, the TK-/- cells are unable to integrate the toxic selection agent, allowing these cells to survive as rare mutant colonies. The ML assay has been shown to detect a broad spectrum of genetic damage, including both small scale (point) mutations and chromosomal alterations. This assay is a widely used mammalian cell gene mutation assay for regulatory purposes and is included in the core battery of genotoxicity tests for regulatory decision-making. The TK6 assay is an assay using a human cell line derived similarly via mutagenic manipulations and optimal selection. Details are provided on the materials required, cell culture methods, selection of test chemical concentrations, cytotoxicity, treatment time, mutation expression, cloning, and data calculation and interpretation. The methods describe the microwell plate version of the assays without metabolic activation.

10.
Front Toxicol ; 4: 903896, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35707495

RESUMEN

The in vivo Comet assay measures the generation of DNA strand breaks under conditions in which the DNA will unwind and migrate to the anode in an electrophoresis assay, producing comet-like figures. Measurements are on single cells, which allows the sampling of a diversity of cells and tissues for DNA damaging effects. The Comet assay is the most common in vivo method for genotoxicity assessment of nanomaterials (NM). The Method outlined here includes a recommended step-by-step approach, consistent with OECD 489, taking into consideration the issues impacting assessment of NM, including choice of cells or systems, handling of NM test articles, dose determination, assay methods and data assessment. This method is designed to be used along with the accompanying "Common Considerations" paper, which discusses issues common to any genotoxicity assay using NM as a test article.

11.
Front Toxicol ; 4: 859122, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35686044

RESUMEN

Genotoxicity testing is performed to determine potential hazard of a chemical or agent for direct or indirect DNA interaction. Testing may be a surrogate for assessment of heritable genetic risk or carcinogenic risk. Testing of nanomaterials (NM) for hazard identification is generally understood to require a departure from normal testing procedures found in international standards and guidelines. A critique of the genotoxicity literature in Elespuru et al., 2018, reinforced evidence of problems with genotoxicity assessment of nanomaterials (NM) noted by many previously. A follow-up to the critique of problems (what is wrong) is a series of methods papers in this journal designed to provide practical information on what is appropriate (right) in the performance of genotoxicity assays altered for NM assessment. In this "Common Considerations" paper, general considerations are addressed, including NM characterization, sample preparation, dosing choice, exposure assessment (uptake) and data analysis that are applicable to any NM genotoxicity assessment. Recommended methods for specific assays are presented in a series of additional papers in this special issue of the journal devoted to toxicology methods for assessment of nanomaterials: the In vitro Micronucleus Assay, TK Mutagenicity assays, and the In vivo Comet Assay. In this context, NM are considered generally as insoluble particles or test articles in the nanometer size range that present difficulties in assessment using techniques described in standards such as OECD guidelines.

12.
Photochem Photobiol ; 98(4): 736-747, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35442536

RESUMEN

The benefits of contrast-enhancing imaging probes have become apparent over the past decade. However, there is a gap in the literature when it comes to the assessment of the phototoxic potential of imaging probes and systems emitting visible and/or near-infrared radiation. The primary mechanism of fluorescent agent phototoxicity is thought to involve the production of reactive molecular species (RMS), yet little has been published on the best practices for safety evaluation of RMS production levels for clinical products. We have proposed methods involving a cell-free assay to quantify singlet oxygen [(SO) a known RMS] generation of imaging probes, and performed testing of Indocyanine Green (ICG), Proflavine, Methylene Blue, IR700 and IR800 at clinically relevant concentrations and radiant exposures. Results indicated that SO production from IR800 and ICG were more than two orders of magnitude below that of the known SO generator Rose Bengal. Methylene Blue and IR700 produced much higher SO levels than ICG and IR800. These results were in good agreement with data from the literature. While agents that exhibit spectral overlap with the assay may be more prone to errors, our tests for one of these agents (Proflavine) appeared robust. Overall, our results indicate that this methodology shows promise for assessing the phototoxic potential of fluorophores due to SO production.


Asunto(s)
Azul de Metileno , Oxígeno Singlete , Verde de Indocianina , Imagen Óptica , Proflavina
13.
Artículo en Inglés | MEDLINE | ID: mdl-34454692

RESUMEN

Kirkland et al. [Mutation Research/Genetic Toxicology and Environmental Mutagenesis 847 (2019) 403035, https://doi.org/10.1016/j.mrgentox.2019.03.008; Mutation Research/Genetic Toxicology and Environmental Mutagenesis 839 (2019): 21-35, https://doi.org/10.1016/j.mrgentox.2019.01.007] made recommendations on the use of the in vivo comet and transgenic rodent (TGR) gene mutation assays to screen for in vivo mutagenicity. Although it is not directly stated in either of these publications, we are concerned that the reports could potentially be used to support assertions that it is equally acceptable to follow up a positive bacterial reverse mutation (Ames) finding for an investigational drug with either the in vivo TGR mutation assay or an in vivo comet assay. For regulatory genotoxicity assessment, the in vivo follow-up for an in vitro bacterial mutation-positive drug, drug-related metabolite, or impurity should be based upon evaluating a similar endpoint (i.e., mutagenicity) as the intent is to determine if the findings of in vitro gene mutation correlate with findings of in vivo gene mutation (i.e., biologically relevant to the in vitro results). Thus, the most scientifically appropriate in vivo assays would be the TGR mutation assay or, in some circumstances, the in vivo Pig-a assay. An in vivo rodent comet assay or combination of the in vivo micronucleus and in vivo rodent comet assays would generally not be an appropriate follow-up test.


Asunto(s)
Bioensayo/métodos , Drogas en Investigación/química , Drogas en Investigación/metabolismo , Mutación/efectos de los fármacos , Animales , Animales Modificados Genéticamente/genética , Carcinógenos/toxicidad , Ensayo Cometa/métodos , Estudios de Seguimiento , Pruebas de Micronúcleos/métodos , Pruebas de Mutagenicidad/métodos , Mutágenos/toxicidad , Roedores
14.
Comput Toxicol ; 202021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35368437

RESUMEN

Historically, identifying carcinogens has relied primarily on tumor studies in rodents, which require enormous resources in both money and time. In silico models have been developed for predicting rodent carcinogens but have not yet found general regulatory acceptance, in part due to the lack of a generally accepted protocol for performing such an assessment as well as limitations in predictive performance and scope. There remains a need for additional, improved in silico carcinogenicity models, especially ones that are more human-relevant, for use in research and regulatory decision-making. As part of an international effort to develop in silico toxicological protocols, a consortium of toxicologists, computational scientists, and regulatory scientists across several industries and governmental agencies evaluated the extent to which in silico models exist for each of the recently defined 10 key characteristics (KCs) of carcinogens. This position paper summarizes the current status of in silico tools for the assessment of each KC and identifies the data gaps that need to be addressed before a comprehensive in silico carcinogenicity protocol can be developed for regulatory use.

15.
Polymers (Basel) ; 12(7)2020 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-32635323

RESUMEN

Lithium phenyl (2,4,6-trimethylbenzoyl) phosphinate (LAP) is a free radical photo-initiator used to initiate free radical chain polymerization upon light exposure, and is combined with gelatin methacryloyl (GelMA) to produce a photopolymer used in bioprinting. The free radicals produced under bioprinting conditions are potentially cytotoxic and mutagenic. Since these photo-generated free radicals are highly-reactive but short-lived, toxicity assessments should be conducted with light exposure. In this study, photorheology determined that 10 min exposure to 9.6 mW/cm2 405 nm light from an LED light source fully crosslinked 10 wt % GelMA with >3.4 mmol/L LAP, conditions that were used for subsequent cytotoxicity and mutagenicity assessments. These conditions were cytotoxic to M-1 mouse kidney collecting duct cells, a cell type susceptible to lithium toxicity. Exposure to ≤17 mmol/L (0.5 wt %) LAP without light was not cytotoxic; however, concurrent exposure to ≥3.4 mmol/L LAP and light was cytotoxic. No condition of LAP and/or light exposure evaluated was mutagenic in bacterial reverse mutation assays using S. typhimurium strains TA98, TA100 and E. coli WP2 uvrA. These data indicate that the combination of LAP and free radicals generated from photo-excited LAP is cytotoxic, but mutagenicity was not observed in bacteria under typical bioprinting conditions.

16.
Environ Mol Mutagen ; 61(1): 152-175, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31469467

RESUMEN

Cancer driver mutations (CDMs) are necessary and causal for carcinogenesis and have advantages as reporters of carcinogenic risk. However, little progress has been made toward developing measurements of CDMs as biomarkers for use in cancer risk assessment. Impediments for using a CDM-based metric to inform cancer risk include the complexity and stochastic nature of carcinogenesis, technical difficulty in quantifying low-frequency CDMs, and lack of established relationships between cancer driver mutant fractions and tumor incidence. Through literature review and database analyses, this review identifies the most promising targets to investigate as biomarkers of cancer risk. Mutational hotspots were discerned within the 20 most mutated genes across the 10 deadliest cancers. Forty genes were identified that encompass 108 mutational hotspot codons overrepresented in the COSMIC database; 424 different mutations within these hotspot codons account for approximately 63,000 tumors and their prevalence across tumor types is described. The review summarizes literature on the prevalence of CDMs in normal tissues and suggests such mutations are direct and indirect substrates for chemical carcinogenesis, which occurs in a spatially stochastic manner. Evidence that hotspot CDMs (hCDMs) frequently occur as tumor subpopulations is presented, indicating COSMIC data may underestimate mutation prevalence. Analyses of online databases show that genes containing hCDMs are enriched in functions related to intercellular communication. In its totality, the review provides a roadmap for the development of tissue-specific, CDM-based biomarkers of carcinogenic potential, comprised of batteries of hCDMs and can be measured by error-correct next-generation sequencing. Environ. Mol. Mutagen. 61:152-175, 2020. Published 2019. This article is a U.S. Government work and is in the public domain in the USA. Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society.


Asunto(s)
Carcinogénesis/genética , Mutación , Neoplasias/genética , Animales , Biomarcadores de Tumor/genética , Carcinogénesis/inducido químicamente , Carcinógenos/toxicidad , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Mutación/efectos de los fármacos , Neoplasias/inducido químicamente , Medición de Riesgo/métodos
17.
Artículo en Inglés | MEDLINE | ID: mdl-32087853

RESUMEN

The International Workshop on Genotoxicity Testing (IWGT) meets every four years to obtain consensus on unresolved issues associated with genotoxicity testing. At the 2017 IWGT meeting in Tokyo, four sub-groups addressed issues associated with the Organization for Economic Cooperation and Development (OECD) Test Guideline TG471, which describes the use of bacterial reverse-mutation tests. The strains sub-group analyzed test data from >10,000 chemicals, tested additional chemicals, and concluded that some strains listed in TG471 are unnecessary because they detected fewer mutagens than other strains that the guideline describes as equivalent. Thus, they concluded that a smaller panel of strains would suffice to detect most mutagens. The laboratory proficiency sub-group recommended (a) establishing strain cell banks, (b) developing bacterial growth protocols that optimize assay sensitivity, and (c) testing "proficiency compounds" to gain assay experience and establish historical positive and control databases. The sub-group on criteria for assay evaluation recommended that laboratories (a) track positive and negative control data; (b) develop acceptability criteria for positive and negative controls; (c) optimize dose-spacing and the number of analyzable doses when there is evidence of toxicity; (d) use a combination of three criteria to evaluate results: a dose-related increase in revertants, a clear increase in revertants in at least one dose relative to the concurrent negative control, and at least one dose that produced an increase in revertants above control limits established by the laboratory from historical negative controls; and (e) establish experimental designs to resolve unclear results. The in silico sub-group summarized in silico utility as a tool in genotoxicity assessment but made no specific recommendations for TG471. Thus, the workgroup identified issues that could be addressed if TG471 is revised. The companion papers (a) provide evidence-based approaches, (b) recommend priorities, and (c) give examples of clearly defined terms to support revision of TG471.


Asunto(s)
Escherichia coli/efectos de los fármacos , Mutagénesis , Pruebas de Mutagenicidad/normas , Mutágenos/toxicidad , Salmonella typhimurium/efectos de los fármacos , Animales , Bancos de Muestras Biológicas/organización & administración , Bases de Datos de Compuestos Químicos/provisión & distribución , Escherichia coli/genética , Guías como Asunto , Humanos , Cooperación Internacional , Mutágenos/clasificación , Salmonella typhimurium/genética , Tokio
18.
Artículo en Inglés | MEDLINE | ID: mdl-31708075

RESUMEN

The International Workshop on Genotoxicity Testing (IWGT) meets every four years to seek consensus on difficult or conflicting approaches to genotoxicity testing based upon experience, available data, and analysis techniques. At the 2017 IWGT meeting in Tokyo, one working group addressed the sensitivity and selectivity of the bacterial strains specified in the Organization for Economic Cooperation and Development (OECD) Test Guideline TG471 to recommend possible modification of the test guideline. Three questions were posed: (1) Although TA100 is derived from TA1535, does TA1535 detect any mutagens that are not detected by TA100? (2) Among the options of Salmonella TA1537, TA97 or TA97a, are these strains truly equivalent? (3) Because there is a choice to use one of either E. coli WP2 uvrA, E. coli WP2 uvrA pKM101, or Salmonella TA102, are these strains truly equivalent? To answer these questions, we analyzed published bacterial mutation data in multiple strains from large (>10,000 compound) databases from Leadscope and Lhasa Limited and anonymized data for 53 compounds tested in TA1535 and TA100 provided by a pharmaceutical company. Our analysis involved (1) defining criteria for determining selective responses when using different strains; (2) identifying compounds producing selective responses based upon author calls; (3) confirming selective responses by visually examining dose-response data and considering experimental conditions; (4) using statistical methods to quantify the responses; (5) performing limited additional direct-comparison testing; and (6) determining the chemical classes producing selective responses. We found that few mutagens would fail to be detected if the test battery did not include Salmonella strains TA1535 (8/1167), TA1537 (2/247), TA102 (4/46), and E. coli WP2 uvrA (2/21). Of the mutagens detected by the full TG471 strain battery, 93% were detected using only strains TA98 and TA100; consideration of results from in vitro genotoxicity assays that detect clastogenicity increased this to 99%.


Asunto(s)
Guías como Asunto , Pruebas de Mutagenicidad/normas , Escherichia coli/genética , Salmonella/genética
19.
Artículo en Inglés | MEDLINE | ID: mdl-31708077

RESUMEN

The bacterial reverse mutation test is a mainstay for evaluation of mutagenicity predicting the carcinogenic potential of a test substance and is recommended by regulatory agencies across the globe. The popularity of the test is due, in part, to the relatively low cost, rapid results and small amount of test material required compared to most other toxicological tests as well as the near universal acceptance of the toxicological significance of a clear positive or negative result. Most laboratories follow the Organization for Economic Cooperation and Development Test Guideline 471 (TG471) or national guidelines based on TG471. Regulatory agencies in most countries are obligated to consider results from tests which meet the recommendations laid out in TG471. Nonetheless, laboratories unfamiliar with the test sometimes have trouble generating reliable, reproducible results. TG471 is a test guideline, not a detailed test protocol. A group of experts from regulatory agencies and laboratories which use the assay has assembled here a set of recommendations which if followed, will allow an inexperienced laboratory to acquire proficiency in assay conduct. These include recommendations for how to create a cell bank for the 5 Salmonella typhimurium/Escherichia coli strains and develop a laboratory protocol to reliably culture each strain to ensure each culture has the characteristics which allow adequate sensitivity for detection of mutagens using the test as described in TG471. By testing compounds on the provided lists of positive and negative test substances, the laboratory will have surmounted many of the problems commonly encountered during routine testing of unknown chemicals and will have gained the experience necessary to prepare the detailed protocol needed for performing the test under Good Laboratory Procedures and the laboratory will have generated the historical positive and negative control databases which are needed for test reports which adhere to TG471.


Asunto(s)
Eficiencia Organizacional , Escherichia coli/genética , Laboratorios/organización & administración , Pruebas de Mutagenicidad , Salmonella typhimurium/genética
20.
Toxicol Sci ; 164(2): 391-416, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29701824

RESUMEN

Nanomaterials (NMs) present unique challenges in safety evaluation. An international working group, the Genetic Toxicology Technical Committee of the International Life Sciences Institute's Health and Environmental Sciences Institute, has addressed issues related to the genotoxicity assessment of NMs. A critical review of published data has been followed by recommendations on methods alterations and best practices for the standard genotoxicity assays: bacterial reverse mutation (Ames); in vitro mammalian assays for mutations, chromosomal aberrations, micronucleus induction, or DNA strand breaks (comet); and in vivo assays for genetic damage (micronucleus, comet and transgenic mutation assays). The analysis found a great diversity of tests and systems used for in vitro assays; many did not meet criteria for a valid test, and/or did not use validated cells and methods in the Organization for Economic Co-operation and Development Test Guidelines, and so these results could not be interpreted. In vivo assays were less common but better performed. It was not possible to develop conclusions on test system agreement, NM activity, or mechanism of action. However, the limited responses observed for most NMs were consistent with indirect genotoxic effects, rather than direct interaction of NMs with DNA. We propose a revised genotoxicity test battery for NMs that includes in vitro mammalian cell mutagenicity and clastogenicity assessments; in vivo assessments would be added only if warranted by information on specific organ exposure or sequestration of NMs. The bacterial assays are generally uninformative for NMs due to limited particle uptake and possible lack of mechanistic relevance, and are thus omitted in our recommended test battery for NM assessment. Recommendations include NM characterization in the test medium, verification of uptake into target cells, and limited assay-specific methods alterations to avoid interference with uptake or endpoint analysis. These recommendations are summarized in a Roadmap guideline for testing.


Asunto(s)
Pruebas de Mutagenicidad/métodos , Nanoestructuras/toxicidad , Animales , Aberraciones Cromosómicas , Ensayo Cometa , Humanos , Técnicas In Vitro/métodos , Pruebas de Mutagenicidad/normas , Mutación
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda